SecuTech LC300 User guide

Page 1
Manual
Tank Gauge for 1 up to 6 Tanks
Radio Transmission from Tank to server
+ GSM Data Transmission to 2 recepiants
Clever Sensor SW 01.49
Server SW 00.74
03 2012 LC 3 D M 01_C
Page 2
Table of Contents
Safety Instructions ........................................................................................................................... 2
Product Description ......................................................................................................................... 3
Installation Instruction ...................................................................................................................... 3
Checking content of delivery............................................................................................................ 4
Operating Server Unit LC 300 / 301 ............................................................................................... 5
Start Up Installation ......................................................................................................................... 5
Operating Clever Sensor ................................................................................................................ 5
Server Configuration ....................................................................................................................... 6
New Configuration on SMS function causes SMS messages for 7 days. ......................................... 6
Clever Sensor Configuration ........................................................................................................... 7
Operation Manual: Server & Clever Sensor ..................................................................................... 8
Additional Function with power supply (230V) ................................................................................. 8
Current tank content measurement ................................................................................................. 9
Single Tank Results ...................................................................................................................... 10
Default Error Codes ............................................................................................................ 10
LC 300 Remote Data Transmission <RDT> ................................................................................... 10
LC 301Power Supplied Remote Data Transmission <RDT> .......................................................... 11
Reset: ........................................................................................................................................... 13
RE-Reset: ..................................................................................................................................... 13
Removing Batteries ....................................................................................................................... 13
Maintenance & Service.................................................................................................................. 13
Warranty ....................................................................................................................................... 13
Technical specifications LC300 Server Clever Sensor .................................. 13
Remark: This technical specifications can be changed anytime from :
© SECURITY & ELECTRONIC TECHNOLOGIES GmbH Adress: Aumühlweg 3/1 Town: A-2544 Leobersdorf Country. Austria Telefon: +43 2256 201 77 0 Fax: +43 2256 201 77 11
Internet: www.secu-tech.at E-Mail: office@secu-tech.at
Safety Instructions
Important: LC 300 and CleverSensor must not be installed in a hazardous environment and must not be used for the following liquids: Gasoline, Ethanol,aggressive chemical products like acids and aggressive chemicals. Improper use and any resulting damages the manufacturer cannot take any responsibility. Modifications on the product are prohibited. Service repair and maintenance shall be done by the manufacturer or authorised service facilities only. LC cannot not be used as an overfill prevention system. The LC gives no security against the tank becoming empty. Please, read this document carefully before the installation of LC.
Page 3
Product Description
Main advantages:
Tank contents in litres and volume percent  Ullage display (how many litres can be delivered)  Calculation of average daily demand in litres/day  Calculation of the remaining days based on average daily demand  3 different tank shapes are supported by appropriate calculations  Easy Installation  No moving components in the tank  Contactless measurement with ultra sonic pulses for optimal reliability  Temperature in °C
Applications:
heating oil tanks  waste oil tanks  water tanks  rainwater tanks  as a replacement for mechanical gauge indicators  …….
Installation Instruction
Before you make a purchase please check for possible problems at the installation, Discuss on the phone, write, and e-mail or use the possibility of an individual meeting with our field staff. Use the device only in the right ambient conditions (read the specifications). The device must not be installed in a hazardous environment (94/9/EG) If the device is installed too near to a wall, it is possible that reflections can cause problems to the measurement, because of the characteristic of the ultra sonic pulses are reflected off the wall. The device should be installed in the middle of the tank, as indication you should install at least a min. distance of 5 cm from the wall to the aperture. The indicator should be in a position where the ultra sonic pulses can beam unhindered to the bottom of the tank. Built- in parts can disturb the ultrasonic pulses and may result a false measurement (e.g. pipe, manhole, cross beam). Check the installation situation when the tank is empty, because if the tank is full you cannot see the built-in parts which can reflect the ultra sonic pulses. The calculated medium value (will be calculated by the measured distance) always relates to the level of the sensor inside of the cone (this sensor is situated at the height of the bigger external thread). The distance between medium level and sensor can be adjusted with the offset. The device has a min. and max. Measurement range (look at the specifications), if you work beyond this specifications you will get wrong or no data. For a correct measurement you have to consider that the distance from the sensor to the maximum filling level is not lesser as the min. measurement range. The device must be installed perpendicular to the fluid surface, because otherwise the reflected ultra sonic pulses can´t be received. The sensor and the controller are not allowed to contact the medium which you want to measure. Be sure, that your tank manufacturer allows the installation and the tank has a minimum entry of
1.5 inch, ideally
Page 4
heating oil tanks
Checking content of delivery
Please, check the contents of delivery immediately after receipt and unpacking. In case of missing components or transport damages contact your local dealer or our representative.
LC 300 / LC 301, , Clever Sensors, 1-6 Pcs. CleverSensor
Page 5
LC 300 is fitted with 2 push buttons : A, Mode = Start up / Chance Functions B, Arrow =
Button Mode:
Button Set Up and Changing values
Pre- Arrangement for Clever Sensor
1 open the unit (half turn , anti- clockwise ) 2 insert batteries
Adr.: 1.Tank = Dip Switch 1 to OFF Adr.: 2.Tank = Dip Switch 2 to OFF Adr.: 3. Tank = Dip Switch 1 & 2 to OFF Adr.: 4. Tank= Dip Switch 3 to OFF Adr. :5. Tank = Dip Switch 1 & 3 to OFF Adr. :6.Tank = Dip Switch 2 & 3 to OFF
now as many times as the address settings is programmed, The CS is now ready to be installed on the tank. Before you install the units to the tank it is useful to check the functionality
by a test outside the tank aerea! All function can be made outside the tank.
Operating Server Unit LC 300 / 301
Start Up Installation
Pre- Arrangement for LC300 Server
1 Insert Batteries
1.1 LC 300 and Software Version appears
1.2 LC 300 and serialnumber appears
1.3 Insert SIM- card Caution: use only encoded SIM Cards
Pre- paid and regular Systems Cards will be accepted
Operating Clever Sensor
Red LED blinks in function
Page 6
Server Configuration
1, Program
Start
Inintial state Start
Mode
Press Mode button
2 Set Up
Set Up
Mode
Set Up on display >
Release Mode
3, Radio
Frequency
Default is 1
Mode
Fr1 = 434 MHz FR2= 430.5 MHz
4, date mm/dd
Current Date
Mode
Month and day
e.g.: April 1st - 0401
5, date yyyy
Year
Mode
Exemple : 2009
6, time setting
Current time
Mode
Hours and minutes 0757 = 07h 57 Minutes
7,
Instant of
time
Measurement Time (daily)
Mode
e.g.: at 07:30 h measurement is made by LC200
8,
GSM
Mode
GSM Mode
1 :GSM enable 0: GSM disabled
Mode
0 – GSM not active 1 –GSM activated
9,
GS sen**
SMS frequencies
Mode
0= every 28th of each month
1 = all 7 days 2 = all 14 days 3 = Daily
10, Tel.No.:
Receiver 1
Telefon Number Recipient No.1
Mode
e.g.: 43676………
incl. country code
without zero (0) in c.c.
11, Tel.No.:
Receiver 2
Telefon Number Recipient No.2
Mode
First digit 0, no second recipient
GS sen** in case of current power, additional functions 4 = Measurement all 2 h. 5 = Measurement all 10 sec.
If you use 4 or 5 only alarm messages will send out.. *) after last digit appears zero 0, press arrow button until no figure appears
Hint:
New Configuration on SMS function causes SMS messages for 7 days.
Throughout that time no alarm message is sent.(only if the alarm is confirmed the second day)
Page 7
Clever Sensor Configuration
1Launch
Inintial state
Start
Mode
Press Mode button
Unto SET UP
2
SET UP
Mode
Press SET UP PS 1 or (2,3,4..) appears
3
Sensor activtiy
Choose tank 1 to 6
Mode
Choose with arrow button. Setting with Mode button.
4
Tank Shape
Selection
Tank Shape
1 - 3
Mode
Mode
Tank type 2:
Cylindrical, Horizontal
defined by
volume “V”
and height „H“
Mode
Tank type 3:
Cylindrical vertical,
defined by volume
“V” and height “H”
5
Tank-Volume
Enter tank volume
in litres
Mode
Type of tank is shown in upper left corner
6
Tank-höhe
„H“
Enter tank height
in cm
Mode
Type of tank is shown in upper left corner
7
Offset
Distance between
sensor tot he
maximum tank
level.
Mode
Distance measurement for e.g. manhole pit or mounting hole
8
Alarm**
(min.)
Limit for alert in
percent
Range = 1% to 39%
Mode
When Low Limit is reached an alarm SMS will be launched.**
9
Alarm**
(max.)
Limit for alert in
percent
Range = 60% to 99%
Mode
When high Limit is reached an alarm SMS will be launched **
Next step: LC 300 proceed to next Clever Sensor – up to 6 Sensors.
** 2. SMS is sending, when half of percent is reached on more!
Page 8
Operation Manual: Server & Clever Sensor
LC300 Server receives from 1 up to 6 "Clever Sensors (CS) via radio frequencies certain tank data´s. Tank data´s can be transmitted via GSM to 2 different telephone numbers. Measurement:
Tank Content distance measurement with ultra sonic beam.  Temperature in C° Surrounding ( not liquid)  Regular Measurement once per day  Multiple measurement per day possible ( mains power supply) LC 301  Instant of time adjustable
LC 300 differs 3 differnt type of tank shapes: cubic, cylindrical horicontal and cylindrical verticale. Display Mode:
Battey Power for (Server and CS) GSM-Signal strength Temperature (Server und CS)
Time / Date Average Consumption : Average Consumption last 7 days Alarm Data Transmissions: Minimal or maximal tank level Error Code Alarm Tank Data Transfer Adjustment:
- after start up for 7 days, or after RE- RESET for 7 days
- every 28th of each month
- all 14 days from launch time
- weekly – from launch time
- daily
Additional Function with power supply (230V)
Additionally application Adjustment variations GSM 0: no SMS data´s GSM 1 mobile phone GSM 2 USB Modem If GSM is set to 1 or 2=ON, LC 300 will be all the time registered in the GSM network ! G, S, T or M message can be send anytime.
Data receive with certain conditions
Antenna symbol should be with 2 bars  In case of no SIM card LC 300 will not work.
Control and Alert Setting "GSM sen." with 2 different functions 4 = measurement every 2 hours 5 = measurement every 10 seconds. With this settings: only Alarm GSM sent out. Caution: Setting 4 has no standard adjustment. Under certain circumstances all 2 hours a SMS is sent.
Page 9
Current tank content measurement
Display
Operating Mode
Description
Standard display Top line: level in percent
Bottom line: level in litres
Press Arrow>> Launch Measuremt
Display „SEND“ wait (appr. 20sec.)
self acting
„IDLE“ Radio communication launches
Pls. wait (appr. 30 sec.)
self acting usw…
All Tanks in use on display 1,2,3,
Display
Operating Mode
Description
Default Application: Percents Tank content in litres
Continue with Mode
Tank content in Litres
Continue with Mode
Tank content in Percent Continue with Mode
Ullage in Litres
Continue with Mode
Disance from Sensor to liquid surface in cm
Continue with Mode
Average consumption per day in Litres.
Continue with Mode
Storage in days (calculate from average consumption)
Continue with Mode
Temperatur in °CAmbient Temperatur z.B.: 22°C
Continue with Mode
Full wird angezeigt falls der Abstand weniger als 20 cm beträgt Tank voll“
Standard Display (battery usage) Press the Mode button in the sleeping mode.
Last measurement indication of all clever sensors will frequently indicate on server display.
In battery mode LC 300 Server will shut off after 45 sec. (sleeping mode)
Page 10
Single Tank Results
Tank data´s
Litres
Percent
Ullage
Distance
Cm
Average
Reserve
Temp
Error
continue
Tank 4
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
continue
Mode>
Error
Server
Start
Anzeige
Server Fehler
Error
Code
Sensor
Fehler
Error Codes Server
0 = OK 2 = problem with SMS recipient 1 3 = problem with SMS recipient 2 4 = RF not working 5 = battery low (below 8%)
Error Codes Clever Sensor 0 = OK
1 = not available 1 = ultrasonic measurement problem 2 = ultrasonic measurement out of setting 3 = RF not responding 4 = battery low (below 8%)
Error Codes (if the displayed Error-Code is not in the list below LC has a combination of Errors.
After all tanks has been displayed- return to start
Default Error Codes
LC 300 Remote Data Transmission <RDT>
In Current Power (and under certain qualifications even with battery power) LC 300 can be programmed via GSM. Use mobile phone or use PC via LC DC program with USB telephone SIM Card.
Automatic data transfer to stored telephone numbers
Control SMS "t = 1-3" LC300<t>,<swVS>,<swVC,<ddmmyy>,<deviceNr>,SMSseqNr> <Server=0> 000 00000 000 <GSMstrength> <Battery%> <Temp> <ErrorAl> <CSnr> <%> <Volume> <averageCons> <Distance> <Battery%> <Temp> <ErrorAl> Alarm / Error SMS message "t = 4" LC300<t>,<swVS>,<swVC,<ddmmyy>,<deviceNr>,SMSseqNr> <ServerOrCSnr> <LevelAlType%%> <ErrorCode>
Page 11
LC 301Power Supplied Remote Data Transmission <RDT>
LC300,1,0117,218,170310,01256,00000
0 000 00000 000 019 084 +21 0N
5 052 00500 010 100 100 +23 0N 6 085 01900 210 023 025 +15 0H
S-Answer SMS
LC300,0117,218,170310,01256,00000, 00 1625 1605 1 +33123456789 +49123456789 LC300,5=S Answer, ServerSW=01.17,CSsw=,messageID=00
000 HandyMode,PS=ON, actualTime=16:25, measureTime=16:05, periodicy=weekly,
1.phone=France,
2.phone=Germany
C-Answer SMS
LC300,6,0117,218,170310,01256,00000
3,1,1,2000,120,10,25,82
LC300, 6=SAnswer, ServerSW=01.17, CSsw2.18, ServerID=1256, messageID00000
CS addr.=3,CS=enable, Tankshae=rectang., VL=2000,heightcm=120 ,Offset=10, LowLevelAl=25%, HighLevelAl=85%
For power supply unit: Tank data´s can be sent or stored data´s can be modified.
M = Instant Measurement M-message = remote request for measurement Send out: M to SIM Card number in LC 300 (LC 300 accomplish measurement and send back all actual tank data´s)
S = S-SMS (Server Settings) Send out : S1, 0, 1231, 2009, 1625,1605, 1, 33123456789,49123456789, (without gaps) 1 2 3 4 5 6 7 8 9
1 GSM / Handy- or DataCenter-Mode :
1 = Handy
2 = DataCenter-Mode
2 RF (make a Reset to activate)
3 Date & time 31.12 4 2009, 5 16:25 6 Measurement time 16:05h 7 Period of the control SMS 1 = weekly
0 = monthly 2 = two weekly 3 = daily
8 Phone number for France +33123456789 9 Phone number in Germany +49123456789
C-SMS : for Clever Sensor Settings Send Out:
C3, 1, 1, 2000, 120, 10, 25, 82, (without gaps)
1 2 3 4 5 6 7 8 1Address Clever Sensor3
2CleverSensor 1 = enable / 0 = disable 3Tank shape 1 = rectangular
4Tank Volume in litres 2000 5 Tank height /diameter 120 6Offset 10 7 Low level Alarm in % 25 8High level Alarm in % 82
0 = GSM OFF (not accepted)
0 = 434 MHz 1 = 430.5 MHz
2= cylindrical horizontal / 3 = cylindrical vertical
Page 12
T-Answer SMS LC300,7,0117,218,01256,00000
+33123456789, +49123456789 LC300, 7=T-Answer, ServerSW=01.17, CSsw=2.18, ServerID=1256, messageID=00000 PhoneNumberRecipient1, PhoneNumberRecipient2
T-SMS (Recipient Phone Number Setting) Send Out: T,33123456789,49123456789, (without gaps)
1 2 3
1 Telephone 2 Phone number first recipient +33123456789
3 Phone number second recipient +49123456789
Warning : x-substitution not working !
Please follow this rules for LC 300 For Exemple : Message & Telephone settings
T+0, +0, (both numbers will not work) Never use 0 as first digit !! T+41793031234, (first number is correct used).
+0049…, (second number is invalid).
General Additional Information
Alert Application: Minimum Alarm: 0 = no Alarms / Alarm Range 1% to 39% Maximum Alarm: 100= no Alarms/ Alarm Range 99% to 60%
GSM Signal Strength 30 to 21 perfect, 20 to 7 good, 6 to 1 bad .
Sleeping Mode: If no button is pressed, after 45 sec. the LC 300 ( battery used) return to sleeping mode.
Setting Telephone numbers: LC 300 / 301 SW Version 02.54 and below will work only with country code. 436765509149
Due to the fact that there are different lengths of phone numbers it can happen that at the end of the entered number still a zero is flashing. In that case press the "Arrow button" till this digit is blank. Confirm with the regular "Mode button"
Page 13
Reset:
Press simultaneous Mode & Arrow button. Keep both buttons pressed, Release Arrow button and press Arrow button again. Measurement start automatically. All statistical data will be deleted: e.g. remaining days, consumption All manual installed data will remain. Re- launch 7 days control measurement & SMS function
Press simultaneous Mode & Arrow button.
RE-Reset:
Removing Batteries
Maintenance & Service
The LC 300 doesn’t need any maintenance. Only the batteries should be checked once a year to avoid spilling of aggressive fluids into the device. Important: If you notice any damage on the housing or control elements during the operation dismount the device immediately and send it back to an authorized service facility. Close the tank inlet again to avoid pollution. If the LC 300 shows an unexpected behavior, please reset the LC 300 (see also 2) If the problem persists send the LC 300 to an authorized service facility.
Warranty
For our warranty conditions see our home page www.secu-tech.at Read also the General Terms and Conditions.
Technical specifications LC300 Server Clever Sensor
UltraSonic level measurement 19 to 270 cm Beam angle : less than 20 degrees Measurement precision (calibrated at 20 degrees Celsius) : -+ 1 cm Power supply :each unit 4 pcs. 1,5V, Baby, Type C , Alkali Consumption measurement : NA 22 mA normal mode : 12 mA 12 mA sleeping mode "non PS" : 0,43 mA NA sleeping mode "PS" : 0,12 m 0,07 mA Battery life time ~ 3 years 4 years
(depends of other settings and the GSM Network) GSM 2 band NA RF434 Mhz & 430.5 RF434 Mhz & 430.5 RF range : free distance = 120m
through two armed concrete walls = 15m
Dimensions : 131x86x64 mm 1 80x85 mm Threads 1 ½” and 2” Weight incl. Batteries: 620 g 550 g LCD Display : 1 x 6 & 1 x 5 digits NA Protection:IP 65IP 65 Material : ABS black ABS black transparent Temperature : - 20°C ... +45°C
- 10°C ... +45°C Norm : CE / ROHS CE / ROHS Power Supply LC 301 230 V/ 6V
Security & Electronic Technology, Aumühlweg 3/1, A-2544 Leoberdorf - Austria