ENFORCER Wireless Entry Alert System
LARM is not responsible for compliance with such
Installing the Optional Solar Charger (E-931ACC-SPQ)
charging
indicator LED
compartment
:
1. Install the solar panel in an area exposed to sunlight.
2. Use the included Phillips screwdriver to remove the side
panel of the sensor.
Install the 3.7V lithium-ion battery included with the solar
3.
charger into the sensor and replace the side panel.
4.
Connect the solar charger’s DC plug into sensor’s DC jack.
5. When battery is charging, the charging indicator LED will
turn ON. The LED will turn OFF when the battery is fully
charged or when the sensor’s DC jack is unplugged.
Attach the bracket to the solar panel by twisting into the
6.
back of the solar panel until tight. Adjust the solar panel
and then tighten the adjustment knob.
Sample Applications:
Troubleshooting:
Sensor red LED does not turn ON
Sensor red LED does not turn OFF
Speaker does not sound
CAUTION:
This sensor was not designed to prevent bodily injury or loss of life. Use of this sensor in certain security applications may be regulated by local laws
•
Check power adapter and cable.
•
Make sure solar charger is installed in an area exposed
to sunlight (E-931ACC-SPQ Only).
Remove shiny metallic object near installation site.
•
Realign the sensor and reflector.
Clean the sensor cover and remove any obstacles.
•
Make sure speaker is switched to Chime or Alarm.
•
If using Alarm, make sure alarm duration is long enough.
•
Try pairing the sensor to the speaker. See Pairing the Sensor
and Optional Additional Speaker on page 3.
Driveway
E-931CS22RFCQ
Wireless Entry Alert System
Manual
FCC COMPLIANCE STATEMENT FCC ID: K4E931CS22RF
Information to the user: This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his or her own expense.
WARRANTY:
the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned,
transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating
properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be
limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damage of any kind to the purchaser or anyone else.
NOTICE
development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for
misprints or typographical errors.
Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission
This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from
: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA, 92606 Website: www.seco-larm.com
Tel: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com
4 SECO-LARM U.S.A., Inc.
MiE-931CS22RFCQ_1404
For monitoring a driveway or for use as an entrance indicator
• No wiring necessary between sensor and speaker
• Sensor range: Up to 22ft (7m)
• Sensor is weatherproof for outdoor use
• Speaker makes chime or alarm sound if beam is interrupted
• Wireless range: Up to 328ft (100m) between the sensor and speaker
• Each sensor can be paired with an unlimited number of speakers
• Each speaker can be paired with up to 5 sensors
Note: Model numbers that end with “Q” or that have a round green “Q” sticker signify RoHS-compliant products.

The ENFORCER Wireless Entry Alert System is a self
speaker installed up to 328
property and an optional solar charge
depending on the installation and operating environment.
depending on the installation and operating environment.
Wireless Entry Alert System
Wireless Entry Alert System
the same mounting bracket.
contains a reflective photoelectric beam sensor that, when tripped, communicates wirelessly with a
) away*. An additional speaker may be installed to alert more than one area
1x Sensor mounting bracket
) away*. An additional speaker may be installed to alert more than one area
r may be installed with the sensor for
r may be installed with the sensor for
install alert system for commercial or home
ENFORCER Wireless Entry Alert System
Connecting the Optional Counter
-
f
m
-
o
.
*
Installation:
1. Install the reflector and sensor so they face each other about 2ft (61cm) off the ground.
2. Install the speaker within 328ft (100m) of the sensor.
3. Connect an included power adapter to the sensor. If optional solar charger is used, see pg. 4, Installing the Optional
Solar Charger.
4. Connect an included power adapter to the speaker.
5. To find the correct alignment, slowly adjust the angles of the sensor and reflector.
NOTE: Alignment is correct when the red LED turns OFF.
Mounting:
Sensor Reflector Speaker
Mounting with Bracket Mounting Directly to Wall (Speaker Only)
9
3
/4”
/
/
2
15
3
/
4
9
/
16
1. Attach the sensor, reflector, or speaker to their respective brackets by using
the included bolts and nuts.
2.
Mount the bracket to the wall using two of the included mounting screws.
Programming the Speaker:
Choose between Chime, Alarm, and Off using the alert tone selection switch on the side of the speaker.
1.
2. Adjust the volume by using the included Phillips screwdriver to turn the volume adjustment screw. Turning clockwise
increases the volume; counter-clockwise decreases the volume.
3. Adjust the timer by using the included Phillips screwdriver to turn the timer adjustment screw. Turning all the way
clockwise will set the timer for 30 seconds; turning all the way counter-clockwise will set the timer for three seconds.
*
e
1
/
”
1
3
”
4
9
/
”
7
/
8
3
2
”
8
1
/
3
/
2
/
16
”
16
1
3
2
/
”
”
4
NOTE: Timer mode only applies if Alarm is chosen as the alert tone.
Pairing the Sensor and Optional Additional Speakers (E-931ACC-SFQ):
Use one of the two methods below to pair the optional additional speaker with the sensor.
NOTE: The speaker included with the Wireless Entry Alert System is pre-paired with the sensor.
Method 1:
1.
Use the included mode adjustment
pin to press and hold the mode
switch until you hear a long beep
from speaker. This means the
speaker is in the learning mode.
Trigger the sensor by breaking the
2.
beam. The speaker will beep once.
After 10 seconds, the speaker will
3.
make one long beep indicating
successful pairing.
Method 2:
Remove the side panel of the
1.
sensor with the included small
Phillips screwdriver.
Perform the point 1 of “Method 1”
2.
and then press sensor’s learning
button once. The speaker will beep
once.
3.
After 10 seconds, the speaker will
make one long beep indicating
successful pairing.
IMPORTANT: When pairing additional speaker, release the mode switch immediately after two seconds and hearing the
long beep. Pressing the mode switch for more than five seconds will delete the memory.
E
-
-
-
(E-931ACC-CQ)
1. Connect the plug from the counter to the counter output jack of the speaker.
2. Test the counter. Each time the beam is broken, the counter should
automatically increase by 1.
-
E
-
-
3. Manually add or subtract 1 by pressing the “+” or “-“ buttons
4. Reset the counter by pressing “RESET”.
mounting
holes
1. Drill included screw into wall.
2. Hang speaker on screw.
Learning button
Clearing Memory:
Use the included mode adjustment
1.
pin to press and hold the mode
switch until you hear a long beep
and two short beeps after five
seconds.
Release the mode button and the
2.
memory has been cleared.
-
SECO-LARM U.S.A., Inc. 3