Seiko H024A Technical Manual

Page 1
Movement
Item
H024A
Jewels
Cal. No.
[SPECIFICATIONS]
Alarm test system
Sound for button operation confirmation
Battery life indicator
Additional mechanism
Monthly rate within normal temperature range: less than 15 secondsLoss/gain
Nil
Regulation system
Use 10-second gate.Measuring gate by quartz tester
SB-BU (SR1130W) Battery life is approximately 3 years. Voltage: 1.55V
Battery
(x 1.2)
Movement size
Outside diameter
ø31.0 mm
29.0 mm between 3 o’clock and 9 o’clock sides
28.5 mm between 12 o’clock and 6 o’clock sides
ø30.0mm
29.0 mm between 3 o’clock and 9 o’clock sides
28.5 mm between 12 o’clock and 6 o’clock sides
Casing diameter
5.5 mm
Height
Analogue section Digital sectionTime indication
Driving system
Multiplex driving system
Step motor, 1 piece
2 hands (Hour and minute hands)
Nematic Liquid Crystal, FEM (Field Effect Mode)
Time/calendar display
• Hour, minute and second
• Selection of 12h/24h-format indication
• Year, month, date, day of the week and fully automatic calendar between the year 2006 and 2055
Stopwatch display
•Hour, minutes, seconds and 1/1000 seconds
• Up to 23 hours 59 minutes 59 seconds and 999
• Data recall function
Alarm display
• Daily alarm (2 channels)
Timer
• Up to 23 hours and 59 minutes
Time display
• Hour and minute hands, two hands straight 10-second increments
Display system
Cal. H024A
2 jewels
PARTS CATALOGUE / TECHNICAL GUIDE
Page 2
PARTS CATALOGUE
Cal. H024A
2/7
For the part 6, please see the remarks on the following pages.
Disassembling procedures Figs. : Reassembling procedures Figs. : Lubricating : Types of oil Oil quantity
Moebius A
Moebius F
Silicone Oil 500,000 c.s.
Normal quantity
* Do not disassemble the
buttons except when they need to be replaced.
Case back
Case back gasket
Movement
Hour, and minute hands
Dial
Button spring clip
Piezoelectric element
Button D
Button C
Button B
Button A
6
7
1
2
4
5
Dial ring
Case ring
3
1
1
ed
ed
(AO-3) (AO-2)
Page 3
Cal. H024A
PARTS CATALOGUE
3/7
8
9
qa
qs
qd
qf
qg
q;
qh
qj
qk
w;
wa
wd
For the parts , , , and , please see the remarks on the following pages.
ql wd e;8q;
Battery connection (–) 4270 380
Buzzer lead terminal 4246 368
Dial washer 0491 233
Insulator for circuit block 4216 366
Connector guard 4398 371
Connector guard screw 0012 316
Connector 4313 366
Liquid crystal panel
Liquid crystal panel frame 4540 366
0012 316
• Connector guard screw (2 pcs.)
0012 168
• Switch spring screw (2 pcs.)
• Train wheel bridge screw(1 pc.)
• Coil block screw (1 pc.)
Battery (See the front page.)
Switch spring screw 0012 168
Train wheel bridge screw 0012 168
Train wheel bridge 0125 366
Intermediate center wheel and pinion (B) 0817 155
Step rotor 4146 154
Coil block screw 0012 168
Coil block (B) 4002 366
Coil lead terminal 4246 367
Center wheel and pinion
Intermediate center wheel and pinion (A) 0817 154
Hour wheel
Minute wheel and pinion 0261 380
ws
Main plate
Switch spring
Rotor stator (B) 4239 454
wf
wg
wh
wj
wk
wl
ea
es
ed
e;
ql
Circuit block 4004 139
0100 366
Page 4
PARTS CATALOGUE
Cal. H024A
4/7
Remarks
Discrimination of the hand installation height
These parts are determined by the hand installation height. Refer to the table below to choose the appropeiate part.
The caliber H024A has numerals to indicate the hand installation height, which is printed on the dial and movement.
Standard typeStandard typeHeight
Numeral for
discrimination
Printed position
Printed on
Dial
Movement
Discrimination
2
2
Hour wheel
Center wheel
and pinion
Numeral for
discrimination
2
0221 607
0271 489
Part code
ql
ql
The numeral is printed at the right end.
The numeral is printed below the caliber number.
• In a case where the numeral for discrimination is not printed on the movement (switch spring), see the numeral printed on the dial or refer to the table above to identify each part by its shape.
Switch spring (standard type)
4250 010
Liquid crystal panel
The type of liquid crystal panel differs depending on the model. Refer to "SEIKO Watch Parts Catalogue (CD­ROM)" or "Watch Parts Catalogue (SEIKO Watch Service Site)" to choose the appropriate type of the crystal panel.
Piezoelectric element 4589 006
Piezoelectric element, which is adhered to the case back, can be provided independently.
Center wheel and pinion Hour wheel
wd
e;
e;
q;
Page 5
5/7
TECHNICAL GUIDE
Cal. H024A
AC terminal
Tweezers
Switch spring
I. STRUCTURE OF THE CIRCUIT BLOCK
2. To reset the circuit of the watch with its case back closed, press the buttons “A”,”B”, “C” and “D” at the same time and hold them for 2 to 3 seconds until the display becomes blank. Then release the buttons and check that the display shows “12:00’00” AM, Sunday, January 1st” .
* Before closing the case back, apply a small quantity of
sillicon oil to the contact portion of the case back with the buzzer lead terminal (piezoelectric element).
3. Be sure to set the digital time first before setting the analogue time, as the analogue section is governed by the "second" of the digital section.
* For time/calendar setting, refer to the instruction booklet
of each caliber.
1. After the battery is replaced with a new one, or after the battery is re-installed following the repairing procedures, be sure to short-circuit the AC terminal of the circuit block and the switch spring with conductive tweezers to reset the circuit as illustrated at right.
II. REMARKS ON INSTALLING THE BATTERY
H024A
H024A
A
B
C
D
Upconverter coil
Crystal unit
AC terminal
Input terminal (–)
Buzzer output terminal
C-MOS-IC
Input terminal (+)
Coil output terminal
• The explanation here is only for the particular points of Cal. H024A.
• For the repairing, checking and measuring procedures, refer to the “TECHNICAL GUIDE, GENERAL INSTRUCTIONS.”
Page 6
6/7
TECHNICAL GUIDE
Cal. H024A
III. REMARKS ON DISASSEMBLING AND REASSEMBLING
1. Set the switch spring in position, taking care not to damage the two guide pins for the main plate. Then, tighten the two switch spring screws.
• How to install
Battery
Switch spring
2. Make sure the two hooks of the switch spring engage the main plate.
3. Insert the battery sideways, and have the hook of the switch spring’s battery clamp portion catch the main plate.
Use the universal movement holder for disassembling and reassembling.
Hour and minute hands
• Remarks on installing
After installing the battery in the movement, place the move­ment on a flat metal plate or the like to install the hands.
* Install the hour and minute hands at the 12 o’clock position
within 60 seconds after resetting the circuit.
8
6
q;
• Remarks on removing the hands
When using a tool such as a bow-shaped hand remover, exercise care so as not to damage the dial with the tool during the hand removing process. Remove the hands either in the direction of 2 o'clock and 8 o'clock or in the directions of 4 o'clock and 10 o'clock.
H024A
H024A
Guide pin
Hook
Hook
Battery clamp portion
Main plate
Switch spring screw
Page 7
7/7
TECHNICAL GUIDE
Cal. H024A
IV. VALUE CHECKING
1.3KΩ ~ 1.5KΩ
Time accuracy
To measure the accuracy, light up all the segments. To do so, press buttons “C” and “D” at the same time in the TIME/CALENDAR SETTING display. After the measurement, press any one of the button “A”, “B”, “C” or “D” to return to the TIME/ CALENDAR display.
Coil block resistance
140Ω ~ 200Ω
Upconverter coil resistance
Current consumption
For the whole movement : less than 3.76μA
For the circuit block alone : less than 1.3μA
Notes:
• Before measuring the current consumption, be sure to reset the circuit. Otherwise, current consumption cannot be measured properly.
• When the current consumption for the whole movement exceeds the standard value, measure the current consumption for the circuit block alone. If the result is within the standard value range of the current consumption for the circuit block alone, overhaul and clean the movement parts and then measure the current consumption for the whole movement again.
Copyright ©2006 by