518–554 MHz
Additional information for Sennheiser evolution wireless G3 systems
Transmitters and receivers are available in a 36 MHz UHF frequency range with a total of 1,440 transmission/receiving frequencies.
Transmitters and receivers have 20 frequency banks respec­tively. Each of the channels in the frequency banks has been factory-preset to a frequency. The frequency presets within one frequency bank are intermodulation-free. These frequencies cannot be changed.
The frequency bank “U” allows the user to store individual frequencies which are freely selectable in 25-kHz steps. It might be that these frequencies are not intermodulation-free.
The following table lists the frequency presets in the frequency banks “1” to “20”.
The following factory-preset default settings can be recalled any time via the Reset menu item:
Auto Lock inactive Sensitivity SK –30 dB
SKM –18 dB Mute Mode AF On/Off (SK) Squelch low AF Out EM +18 dB Equalizer flat Guitar Tuner inactive Name name of the series Pilot Tone will not be reset User bank “U”will not be reset
Informations complémentaires concernant les systèmes evolution wireless ew G3
Les émetteurs et les récepteurs sont disponibles dans une plage de fréquences UHF de 36 MHz de largeur, ce qui autorise un choix parmi 1440 fréquences d’émission et de réception.
Les émetteurs et les récepteurs possèdent 20 banques de fré­quences, dans lesquelles chaque canal est préréglé en usine sur une fréquence. Les fréquences préréglées au sein d’une banque de fréquence sont compatibles entre elles, c.à.d. exemptes d’intermodulation. Elles ne peuvent pas être modifiées.
La banque de fréquences « U » ces au choix, peut que ces fréquences ne soient pas exemptes d’intermodu­lation.
Le tableau suivant dresse la liste des fréquences préréglées dans les banques de fréquences « 1 » à « 20 ».
Les paramètres par défaut suivants, préréglés en usine, peuvent être restaurés à tout moment via l’option Reset :
Auto Lock inactif Sensitivity SK –30 dB
Mute Mode AF On/Off (SK) Squelch low AF Out EM +18 dB Equalizer flat Guitar Tuner inactif Name nom de la série Pilot Tone n’est pas réinitialisé Banque « U » n’est pas réinitialisée
qui peuvent être réglées par pas de 25 kHz. Il se
SKM –18 dB
permet de mémoriser des fréquen-
Sennheiser electronic GmbH & Co. KG Printed in Germany 30900 Wedemark, Germany Publ. 01/09 www.sennheiser.com 532015/A01
Page 2
US_BerA_518-554MHz_532015_0109_Sp4.fm Seite 2 Freitag, 6. Februar 2009 5:22 17
Frequency Range / Bande de fréquence / Rango de frecuencia / Gama de frequências A2
518–554 MHz
US TV-channel
Ch. 22 (518–524 MHz) Ch. 25 (536–542 MHz) Ch. 23 (524–530 MHz) Ch. 26 (542–548 MHz) Ch. 24 (530–536 MHz) Ch. 27 (548–554 MHz)
Channel Bank 1 Bank 2 Bank 3 Bank 4 Bank 5 Bank 6 Bank 7 Bank 8 Bank 9 Bank 10
1 2 3 4 5 6
Note US TV-Ch. 22 US TV-Ch. 23 US TV-Ch. 24 US TV-Ch. 25 US TV-Ch. 26 US TV-Ch.. 27 US TV-Ch.
Remarque Etats-Unis
Nota EE.UU. Canal
Observação E.U.A. Canal
518,200 524,700 530,850 536,950 542,200 548,650 518,900 524,600 531,100 536,750 520,700 525,200 531,350 537,400 542,600 549,300 521,650 526,800 531,950 540,800 521,800 526,850 532,600 538,450 544,400 550,250 523,200 527,500 534,400 541,250 522,200 527,500 533,400 539,050 545,150 551,700 526,550 528,600 538,650 543,300 522,750 528,300 534,850 540,400 546,050 552,500 527,950 532,950 539,650 545,550 523,500 529,400 535,800 541,300 547,100 553,700 528,900 535,600 540,050 546,300
canal TV 22
TV 22
TV 22
Etats-Unis
canal TV 23
EE.UU. Canal
TV 23
E.U.A. Canal
TV 23
Etats-Unis
canal TV 24
EE.UU. Canal
TV 24
E.U.A. Canal
TV 24
Etats-Unis
canal TV 25
EE.UU. Canal
TV 25
E.U.A. Canal
TV 25
Etats-Unis
canal TV 26
EE.UU. Canal
TV 26
E.U.A. Canal
TV 26
Etats-Unis
canal TV 27
EE.UU. Canal
TV 27
E.U.A. Canal
TV 27
22 & 23
Etats-Unis canaux TV
22 & 23
EE.UU. Canales
TV 22 & 23
E.U.A. Canales
TV 22 & 23
US TV-Ch.
23 & 24
Etats-Unis canaux TV
23 & 24
EE.UU. Canales
TV 23 & 24
E.U.A. Canales
TV 23 & 24
US TV-Ch.
24 & 25
Etats-Unis canaux TV
24 & 25
EE.UU. Canales
TV 24 & 25
E.U.A. Canales
TV 24 & 25
US TV-Ch.
25 & 26
Etats-Unis canaux TV
25 & 26
EE.UU. Canales
TV 25 & 26
E.U.A. Canales
TV 25 & 26
Page 3
US_BerA_518-554MHz_532015_0109_Sp4.fm Seite 3 Freitag, 6. Februar 2009 5:22 17
Channel Bank 11 Bank 12 Bank 13 Bank 14 Bank 15 Bank 16 Bank 17 Bank 18 Bank 19 Bank 20
1 2 3 4 5 6
Note US TV-Ch.
542,750 519,300 526,700 531,050 536,650 519,600 525,200 534,600 524,600 526,650 544,450 523,850 529,600 535,300 539,100 527,250 528,200 538,750 529,700 536,150 545,850 526,200 533,800 537,250 544,350 530,750 535,650 539,750 532,650 541,050 549,400 527,700 534,850 540,000 547,750 532,200 538,300 543,750 539,700 545,250 551,250 531,200 539,500 545,250 550,550 538,700 546,650 546,700 542,800 549,300 552,300 532,500 541,650 547,350 551,850 541,500 547,200 553,100 547,350 553,000
26 & 27
US TV-Ch.
22 & 24
US TV-Ch.
23 & 25
US TV-Ch.
24 & 26
US TV-Ch.
25 & 27
US TV-Ch.
22 & 25
US TV-Ch.
23 & 26
US TV-Ch.
24 & 27
US TV-Ch.
22 & 26
US TV-Ch.
23 & 27
Remarque Etats-Unis
Nota EE.UU. Canales
Observação E.U.A. Canales
canaux TV
26 & 27
TV 26 & 27
TV 26 & 27
The frequency bank “U” allows the user to store frequencies that are freely selectable
Etats-Unis canaux TV
22 & 24
EE.UU. Canales
TV 22 & 24
E.U.A. Canales
TV 22 & 24
Etats-Unis canaux TV
23 & 25
EE.UU. Canales
TV 23 & 25
E.U.A. Canales
TV 23 & 25
Etats-Unis canaux TV
24 & 26
EE.UU. Canales
TV 24 & 26
E.U.A. Canales
TV 24 & 26
Etats-Unis canaux TV
25 & 27
EE.UU. Canales
TV 25 & 27
E.U.A. Canales
TV 25 & 27
La banque de fréquences « U » permet de mémoriser des fréquences sélectionnables au choix.
Etats-Unis canaux TV
22 & 25
EE.UU. Canales
TV 22 & 25
E.U.A. Canales
TV 22 & 25
Etats-Unis canaux TV
23 & 26
EE.UU. Canales
TV 23 & 26
E.U.A. Canales
TV 23 & 26
En el banco de canales «U», las frecuencias se pueden elegir libremente
Etats-Unis canaux TV
24 & 27
EE.UU. Canales
TV 24 & 27
E.U.A. Canales
TV 24 & 27
Etats-Unis canaux TV
22 & 26
EE.UU. Canales
TV 22 & 26
E.U.A. Canales
TV 22 & 26
No banco de canais «U», as frequências podem ser livremente seleccionadas
Etats-Unis canaux TV
23 & 27
EE.UU. Canales
TV 23 & 27
E.U.A. Canales
TV 23 & 27
Page 4
US_BerA_518-554MHz_532015_0109_Sp4.fm Seite 4 Freitag, 6. Februar 2009 5:22 17
Información adicional para sistemas Sennheiser de la serie evolution wireless G3
Para la transmisión se dispone de un rango de frecuencia de 36 MHz de amplitud con 1440 frecuencias de transmisión/ recepción posibles en la banda UHF.
Los transmisores y receptores cuentan con 20 bancos de canales cada uno para los que se ha preajustado una frecuencia en fábrica. Dentro de un banco de canales, los preajustes de frecuencia se encuentran libres de intermodulación entre ellos. Éstos no se pueden cambiar.
En el banco de canales «U» puede ajustar libremente y guardar frecuencias a pasos de 25 kHz. Estas frecuencias pueden no estar libres de intermodulación.
Los preajustes de frecuencia en los bancos de canales «1» a «20» se representan en la siguiente tabla.
Con la opción de menú «Reset», se pueden llamar de nuevo los siguientes ajustes de fábrica en todo momento:
Auto Lock inactivo Sensitivity SK –30 dB
SKM –18 dB Mute Mode AF On/Off (SK) Squelch low AF Out EM +18 dB Equalizer flat Guitar Tuner inactivo Name nombre de la serie Pilot Tone no se resetea con Reset User Bank no se resetea con Reset
Informações adicionais relativamente a sistemas Sennheiser da série evolution wireless G3
Para a transmissão em banda UHF, encontra-se à disposição uma gama de frequências de 36 MHz de largura com 1440 possíveis frequências de transmissão/recepção.
Os transmissores e receptores dispõem de 20 bancos de canais cada um, nos quais está predefinida, de fábrica, um frequência. Dentro de um mesmo banco de canais, as predefinições de frequência estão livres de intermodulação. Não podem ser alte­radas.
No banco de canais «U», as frequências podem ser livremente definidas e guardadas em passos de 25 kHz. Sob determinadas circunstâncias, estas podem não estar livres de intermodulação.
As predefinições de frequência nos bancos de canais «1» a «20» são enunciadas na tabela seguinte.
No item de menu «Reset» podem repor-se, em qualquer altura, as regulações de fábrica seguintes:
Auto Lock inactivo Sensitivity SK –30 dB
SKM –18 dB Mute Mode AF On/Off (SK) Squelch low AF Out EM +18 dB Equalizer flat Guitar Tuner inactivo Name nome da série Pilot Tone não é possível repor com o Reset Banco do utilizador não é possível repor com o Reset
Loading...