Sencore UMH160R Quick Installation Manual

IRD Quick Installation Guide
V1.2-N
Integrated Digital Receiver
Quick Installation Guide
2
IRD Quick Installation Guide
V1.2-N
1. Installation Instruction
1.1 Mounting unit to a 19” rack
When selecting the installation site, try to comply with the following:
z Protective Ground - The protective ground lead of the building's electrical
installation should comply with national and local requirements.
z Environmental Condition - The installation site should be dry, clean, and
ventilated. Do not use this equipment where it could be at risk of contact with water.
To avoid electric shock, make sure the rack has been correctly grounded
before switching device on the.
To mount the SMP160R unit to a 19”/42U rack, please perform the following steps:
1. Make sure the mounted rack surface is stable and can support the size and weight of this equipment.
2. For single unit mounting, use an “L” shape slide (not included in the package) to support holding the unit if necessary, and fastened with appropriate screws to each side of the chassis’ rails.
L-shape slide
3. For group pile up (no space between each unit), the unit should be placed on a flat holding bracket. No more than 5 units for each group, and leave at least one unit space
PIC-1.1-1 Grounding Jackscrew (must be connected to the rack housing)
3
IRD Quick Installation Guide
V1.2-N
between each group to ensure good air ventilation.
PIC-1.1-2
1.2 Wiring Connection
Before setting up the connection, please turn off the equipment and all other
connected external devices. The equipment and all connected external devices are required grounded. Turn on the devices only after the wiring connection is completed. Otherwise, the device may be damaged.
Follow the below connection diagram to set up cable connection:
PIC-1.2-1
z Set up cable connection for input signal: either the RF input (area 1) or ASI input (area
4).
z Set up cable connection for output signal: either through ASI (area 2) or HDMI/
1
2
5
4
3
4
IRD Quick Installation Guide
V1.2-N
CVBS/SDI (area 3)
z Set up connection for network management control: shown in area 5.
In order to ensure a smooth communication between the management PC and
the equipment, please separate the connection of management port and TS/IP output port to different switch. The switch with management port connected should be without large data processing.
The TS/IP port can work for input and output simultaneously. User only needs
to connect one RJ45 cable to the TS/IP port of the device.
1.3 Power Connection
Connect this equipment only to the power sources that are identified on the
equipment-rating label normally located close to the power inlet connector(s). Always pull the plug or the connector to disconnect a cable. Never pull on the cable itself.
To protect your valuable interests and services, equipping a UPS
(Uninterrupted Power Supply) and an AVR (Automated Voltage Regulator) to the system is highly recommended.
5
IRD Quick Installation Guide
V1.2-N
2. Operation Instructions
2.1 Powering Up & Initializations
Before powering-up the device, make sure that all cabling is correctly
connected (refer to chapter 5.2). The device is correctly connected to the power inlet and grounded.
Switch on the equipment through the back power switch, the unit is powered up and start the initialization. The LCD screen is lighted up, and display information as following:
PIC-2.1-1
The initialization takes about 30 seconds to complete.
If the unit fails to initialize and hangs at the “booting” stage, swtiching off the
device and then powering up again. If the device still fails to initialize, please contact your service representative for help.
The input/output indicator LEDs turn red after successful initialization because
of signal unlocking. After configuration on the device, corresponding LEDs shall show correct statuses.
2.2 Network Connection Setup
2.2.1 Navigation Keys Operation Instruction
Use the 6 navigation keys on front panel: Up / Down / Left / Right / Menu / Ok to
IRD
SettingSystem
6
IRD Quick Installation Guide
V1.2-N
enter the configuration menu.
z Enter “Menu”:
Press “MENU
” button to enter main menu.
z Exit Menu/Back to parent Menu
Upon completion of configuration settings, press “MENU
” button until you go back
to the Parent Menu.
You can also go back to Parent Menu directly by pressing “ESC
” button once.
z Enter Sub-Menu
Press MENU
button to enter main menu.
Select a sub-menu by pressing UP
and DOWN button.
Press OK
button on the selected sub-menu.
z To change parameter
Step 1: Enter main menu by pressing MENU
button.
Step 2: Scroll sub-menu by pressing UP and DOWN button, and press OK button
to change the selected sub-menu.
Step 3: To change parameter settings, press RIGHT
and LEFT button to move the
cursor in which change must be made.
Press UP
button and DOWN to input / select an appropriate setting, then press OK
button to save.
2.2.2 Check Out and Change the Default IP Address
z Step 1: check out the IP on the LCD screen. z Step 2: use the button on the front panel to change the IP, gateway and subnet mask.
The gateway should be the same as the management PC’s. The subnet mask should be the same as the management PC’s s. The IP and the server’s IP should be in the same section.
z Step 3: reboot the device to take effect. z Step 4: ping the new IP on PC to check whether the device can connect to the
management PC.
7
IRD Quick Installation Guide
V1.2-N
2.2.3 Configuration through WEB Management
Accessing the equipment through web can be very convenient for remote
configuration of the equipment. Relative to the front panel settings, web operation can provide a more user-friendly man-machine interface, and less limits in space. For quick installation, web operation is highly recommended. In this installation guide, operation instruction is based on web style. For front panel operation instruction, please refer to product user manual.
z Preparation before connection Open any web browser (e.g. Mozilla, internet explorer, safari etc.), input the equipment’s IP address in format: http://xxx.xxx.xxx.xxx
(xxx.xxx.xxx.xxx refers to IRD’s IP address) and press ENTER button to confirm. The browser will attempt to connect to the device. If succeed, a login page will appear (see pic-2.2-1).
z First Time Log On
o For first time log on, User Name and Password are required. Default User Name
and Password are “admin”.
PIC-2.2-1
8
IRD Quick Installation Guide
V1.2-N
User can change the password after log on the device. Please refer to chapter XXXX
of this document for the details. (Referring chapter 6.4.5 /Page 34)
Possible reasons for unsuccessful log on:
z IP address/ network mask/gateway don’t match with the management PC’s z User name/password is wrong. z The device is connected to the wrong interface.
z Main Interface Introduction
After successful log on, the following screen will display:
PIC-2.2-2
The main interface can be divided into two areas according to its functionality.
(1) Menu: It share same 6 tabs including “Status”, “Inputs”, “Outputs”, “CA”, “System”
and “Reset”.
2
9
IRD Quick Installation Guide
V1.2-N
(2) Parameter setting and configuration area: The parameters of the equipment are
shown and configured here by selecting corresponding tabs. This is the main operation area of the WEB management.
2.3 Quick Configuration on Key Parameters (Base
Model)
2.3.1 Check “Status” tab
Click the “status” tab on the left area and then the status information will show on the right interface as following, where you can check the main information of the device.
PIC-2.3-1
2.3.2 Configure parameters of signal input modules
Firstly, click the “receiver” menu to obtain the “receiver” interface, where you can configure the detailed parameter of inputs,there are two kinds siganls to be choose:tuner and ASI, just set the right one you need as source as follows:
10
IRD Quick Installation Guide
V1.2-N
PIC-2.3-2
2.3.2.1 Tuner IN
To receive the signal from satellite via the device, connect the satellite siganl to the tuner port and operate as follows:
-Step one:
PIC-2.3-3
Choose the signal as input ,there are three options: ASI, Tuner1 and Tuner2, here we choose tunel as siganl source. After confirming the signal source, it is able to go for detailed parameter coonfifuration.
-Step two:
Stepone
Steptwo
11
IRD Quick Installation Guide
V1.2-N
PIC-2.3-4
Configure the dual RF receiver parameters including the Satellite Frequency, Symbol Rate, LNB Frequency , and LNB Voltage (Polarization) with accurate values to ensure a successful receiving. You can get the value for the parameter from the satellite programs provider.
‐Step three
After setting, press the “Submit” button to save the settings, and click “Refresh” button to refresh the screen to check if the signal is locked.
2.3.2.2 ASI IN
PIC-2.3-5
-Step one
When choosing the ASI signal as input, check the ASI siganl first to ensure a high-quality source, then connect the ASI signal to the ASI interface on rear panel.
-Step two
In the “receiver” interface, choose the ASI signal as signal source and click “submit” button to confirm. After that click “refresh” button to refrsh the status page to check if the signal is locked.
12
IRD Quick Installation Guide
V1.2-N
2.3.3 Configure parameters of signal output modules
2.3.3.1 Decoder OUT
The device allows various signal outputs, including HDMI, SDI, CVBS and balanced audio. In this interface, user can view and configure the decoding output program information, includingProgram, CAM, Video, Audio and Subtitle. There are six steps to ensure an available and stable program output.
PIC-2.3-6
-Step one: Choose Programs
This interface, in “Program” section, you can determine which program to transmit by choosing the program’s name.
PIC-2.3-7
If the input signal is not locked or searched, user cannot do any setup if the
13
IRD Quick Installation Guide
V1.2-N
“program” section shows empty.
The device decoding output is via its CVBS or HDMI output ports. For each
time only one program can be set to decoding output.
-Step two: scrambling configuration
By changing the CAM operation, you can determine whether to descramble the program or not. Including Bypass, CI SLOT1, CI SLOT2 and DELETE.
PIC-2.3-8
-Step three: VIDEO Parameter Then configure the video parameter such as Video Standard, Aspect ratio Conversion and Output Video resolution, if you don’t know the accurate value just keep the default value, as follows:
PIC-2.3-9
The decoder output video resolution should meet with the monitor resolution
setting to avoid and display issue.
-Step five: AUDIO Parameter In addition, to ensure an available output, configuring the information of Audio such as volume, and audio language is necessary. The Audio Volume shall be more than 0, or it may have no audio output.
14
IRD Quick Installation Guide
V1.2-N
PIC-2.3-10
-Step six: Confirmation
After completing configuration on the “program setup page” and press “Submit” button, connect a TV or monitor to the HDMI/CVBS port to check if the program has been decoded.
2.3.3.2 ASI OUT
The ASI interface transmits the received signals (tuner or ASI) out for further process. To guarantee the successful transmission, make sure the signals are locked.
2.3.4 Program IN/OUT configuration in “Program Info” tab
2.3.4.1 CI Descrambling
If there are encrypted programs, you can use CI module to descramble the programs. Click the “CI” menu on the left section to get the CI configuration interface. It is able to manage the configuration setting related to the device decryption and descrambling capability. Choose a CAM card or BISS to descramble the encrypted programs as follows:
PIC-2.3-11
15
IRD Quick Installation Guide
V1.2-N
o COMMON INTERFACE is used to interface between the pay-per-view card and
the receiver. This is a defined standard that enables the addition of Conditional Access Module (CAM) in a DTV receiver to adapt it to different kinds of cryptography.
o CI Bitrate Mode: Set the max output bit rate of the CAM. o BISS (Basic Interoperable Scrambling System): is a satellite signal scrambling
system developed by the European Broadcasting Union
and a consortium of
hardware manufacturers.
2.3.5 Check “Status” again
Turn to status page to check if the configuration has taken into effect.
PIC-6-3-12 This is the brief introduce of UMH 160R-Base/L quick installation, if need more detail or complete information for the device please refer to the user manual.
2.4 Quick Configuration on Key Parameters (for
multiplexer, QAM, IP and transcoding model)
2.4.1 Check “Status” tab
Click the “status” tab on the left area and then the status information will show on the right
16
IRD Quick Installation Guide
V1.2-N
interface as following, where you can check the main information of the device.
PIC-2.4-1
2.4.2 Configure parameters of signal input module
2.4.2.1 Tuner IN
To choose signals from tuner as inputs, please operate as follows:
-Step one
Beforestartingthereceiving,checktheconnectiontoseeifthesatellitesignalishighqualityand wellconnectedtotheRFportonrearpanel. Click DVB-S/S2 menu in left menu and it will get
the configuration page (shown as PIC-2.4-2), where it is able to set the signal receiving parameter.
PIC-6-4-2
17
IRD Quick Installation Guide
V1.2-N
-Step two
Get the accurate value of the satellite frequency, symbol rate and LNB frequency from satellite program provider and input them to the corresponding tab. After configuration, press submit button to take it into effect.
PIC-2.4-3
Step three
After that, press the “Status” menu in the left area to refresh the receiving information to check if the signal is locked.
PIC-2.4-4
2.4.2.2 ASI IN
When choosing the ASI signal as input, check the ASI siganl first to ensure a high-quality source, then connect the ASI signal to the ASI interface on rear panel. The device will search and lock it automatically . If su cceed, the status will show “Lock” in green, otherwise it shows “unlock” in red.
18
IRD Quick Installation Guide
V1.2-N
PIC-2.4-5
2.4.2.3 IP IN
To choose IP stream as input source, click the sub-menu IP in “INPUTS” menu. Then it can turn to the IP parameter interface.
-Step one
Then, set the “Enable” item to be “ON” to access the IP channel, set the source IP address, Source Port and Protocol. The Source IP address shall be in the same section with that of signal source; the Source Port and the protocol shall stay same with that of signal source. (Refer to chapter 2.2.2/ Page 6)
PIC-2.4-6
-Step two
Press “Submit” button to confirm the parameter. Then press the “Status” menu in the left area to refresh the receiving information to check if the signal locked.
19
IRD Quick Installation Guide
V1.2-N
PIC-2.4-7
2.4.3 Configure parameters of signal output modules
2.4.3.1 Decoder Out
Click the “Decoder Setup” menu and it will turn to the configuration page, where you can set the parameter of video and audio. Set the value to be compliant with the monitor or TV or just keep the default value.
PIC-2.4-8
After completing of the configuration, click “Submit” button to get the parameter into effect.
Keep in mind that only one program can be decoded and outputted via
HDMI/CVBS/YPbPr.
2.4.3.2 ASI Out
20
IRD Quick Installation Guide
V1.2-N
PIC-2.4-9
Click the sub-menu “ASI” in Outputs menu and it will show the ASI configuration item in the right interface, where it is able to set the bit rate of ASI output as following:
PIC-2.4-10
After that, click “submit” button to confirm the configuration.
2.4.3.3 IP Out
Click the Sub-menu “IP” in “Outputs” menu and it will show the IP configuration interface, containing the main parameter of output IP streams. There are two channels for output, you are able to set both of them. At first, set the “Enable” label of the channel you need to switch on. Then, modify the Dest IP Address, Dest Port and protocol to be same as the destination device.
PIC-2.4-11
21
IRD Quick Installation Guide
V1.2-N
2.4.4 Program IN/OUT configuration in “Program Info” tab
Parameters of input and output programs can be configured, just click the “programs” button on the left bar. Then it will turn to the programs information interface, in which parameters of the program can be modified and check.
PIC-2.4-14
Input Program Configuration:The “Input Program Configuration” is on the left side
of the window. It displays all the information input module and the received input streams
Output Program Configuration:In the “Output Program Configuration” window, it shows the ports which can be set to transmit output stream. The programs set to be outputted are shown in the submenu of each port.
Operation Buttons: This area contains four function buttons: Refresh, Apply, Save and ClearAll. These four buttons are used to make the configuration in to effect. Refresh: clicked this button to refresh all the program information. Apply: to validate the configuration of the programs, but it can’t provide save function. Save: to validate and save the configuration of the programs. ClearAll: to clear all the configuration of programs and TS.
How to dispose the input programs:
To get the input programs, choose the port that is connected with input streams and right
1
2
3
22
IRD Quick Installation Guide
V1.2-N
click the TS. Then a prompt menu will appear as shown below, select “SCAN TS” it can be DVB or ATSC depending on the source.
PIC-2.4-15
After completing the scan, all the input programs of that port will be scanned and displayed as follows:
PIC-2.4-16
How to configure the output programs:
Firstly, select the port which was assigned to transmit the output stream. Right click the TS in that port and a pop-up menu will appear. Click “ADD TS” and a pop-up menu will appear shown as follows:
23
IRD Quick Installation Guide
V1.2-N
PIC-2.4-17
Secondly, Input the “Original Network ID” and “TS ID” for the channel, and click the “OK” button. Then input “Original Network ID” and “TS ID” will be assigned to the selected output TS (channel).
PIC-2.4-18
In addition, when editing icon was clicked, TS name, network ID and TS ID can be modified. Existing TS can also be deleted by clicking the cross icon, shown as follows:
PIC-2.4-19
Then the input programs shown in the left frame can be dragged to the right frame as output as the picture shows:
PIC-2.4-20
24
IRD Quick Installation Guide
V1.2-N
After completing the configuration, click “Apply” button to enforce it or “Save” button
to enforce and save it.
2.4.5 Change the password
Choose “User management” menu and you will get the operation interface. Select the username and input the old password correctly, then you are able to change the password. After inputting the new password, please click submit button to enforce the configuration.
PIC-2.4-21
2.4.6 Check “Status” again
Turn to status page to check if the configuration has come into effect.
25
IRD Quick Installation Guide
V1.2-N
PIC-2.4-22
Quick installation is finished till this step. If you need more details or complete information of the device please refer to the user manual in attached user disc.
Loading...