Sencore is an engineering leader in the development of high-quality signal transmission solutions for the
broadcast, cable, satellite, IPTV, and telecommunications markets. The company's world-class portfolio
includes video delivery products, system monitoring and analysis solutions, and test and measurement
equipment, all designed to support system interoperability and backed by best-in-class customer support.
Sencore products meet the rapidly changing needs of modern media by ensuring the efficient delivery of
high-quality video from the source to the home. More information about Sencore is available at the
company’s website, www.sencore.com
All trademarks and registered trademarks mentioned herein are the property of their respective owners.
.
Page 2 (306)
Date
Version
Description
Author
01/09/12
1.0
Initial Release
ACD
12/01/14
2.0
DMG 3200 Release
ACD
Revision History
DMG 3200/3100/3000 – User Manual
Page 3 (306)
DMG 3200/3100/3000 – User Manual
FCC Class A Information
The DMG 3200/3100/3000 has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. T hese limits are designed
to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his or her own expense.
Shielded cables must be used with this unit to ensure compliance with the Class A FCC
limits.
Warning: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate the
equipment.
Page 4 (306)
DMG 3200/3100/3000 – User Manual
WARNING
PLEASE OBSERVE THESE SAFETY PRECAUTIONS
There is always a danger present when using electronic
equipment.
Unexpected high voltages can be present at unusual locations in defective equipment
and signal distribution systems. Become familiar with the equipment that you are
working with and observe the following safety precautions.
• Every precaution has been taken in the design of your 3200/3100/3000 to ensure
that it is as safe as possible. However, safe operation depends on you the
operator.
• Always be sure your equipment is in good working order. Ensure that all points of
connection are secure to the chassis and that protective covers are in place and
secured with fasteners.
• Never work alone when working in hazardous conditions. Always have another
person close by in case of an accident.
• Always refer to the manual for safe operat ion. If you have a question about the
application or operation call SENCORE for assistance.
• Never allow your equipment to be exposed to water or high moisture
environments. If exposed to a liquid, remove power safely (at the breaker) and
send your equipment to be serviced by a qualified technician.
Page 5 (306)
DMG 3200/3100/3000 – User Manual
1) Documentation CD
2) Quick Install Guide
3) AC Power Cable
Package Contents
The following is a list of the items that are included along with the DMG 3200/3100/3000:
1. User Manual
2. Quick Install Guide
3. AC Power Cable (2 for DMG 3200 and 3000, 1 for DMG 3100)
Note: If any option cables were ordered with the DMG 3200/3100/3000, they will be
included in the box as well.
If any of these items were omitted from the packaging of the DMG 3200/3100/3000
please call 1-800-SENCORE to obtain a replacement.
12.3Adding, Replacing, or Removing Modules ..................................................................... 298
12.4Importing and Exporting Chassis Configuration ............................................................. 300
12.5Restoring the Default IP Address ................................................................................... 301
12.6Restoring the Default IP Address for 1RU (3200). ......................................................... 302
12.6.1Resetting IP address using USB Cable ..................................................................... 302
12.6.2Resetting IP address with DIP switch: ....................................................................... 302
Appendix A – Notices ........................................................................................ 304
Appendix B – Alarm messages......................................................................... 304
Appendix C – Warranty ..................................................................................... 304
Appendix D – Support and Contact Information ............................................. 305
Page 11 (306)
DMG 3200/3100/3000 – User Manual
1 Introduction
Thank you for purchasing the DMG 3200/3100/3000. This manual describes how to install,
configure, and operate your new equipment. It is written for professional operators of video distribution
systems and assumes a prerequisite level of technical knowledge.
Page 12 (306)
DMG 3200/3100/3000 – User Manual
2 Installation and Safety
2.1 Installation and Safety
The unit is designed to offer operators reliabi lity and flexibility. It consists of a chassis in which a
number of modules can be installed. To cater to specific system requirements, the chassis can be
configured to host functional modules best suited for a given scenario.
Sencore products can be delivered in different chassis variations - 1RU chassis and a 4RU
chassis. The produc t models DMG 3000 and DM G 3200 represents the 4RU chassis, while the
product models DMG 3100 and DMG 3200 represents 1RU chassis.
2.1.1 The 4RU Chassis
The 4RU chassis consists of a total of 18 slots all of which can host functional modules. Slot
number 0 is dedicated to host the switch module and slot number 17 can only host multi-slot input
modules. Alternatively a second sw itch module can be placed in slot 17 for some redundancy
configurations. The remainin g 16 slots are ident ical and can be occ upied by any of th e functional
modules available. A 4RU chassis including a mandatory switch module, power supply
connectors, and module slots is shown in Figure 2.1 and 2.2. Power modules and fan m odules
are inserted from the back (figure 2.3 showing the DMG 3200 4RU).
Figure 2.1 – 4RU chassis (DMG 3000) with power connectors, switch module and available
Page 13 (306)
slots.
DMG 3200/3100/3000 – User Manual
DMG 3200
MODULAR
HI-DENSITY
HOT-SWAP
Status
Control
SWITCH
IPIO Control
Sync In
Data A Data B
Figure 2.2 – 4RU chassi s (DMG 3200) with front view
Figure 2.3 – 4RU chassi s (DMG 3200) with rear view
2.1.1.1 Product models
4RU chassis models: DMG 3000 and DMG 3200
2.1.1.2 Ventilation
The 4RU chassis with Telco mounting has forced air flow from front to back in the chassis,
allowing for multiple units to be stacked above each other with no space in between. However,
adequate space must be provided in front of and behind the unit for effective ventilation. For
Broadcast mounting, air flow will be from back to front.
2.1.1.3 Replacing the power supply m odule
The 4RU chassis can be installed with one or two power supply modules (DMG 3200 always
comes with two power supply modules). The modules can be exchanged from the rear of the
unit. The chassis delivered with a single power module can be updated by acquiring additional
power module.
If power is lost in one of the Power supplies, the other can feed the entire chassis. It is
recommended to connect each input power at different circuits.
Page 14 (306)
DMG 3200/3100/3000 – User Manual
DMG 3200
DATA A
DATA B
CONTROL
Slot #
1
Slot #
2
Slot
#3
Slot #
4
Slot
#5
Slot #
6
2.1.2 1RU Chassis DMG 3200
The 1RU chassis for the DMG 3200 holds of a total of 6 slot positions plus a slot for the
Switch/IP module. The Switch/IP module is inserted in the front of the chassis, while the
modules for the other 6 positions are inserted in the back of the chassis. All modules are hotswappable, including power supplies and the fan module in front.
The 1RU chassis is equipped with dual 400W AC or 500W DC power supplies
Figure 2.5 shows the front and rear view of the 1RU chassis including a mandatory switch
module, power supply connectors, and module slots.
Figure 2.5 - 1RU chassis for DMG 3200 with dual power, switch module and available slots;
front and rear view.
This chassis can hold 2 power supply modules for redundancy purpose
2.1.2.1 Ventilation
This DMG 3200 has forced air flow from front to back allowing for multiple units to be stacked
above each other with no space in between. However, adequate space must be provided in
front of and behind the unit for effective ventilation.
The DMG 3200 has 6 fans in front. Fan speed is temperature controlled. If one fan fails,
remaining fans will increase speed to compensate. The whole Fan module, containing all 6
fans, can be hot swapped. If, during fan module replacement, the temperature on the inserted
modules exceeds a certain critical temperature, the unit will shut down, to prevent damage of
the inserted modules.
2.1.2.2 Replacing the power supply m odule
This 1RU chassis can be installed with one or two hot swappable power supply modules. The
modules can be exchanged from the rear of the unit. The chassis delivered with a single power
module can be updated by acquiring additional power module.
If power is lost in one of the Power supplies, the other can feed the entire chassis. It is
recommended to connect each input power at different circuits.
Page 15 (306)
DMG 3200/3100/3000 – User Manual
and key, or any other safety device, and in addition the site will be
2.1.3 Safety Considerations
The unit must be connected to a grounded power connection. The power input connector is a
disconnect device. To remove the power from the device, the power cables needs to be
physically removed from the power input connector.
Mandatory Safety Instr uctions
1 The equipment must be installed by a qualified person.
2 For that equipment with grounding, connect the driver before connecting the power
cord. So opposite the power cord must be removed before removing the driver of
the ground.
3 The equipment must be installed in a restricted area where:
•Only qualified technicians have access or who know the most important
safety measures.
•Access to the area where the devices are installed will be using a tool, lock
controlled by an authorized person.
Page 16 (306)
DMG 3200/3100/3000 – User Manual
2.1.4 Installation
2.1.4.1 Power supply rating
The 4RU chassis is supplied with either a 100-240V AC 50/60 Hz power or -48V DC power.
The 100-240V AC 50/60 Hz power supply is rated for maximum 300W, 400W or 800W
48V DC power is rated for maximum 400W. Figures 2.6. 2.7, 2.8, 2.9, 2.10, 2.11 and 2.12
below shows the power supply inlets.
The 1RU chassis is supplied with a 100-240V AC 50/60 Hz power rated for maximum 200W
for product models DMG 3100.
The 1Ru chassis, product model DMG 3200, is supplied with single or dual 100-240V AC, 4763Hz , 400W power, or with single or dual -48V DC, 500W power.
2.1.4.2 4RU chassis with 300 and 400W AC Power
The chassis can be hold two power supplier for redundancy and has independent power inlets
for the two supplies.
1
. The -
Figure 2.6 - Power Input for 4RU chassis with 300 and 400 Watt AC power
1
Contact Sencore for more information.
Page 17 (306)
DMG 3200/3100/3000 – User Manual
2.1.4.3 4RU chassis with 800W AC Power
The chassis has two power supplies for redundancy with independent power inlets. The
power supplies and power inlets are located at the back of the chassis.
Figure 2.7- Power input for 4RU chassis with 800W power supplies
Page 18 (306)
DMG 3200/3100/3000 – User Manual
2.1.4.4 4RU chassis with 400W DC (-48Volt) Power supply
The chassis can be hold two power supplier for redundancy and has independent power inlets
for the two supplies.
Figure 2.8– Front plate of dual 48V Power Supply in a DMG 3000
Figure 2.9 - Layout of 48V DC Power Supply Connector
2.1.4.5 1RU chassis Product model DMG 3200 with AC power
The power input connectors are located at the back of the unit.
Figure 2.10 Power Input Connector for 1RU Chassis, product models DMG 3200 with AC power
Page 19 (306)
DMG 3200/3100/3000 – User Manual
0 Volt
-48
volt
Chassis Ground
2.1.4.6 1RU chassis Product model DMG 3200 with DC power
The power input connectors are located at the back of the unit.
Figure 2.11 Power Input Connector for 1RU Chassis, product models DMG 3200 with DC power
2.1.5 Information on Disposal
This product must not be disposed of with other household waste. According
to the WEEE-directive, everyone that sells electrical and electronic products
shall ensure that the same products are disposed of in an environmentally
sound manner.
2.1.6 Laser Safety
The Optical SFP modules used in the DMG 3000/3100/3200 products are classified as class 1
laser products according to IEC 60825-1 and are classified as class 1 laser products per
CDRH, 21 CFR 1040 Laser Safety requirements.
Depending on the products configuration, the DMG 3000/3100/3200 products can be
equipped with multiple insertion modules containing housing for optical SFPs.
When installing SFP modules, please ensure that the module be placed in the housing present
at the front of the IP input/output module. Once inserted, the SFP module will become active.
Page 20 (306)
DMG 3200/3100/3000 – User Manual
Max output power
(1)
Finisar
FTLF8519P2xCL
850 nm
-3 dBm
Finisar
FTLF8519P2xNL
850 nm
-3 dBm
Finisar
FTLF8519P2xTL
850 nm
-2.5 dBm
Finisar
FTLF1318P2xCL
1310 nm
-3 dBm
Finisar
FTLF1318P2xTL
1310 nm
-3 dBm
Finisar
FTLF1419P1xCL
1310 nm
5 dBm
Finisar
FTLF1518P1BTL
1550 nm
5 dBm
Finisar
FTLF1519P1xCL
1550 nm
5 dBm
Finisar
FTLF1519P1xNL
1550 nm
5 dBm
Finisar
FTLF1619P1xCL
1550 nm
5 dBm
Finisar
FWLF15217Dxx
1471, 1491, 1511,
1591, 1611
5 dBm
Finisar
FWDM16197Dxx
1471, 1491, 1511,
1591, 1611
5 dBm
Avago
Technologies
AFBR-5710Z
850 nm
-3 dBm
Avago
Technologies
AFBR-5715Z
850 nm
-3 dBm
Avago
Technologies
AFCT-5710Z
1310 nm
-3 dBm
Avago
Technologies
AFCT-5715Z
1310 nm
-3 dBm
OCP
TRXAG1SX
850 nm
-4 dBm
OCP
TRPEG1KVX-
E1G
1550 nm
5 dBm
(1) Class 1 Laser Safety per FDA/CDRH and EN (IEC) 60825 regulations
2.1.6.1 FDA/CDRH Compliant SFP modules
The below list of Optical SFP modules have been selected with regards to the FDA/CDRH
laser safety requirements as the only optical modules allowed used with the Sencore products
in the USA, and any other countries and states that require compliance according to
FDA/CDRH laser safety regulations.
Manufacturer Model wave length [nm]
2.1.6.2 Warning: Radiation
1531 1551, 1571,
1531 1551, 1571,
Caution – use of controls or adjustment or performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Page 21 (306)
2.1.6.3 Labels
DMG 3200
MODULAR
HI-DENSITY
HOT-SWAP
Status
Control
SWITCH
IPIO Control
Sync In
Data A Data B
DMG 3200
DATA A
DATA BCONTROL
The following illustrations show the labels attached to the Sencore products, according to
the standards.
A classification label is attached to the top cover of the DMG 3000/3100/3200 products.
DMG 3200/3100/3000 – User Manual
Figure 2.12 - classification label
3 Physical Module Configuration
3.1 Connecting switch modules
Configuration, management and monitoring of your Sencore unit is done via the management
port on the switch module. The switch module will contain the database for the full configuration
of the unit. One switch module (in some configuration two switch modules) must be installed in
all 1 RU and all 4 RU chassis.
Please refer to product datasheets for module identification.
3.1.1 Switch module with MMI
The switch module is equipped with one electrical connector (RJ45) for management.
Automatic sensing of 10/100/1000Mbit Ethernet connections is supported. For a 1000Mbit
connection, the Ethernet cable must be a category 6 cable.
The management port should be connected to your management network. Please refer to
section 4 for configuration.
3.1.2 Switch module with MMI and IP IO
Page 22 (306)
DMG 3200/3100/3000 – User Manual
The switch module with management and two data ports is equipped with three electrical
connectors (RJ45) or one electrical connector (RJ45) and two SFP connectors. Two RJ45
electrical connectors or two SFP connectors are for data. The last RJ45 electrical connector is
for management
Automatic sensing of 10/100/1000Mbit Ethernet connections is supported on all RJ45 ports. For
a 1000Mbit connection, the Ethernet cable must be a category 6 cable.
The management port should be connected to your management network and the data port to
you data network carrying the video streaming content. Please refer to section 4 for
configuration.
Each port have a unique IP address and both data ports can be used at the same time as
wither 2 IP input ports (seamless or standalone), 2 IP output ports (cloned or standalone) or 1
IP input and 1 IP output port.
3.2 MMI MicroSD Installation
In order to enable Logo Insertion for the Encoder modules, a MicroSD card will need to be
installed in the MMI module. This will require physical removal of the MMI module from the unit.
Once the module has been removed, you will need to take the MicroSD card provided by
Sencore and insert this into and ‘click’ this into the MicroSD holder as shown below:
Figure 3.1 – MicroSD slot
In order to remove the MicroSD card, this can be pushed and then removed.
3.3 Connecting Input Signals
Please refer to product datasheets for module identification.
3.3.1 IP Input
This applies to the following modules::
• Standalone IP Input
• Dual IP module (Input mode)
The standalone IP input module is equipped with two electrical connectors (RJ45) and one SFP
connector. One RJ45 electrical connector and the SFP connector are for data. The second
Page 23 (306)
RJ45 electrical connector marked “control” is not in use. It is not required to configure the IP
address or connect the port to the IP network.
The Dual IP module is equipped with two electrical connectors (RJ45) and two SFP connector.
Automatic sensing of 10/100/1000Mbit Ethernet connections is supported. For a 1000Mbit
connection, the Ethernet cable must be a category 6 cable.
The IP address for both the electrical (RJ45) and the optical (SFP) connectors for data is the
same. Consequently both connectors cannot be used simultaneously. These inputs are
automatically activated by IP connection. The first port activated (by establishing a link to the
router) will be the active port. To activate the other port, remove the cable from the active port.
3.3.2 ASI Input
Each ASI input module has three independent ASI inputs. The ASI connector is a 75Ω BNC
connector. The maximum input rate per connector is 212Mbit/s in burst mode.
The ASI module is equipped with an electrical connector (RJ45) marked “control” that is not in
use. It is not required to configure the IP address or connect the port to the IP network.
3.3.3 DVB-S/S2 Input
DMG 3200/3100/3000 – User Manual
The DVBS-S/S2 supports both DVB-S (QPSK) and DVB-S2 (with DVB-S2 license). Each DVBS/S2 input module has 4 independent L-Band inputs. Each input is a 75Ω F that can be
connected either directly to an LNB, an L-Band distribution amplifier, or switch. The maximum
input level is -25dBm. The recommended input level is between -30dBm and -40dBm.
One ASI output port is available for monitoring. Any of the four L-Band inputs can be copied to
the ASI output without affecting the services in use. The ASI connector is a 75Ω BNC
connector.
The DVB-S/S2 module is equipped with an electrical connector (RJ45) marked “control” that is
not in use. It is not required to configure the IP address or connect the port to the IP network.
3.3.4 COFDM Input
Each COFDM input module has one 75Ω F connector. The input is distributed to four tuners
internally, so each module can receive four independent frequencies. The maximum input level
is -15dBm. The recommended input level is between -30dBm and -50dBm. (An older version of
this module exists with different input levels.)
One ASI output port is available for monitoring. Any of the four COFDM inputs can be copied to
the ASI output without affecting the services in use. The ASI connector is a 75 Ω BNC
connector.
Page 24 (306)
The COFDM module is equipped with an electrical connector (RJ45) marked “control” that is
not in use. It is not required to configure the IP address or connect the port to the IP network.
3.3.5 DVB-T/T2 Input
Each DVB-T/T2 input module has one or four 75Ω F connector. For the module having one
input connector, the input is distributed to four tuners internally, so each module can receive
four independent frequencies. For the module with 4 inputs, each input is directly connected to
a tuner. The maximum input level is -10dBm (both modules). The recommended input level is
between -20dBm and -40dBm (optimal lever will depend on modulation used).
3.3.6 QAM A/C Input
Each QAM input module has one 75Ω F connector. The input is distributed to four tuners
internally, so each module can receive four independent frequencies. The maximum input level
is -15dBm. The recommended input level is between -30dBm and -50dBm.
One ASI output port is available for monitoring. Any of the four QAM inputs can be copied to the
ASI output without affecting the services in use. The ASI connector is a 75Ω BNC connector.
The QAM module is equipped with an electrical connector (RJ45) marked “control” that is not in
use. It is not required to configure the IP address or connect the port to the IP network.
DMG 3200/3100/3000 – User Manual
3.3.7 8VSB Input
Each 8VSB input module has four independent 75Ω F connectors.
One ASI output port is available for monitoring. Any of the four 8VSB inputs can be copied to
the ASI output without affecting the services in use. The ASI connector is a 75Ω BNC
connector.
The 8VSB module is equipped with an electrical connector (RJ45) marked “control” that is not in
use. It is not required to configure the IP address or connect the port to the IP network.
3.3.8 QAM-B Input
Each QAM-B input module has four independent 75Ω F connectors.
One ASI output port is available for monitoring. Any of the four QAM-B inputs can be copied to
the ASI output without affecting the services in use. The ASI connector is a 75Ω BNC
connector.
The 8VSB module is equipped with an electrical connector (RJ45) marked “control” that is not in
use. It is not required to configure the IP address or connect the port to the IP network.
3.3.9 SDI Encoder
The SDI Encoder module has 4 BNC inputs that vary in functionality depending on the mode.
These functions are as follows:
• SD Encoder – Port A, B, C and D are in SDI mode and link to the 4 corresponding
• HD Encoder – Port A and B are in HD-SDI mode and link to the 2 corresponding
Page 25 (306)
internal encoder ports
internal encoder ports
DMG 3200/3100/3000 – User Manual
•HD + AES Encoder – Ports marked HDSDI A and AES A link to channel A internally
while HDSDI B and AES B link to channel B
Page 26 (306)
DMG 3200/3100/3000 – User Manual
Pin #
Function
1
A Right +
2
A Right -
3
B Right +
4
B Right -
5
GND
6
C Right +
7
C Right -
8
D Right +
9
D Right -
10
GND
11
GND
12
AES 1 +
13
AES 1 -
14
GND
15
AES 2 +
16
AES 2 -
17
GND
18
GND
19
A Left +
20
A Left -
21
B Left +
22
B Left -
23
C Left +
24
C Left -
25
D Left +
26
D Left -
3.3.10 Analog Encoder
The Analog encoder module has 4 High Density BNC input ports which correspond to the
internal ports. As well as this, there is one HD DSUB 26 male connector for audio. The pin-out
for this is as follows:
Page 27 (306)
DMG 3200/3100/3000 – User Manual
Data from backplane
MOD 1
MOD 2
MOD 3
MOD 4
QAM Modulator board
The QAM modulator consists of
four modulator chips, each
carrying up to
4 carriers. The
frequency is set only for the first
carrier of each modulator. The
remaining three carriers per
modulator follow regular spacing.
3.4 Connecting Output Signals
3.4.1 IP Output
This applies to the following modules:
• Standalone IP Output
• Dual IP module (Output mode)
The standalone IP output card is equipped with both an electrical connector (RJ45) and one
optical (via the SFP module) for data. The RJ45 connector marked “control” is not in use. It is
not required to configure the IP address or connect the port to the IP network.
The Dual IP module is equipped with two electrical connectors (RJ45) and two SFP connector.
Automatic sensing of 10/100/1000Mbit Ethernet connections is supported. For a 1000Mbit
connection, the Ethernet cable must be a category 6 cable.
The IP address for both the electrical (RJ45) and the optical (SFP) connectors for data is the
same. Consequently, both connectors cannot be used simultaneously. These inputs are
automatically activated by IP connection. The first port activated (by establishing a link to the
router) will be the active port. To activate the other port, remove the cable from the active port.
3.4.2 ASI Output
Each ASI output module has four independent ASI outputs. The ASI connector is a 75Ω BNC
connector. The maximum output rate per connector is 212Mbit/s in burst mode.
3.4.3 QAM Output
Each QAM output module has two 75Ω F connectors which carry up to sixteen frequencies.
Page 28 (306)
Figure 3.2 - QAM Modulator
DMG 3200/3100/3000 – User Manual
3.4.4 COFDM Cable Output
Each COFDM output module has two 75Ω F connectors which carry up to four frequencies.
3.4.5 DVB-T/T2 Output
The DVB-T/T2 output module has 4 50 Ohm BNC outputs, two for output A and two for output
B. Both outputs have a RF and Test port. The RF port will output the level configured in the
system while the Test port will be 20 dB lower and can be used for monitoring.
3.4.6 DVB-S/S2 Output
There are two variations of the DVB-S/S2 output module:
•L-Band Output – This module has two SMA RF outputs (50 Ohm), one for each of the
output channels A and B, and two monitor ports which are F-Type connectors (75
Ohm). The RF level of the monitor ports is 20 dB below that configured in the GUI for
the RF outputs.
The RF output can be muted with an external unit by applying 5V to the mute
connector. Channel A and Channel B can be muted individually. The connector for
Mute is a 2.5 mm headphone jack. For more information on this functionality, contact
Appear TV’s Support Team.
•IF Output – This module has 4 F-Type connectors which are 75 Ohm outputs. For
each port there is a RF and Test port. The RF port corresponds to the output power
level configured in the GUI, while the Test is the same level -20dB.
4 Administrative Settings Configuration
This chapter describes how to conduct initial configuration of the unit, such as setting its IP
address, changing the GUI’s password, setting the unit’s time as well as handling licenses for
the modules in the unit.
4.1 Accessing the Web Interface
All modules in the unit are controlled via the web interface provided with it. The unit Man
Machine Interface (MMI) software runs on the switch module via the connector marked as
“Control”
Default MMI IP address is 192.168.1.100. To change the network settings of the device please
follow the steps described below.
Connect a PC directly to the device (the Ethernet port marked “Control” on the switch module)
with an Ethernet cable.
Set the IP address of the Ethernet adapter of the PC to a fixed address in the same segment
(e.g. 192.168.1.99). Refer to the operating system’s manual for details on setting the IP address
on the PC.
Start an internet web-browser and type 192.168.1.100 in the address field.
Page 29 (306)
DMG 3200/3100/3000 – User Manual
Ensure that caching is disabled in the web browser.
If you have previously connected to a unit with the same IP address, the ARP table
on your computer might be inaccurate. To delete the old ARP entry, type arp-d
192.168.1.100 in a command prompt.
Page 30 (306)
Loading...
+ 276 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.