Seco-Larm SD-7213-GSP, SD-7213-RSP, SD-7113-GSP User Manual

Green pushbutton SD-7113-GSP SD-7213-GSP
Slimline Plate Single Gang Plate
Red pushbutton SD-7113-RSP SD-7213-RSP
Slimline Plate Single Gang Plate
Standard Button with Guard Ring
SD-7173-SSP SD-7273-SSP
Slimline Plate Single Gang Plate
No
Power
Required
Request-to-Exit Plate
with Pneumatic Timer
Manual
ENFORCER® Request-to-Exit Plate with Pneumatic Timer
Pneumatic timer has these special features:
Functions entirely without electricity. Excellent for installs where supplying
additional timer power is inconvenient.
Reliable American made pneumatic
components.
Stainless steel single gang or slimline plate.
English EXIT and Spanish SALIDA
printed on plate.
Timer adjustable for 1~60 second. Green or red mushroom cap pushbutton.
(SD-7113-xSP / SD-7213-xSP)hi
Standard button with guard ring.
(SD-7173-SSP / SD-7273-SSP) hi
Timer
Pneumatic: 1~60 s*
Switching capacity
5A@125VAC
Operating temperature
32°~131° F (0°~55° C)
Wiring Red
2x N.C. #18 AWG 9 (230mm)
White
2x N.O. #18 AWG 9 (230mm)
Dimensions
(height x width)
Single gang
41/2”x23/4” (115x70 mm)
Slimline
41/2”x11/2” (115x39 mm)
Dimensions
(depth)
SD-7x13-GSP
(Mushroom Pushbutton)
31/2” (88mm)
SD-7x73-SSP
(Guard Ring)
2 (50mm)
Parts List:
Dimensions:
1x Request-to-Exit Plate
with Pneumatic Timer
1 x Manual
2 x Mounting screws
41/2”
(115mm)
31/2”
(88mm)
2”
(50mm)
23/4”
(70mm)
11/2”
(39mm)
Introduction:
The ENFORCER SD-7X13-XSP series Request-to-Exit Plates with Pneumatic Timer is ideal for applications where providing power to a timer is inconvenient, hazardous or not conforming with local codes and ordinances. Adjusting the time is easy via a timing screw and can be performed on the spot without tools.
Features:
Specifications:
*Note: Time is precise to within ±10% for constant temperature and may change according to environmental factors.
2 SECO-LARM® U.S.A., Inc
ENFORCER® Request-to-Exit Plate with Pneumatic Timer
Power Supply
RTE Plate w/ Pneumatic Timer
Electronic Lock
Use ENFORCER Request to Exit Plates with Pneumatic Timer anywhere zero-spark switching is required.
For N.C. (fail safe) operation,
connect the red wires.
EAP-5D1Q
Access Control Power Supply
ENFORCER Series
Electromagnetic Lock
(SD-7173-SSP Shown)
Timing Screw
Timer Assembly
Installation:
1. Find a suitable location for the pneumatic request-to-exit plate.
2. The pneumatic request-to-exit plate can be either surface mounted or flush mounted.
3. Wire the request-to-exit plate as described below under Wiring.
4. Adjust the timer as described below under Adjusting the Timer.
5. Test the function of the exit plate and timer, as well as the timer delay.
6. Mount the request-to-exit plate in a back-box or other suitable housing.
Wiring
1. For N.C. operation (fail safe), connect the red wires to the electronic lock or other device.
2. For N.O. operation (fail secure), connect the white wires to the electronic lock or other device.
Adjusting the Timer:
1. Locate the timing screw as shown in the figure to the right.
2. Using fingers or a flat screw driver, gently turn the timing screw
as so:
a. Increase delay: Tighten the screw clockwise b. Decrease delay: Loosen the screw counterclockwise
Note: Do not over tighten or over loosen the timing screw. If screw
becomes very loose, retighten it until it feels secure.
3. The minimum delay time is approximately 1 second, and the
maximum delay time is approximately 60 seconds. Use a stop watch to adjust the time to suit the application.
Example Installation:
SECO-LARM® U.S.A., Inc 3
ENFORCER® Request-to-Exit Plate with Pneumatic Timer
Maglocks
E-941SA-600
(shown)
Electronic Door
Strikes
SK-990AQ
(shown)
Digital Keypads
SK-2323-SDQ
(shown)
No-Touch Exit Plates
SD-9263-KSVQ
(shown)
Central Receiver
SK-910RC4Q
Weatherproof
Transmitter Box
SK-919TPWFEUQ
Wireless Reflective
Beam Sensor
E-931-S45T19Q
Wireless Exit Plates
SD-8202GT-PEQ
(shown)
PITSW1
MiSD-7xx3-xSP-
1101.docx
Order Part #763-172-2%
Also Available from SECO-LARM:
WARRANTY This SECO-LARM product is warranted against defects in material and
workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2011 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.