Securitron MXD-62, MXD-32 Installation And Operating Instructions Manual

PN# 500-12800 Page 1 Rev. A.2, 6/00
SECURITRON MODEL MXD-32, MXD-62 DOOR MOVEMENT EXIT DELAY
INSTALLATION AND OPERATING INSTRUCTIONS
1. DESCRIPTION
The MXD consists of several components which, when combined with a Magnalock, will produce an initiate signal for delayed exit as controlled by Securitron’s XDT logic timer when a person pushes on the door and moves it a modest distance.
The specific components within the MXD “kit” are: A mounting sub-plate which affixes the magnet body to the door frame or header. A sealed proximity switch array which is also mounted on the sub-plate. This changes state
to provide the initiate signal. A stamped, stainless steel housing which covers the magnet body and proximity switch array. A sealed permanent magnet affixed to a bracket that mounts behind the strike plate. As this
unit moves away from the proximity array, the array switches. A special sex bolt with internal spring that permits the door to move away from the strike
plate (the strike plate remains secured to the magnet body) so as to create the initiate signal when a person pushes on the door opening it up to one inch.
Copyright, 2000, all rights reserved Securitron Magnalock Corp., 550 Vista Blvd., Sparks NV 89434, USA
Tel: (775) 355-5625 (800) MAGLOCK Fax: (775) 355-5636 Website: www.securitron.com
An ASSA ABLOY Group company
Rev. A.2, 6/00 Page- 2
Use of the MXD permits delayed exit without the need to alter the existing door latch and hardware. The relatively large door movement that it supports (up to one inch) eliminates the potential problem of false triggering if the door is rattled or subjected to wind loads. It is also highly tamper resistant in the event that someone would wish to defeat its safety function of allowing people to exit.
2. PHYSICAL INSTALLATION
2.1 DETERMINING HORIZONTAL OR VERTICAL MOUNT AND APPLYING TEMPLATE
The MXD can be mounted horizontally under the frame header or vertically along the frame. Once you have selected the orientation for your installation, apply the template to set your hole drilling positions. To apply the template, close the door (be sure it latches) and note that the template has a folding line on it. The magnet mounting “sub-plate” is on one side of the line and the strike plate/permanent magnet bracket is on the other. Position the fold in the template along the edge the door stop makes with the door surface so that the sub-plate portion of the template extends on to the door stop and the strike/permanent magnet bracket portion extends on to the door surface. If you have a swing through type aluminum frame glass door, there is no door stop so you simply position the template fold line on the edge between the door surface and frame stile. In planning your installation for this type of door, a special consideration comes into play. First, before drilling any holes, you want to be sure that the aluminum door rail is wide enough to support the sex bolt. The MXD sex bolt is 1” (25MM) diameter which is much thicker than normal magnetic lock sex bolts. This type of door is made with extrusion widths which vary widely but some are so narrow that you can only mount the MXD sex bolt when you are using the model 32 lock. Some others will accept a model 62 lock but only when you are using the offset strike.
To determine in advance whether your door and the Magnalock that you intend to use will accept the MXD sex bolt, just hold the template so that you can visually see the center point of where the sex bolt will go into the door rail. Assure yourself that a 1” diameter hole around this point will not strike the glass or any support rods internally.
Note: if you have an aluminum frame glass door with a blade stop, see the next section as the template is used differently. Otherwise, the template will work on horizontal or vertical mounts and on left hand or right hand doors but be sure that the edge of the template is flush to the corner of the door stop for best mounted appearance (the MXD housing will reach to the corner of the door stop).
Tape the template into position and using a center punch, mark the hole locations on the door and frame. The template will indicate the number and positions of the hole locations as well as the hole diameters. This depends on which Magnalock type is being used. Note that if the door stop is narrow, you may need to add a filler plate to create a wide enough mounting surface for the sub-plate.
2.2 TEMPLATE USE ON AN ALUMINUM FRAME GLASS DOOR WITH BLADE STOP
A blade stop is so narrow (around 1/8”) that nothing can be mounted on it. Therefore, you cannot place the folded edge of the template in the corner made by the stop and door surface as you will not be mounting on the stop. You will be mounting the sub-plate adjacent to the stop directly on the frame extrusion. To use the template in this exceptional situation, cut it with a scissors along the fold line. To mark the strike plate/permanent magnet bracket holes, open the door slightly and insert the template behind the blade stop until it just touches the door frame. Then allow the door to fully close (this will capture the template). You can then
Rev. A.2, 6/00 Page- 3
accurately punch your mounting holes for the strike plate/permanent magnet bracket just as if the blade stop was not present.
To mark the holes for the sub-plate, you will use the other half of the template. Normally, you would position its fold line edge to rest against the door surface but the blade stop is in the way. Simply measure the distance from the door surface to the surface of the blade stop and “subtract” that distance from the template half by either cutting the template or re-folding it. The distance is usually around 3/8” (9.5MM) but it will vary from door to door depending on the thickness of the blade stop and the spatial point at which the door is closed.
An alternate method for mounting the sub-plate dispenses with the template half and uses the sub-plate as its own template. To employ this method, close the door and measure back from the surface of the door past the blade stop 5/8” (16MM) for a model 32 Lock or 9/16” (14MM) for a model 62 Lock. The best way to do this is to make two measurements and mark two points each of which is the correct distance away from the surface of the door. Then a line can be drawn between the two points. The sub-plate may be used as a straight edge for drawing this line.
Align the front edge of the sub-plate to this line and you have achieved the correct backset. To set the lateral position of the sub-plate, move it away from the frame corner about 1/8” (3MM). This will allow the housing cover to fit over it and still produce an attractive mount that appears to reach to the frame corner. Then mark and drill the mounting holes for the sub-plate.
2.3 IF THE DOOR IS THINNER OR THICKER THAN STANDARD
The MXD sex bolt is dimensioned to precisely fit a 1 3/4” (44.5 MM) thick door which is a common size. If the door is a different thickness, contact the factory. Securitron can supply washers for a thinner door, which go under the head and key in to the anti-rotation pins while including new anti-rotation pins. For a thicker door, the bolt may be partially unscrewed to expand it for use with up to a 2” thick (51MM) door. If you do this, be sure to install Threadlock on the threads (Threadlock is furnished in a capsule with the MXD). When the bolt is “expanded” to suit a thicker door however, its ability to allow to door to move for delay initiation is proportionately reduced. The factory, however, can supply spacers to adapt the bolt to thicker doors while retaining full door movement distance.
2.4 MOUNTING THE PERMANENT MAGNET BRACKET, MXD SEX BOLT AND STRIKE
Note the assembly drawing in Figure 1. The first step after all the holes are drilled from the template is to install the permanent magnet bracket. The model 62 version comes with four self tapping screws to hold the bracket to the door and the model 32 version comes with two. Note that this bracket is not handed. It can be flipped to place the permanent magnet (concealed in an aluminum block) either to the right or the left to line up with the proximity switch array on the sub-plate. The proximity switch array can also be transferred to either side of the sub-plate (the holes are drilled for either position). The reason for this flexibility is to maximize wiring options. In the case of a concrete filled header, for example, the cable can not usually be pulled up into the header. A flex conduit fitting can be attached to either end of the cover and the proximity switch array and permanent magnet pack would then be positioned on the opposite side of the fitting.
Your next task is to mount the special MXD sex bolt. Be sure you have checked the previous Section which covers a situation that deviates from standard sex bolt installation. Then, note that the bolt includes two pins under the head which will go in two separately drilled holes for anti-rotation. The pins act as their own template. Unscrew the threaded base plate of the bolt and insert the bolt into the 1” hole which you should have previously drilled. Tapping the bolt head will cause the pins to mark the door. Remove the bolt and drill 3/16” (5MM) diameter