RA-4961-DSQ
Wireless Outdoor PIR Sensor
Manual
For use with RA-4961 series receivers
• Wirelessly monitor driveways, walkways
or other areas
• Up to 1,000ft (305m) transmission range*
• Programmable activation time
* Transmission range will vary depending on installation and operating environment.
Programmable sensing range up to
40ft (12m)
• Runs on batteries for a convenient,
wireless installation
• Adjustable mounting angle

CBA Wireless Outdoor PIR Sensor
1x Wireless Outdoor PIR Sensor
300 days (3 triggers/day)
Zone LED on receiver blinks continuously
13' (4m) / 23' (7m) / 26' (8m) / 39'
*Transmission range will vary depending on installation and operating environment.
draw
(120mm)
(97mm)
(Removable)
(98mm)
Sleep timer
compartment
Range
Sensor
Filter
button
(70mm)
Side Back (Cover removed) Front
Sunshield
base
2 SECO-LARM U.S.A., Inc.

CBA Wireless Outdoor PIR Sensor
1. Select the location where the sensor will be mounted.
1. To access programming functions, the cover of the se
1. Use the DIP Switches to program various functions.
Programming the DIP Switches
– The detection speed of the sensor can be set for varying object speeds.
– When ON the sensor will be inactive during the day or when
near a bright light source.
– The sensor will not reactivate for the
set amount of time after the sensor is triggered.
– The range of the sensor can be set for
installation environments.
2. The sensor should be mounted 6~9 feet (2~3 meter) above ground, have
a clear view of the desired detection area, and be safe from water.
3. Use the four included mounting screws to mount the sensor to the surface.
4. Point the sensor toward the desired detection area (lens cover can be
removed to widen the detection angle).
must be removed.
2. Remove the sunshield from the sensor.
3. Using a screwdriver, remove the screws from the front of
the sensor and remove the cover.
2. Refer to the guide below for DIP switch programming.
7s*
30s
Sleep timer
(2~3m)
Range
Filter
Range
13' (4m) 23' (7m)
(0.5~1 m/s)
ON* OFF
*Default Setting
s
39' (12m)* 26' (8m)
(1~2 m/s)
Sensor
RA-4961-K1Q receiver or RA-4961-VPQ wireless receiver to
enter pairing mode. (Refer to the RA-4961-K1Q or
RA-4961-VPQ manual for detailed pairing instructions).
2. Press the "Test" button. This will activate the sensor for pairing.
3. The receiver will beep once and cycle to the next channel to confirm successful pairing.
SECO-LARM U.S.A., Inc. 3
button

CBA Wireless Outdoor PIR Sensor
1. Remove the sunshield from the sensor.
Using a screwdriver, remove the screws from the front
LARM reserves the right to
e reproduced or copied, in whole or
LARM product is warranted against defects in material and workmanship while
LARM’s obligation is limited to
cal or electrical misuse or abuse, neglect, repair or
LARM determines that such
LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at
2.
of the sensor and remove the cover.
3. Place 4x AA batteries (not included) in the battery
compartment, making sure to observe correct polarity.
4. Replace the cover and screws.
5. Replace the sunshield.
Note: Low battery is indicated on the receiver. Refer to the RA-4961-K1Q or RA-4961-VPQ for more information.
Alert System
RA-4961-K1Q
Vibrating Receiver
RA-4961-VPQ
Magnetic Contact
RA-4961-MCQ
Pushbutton
RA-4961-PBQ
Indoor PIR Sensor
RA-4961-PRQ
Mailbox/Tilt Sensor
RA-4961-MBQ
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment. IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements,
no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device
exceeding the RF exposure requirements and void user’s authority to operate the device.
used in normal service for one (1) year from the date of sale to the original customer. SECOthe repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
is void if damage is caused by or attributed to acts of God, physi
alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECOequipment is not operating properly as a result of causes other than defects in material and workmanship.
obligation of SECO
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or co
personal or property damage of any kind to the purchaser or anyone else.
SECO-LARM policy is one of continual development and improvement. For this reason, SECOchange specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
are the property of SECO-LARM USA Inc. or their respective owners.
Copyright © 2015 SECO-LARM U.S.A., Inc. All rights reserved. This material may not b
in part, without the written permission of SECO-LARM.
-
The information and specifications printed in this manual are current at the time of publication.
This SECO-
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
Phone: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com
MiRA-4961-DSQ_150916.doc
4 SECO-LARM U.S.A., Inc.
PIHVK1