Seco-Larm RM-R100-TH2Q User Manual

Overview
:
:
P
rint your own message plate on
card stock, no
Message
Plate
Transparent
lens
Spacer
Plate
RM
-
R100
-
TBQ
1. Find a suitable location for the W
all-Mount
Help
The Wall
-
Mount
Help Button
has a dual
-
color LED
RM
-
R100
-
TH2Q
Use as a service button in restrooms, fitting or
Use to reset a 1
-
Room Indicator remotely
, after it has
Wall-Mount Help Button
Features:
changing rooms, waiting rooms, etc.
Powered by 9VDC battery (included) LED Indicates transmission and low battery Desktop or wall mounted Transmits up to 100ft (30m)
LED Indicator
Off: No transmission
9V Alkaline
battery
Request
Battery clip
Blue: Transmitting Red: Low battery
Push
for Help
button
Indicator Remote
Features:
been triggered by a Wall-Mount Help Button.
Powered by CR2032 battery (included) LED Indicates transmission Belt clip or wall mounted Transmits up to 500ft (150m)
Changing the Message Plate:
thicker than the included plate, and trim to fit.
1. Use a screwdriver to pry off the transparent lens.
2. Keep the spacer plate in place, and replace current plate with the desired message plate.
3. Carefully snap the lens assembly back on.
Button. Do not house in a metal box.
2. Pair the Wall-Mount Help Button with an RM-R100-RB1Q, or an SK-910 (433.92MHz) series receiver, and test before mounting. NOTE: See reverse side for pairing instructions.
3. The Wall-Mount Help Button can either be wall mounted (taller side of back box on bottom), or placed on a desktop (taller side on top).
4. According to the appropriate orientation above, secure the Wall-Mount Help Button to the back box with the two included screws. Apply the included rubber feet for desktop applications.
Changing the Battery (RM-R100-TBQ):
that illuminates blue when the button is pressed, and red when the battery begins to run low. To change the battery:
1. Remove the two screws from the front of the plate and remove the plate from the back box.
2. Remove the battery clip from the 9V battery and remove the battery from the bracket.
3. Place the new battery in the bracket and snap the battery clip to the new battery.
4. Test the unit with the new battery. The LED should illuminate blue.
5. Put the plate back in the back box and secure it to the back box using the screws on the front.
ENFORCER Room Monitor Accessories
Parts List:
How to Pair to
a 1-
Room Indicator
(RB-R100
-
RB1Q)
:
FCC COMPLIANCE
STATEMENT
FCC ID:
K4ER100TBQ
(RM-R100-TBQ) and K4E939TP4H (RM
-
R100-TH2Q)
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO
THIS DEVICE MUST ACCEPT
Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s
IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device
is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements
PITSW1
Order Part# 763
-
190%
MI_RM-R100-TxxQ_190123.docx
16842 Millikan Avenue, Irvine, CA 92606
Website:
www.seco
-
larm.com
Phone: (949) 261
-
2999 | (800) 662
-
0800 Email: sales@seco
-
larm.com
NOTICE:
The SECO
-
LARM policy is one of continual development and improvement. For that reason, SECO
-
LARM reserves
All trademarks are the
Inc. All rights
WARRANTY:
This SECO
-
LARM product is warranted against defects in material and workmanship whil
e used in normal
service
for
one (1) year from the date of sale to the original customer.
Each channel of an Indicator can learn the codes of up to 15 different
buttons
on a first
-
in, first
-
out basis. The
1x Wall-Mount Help Button
1x
Back box
2x Mounting screws
2x
Wall anchors
4x
Adhesive rubber feet
2x
Wall
plate screws
1x 9V Alkaline battery
1x
Manual
1x
Indicator
Remote
1x
Bracket /
Belt clip
1x Manual
RM-R100-TBQ:
RM-R100-TH2Q:
procedure for pairing a new Wall-Mount Help Button / Indicator Remote to a Room Indicator is as follows:
1. Once the Indicator has been powered on for over 5 seconds, press the pairing button of the service
channel for 3 seconds or more. The Indicator's channel LED will start to flash quickly.
2. While the LED is flashing, press the button to be learned one time. The Indicator's channel LED will flash
once to indicate the button has been successfully paired. After the button has been paired, the Indicator will automatically exit learning mode. Repeat the above steps to pair additional Buttons/Remotes.
NOTES:
The channel's LED indicator will flash a maximum of 30 seconds. If no device is paired during this time,
the Indicator will automatically exit learning mode, and the LED will turn off.
If the Wall-Mount Help Button / Indicator Remote being paired has already been paired before, the
channel indicator LED will turn steady ON and then start flashing. It will not be paired twice.
One channel can be paired with a maximum of 15 buttons. If you attempt to pair a sixteenth button, the
earliest button paired will be deleted and the new button will be paired.
Troubleshooting:
LED does not light
LED illuminates, but does not trigger/reset indicator
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
authority to operate the equipment.
and void user’s authority to operate the device.
the right to change specifications without notice. SECO-LARM is also not responsible for misprints. property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2019 SECO-LARM U.S.A., reserved.
®
U.S.A., Inc.
2 SECO-LARM U.S.A., Inc.
Check battery connection
Replace battery
Ensure Wall-Mount Help Button is not housed in a metal box
Test closer to the receiver Clear codes from Indicator and re-pair devices.
Loading...