Seiko Cal. S05A Instruction Manual

NOTES ON THE BATTERY
Do not remove the battery from the stopwatch.
If it is necessary to take out the battery, keep it out of the reach of children. If a child swallows it, consult a doctor
immediately.
Never short-circuit, heat or otherwise tamper with the battery, and never expose it to fire. The battery may burst, become very hot or catch fire.
The battery is not rechargeable. Never attempt to recharge it, as this may cause battery leakage or damage to the battery.
WARNING
NOTES ON THE STRAP
The stopwatch has a strap for wearing it around your neck. Take good care lest it should be caught by something near you or wind around your neck.
Please also note that the strap may damage your clothes, or injure your hands, neck or other parts of your body.
You are now the proud owner of a SEIKO Digital Stopwatch Cal. S05A. For best results, please read the instructions in this booklet carefully before using your SEIKO Digital Stopwatch. Please keep this manual handy for ready reference.
TO PRESERVE THE QUALITY OF YOUR STOPWATCH
WATER RESISTANCE (5 bar)
Your stopwatch is designed and manufactured to withstand up to 5 bar, such as accidental contact with splashes of water or rain. Do not operate the buttons when the stopwatch is wet or in water.
TEMPERATURES
If the stopwatch is left in direct sunlight for a long time, the display may become black, but this condition will be corrected when the stopwatch returns to normal temperature. Do not leave your stopwatch in very low temperatures below -10ºC (+14ºF) for a long time since the cold may cause:
a. a slight time loss or gain. b. the change of digits to become slow.
c. the display light to dim. However, the above conditions will be corrected when the stopwatch returns to normal temperature.
SHOCKS
Do not subject it to violent shocks.
MAGNETISM
Your stopwatch will not be affected by magnetism.
CHEMICALS
Be careful not to expose the stopwatch to solvents, mercury, cosmetic spray, detergents, adhesives or paints. Otherwise, the case, etc. may become discolored, deteriorated or damaged.
PERIODIC CHECK
It is recommended that the stopwatch be checked once every 2 to 3 years. Have your stopwatch checked by an AUTHORIZED SEIKO DEALER or SERVICE CENTER to ensure that the case, buttons, gasket and crystal seal remain intact.
PRECAUTION REGARDING CASE BACK PROTECTIVE FILM
If your stopwatch has a protective film and/or a sticker on the case back, be sure to peel them off before using it.
STATIC ELECTRICITY
The IC (Integrated Circuit) used in your stopwatch will be affected by static electricity which may disturb the display. Keep your stopwatch away from close contact with objects such as TV screens which emit strong static electricity.
LIQUID CRYSTAL PANEL
The normal life expectancy for a liquid crystal panel is approximately 7 years. After that it may decrease in contrast, becoming difficult to read. Please contact your AUTHORIZED SEIKO DEALER or SERVICE CENTER if you wish to have a new panel fitted (guaranteed one year).
FEATURES
The SEIKO Quartz Stopwatch for industrial measurement Cal. S05A is a digital decimal stopwatch that can be used for activities such as production control and performance analysis. The stopwatch features a lap time/split time memory function that can store and recall up to 100 sets of lap times and split times. Time/calendar, timer, and alarm functions are also provided.
STOPWATCH
The stopwatch can measure up to 99999.9 DM (999.999 minutes) in 1/10 DM(1/1000 minute) increments. *DM (Decimal): Unit used in a decimal system
1 DM=1/100 minute 100 DM = 1 minute 600 DM = 6 minutes 6000 DM = 60 minutes
LAP TIME, LAP TIME IN PROGRESS AND SPLIT TIME DISPLAYS
Three separate stopwatch displays are available for lap time, lap time in progress and split time measurements.
MEMORY FUNCTION
Up to 100 lap/split time data can be stored in memory, and they can be recalled either during or after the measurement.
TIME/CALENDAR
Year, month, day, date, hour, minutes and seconds are displayed. The calendar automatically adjusts for odd and even months including February of leap years from January 1, 2006 to December 31, 2055.
AUTOMATIC SHUT-OFF FUNCTION
When the stopwatch is left untouched for one hour, the display automatically becomes blank in order to minimize battery consumption.
DOUBLE REPEAT TIMER
• The built-in two descending timers (which allow you to set two different timer times) can be used repeatedly one after the other.
• Each Timer 1 and Timer 2 can be set for any desired amount of time from 10 seconds up to 99 hours, 59 minutes and 59 seconds in one-second increments.
• For easy distinction between Timer 1 and Timer 2, the time-up warning beeps are different in tones.
R
E
C
A
L
L
R
E
C
A
L
L
MEMORY
100
DECIMAL
S
T
A
R
E
T
/
S
T
O
P
L
A
P
/
S
P
L
I
T
R
E
S
E
T
INDUSTRIAL STOP WATCH
A
B
C
D
DISPLAY AND BUTTONS
SEIKO DIGITAL STOPWATCH FOR INDUSTRIAL MEASUREMENT Cal. S05A
CHANGE OF DISPLAYS
TIME/CALENDAR
display
STOPWATCH
<LAP TIME> display
STOPWATCH
<LAP TIME IN PROGRESS>display
ALARM display
STOPWATCH
<SPLIT TIME> display
TIMER display
Press Button D to change the display mode.
D
D
D
D
D
D
ALARM
• The daily alarm sounds once at the designated time (hour, minute) every 24 hours.
BATTERY LIFE INDICATOR
* If Buttons A, B, C and D are pressed at the same time, all the data in memory will be erased. Refer to “HOW TO RESET THE BUILT-IN IC” on page 13 for further details.
TIME/CALENDAR SETTING
B
A
C
“A” (AM)/
“P” (PM)
mark
Hour
Year
Month
D
Date
Day
Seconds
Minutes
Press to show the TIME/CALENDAR display.
D
B
Press and hold for 2 seconds to show the TIME/CALENDAR SETTING display.
C
A
Press repeatedly to select the digits (flashing) to be adjusted.
MINUTES
HOUR
DATE(DAY)
YEAR
12-/24-HOUR INDICATION
SECONDS
Press to set the flashing digits or reset the SECONDS to “00.”
* The DAY disappears and the SECOND digits start flashing.
* The digits move quickly if Button A is kept pressed.
12-/24-hour indication setting:
Change between 12- and 24-hour indications is made alternately with each press of Button A.
Automatic shut-off function setting (ECO) :
With each press of Button A, the automatic shut-off function(ECO) is alternately set to "ON" and "OFF."
B
After all the adjustments are completed, press to return to the TIME/CALENDAR display.
The DAY is automatically set once the YEAR, MONTH and DATE are set.
To quit the time/calendar setting, press Button B. When the stopwatch is left untouched, it automatically returns to the TIME/CALENDAR display within two to three minutes.
The calendar adjusts automatically for odd and even months including February of leap years from January 1, 2006 to December 31, 2055.
When setting the HOUR digits in the 12-hour indication, check that “A” (AM)/“P” (PM) mark is correctly set. In the 24-hour indication, no mark is displayed.
If Button A and C are pressed simultaneously, all the digital segments light up. This is not a malfunction. Press any of Button A, B, C or D to return to the TIME/ CALENDAR display.
MONTH
AUTOMATIC SHUT-OFF
(ECO)
* With each press of Button C in TIME/CALENDAR
display, the confirmation sound for button operation is alternately switched "ON" and "OFF." While the confirmation sound for button operation is set to "ON," the mark appears on display.
Confirmation sound for button operation
STOPWATCH
The stopwatch can measure up to 99999.9 DM in 1/10 DM increments.
Three separate measurement displays are available; lap time, lap time in progress and split time displays.
[LAP TIME IN PROGRESS display][LAP TIME display]
A
C
B
D
“LAP” mark Lap No.
Lap time
Accumulated
elapsed time
A
C
B
D
“RLP” mark Lap No.
Lap time
A
C
B
D
“SPL” mark Split No.
Accumulated elapsed time
Split time
Lap time
in progress
[SPLIT TIME display]
Loading...
+ 3 hidden pages