Seco-Larm CS-PD115-PAQ User Manual

ENFORCER IR Proximity Sensor
Sample Applications:
Anti-Theft
Access Control
Place the sensor under a painting or other
Mount the sensor to a wall or plate in a
protected
IR
IR Proximity
NOTICE
:
ole or
WARRANTY:
used in normal
obligation is limited to the repair or
This Warranty is void if
ct, repair or alteration,
LARM determines that such equipment is
ation of
LARM’s
LARM be liable for any special, collateral, incidental, or consequential personal or property
SECO
-
LARM
Proximity Sensor
Sensor
EXIT
CS-PD115-PAQ
IR Proximity Sensor
Manual
valuable object. If the object is removed from the sensor, the sensor will trigger an alarm to alert the owner that the item is out of place.
area. A user can wave his or her hand in front of the sensor to unlock an electronic door lock, allowing sanitary, protected egress.
Check that there are no objects in front of the sensor
Adjust the sensor’s range to be shorter (see IR Range and The indicator light is continuously green
The indicator light will not turn green
service for one (1) year from the date of sale to the original customer. SECO-LARM’s replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, negle improper or abnormal usage, or faulty installation, or if for any other reason SECO­not operating properly as a result of causes other than defects in material and workmanship. The sole oblig SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at SECO­option. In no event shall SECO­damage of any kind to the purchaser or anyone else.
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in wh in part, without the written permission of SECO-LARM.
This SECO-LARM product is warranted against defects in material and workmanship while
The information and specifications printed in this manual are current at the time of publication. However, the
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com Phone: (949) 261-2999 | (800) 662-0800 Email: sales@seco-larm.com
4 S
Trigger Time Settings on page 3)
Check that the power supply’s voltage is 12~24 VDC
Adjust the trigger time setting – a long delay or enabling
toggle mode could affect the sensor’s operation
Adjust the sensor’s range to be longer (see IR Range and
Trigger Time Settings on page 3)
Check that the power supply’s voltage is 12~24 VDC
MiCS-PD115-PAQ_1405.docx
E
CO-LARM U.S.A., Inc.
PITSW2
Order Part # 763-181%
Triggers a warning or locking device when the sensor is triggered
Form C relay output (1A@30VDC)
Adjustable output time (1~20 s) or
toggle mode
Adjustable sensing range 2”~6” (5~15 cm)
12~24 VDC Operation
Front panel IP65 protection for
outdoor use
ENFORCER IR Proximity Sensor
Introduction:
A user can wave his or
Features:
Specifications:
Overview:
Model CS-PD115-PAQ Type IR Proximity sensor
Sensing range
2”~6” (5~1
5 cm)
Red Standby
Green Triggered
Alarm output
1A@30VDC
Output time
1~20
s or Toggle
Operating voltage
12~24 VDC
Current draw
30mA@12
VDC Operating life
100,000 Hours or 1,000,000 uses
Operating temperature
14°~158° F (
-
10°~70° C
) Dimensions
13/8”x7/8”x7/8” (35x23x23 mm)
Weight
0.35-oz (10g)
Parts List:
/8”
/4”
Indicator LED
1x IR proximity sensor
E
Note:
To
ensure proper operation
, make sure no objects sit or come within 11
IR proximity sensor
Installation:
Wiring:
IR Range and Trigger Time Settings:
Sensor
O-ring
Sample Wiring:
Wiring to an alarm for anti
-
theft*
Wiring to a
N.O.
door strike for no
-
touch egress
/4” (19mm)
Diameter hole
Near
2”(5cm)
Adjustable range
Far
6”(15cm)
Adjustable
(Default:
Short
(1 sec)
N.C. Output
N.O. Output
COM
Negative (
Positive (+)
(Red wire)
wire)
wire)
wire)
(Red wire)
wire)
**
Suggest
c
onnect
ing a
diode and metal oxide varistor
(not included)
as close as possible and in parallel with
. This absorbs possible electromagnetic interference to prevent damaging the
/4” (30cm)
Mounting surface
Hex nut
Toggle mode
: Set the
trigger time
Long
(20
sec)
–)
+
(Red wire)
(Brown
wire) (
Green
wire) (
Blue wire) (
Purple
wire)
Power
Electric
Power
Door Strike
the controlled
Diode
∗∗
MOV
∗∗
Alarm Control
(N.C. Input)
The ENFORCER IR Proximity Sensor is a compact sensor that can be programmed to trigger an alarm when an object (such as a valuable possession) is removed from the sensing area or unlock an electronic door lock when an object (such as a hand) is passed in front of the sensor. This flexibility makes the sensor ideal for both anti-theft and access control applications.
Anti-theft: Place the sensor under a painting or other valuable object. If the object is removed from the sensor, the sensor will trigger an alarm to alert the owner that the item is out of place.
Access control: Mount the sensor to a wall or plate in a protected area. her hand in front of the sensor to unlock an electric lock, allowing sanitary, protected egress.
S
Place the sensor behind a painting or under another valuable object for
Install the sensor near a door for no-touch egress
Filters out interference from other infrared sources
Form C relay output (1A@30VDC)
Programmable trigger time (1~20 s) or toggle mode
Programmable sensing range 2”~6” (5~15 cm)
Front panel IP65 protection for outdoor use
mall size allows for a wide range of applications
use as an anti-theft measure
3
(60° to the left and right) of the front of the
(Default: Far)
3
to avoid interference.
trigger time to maximum.
Short)
LEDs
13/8” (35mm)
7
(23mm)
2 S
3
(19mm)
1x Wiring harness 1x Hex nut 1x O-ring 1x Manual
Standby: Red Activated: Green
Sensor
E
CO-LARM U.S.A., Inc.
*Sensor covered (relay active) in normal state
output device
SECO-LARM U.S.A., Inc.
Positive (+)
Negative (–)
N.C. Output
COM
N.O. Output
Positive (+)
Negative (–)
N.C. Output
COM
N.O. Output
(Brown
(Green wire)
(Blue
(Purple
(Brown wire)
(Green
(Blue wire)
(Purple wire)
Supply
Supply
Panel
Power Supply
Door Strike
IR proximity sensor.
3
Loading...