SK 9000 characteristics ................................................................ 20
SK 9000 | 1
Important safety instructions
Important safety instructions
• Read this instruction manual.
• Keep this instruction manual. Always include this instruction
manual when
• Heed all warnings and follow all instructions.
• Do not use the product near water.
• Only clean the product with a dry cloth.
• Do not place the product near any heat sources such as radiators, stoves, or other devices (including amplifiers) that produce
heat.
• Only use attachments, accessories or spare parts specified by
nnhe
Se
• Refer all servicing to qualified service personnel. Servicing is
required i
been spilled, objects have fallen inside, the product has been
exposed to rain or moisture, does not operate properly or has
been dropped.
WARNING: To reduce the risk of fire or electric shock,
•
do not expose the product to rain or moisture.
• Do not expose the product to dripping or splashing.
Intended use
Intended use of the Digital 9000 system components includes:
• having read and understood this instruction manual,
the chapter “Important safety instructions”,
• using the product within the operating conditions and limitations de
“Improper use” means using the product other than as described in
these instructions, or under operating conditions which differ from
those described herein.
This instruction manual is also available at www.sennheiser.com.
passing the product on to third parties.
iser.
f the product has been damaged in any way, liquid has
especially
scribed in this instruction manual.
Safety instructions for lithium-ion rechargeable batteries
If abused or misused, the rechargeable batteries may leak. In
extreme cases, they may even present a risk of
•explosion,
• fire development,
Sennheiser does not accept any liability for damage arising from
use or
misuse.
ab
2 | SK 9000
• heat generation,
• smoke or gas development.
Important safety instructions
ENFRITNLPTRUZHESDE
Keep away from
children.
Observe correct polarity.
Do not expose to
moisture.
Only charge rechargeable batteries at
ambient temperatures
between 10 °C/50 °F
and 40 °C/104
Do not mutilate or
dismantle.
Immediately remove
rechargeable batteries
from an obviously
defective product.
Do not continue to use
defective rechargeable
batteries.
Only use rechargeable
batteries specified by
Sennheiser.
Remove the rechargeable batteries if the
prod
uct will not be
used for extended
periods of time.
Store the product in
a cool and dry place
at room temperature
(approx. 20 °C/68 °F).
°F.
Only charge
rechargeable
batteries with a
charger recommended by
Sennheiser.
Pack/store
charged
rechargeable batteries so that the
rminals cannot
te
con
tact each
other – danger
of shorting out/
fire hazard.
Switch rechargeable batterypowered products off after use.
When not using
rechargeable
batteries for
extended periods
of time, charge
them regularly
(about every
three months).
Do not heat
above 70 °C/
°F, e.g. do
158
not expose to
sunlight or throw
llection
.
points
into a fire
Dispose of
rechargeable batteries at special
co
or return them to
your specialist
dealer.
SK 9000 | 3
The SK 9000 bodypack transmitter
The SK 9000 bodypack transmitter
The SK 9000 transmitter offers great ease of use and can easily be
adapted to any transmission situation:
•Rugged housing
• Input gain adjustable in 3 dB steps
•Switchable 1 kHz test tone, useful for level matching the system
r the walk test
and fo
• H
igh accuracy of charge status display (BA 61) or remaining
operating time display (B
• Switchable low cut filter for filtering out low frequency
• F
• Power supply optionally via BA 61 lithium-ion accupack or B 61
• Automatic detection of the input signal type (mic, line, instru-
• Emulation of different guitar cable lengths
• Different clip-on microphones for different areas of application
• Command function via KA 900
onents
comp
requencies tuneable in 25 kHz steps
battery pack (3 AA size alkaline batteries or 3 AA size lithium
batteries)
ment) when Sennheiser accessories are used
(see page 6)
61)
0 COM command adapter
Delivery includes
1 SK 9000 bodypack transmitter
1 supplement “Framework requirements and restrictions on
y usage”
frequenc
1 instruction manual
You additionally require microphones or the CI 1-4 line/
as well
instrument cable
battery pack.
A list of accessories can be found on the Digital 9000
product page at www.sennheiser.com.
For information on suppliers, contact your local Sennheiser
partner: www.sennheiser.com > “Se
4 | SK 9000
as a BA 61 accupack and/or a B 61
rvice & Support”.
Product overview
ENFRITNLPTRUZHESDE
Product overview
1
2
3
4
C
9
0
B
A
E
1 3-pin special audio socket
for
- Sennheiser microphones
- Sennheiser CI 1-4
strume
in
nt cable
- KA 9000 COM command
adapter
FF button
2 ON/O
with ESC function (cancel)
3 ON LED
- lights up constantly:
transmitter is operational
- flashes regularly:
remaining operating time
than 30 minutes
is less
lashes with high levels:
- f
audio signal is excessively
h
hig
4 Anten
na socket
5
6
7
8
9
0
F
D
5 Infra-red interface
6 DOWN button
7 SET button
8 UP button
9 Catches
for accupack/battery pack
0 Snap-in elements
for accupack/battery pack
A Guide rails
for accupack/battery pack
B Contacts
for supply voltage and
data contacts
C Display panel
D Belt clip
E Battery pack
for 3 AA size cells
F Accupack
SK 9000 | 5
Preparing the SK 9000 for use
3:59
480.000
135462
Overview of the standard display after switch-on
After switch-on, the bodypack transmitter displays the following
standard display:
Condenser microphones for SK 9000 bodypack transmitter
MicrophonePick-up pattern
MKE 1omni-directional
MKE 2cardioid
ME 102omni-directional
ME 104cardioid
ME 105super-cardioid
HSP 2omni-directional
HSP 4cardioid
Sennheiser CI 1-4 line/instrument cable
¼’’ (6.3 mm) jack plug (silent plug) to 3-pin special audio connector
Preparing the SK 9000 for use
For detailed information on the following points, refer to
the instruction manual for the Digital 9000 system.
Selecting the accupack/battery pack
You can power the SK 9000 bodypack transmitter using:
•the BA 61 accupack
he B 61 battery pack for three 1.5 V AA size
•t
6 | SK 9000
batteries
Preparing the SK 9000 for use
ENFRITNLPTRUZHESDE
Charge the BA 61 accupack before using it for the first time
(see the instruction manual for the Digital 9000 system).
CAUTION!
Damage to the bodypack transmitter
battery pack
If you touch the following contacts, they can become dirty or
damaged:
Contacts for supply voltage
•
and data contacts B of the
bodypack transmitter
• Charging and data contacts
the BA 61 accupack
of
•
Data contacts of the B 61
battery pack
and/or
the accupack/
B
왘 Do not touch the contacts of
the accupack/battery pack nor the contacts of the bodypack
transmitter.
Inserting batteries into the B 61 battery pack
왘 Insert the batteries into the battery pack (see diagram). Observe
correct polarity when inserting the batteries.
Only insert high-quality AA size batteries (e.g. lithium or
alkaline batteries) into the B 61 battery pack. If you insert
rechargeable batteries, the charge status display 1 will
show a wrong value.
SK 9000 | 7