Important:
LC 300 and CleverSensor must not be installed in a hazardous environment and must not be used
for the following liquids: Gasoline, Ethanol,aggressive chemical products like acids and aggressive
chemicals.
Improper use and any resulting damages the manufacturer
cannot take any responsibility.
Modifications on the product are prohibited.
Service repair and maintenance shall be done by the manufacturer
or authorised service facilities only.
LC cannot not be used as an overfill prevention system.
The LC gives no security against the tank becoming empty.
Please, read this document carefully before the installation of LC.
Page 3
Product Description
Main advantages:
Tank contents in litres and volume percent
Ullage display (how many litres can be delivered)
Calculation of average daily demand in litres/day
Calculation of the remaining days based on average daily demand
3 different tank shapes are supported by appropriate calculations
Easy Installation
No moving components in the tank
Contactless measurement with ultra sonic pulses for optimal reliability
Temperature in °C
Applications:
heating oil tanks
waste oil tanks
water tanks
rainwater tanks
as a replacement for mechanical gauge indicators
…….
Installation Instruction
Before you make a purchase please check for possible problems at the installation,
Discuss on the phone, write, and e-mail or use the possibility of an individual meeting with our field
staff.
Use the device only in the right ambient conditions (read the specifications).
The device must not be installed in a hazardous environment (94/9/EG)
If the device is installed too near to a wall, it is possible that reflections can cause problems to the
measurement, because of the characteristic of the ultra sonic pulses are reflected off the wall.
The device should be installed in the middle of the tank, as indication you should install at least a
min. distance of 5 cm from the wall to the aperture.
The indicator should be in a position where the ultra sonic pulses can beam unhindered to the
bottom of the tank.
Built- in parts can disturb the ultrasonic pulses and may result a false measurement (e.g. pipe,
manhole, cross beam).
Check the installation situation when the tank is empty, because if the tank is full you cannot see
the built-in parts which can reflect the ultra sonic pulses.
The calculated medium value (will be calculated by the measured distance) always relates to the
level of the sensor inside of the cone (this sensor is situated at the height of the bigger external
thread).
The distance between medium level and sensor can be adjusted with the offset.
The device has a min. and max. Measurement range (look at the specifications), if you work
beyond this specifications you will get wrong or no data.
For a correct measurement you have to consider that the distance from the sensor to the maximum
filling level is not lesser as the min. measurement range.
The device must be installed perpendicular to the fluid surface, because otherwise the reflected
ultra sonic pulses can´t be received.
The sensor and the controller are not allowed to contact the medium which you want to measure.
Be sure, that your tank manufacturer allows the installation and the tank has a minimum entry of
1.5 inch, ideally
Page 4
heating oil tanks
Checking content of delivery
Please, check the contents of delivery immediately after receipt and unpacking.
In case of missing components or transport damages contact your local dealer
or our representative.
LC 300 is fitted with 2 push buttons :
A, Mode = Start up / Chance Functions
B, Arrow =
Button
Mode:
Button ▲ Set Up and
Changing values
Pre- Arrangement for Clever Sensor
1 open the unit (half turn , anti- clockwise )
2 insert batteries
Adr.: 1.Tank = Dip Switch 1 to OFF
Adr.: 2.Tank = Dip Switch 2 to OFF
Adr.: 3. Tank = Dip Switch 1 & 2 to OFF
Adr.: 4. Tank= Dip Switch 3 to OFF
Adr. :5. Tank = Dip Switch 1 & 3 to OFF
Adr. :6.Tank = Dip Switch 2 & 3 to OFF
now as many times as the address settings is programmed,
The CS is now ready to be installed on the tank.
Before you install the units to the tank it is useful to check the functionality
by a test outside the tank aerea!
All function can be made outside the tank.
Operating Server Unit LC 300 / 301
Start Up Installation
Pre- Arrangement for LC300 Server
1 Insert Batteries
1.1 LC 300 and Software Version appears
1.2 LC 300 and serialnumber appears
1.3 Insert SIM- card Caution: use only encoded SIM Cards
Pre- paid and regular Systems Cards will be accepted
Operating Clever Sensor
Red LED blinks
in function
Page 6
Server Configuration
1,
Program
Start
Inintial state
Start
Mode
Press Mode button
2
Set Up
Set Up
Mode
Set Up on display >
Release Mode
3,
Radio
Frequency
Default is 1
Mode
Fr1 = 434 MHz
FR2= 430.5 MHz
4,
date
mm/dd
Current Date
Mode
Month and day
e.g.: April 1st - 0401
5,
date
yyyy
Year
Mode
Exemple : 2009
6,
time setting
Current time
Mode
Hours and minutes
0757
= 07h 57 Minutes
7,
Instant of
time
Measurement
Time (daily)
Mode
e.g.: at 07:30 h measurement is
made by LC200
8,
GSM
Mode
GSM Mode
1 :GSM enable
0: GSM disabled
Mode
0 – GSM not active
1 –GSM activated
9,
GS sen**
SMS frequencies
Mode
0= every 28th of each month
1 = all 7 days
2 = all 14 days
3 = Daily
10, Tel.No.:
Receiver 1
Telefon Number
Recipient No.1
Mode
e.g.: 43676………
incl. country code
without zero (0) in c.c.
11, Tel.No.:
Receiver 2
Telefon Number
Recipient No.2
Mode
First digit 0,
no second recipient
GS sen** in case of current power, additional functions
4 = Measurement all 2 h. 5 = Measurement all 10 sec.
If you use 4 or 5 only alarm messages will send out.. *) after last digit appears zero 0, press arrow button ▲ until no figure appears
Hint:
New Configuration on SMS function causes SMS messages for 7 days.
Throughout that time no alarm message is sent.(only if the alarm is confirmed the second day)
Page 7
Clever Sensor Configuration
1Launch
Inintial state
Start
Mode
Press Mode button
Unto SET UP
2
SET UP
Mode
Press SET UP
PS 1 or (2,3,4..) appears
3
Sensor activtiy
Choose tank 1 to 6
Mode
Choose with arrow button.
Setting with Mode button.
4
Tank Shape
Selection
Tank Shape
1 - 3
Mode
Mode
Tank type 2:
Cylindrical, Horizontal
defined by
volume “V”
and height „H“
Mode
Tank type 3:
Cylindrical vertical,
defined by volume
“V” and height “H”
5
Tank-Volume
Enter tank volume
in litres
Mode
Type of tank is shown in
upper left corner
6
Tank-höhe
„H“
Enter tank height
in cm
Mode
Type of tank is shown in
upper left corner
7
Offset
Distance between
sensor tot he
maximum tank
level.
Mode
Distance measurement for
e.g. manhole pit or mounting
hole
8
Alarm**
(min.)
Limit for alert in
percent
Range = 1% to 39%
Mode
When Low Limit is reached
an alarm SMS will be
launched.**
9
Alarm**
(max.)
Limit for alert in
percent
Range = 60% to 99%
Mode
When high Limit is reached
an alarm SMS will be
launched **
Next step: LC 300 proceed to next Clever Sensor – up to 6 Sensors.
** 2. SMS is sending, when half of percent is reached on more!
Page 8
Operation Manual: Server & Clever Sensor
LC300 Server receives from 1 up to 6 "Clever Sensors (CS) via radio frequencies certain tank
data´s.
Tank data´s can be transmitted via GSM to 2 different telephone numbers.
Measurement:
Tank Content distance measurement with ultra sonic beam.
Temperature in C° Surrounding ( not liquid)
Regular Measurement once per day
Multiple measurement per day possible ( mains power supply) LC 301
Instant of time adjustable
LC 300 differs 3 differnt type of tank shapes:
cubic, cylindrical horicontal and cylindrical verticale.
Display Mode:
Battey Power for (Server and CS)
GSM-Signal strength
Temperature (Server und CS)
Time / Date
Average Consumption :
Average Consumption last 7 days “
Alarm Data Transmissions:
Minimal or maximal tank level
Error Code Alarm
Tank Data Transfer Adjustment:
- after start up for 7 days, or after RE- RESET for 7 days
- every 28th of each month
- all 14 days from launch time
- weekly – from launch time
- daily
Additional Function with power supply (230V)
Additionally application
Adjustment variations
GSM 0: no SMS data´s
GSM 1 mobile phone
GSM 2 USB Modem
If GSM is set to 1 or 2=ON, LC 300 will be all the time registered in the GSM network !
G, S, T or M message can be send anytime.
Data receive with certain conditions
Antenna symbol should be with 2 bars
In case of no SIM card LC 300 will not work.
Control and Alert
Setting "GSM sen." with 2 different functions
4 = measurement every 2 hours
5 = measurement every 10 seconds.
With this settings: only Alarm GSM sent out.
Caution: Setting 4 has no standard adjustment.
Under certain circumstances all 2 hours a SMS is sent.
Page 9
Current tank content measurement
Display
Operating Mode
Description
Standard display
Top line: level in percent
Bottom line: level in litres
Press Arrow>>
Launch Measuremt
Display „SEND“
wait (appr. 20sec.)
self acting
„IDLE“ Radio communication launches
Pls. wait (appr. 30 sec.)
self acting
usw…
All Tanks in use on display
1,2,3,
Display
Operating Mode
Description
Default Application:
Percents
Tank content in litres
Continue with Mode
Tank content in Litres
Continue with Mode
Tank content in Percent
Continue with Mode
Ullage in Litres
Continue with Mode
Disance from Sensor to liquid surface in cm
Continue with Mode
Average consumption per day in Litres.
Continue with Mode
Storage in days (calculate from average consumption)
Continue with Mode
Temperatur in °CAmbient Temperatur
z.B.: 22°C
Continue with Mode
Full wird angezeigt falls der Abstand weniger als 20 cm beträgt
Tank voll“
Standard Display (battery usage)
Press the Mode button in the sleeping mode.
Last measurement indication of all clever sensors will frequently indicate on server display.
In battery mode LC 300 Server will shut off after 45 sec. (sleeping mode)
Page 10
Single Tank Results
Tank
data´s
Litres
Percent
Ullage
Distance
Cm
Average
Reserve
Temp
Error
continue
Tank 4
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
Error
Server
Start
Anzeige
Server
Fehler
Error
Code
Sensor
Fehler
Error Codes Server
0 = OK
2 = problem with SMS recipient 1
3 = problem with SMS recipient 2
4 = RF not working
5 = battery low (below 8%)
Error Codes Clever Sensor
0 = OK
1 = not available
1 = ultrasonic measurement problem
2 = ultrasonic measurement out of setting
3 = RF not responding
4 = battery low (below 8%)
Error Codes (if the displayed Error-Code is not in the list below LC has a combination of Errors.
After all tanks has been displayed- return to start
Default Error Codes
LC 300 Remote Data Transmission <RDT>
In Current Power (and under certain qualifications even with battery power)
LC 300 can be programmed via GSM.
Use mobile phone or use PC via LC DC program with USB telephone SIM Card.
Automatic data transfer to stored telephone numbers
For power supply unit: Tank data´s can be sent or stored data´s can be modified.
M = Instant Measurement
M-message = remote request for measurement
Send out: M to SIM Card number in LC 300
(LC 300 accomplish measurement and
send back all actual tank data´s)
T-SMS (Recipient Phone Number Setting)
Send Out: T,33123456789,49123456789, (without gaps)
1 2 3
1 Telephone 2 Phone number first recipient +33123456789
3 Phone number second recipient +49123456789
Warning : x-substitution not working !
Please follow this rules for LC 300
For Exemple : Message & Telephone settings
T+0, +0, (both numbers will not work)
Never use 0 as first digit !!
T+41793031234, (first number is correct used).
+0049…, (second number is invalid).
General Additional Information
Alert Application:
Minimum Alarm: 0 = no Alarms / Alarm Range 1% to 39%
Maximum Alarm: 100= no Alarms/ Alarm Range 99% to 60%
GSM Signal Strength
30 to 21 perfect, 20 to 7 good, 6 to 1 bad .
Sleeping Mode:
If no button is pressed, after 45 sec. the LC 300 ( battery used) return to sleeping mode.
Setting Telephone numbers:
LC 300 / 301 SW Version 02.54 and below will work only with country code. 436765509149
Due to the fact that there are different lengths of phone numbers it can happen that at the end of
the entered number still a zero is flashing. In that case press the "Arrow button" till this digit is blank.
Confirm with the regular "Mode button"
Page 13
Reset:
Press simultaneous Mode & Arrow button.
Keep both buttons pressed,
Release Arrow button and press Arrow button again.
Measurement start automatically.
All statistical data will be deleted: e.g. remaining days, consumption
All manual installed data will remain.
Re- launch 7 days control measurement & SMS function
Press simultaneous Mode & Arrow button.
RE-Reset:
Removing Batteries
Maintenance & Service
The LC 300 doesn’t need any maintenance. Only the batteries should be checked once a year to
avoid spilling of aggressive fluids into the device.
Important: If you notice any damage on the housing or control elements during the operation
dismount the device immediately and send it back to an authorized service facility. Close the tank
inlet again to avoid pollution.
If the LC 300 shows an unexpected behavior, please reset the LC 300 (see also 2)
If the problem persists send the LC 300 to an authorized service facility.
Warranty
For our warranty conditions see our home page www.secu-tech.at
Read also the General Terms and Conditions.
Technical specifications LC300 Server Clever Sensor
UltraSonic level measurement 19 to 270 cm
Beam angle : less than 20 degrees
Measurement precision (calibrated at 20 degrees Celsius) : -+ 1 cm
Power supply :each unit 4 pcs. 1,5V, Baby, Type C , Alkali
Consumption measurement : NA 22 mA
normal mode : 12 mA 12 mA
sleeping mode "non PS" : 0,43 mA NA
sleeping mode "PS" : 0,12 m 0,07 mA
Battery life time ~ 3 years 4 years
(depends of other settings and the GSM Network)
GSM 2 band NA
RF434 Mhz & 430.5 RF434 Mhz & 430.5
RF range :free distance = 120m
through two armed concrete walls = 15m
Dimensions : 131x86x64 mm 1 80x85 mm
Threads 1 ½” and 2”
Weight incl. Batteries: 620 g 550 g
LCD Display : 1 x 6 & 1 x 5 digits NA
Protection:IP 65IP 65
Material : ABS black ABS black
transparent
Temperature : - 20°C ... +45°C
- 10°C ... +45°C
Norm : CE / ROHS CE / ROHS
Power Supply LC 301 230 V/ 6V
Security & Electronic Technology, Aumühlweg 3/1, A-2544 Leoberdorf - Austria