Seco-Larm RA-4961-PBQ User Manual

®
RA-4961-PBQ
Wireless Pushbutton
Manual
For use with RA-4961 series receivers
Up to 1,000ft (305m) transmission range*
Easy installation
Can be used as a wireless doorbell
* Transmission range will vary depending on installation and operating environment.
CBA Wireless Pushbutton
/16"
Overview:
Specifications:
Parts List:
/16"
1x Wireless Pushbutton
1x CR2032 Battery
Model number
4961-PBQ
Frequency
914.8MHz
Transmission range*
Up to 1,000ft
(305m)
Channels
Power supply
CR2032 Battery
(Included)
Curre
nt
Standby
0.2µA
Active
16mA
Estimated battery life
400 days (3 triggers/day)
L
ow battery indicator
Zone LED
on receiver blinks continuously
IP rating
IP45
Operating temperature
-
20º~60º C)
Dimensions
mm)
*Transmission range will vary depending on installation and operating environment.
Dimensions:
Battery
draw
(87mm)
(34mm)
11
(18mm)
11
(18mm)
(78mm)
Front (Cover on)
2 SECO-LARM U.S.A., Inc.
Front (Cover off)
Pushbutton Activation LED
holder
CBA Wireless Pushbutton
Installing the
Battery
:
1. Remove the front cover of the pus
hbutton by inserting a paperclip in the notch at the top of the
Note: Low battery is indicated on the receiver. Refer to the RA
-
4961-K1Q or RA-4961-VPQ for more information.
Pairing
the Pushbutton:
1. Follow the
pairing
instructions for the RA
-
4961-K1Q receiver or RA
-
4961-VPQ wireless
Installation
:
1. Remove the front cover of the pushbutton by inserting a paperclip in the notch at the top of
Insert paperclip
in
notch
Insert paperclip
in notch
Mounting
holes
Battery
holder
the unit. Push down on the paperclip with force and pull the top of the front cover from the pushbutton.
2. Mount the pushbutton to a wall or other surface using screws (not included) through the two
mounting holes.
3. Once the pushbutton has been mounted, snap the front cover onto the unit.
Remove cover
vibrating receiver to enter pairing mode. (Refer to RA-4961-K1Q or RA-4961-VPQ manual for detailed instruction).
2. Press the pushbutton.
3. The receiver will beep once and cycle to the next channel to confirm successful pairing.
unit. Push down on the paperclip with force and pull the top of the front cover from the pushbutton.
2. If there is a previous battery installed, use a fingernail or small object to remove the battery
from the battery holder.
3. Slide a CR2032 battery into the battery holder, making sure to observe correct polarity
(positive faces out).
4. Snap the front cover onto the pushbutton.
Remove cover
SECO-LARM U.S.A., Inc. 3
CBA Wireless Pushbutton
NOTICE:
The infor
mation and specifications printed in this manual are current at the time of publication. However, the
LARM reserves the right to
Trademarks
, in whole or
LIMITED WAR
RANTY:
This SECO
-
LARM product is warranted against defects in material and workmanship while used in
LARM’s obligation is limited to the
LARM. This Warranty is
on,
LARM determines that such equipment is
not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of
LARM’s
LARM be liable for any special, collateral, incidental, or consequential personal or property
SECO
-
LARM
Phone: (949) 261
-
2999 | (800) 662
-
0800 Email: sales@seco
-
larm.com
Also Available from SECO
-
LARM:
FCC COMPLIANCE STATEM
ENT:
FCC ID: YAHDCX
-
800
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT
NCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Notice:
The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority
F exposure compliance requirements, no change
to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the
Wireless
Wireless
Alert
Wireless
Wire
less
Wireless
Wireless
Outdoor PIR Sensor
RA-4961-DSQ
Mailbox/Tilt Sensor
RA-4961-MBQ
Magnetic Contact
RA-4961-MCQ
Indoor PIR Sensor
RA-4961-PRQ
System
RA-4961-K1Q
Vibrating Receiver
RA-4961-VPQ
ANY INTERFERENCE RECEIVED, I
to operate the equipment. IMPORTANT NOTE: To comply with the FCC R
RF exposure requirements and void user’s authority to operate the device.
normal service for one (1) year from the date of sale to the original customer. SECO­repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO­void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alterati improper or abnormal usage, or faulty installation, or if for any other reason SECO-
SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO­option. In no event shall SECO­damage of any kind to the purchaser or anyone else.
SECO-LARM policy is one of continual development and improvement. For this reason, SECO­change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. are the property of SECO-LARM USA Inc. or their respective owners. Copyright © 2015 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied in part, without the written permission of SECO-LARM.
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
PIHVK1
MiRA-4961-PBQ_151001.doc
4 SECO-LARM U.S.A., Inc.
Loading...