Securitron PDB-4F1, PDB-4F2, PDB-4C1, PDB-4C2, PDB-8F1 Installation Instructions

...
PDB-4F/C & PDB-8F/C
Power Distribution Boards
Certifications
Devices

This Manual applies to models: PDB-4F1, PDB-4F2, PDB-4C1, PDB-4C2, PDB-8F1, PDB-8F2, PDB-8C1, PDB-8C2

Features:

denoted models. Class 1 wiring is required for “F” denoted models
9-28 VDC Operation
Reverse polarity protected
Available with glass fuses or PTC protection
Output LED’s indicate condition
Form C Contacts Indicates Trigger Status
MagnaCare Lifetime Warranty
UL Listed Sub Assembly for Access Control and Burglar Alarm
Systems
Description:
Converts a singl e 9-28VDC Input to 4 or 8 protected class 2 rated
output for PTC protected models.
Main Power Green/Red LED Indicates AC, DC or Reversed DC
Input on PDB-8
Each output has a green status LED indictor
Current Draw is 6ma max per LED
Main Fuse / Power Pull is standard ATO Automotive size on PDB-8
Rated 20A
Unit shall be installed in accordance with the National Electrical
Code, ANSI/NFPA 70; Canadian Electrical Code, or any other applicable codes.
PDB-4F, PDB-4C, PDB-8F, & PDB-8C are UL listed Sub Assemblies
As configured in UL listed products suitable for Access Control and Burglar alarm systems
All Input Terminal blocks and output terminal blocks on the PDB-
8F, 8C module are rated 25A with a wire range of 10 – 18AWG
Output Terminal blocks on the PDB-4F,4C are rated 10A with
wire range 12-22AWG
Note: Proper wire size should be selected based on output load
Size: PDB 4F 3.75”H x 2.22”W x 1”D Mounting: 3.41”H x
1.87”W
Size: PDB-8F 3.87”H x 4.84”W x 1”D Mounting: 3.41”H x
4.49”W
Main Fuse Ratings 10A, 32V for 1A models/ 20A, 32V for 2A
models
Caution: for continued protection against risk of fire,
replace only with fuse of the same type and having the same electrical ratings.
Note: All distribution boards shall be powered by either a
UL 294 or 603 or ULC S318 or ULC S533 power supply with a class 2 output or Class 1 wiring must be employed.
PDB-8F2 / PDB-8C2 Ratings:
o Input 9-28VDC (Nominal 12-24VDC) o Current draw of PCB 55mA o Rated output: 8.4-28VDC, 2 Amps max per port,
16 Amps total combined Load all outputs
o Littelfuse part number 0312002.MXP Rated
2A,250V
PDB-8F1 / PDB-8C1 Ratings:
o 9-28VDC (Nominal 12-24VDC) o Current draw of PCB 55mA o Rated output: 8.4-28VDC, 1 Amps max per port,
8 Amps total combined Load all outputs
o Littelfuse part number 0312002.MXP Rated
2A,250V
PDB-4F2 / PDB-4C2 Ratings:
o 9-28VDC (Nominal 12-24VDC) o Current draw of PCB 24mA o Rated output: 8.7-28VDC, 2 Amps max per port
8 Amps total combined Load all outputs
PDB-4F1 / PDB-4C1 Ratings:
o 9-28VDC (Nominal 12-24VDC) o Current draw of PCB 24mA o Rated output: 8.7-28VDC, 1 Amps max per port
4 Amps total combined Load all outputs.
UL 294 Access Control System Unit
o Line Security Level I o Endurance Test Level IV o Standby Power Level I o Attack Test Level I
UL 603 Power Supplies for Use with Burglar-Alarm Systems ULC S318 Power supplies for Burglar Alarm Systems ULC S533 Standard for Egress Door Securing and Releasing
500-33065_2