SecuTech SECU-DATA 1232 User guide

Page 1
Security & Electronic Technologies GmbH
Operating Instructions
SECU-DATA 1232
Security & Electronic Technologies GmbH
Security & Electronic Technologies GmbH
Page 2
Page 2 Security & Electronic Technologies GmbH
TOC – Table of Contents
Principle of Operation .............................................................. 3
General ................................................................................. 3
Functionality in Detail ........................................................... 3
Control Elements: ................................................................. 4
Settings .................................................................................... 5
Configuration ........................................................................ 5
Selection of RF-frequency Channel Block ............................ 7
Matching two SECU-DATA 1232 .......................................... 8
Monitoring the RF-status, Alarms ......................................... 9
Commissioning ...................................................................... 10
Installation .......................................................................... 10
Mounting the Connector Wires ........................................... 11
Terminal Connectors .......................................................... 12
Maintenance .......................................................................... 13
Warranty ................................................................................ 13
Disposal ................................................................................. 13
Technical Specification ................................ ....................... 14
Article number: LI038 Version: Rev. 1.0 Date: 2007-04
Important: The technical specification stated in this document is sub­ject to modification by the manufacturer without any notice. ©SECURITY & ELECTRONIC TECHNOLOGIES GmbH.
Page 3
Security & Electronic Technologies GmbH Page 3
RxD TxD CTS RTS GND
TxD
RxD RTS CTS GND
RxD TxD CTS RTS
GND
TxD RxD RTS CTS GND
Host device A Host device B
SECU-DATA 1232
SECU-DATA 1232
Principle of Operation
General
SECU-DATA 1232 is used for wireless data transmission of RS232 signals (point-to-point connections). The data format to both host devices can be set individually. A hardware handshake is implemented for data flow control. The incoming data are prepared for the RF-transmission, a CRC-16 check­sum value is added and then the data are sent to the remote device. In case of distortions the message is repeated automatically until it is received correctly by the partner instrument. Here the data are available in the preset format for the connected host equipment. The data transfer is bidirectional, the effective transfer rate is 2.400 Baud.
Functionality in Detail
SECU-DATA 1232 provides a receiver and a transmitter buffer with 64 bytes. RS 232 data coming in from the host device A are put into the buffer. If the buffer is full or if the preset time-out is reached (see section chapter configuration) line RTS blocks the data transfer and the data are sent via RF to the partner device which will acknowledge the reception via RF. Then the input buffer is cleared and RTS enables further data transfer. The remote SECU-DATA 1232 provides the data on the RS 232 output for the connected host device B.
Page 4
Page 4 Security & Electronic Technologies GmbH
LED
Indicators
Antenna
Cable
glands
Control Elements:
LED indicators with the following functions Green: RF connection:
OFF: no RF connection
Blinking: Searching for partner instrument, ON: RF connection active Yellow: Power supply:
OFF: power failure ON: Power supply in nominal range Red: Error indication:
OFF: system working properly ON: internal error
RF antenna: app. 150 mm (/4), TNC connector. Extension cables and an extra long antenna (/2) are available as an option.
Cable glands (M16 x 1.5)
Page 5
Security & Electronic Technologies GmbH Page 5
2
RxD
3
TxD
5
GND
7
RTS
8
CTS
3
TxD
4
RxD
7
GND
6
CTS
5
RTS
1
5
6 9
PC: 9-pole male
Button B
Button A
Settings
Configuration
The interface to the host device can be configured via the RS 232 interface using a terminal simulation software (e.g. Hyperterminal on Microsoft Win­dows® PCs). Connect the PC-interface to the SECU-DATA 1232:
PC SECU-DATA 1232
Set the terminal software settings to: 9600 Baud, 8 data bits, 1 stop bit, no parity - (8N1)
Enable “Locale Echo“, to see your inputs and also the hardware-handshake (RTS/CTS).
Open the housing of SECU-DATA 1232 and turn on the power supply con­nected to terminals1 (positive pole) and 2 (negative pole).
Press and keep depressed button “A“ and press two times shortly the but- ton “B“
Page 6
Page 6 Security & Electronic Technologies GmbH
Input
Timeout
1
24 ms
2
48 ms
3
72 ms
4
96 ms
5
120 ms
6
144 ms
7
168 ms
8
192 ms
9
216 ms
SECU-DATA 1232 is in the configuration mode now (the yellow “Power“­indicator is blinking). Independent from the preset interface parameters for normal operation SECU-DATA 1232 is communicating with 9600, 8, 1, no parity (8N1). On the terminal window you will see:
Baudrate >> 0:1200, 1:2400, 2:4800, 3:9600, 4:19200, 5:38400, 6:76800, 7:115200 ?
Enter the number for the required Baud rate (0 … 7)
Parity >> 0:NO, 1:EVEN, 2:ODD ?
Enter the appropriate number for the parity setting (0 …2)
Databits >> 0:7, 1:8 ?
Select the number of data bits (0 … 1)
Stopbits >> 0:1, 1:2 ?
Select the number of stop bits (0 … 1)
Timeout[Input * 24ms] >> 1-9 ?
Define the required time out with digits 1 … 9
Page 7
Security & Electronic Technologies GmbH Page 7
RS 232 data from
Host device
Timeout
RTS of SECU-DATA 232
Data transmission via RF
Button B
Button A
If no data are coming in from the host device A SECU-DATA 1232 will wait for the time defined herewith and afterwards it will send the data from the RS 232 input buffer via RF:
On the other hand SECU-DATA 1232 transmits the data independently from the time out as soon as the buffer of 64 bytes is full.
After the last input the settings stored in the internal flash memory and SECU-DATA 1232 is restarted (RESET). Abortion: In case of incorrect inputs press the button “B” before you have entered the last parameter. The new settings are deleted and SECU-DATA 1232 will be restarted (RESET).
Selection of RF-frequency Channel Block
SECU-DATA 1232 uses one RF-channel out of 64, these are organised in 8 blocks of 8 channels each. After delivery frequency channel block 6 is set as default. Two SECU-DATA 1232 devices can communicate only if the same frequency channel block is set on both devices.
Page 8
Page 8 Security & Electronic Technologies GmbH
Button B
Button A
Procedure for both SECU-DATA 1232:
1. Open the housing of the SECU-DATA 1232. Avoid the intrusion of moisture and pollution while the instrument is open to maintain the reliability
2. Turn on the power supply of the SECU-DATA 1232
3. Press the B-button two times shortly
4. The green “RF“-LED will blink several times, the number of light pulses gives the actual number of the channel block (1 to 8).
5. The light pulses are repeated after a 1 s pause. Each press on but­ton A increments the block number by 1. On the end of the range the block number falls back from 8 to 1 automatically.
6. An interruption of the power supply aborts the setting procedure, the original block number remains in memory; the actual one is not stored.
7. The procedure can be finished by pressing the B-button; the actual block number is stored permanently.
8. Repeat this procedure for the second SECU-DATA 1232 to set the same block number
If required you may check the block number using steps 1 to 4 as described above.
Matching two SECU-DATA 1232
After the delivery the SECU-DATA 1232 devices are not matched together. This has to be done during setup. Also after replacement of a unit, after service and repair it might be necessary to repeat the matching procedure.
Page 9
Security & Electronic Technologies GmbH Page 9
Procedure:
1. Open the housing of the SECU-DATA 1232. Avoid the intrusion of moisture and pollution while the instrument is open to maintain the long-term reliability
2. Turn on the power supply of the SECU-DATA 1232
3. Press shortly on both instruments the A-button (need not be at the same time on both devices)
4. The green “RF”-LED and the yellow “Power“-LED on the SECU- DATA 1232 start blinking alternately – the instruments are in the matching mode now
5. After completion both instruments perform automatically a RESET – the red LED flashes shortly. If the tuning process is not success­ful you can abort it by pressing shortly the button A – the original settings remain in memory
6. Now the green “RF”-LED and the yellow “Power”-LED on both de­vices are continuously on – the matching procedure is finished suc­cessfully and the RF-connection is established.
Monitoring the RF-status, Alarms
Depending on the application it might be important to monitor the status of the RF-connection and to generate an alarm indication in case of interrup­tions.
As soon as the RF-connection between two matched devices is established the green RF-LEDs go on and the power supply voltage is connected to terminal 8 of both instruments (the maximum load current is 500mA). If the RF-connection is interrupted or if there is a power failure on one of the de­vices the internal relay contact will open, terminal 8 is open then.
Page 10
Page 10 Security & Electronic Technologies GmbH
83 mm
96 mm
M4
Distance of drilling holes:
Horizontal: 83 mm Vertical: 96 mm
Commissioning
Installation
Mount the supplied RF-antenna on the connector on the housing of the SECU-DATA 1232 using the supplied adapter. Mount the SECU-DATA 1232 strain free to the base using the 4 supplied M4 screws:
In case of metallic base material (chassis of vehicles, machinery) try to maximise the distance between RF-antenna and the base to achieve max­imum effective RF range.
Page 11
Security & Electronic Technologies GmbH Page 11
Button A
Button B
Mounting the Connector Wires
SECU-DATA 1232 device contain a terminal block inside (type: WAGO se­ries 256, ATEX certified) for connecting the corresponding wires. Open the housing by removing the fixing screws on the housing lid.
Important:
Install the wiring only after the power supply of the installation has been turned off. Follow strictly the safety instructions from the manufacturer, adhere to all applicable standards, norms and technical guidelines.
Pass a round cable with the required number of wires through the cable glands (M16 x 1.5) and fix them tightly to ensure the water protection of the housing. You can use also both cable glands if necessary. If one of them is not used close it tightly with the supplied dummy cap.
Page 12
Page 12 Security & Electronic Technologies GmbH
Terminal
Signal, description
1
Plus-pole of power supply (+11 V …+40 V), protected against reversal by 2 diodes
2
Ground of power supply (0 V)
3
TxD, to be connected to RxD of the host device
4
RxD, to be connected to TxD of the host device
5
RTS, to be connected to CTS of the host device
6
CTS, to be connected to RTS of the host device
7
GND, to be connected to GND of the host device
8
Relay contact - output: Positive power supply if RF-connection is estab­lished. Open, if RF-connection is interrupted Max. load current: 500 mA
1
5
6 9
TxD RxD GND 2 3 5
CTS RTS
7 8
TxD RxD RTS CTS GND
1 2
3
4
5 6
7
8
SECU-DATA 232/1232
SECU-DATA 1232
Terminal Connectors
Wiring of a connector cable – SECU-DATA 1232:
Page 13
Security & Electronic Technologies GmbH Page 13
Maintenance
SECU-DATA 1232 does not need any maintenance, no user serviceable components are inside of the housing.
Important:
Repair and service tasks can be done by qualified service personnel only. This is the only way to maintain the required level of ignition prevention.
Warranty
For the actual services and conditions see the internet home page
www.secu-tech.at, see the GTCS – General Terms and Conditions of Sale.
Disposal
SECU-DATA 1232 must not be disposed of via the municipal waste collec­tion system. Security & Electronic Technologies GmbH. takes back used SECU-DATA 1232 devices for appropriate disposal for a small charge. The symbol for disposal via qualified recyclers is attached visibly and per­manently on the instrument.
Page 14
Page 14 Security & Electronic Technologies GmbH
Technical Specification
Power supply concept
SECU-DATA 1232 must not be used in hazardous, explosive environments. SECU-DATA 1232 is supplied from a standard DC supply in the range of +11 V … +40 V.
RF-connection
A relay contact can be used to monitor the status of the RF connection, e.g. to issue an alert in case of an RF interruption. The effective range can be up to 1 km in open areas or even more depending on the propagation con­ditions.
Radio frequency data transfer
Bidirectional RF-connection. The transmitting and the receiving frequency are in the 433 MHz band, very narrow bandwidth, 64 channels in 8 frequen­cy blocks (selectable on the instrument), 25 kHz channel separation, effec­tive range up to 1 km or even more in open areas, best temperature stability, insensitive to distortions, automatic selection of an undistorted channel, ef­fective RF data transmission rate: 2.400 Baud (data bits/s). Data loss is prevented by using a CRC16 error correction.
RF-module: Conform to ETSI EN 300 220
(1999/5/EC R&TTE directive)
Housing
Dimensions (l x w x h): 146 x 97 x 60 mm without antenna, with cable glands Weight: app. 610 g incl. antenna Antenna: 150 mm long (/4), connector type: TNC Construction: Mouldered with PU 403 – WEVO, PTB-registered Protection: IP 68 Material, colour: Deltacom ASA 4501 EC 6, dark green Technology: Plastics injection mouldering
Page 15
Security & Electronic Technologies GmbH Page 15
Rated values
Power supply voltage: 11 V ... 40 V DC Power consumption: max. 0.75 W Ambient temperature: -30°C ≤ Ta ≤ ... +75°C
RS 232 data transmission:
Standard: RS 232, V24 Lines: RxD, TxD, CTS, RTS, ground Data flow: Controlled with RTS, CTS, hardware handshake Data rate: 2.400 Baud effective
Standards, norms applied:
ETSI EN 300 220 (1999/5/EC R&TTE directive)
Order reference: SECU-DATA 1232 Order No.: HF060
One SECU-DATA 1232 instrument for wireless transmission of serial data (RS 232), 1 RF-antenna app. 150 mm (/4), 1 operating manual.
Optional accessories: SECU-TOP150: SECU-TOP300:
in case of critical RF-propagation conditions
Extension cables for the antenna incl. mounting angle for the antenna:
SECU-TOP1: SECU-TOP3: SECU-TOP6:
Spare RF-antenna, 150 mm (/4)
Antenna 300 mm (/2) for enhanced effective range,
100 cm cable 300 cm cable 600 cm cable
Order No.: HF072
Order No.: HF073
Order No.: HF069 Order No.: HF070 Order No.: HF071
Page 16
Telefon: +43 2256 20177-0 Fax: +43 2256 20177-11 E-Mail: office@secu-tech.at Homepage: www.secu-tech.at
Aumühlweg 3/1 A-2544 Leobersdorf Austria
Security & Electronic Technologies GmbH
Other products:
RF Fuelling and overfill prevention system:
LRC – Level Remote Control
Tank contents instrument LC 100
For heating oil tanks, water tanks, waste oil tanks,…
In the distribution line: Level Control Systems
Optilevel – automatic level control Industrial probes from several manufacturers TWM-Hectour – Tank Truck Management System Signalman, Ultiman, Watchman,… Visit our homepage:
Loading...