A
www.securitron.com | techsupport@securitron.com
© 2015, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company.
C
B
A
C
MODEL 62
MAGNET
A8B
ELECTROMAGNETIC LOCK – Model 62
1.75C2.9
MODEL 62
STRIKE
C
A6B
2.75C.5
Features
• 1,200 pounds of pull-apart
holding force
• Lifetime replacement warranty
• Power consumption of 250mA
@ 12VDC & 150 mA @ 24VDC –
3 Watts
• Automatic dual voltage, 12
VDC or 24 VDC, no field
adjustment required
• Instant release circuit, no
residual magnetism
• Surface mounts using only a
drill and allen wrench
• Fully sealed electronics, tamper
proof & weather proof
• Mounted using steel machine
screws into blind finishing nuts
• Architectural brushed stainless steel finish
• Polished brass, clear anodized, & polished stainless finish dress covers available
• Hardware accessories include brackets, housings, and dress covers as needed for every
opening type
• Ten feet of jacketed stranded conductor
• Lock and strikes plated to provide corrosion resistance
• Fail Safe
• UL listed

ELECTROMAGNETIC LOCK – Model 62 (cont’d)
Options
• Bondstat Form ‘C’ – Instantaneous lock status sending without the use of auxiliary
switches or reed relays
• DPS Door Status – Integrated door reed switch w/ built in resettable polyswitch
• Face Mount – Mounting holes on the face of the lock for mounting on inswing doors and
gates
• Conduit fitting
• Offset Strike
• Split Strike
Operating Temperature
-40 to 60C [-40 to 140F]
How to Order
Part Number
M62 Maglock Model 62, Dual Voltage
M62F Maglock Model 62, Face Mount
M62FG Maglock Model 62, Face Mount Conduit Fitting
M62FGD Maglock Model 62, Face Mount, Conduit, Door Position
M62FD Maglock Model 62, Face Mount, Door Position
M62G Maglock Model 62, Conduit Fitting
M62G-OS Maglock Model 62, Conduit Fitting Offset Strike
M62G-SS Maglock Model 62, Conduit Fitting Split Strike
M62-OS Maglock Model 62, Offset Strike
M62B Maglock Model 62, Bondstat
M62BD Maglock Model 62, Bondstat, Door Position
M62D Maglock Model 62, Door Position
M62FB Maglock Model 62, Bondstat Face Mount
M62FBD Maglock Model 62, Face Mount, Bondstat, Door Position
M62FGB Maglock Model 62, Bondstat Face Mount Conduit Fitting
M62FGBD Maglock Model 62, Face Mount, Conduit, Bondstat, Door position
M62GB Maglock Model 62, Bondstat Conduit Fitting
M62GB-OS Maglock Model 62, Bondstat Conduit Fitting Offset Strike
M62GB-SS Maglock Model 62, Bondstat Conduit Fitting Split Strike
M62B-OS Maglock Model 62, Bondstat Offset Strike
M62B-SS Maglock Model 62, Bondstat Split Strike
M62-SS Maglock Model 62, Split Strike
DM62 Maglock Model 62, Two M62 in Single Housing
DM62B Maglock Model 62, Double, Bondstat
DM62D Maglock Model 62, Double, Door Position
DM62BD Maglock Model 62, Double, Bondstat, Door Position
Product Description

ARCHITECTURAL SPECIFICATION – Electromagnetic Lock Model 62
2.x MAGNETIC LOCKS
A.
B. Locks shall be capable of providing a pull-apart or tensile holding force of at least 1,200
C. Electrom agnetic locks shall have a lifetime replacement warranty.
D. Locks shall be dual voltage with no field adjustment necessary to select voltage.
E. Locks shall not consume more than three and (3 W) watts of power (250mA @ 12VDC) and
F. Locks shall not exceed 42 cubic inches (8 inches x 3 inches x 1.75 inches) in size.
G. Locks shall be fully sealed in resin to provide tamper and weather proofing.
H. Mount locks using two .25 inch x 2.25 inch machine screws into blind finishing nuts with steel
I. Mount strike plates to provide a "floating" movement to assure automatic self-alignment with
J. Finish is architectural brushed stainless steel, other finishes available by selecting optional
K. Hardware accessories shall include brackets, housings, and dress covers.
L. Ten feet of jacketed strand ed conductor shall be provided for electrical connection.
M. Anti-tamper caps shall be provided for any exposed holes.
N. The locks and strikes shall be plated to provide corrosion resistance.
All electromagnetic locks shall be manufactured by Securitron Magnalock Corp., Sparks, NV,
an ISO 9001 certified manufacturer.
pounds. A laboratory test certifying the minimum holding force shall be submitted by the
manufacturer upon request.
(150mA @ 24VDC).
threads that extend through the entire body of the lock.
the lock.
dress covers.