Seco-Larm SD-7202BC-HC Specsheet

®
1
ENFORCER SD-7202BC-HC
Handicap Push-to-Exit Button
with Stainless Steel Plate
FEATURES
 Large (2 square), illuminated Handicap style
button.  Easily recognized blue A.D.A. button.  Illuminated with a long-life bulb, replacement bulb
included.  Momentary switch, S.P.D.T., N.O./N.C. contacts
rated 10 Amps at 125 ~ 250 VAC.  Includes stainless-steel single-gang face plate.  Includes five color-coded, 12-inch wire leads with
easy-to-attach spade lugs for fast installation.
INSTALLATION
1. Run four wires through the wall to a single-gang back-
box (not included):
a. Two wires for 12VDC or 24VDC for the light.
b. One wire from either the N.O. or N.C. terminal of an
alarm or access control system which can unlock an electrically-controlled lock.
c. One wire from COM terminal of the alarm or access
control system.
2. Connect four colored wires to the switch (see fig. 1):
a. 2 x GREEN wires, one each to the brass-colored spade
connectors on each side of the black switch.
b. GREEN/WHITE wire to N.C. connector on black switch
(if needed).
c. BLUE/WHITE wire to N.O. connector on black switch
(if needed).
2.125
(54mm)
d. WHITE wire to the COM connector on the black switch.
3. Connect the four colored wires to wires from the alarm or access control system and the lights power source (see fig. 1):
a. 2 x GREEN wires - To 12VDC or 24VDC source. If 24VDC
is used, then be sure to use the supplied resistor on either one of the two GREEN wires.
b.
GREEN/WHITE wire - To the N.C. terminal of the alarm or access control system (if needed).
c. BLUE/WHITE wire - To the N.O. terminal of the alarm or
access control system (if needed).
d. WHITE wire - To COM terminal of alarm or access control
system.
4. Screw the plate into the back-box, taking care not to crimp the wires.
4.5 (114mm)
2.75 (70mm)
2
2 (51mm)
2
2
22
2 (51mm)
Included in this box:
Five color-coded, 12-inch, AWG 18 wire leads with easy-to-attach spade lugs for fast installation.
Stainless-steel single-gang plate.
Replacement bulb (12V, 1.2W, 15,000-hour life).
Resistor (150 ohm, 1 Watt).
SECO-LARM® U.S.A., Inc.,
SECO-LARM's policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. Copyright © 2002
Fig. 1
Connections:
Green ( light bulb) 12V or 24V (requires resistor)*
Blue/White (for N.O.) (Top Lug) Green/White (for N.C.)
(Bottom Lug)
*Note: Use 150-ohm, 1-watt resistor on either
16842 Millikan Avenue, Irvine, CA 92606
SECO-LARM® U.S.A., Inc.
Green ( light bulb) 12V or 24V (requires resistor)*
one of Green wires for 24-volt operation.
All rights reserved.
file: DTP/MANUAL/MiSd7202BC-HC.p65 Order Part # 763-147/919
White (COM) 10A @ 125~250VAC