2. Technische Daten
Staubsauger:
Gebläsemotor .......................................700 Watt
Unterdruck ...........................................165 mbar (1682 mm H2O)
Luftmenge ............................................45 l/s
Filtertüte ...............................................5,0 Liter, 3-lagig
Bürstenmotor ........... BS 360 ................175 Watt
BS 460 ................195 Watt
Arbeitsbreite .............BS 360 ................360 mm
BS 460 ................460 mm
Bürstenstreifen.....................................auswechselbar
Bürstenantrieb .....................................Zahnriemen mit
...........................elektronischem
...........................Überlastschutz
Höhe .....................................................1240 mm
Breite ....................... BS 360 ................360 mm
BS 460 ................460 mm
Gewicht .................... BS 360 ................8,8 kg
BS 460 ................9,4 kg
Ermittelte Werte gemäß EN 60335-2-69:
Vibrationspegel ....................................<= 2,5 m/s
2
Unsicherheit K .......................................0,2 m/s
2
Schalldruckpegel ..... BS 360 ................ < 70 dB(A)
BS 460 ................< 70 dB(A)
Schutzklasse ........................................II, doppelt insoliert
Vacuum Cleaner:
Vacuum Motor .......................................700 Watt
Suction ..................................................165 mbar (1682 mm H2O)
Air Flow ................................................45 l/s
Filter Bag ..............................................5,0 litres, 3-layer
Brush motor ............. BS 360 ................175 Watt
BS 460 ................195 Watt
Working width ........... BS 360 ................ 360 mm
BS 460 ................460 mm
Brush strip ............................................replaceable
Brush drive ...........................................non slip drive belt
...........................with electronic
...........................overload protection
Height ..................................................1240 mm
Width ........................ BS 360 ................ 360 mm
BS 460 ................460 mm
Weight ...................... BS 360 ................8,8 kg
BS 460 ................9,4 kg
Values determined according to EN 60335-2-69:
Vibration level ......................................<= 2,5 m/s
2
Uncertainty K ....................................... 0.2 m/s
2
Sound pressure level BS 360 ................< 70 dB(A)
BS 460 ................< 70 dB(A)
Protection ............................................double insulated