Sears 200.71450 User Manual

Page 1
OWNER’S
MANUAL
Model No.
200.71450
CAUTION:
Read and Follow All Safety Rules and Operating Instructions Before Every Use of this Product.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
50/15/2 AMP
MANUAL BATTERY
CHARGER
ENGINE STARTER with
BATTERY TESTER
Page 2
Table Of Contents
Warranty .................................................................... 1
Important Safety Instructions .................................. 2
Parts .......................................................................... 3
Before Using Your Battery Charger ........................ 4
Assembling your charger ...................................... 4
Plugging it in ......................................................... 5
Preparing your battery to be charged ................... 7
Please read this Owner’s Manual before using your Battery Charger.
The Sears model 200.71450, Manual Battery Charger/Tester/Engine Starter, offers a wide range of features to accommodate the needs for home or commercial use. This manual will show you how to use your charger safely and effectively. Please read and follow these instructions and precautions carefully.
Using Your Battery Charger .................................... 8
Setting the controls ............................................... 8
Charging your battery ......................................... 10
Calculating charge time ...................................... 12
Using the engine start feature ............................. 13
Maintenance and Care ........................................ 13
Troubleshooting ..................................................... 14
Warranty
FULL THREE-YEAR WARRANTY
If, within three years from the date of purchase this battery charger fails due to a defect in materials or work­manship, simply RETURN IT TO THE NEAREST SEARS STORE IN THE UNITED STATES, and Sears will repair or replace it, free of charge.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co., Dept 817WA, Hoffman Estates, IL 60179
Sch 517
1
Page 3
Important Safety Instructions
– SAVE THESE INSTRUCTIONS –
w
! WARNING
L
To reduce the risk of explosion, explosive gases, or injury while using your battery charger, follow the precautions listed below:
•Read all instructions and cautions printed on the
battery charger, battery, and vehicle or equipment using battery.
•Use charger only on lead-acid type rechargeable
batteries, such as those used in cars, trucks, trac­tors, airplanes, vans, RV’s, trolling motors, etc. This charger is not intended to supply power to a low voltage electrical system other than in an automotive application.
Use only attachments recommended or sold by
manufacturer. The use of attachments not recom­mended by the manufacturer may result in fire, electric shock, or injury.
Help us help you
Remember:
Place charger as far away from battery being
charged as the charger cables will permit.
Do not expose charger to rain or snow.
Never charge a frozen battery. If battery fluid (electro-
lyte) becomes frozen, bring battery into a warm area to thaw before you begin charging.
Never allow battery acid to drip on charger when
reading specific gravity or filling battery.
Never set a battery on top of the charger.
Never place charger directly above battery being
charged. The gases from the battery will corrode and damage the charger.
Never use charger for charging dry-cell batteries that
are commonly used with home appliances. These batteries may burst and cause personal injury.
Do not disassemble charger. Take it to a qualified
service professional if service or repair is required. Incorrect assembly may result in fire or electrical shock.
To reduce risk of electrical shock, unplug the
charger from the outlet before attempting any maintenance or cleaning.
Always charge battery in a well ventilated area.
Never touch the battery clamps together when the
charger is energized.
Never operate charger if it has received a hard blow,
been dropped, or otherwise damaged. Take it to a qualified professional for inspection and repair.
Be sure to position the charger power cord to
prevent it from being stepped on, tripped over, or damaged.
Never pull out the plug by the cord when unplug-
ging the charger. Pulling on the cord may cause damage to the cord or the plug.
Do not operate the charger if it has a damaged
power cord or plug. Have the cord replaced.
Personal Safety Precautions
For your own personal safety, please follow the follow­ing precautions:
Wear complete eye and clothing protection when
working with lead-acid batteries.
Be sure that someone is within range of your voice
to come to your aid if needed while you work with or are near a lead-acid battery.
Have plenty of fresh water and soap nearby for use
in case battery acid contacts your eyes, skin, or cloth­ing. If this happens, wash immediately with soap and water. Then get medical attention.
Avoid touching your eyes while working with a
battery. Acid particles (corrosion) may get into your eyes. If this occurs, flush eyes immediately with running cold water for at least 10 minutes. Then immediately get medical attention.
Sch 517
Remove all personal metal items from your body,
such as rings, bracelets, necklaces, and watches while working with a lead-acid battery. A battery can produce a short circuit current high enough to weld a ring (or the like) to metal, causing a severe burn.
Take care not to drop any metal tool or metal object
onto the battery. This may spark or short circuit the battery or another electrical device that may cause an explosion.
Always operate your battery charger in an open, well
ventilated area.
Never smoke or allow a spark or flame in the vicinity
of the battery or engine. Batteries generate explosive gases.
Neutralize any acid spills thoroughly with baking
soda before attempting to clean up.
2
Page 4
Parts
This section shows an illustration of your battery charger. Use it to become familiar with where all the parts are located, and what they look like.
Replacement Parts List Sears 71450
Item
Description
1
Handle
Negative (BLK) cable w/clamps
2
Positive (RED) cable w/clamps
3
4
Power Cord
5
Circuit Breaker
6
Rectifier Assembly
7
Transformer
Fan Motor
8
Wheel
9
10
Hub Cap
11
Axle
12
Axle mtg. bracket
13
Mounting Foot
Voltmeter
14
Ammeter
15
16
Rocker Switch (meter select)
17
Timer
18
Rotary switch
19
Rotary switch control knob
Timer control knob
20
Owner’s manual
21
Part Number
3599000286
3899000391
3899000408
90026001
399900065
2299000614
93026429
0099000063
0099000080
5200000008
0099000060
1199004366
1199003352
5399200002
5399100097
0499000050
0099000094
0499000051
0099000045
0099000096
0000000517
Wiring diagram
Sch 517
3
Page 5
Before Using Your Battery Charger
It is important to prepare your charger for use. This section will tell you how to assemble the charger, ground and connect the power cord, and prepare to charge a battery.
Assembling your charger
It is important to fully assemble your charger before use. Follow these instructions for easy assembly.
PARTS:
Two 10-32 thread cutting screws
Two 1¦4-20 thread cutting screws
Two wheels One axle Two axle caps Two axle brackets One handle One mounting foot
To attach the axle assembly:
1. Remove charger from packing materials and place
upside down on a flat surface. Attach mounting foot and secure with the two 1¦4-20 thread cutting screws.
TOOLS NEEDED:
3
¦8" wrench
(for mounting foot)
5
¦16" wrench
(for wheels) Hammer Phillips screwdriver
2. Hold axle upright on floor or work surface. Then, using a hammer, tap one of the plastic hubs onto the top end of the axle. Be sure to tap the hub on straight. Slide both wheels onto the axle with the hubs facing inward.
Sch 517
4
Page 6
3. Tap the other axle cap onto the opposite end of the axle and place the axle assembly onto the bottom of the charger. Place one end of the bracket into slot, then place the axle assembly under each bracket. Fasten the other side of the brackets using the two 10-32 screws provided.
To attach the handle:
Turn the charger right side up onto its foot and wheels. Remove the two top screws from each side of the charger and align with the screw holes on the handle. Attach the handle using the same screws.
Plugging it in
L! WARNING
Electrical Shock Hazard
Be sure that power cord fits properly into outlet. If not, have a qualified technician install a proper outlet. Never alter the AC cord or plug provided.
Improper connection can result in electrical shock.
Your charger should be grounded to reduce the risk of electrical shock.
Your charger is equipped with an electrical cord that has an equipment grounding conductor and a ground­ing plug designed to be used on a 120 volt circuit. The plug must be plugged into an outlet that has been properly installed and grounded in accordance with all local codes and ordinances.
Sch 517
5
Page 7
A TEMPORARY adapter may be used to connect the charger to a two-pole outlet if a properly grounded outlet is not available. Use the adapter ONLY until a properly grounded outlet can be installed by a qualified electrician.
DANGER: Before using an adapter as illustrated, be certain that the center screw of the outlet plate is grounded. The green colored grounding clip of the adapter must be attached by a screw to a properly grounded outlet. If unsure whether outlet is properly grounded, contact a professional electrician. If neces­sary, replace the original outlet cover screw with a longer one that will secure the grounding clip to the outlet cover and make a ground connection to the grounded outlet.
Using an extension cord
The use of an extension cord is not recommended. If you must use an extension cord, please make sure that you follow these guidelines:
•Make sure the pins on the plug of the extension cord
are the same number, size, and shape as those of the plug on the charger.
Use only 3-conductor (grounded) extension cord
when necessary.
•Check that the extension cord is properly wired and
in good electrical condition.
•Use the recommemnded minumum AWG (American
Wire Gauge) to be sure that wire size is large enough for the rating of the charger.
MINIMUM RECOMMENDED EXTENSION CORD
Length of Cord, in Feet 25 50 100 150
AWG* Size of Cord 18 14 12 10
*AWG=American Wire Gauge
Sch 517
6
Page 8
Preparing your battery to be charged
It is important that you read and follow these guidelines while you are preparing to charge your battery.
Make sure that you have a 12 volt or 6 volt lead-acid
battery. Set the volt/amp selector switch to match the voltage rating of the battery to be charged.
Clean the battery terminals. Be careful to keep
corrosion from getting in or around your eyes.
If you have a battery with removable cell caps, if
required, add distilled water to each cell until the battery acid reaches the level indicated by the manu­facturer. This will help purge excessive gases from the cells. Be careful not to overfill. If you have a sealed battery without cell caps, no action is neces­sary. Continue to the next step listed below.
Take time to read all battery manufacturer’s specific
precautions, such as removing or not removing cell caps while charging, and recommended rates of charge.
•Wear safety glasses. See additional "Personal Safety
Precautions" on page 2.
Be sure that the area around the battery is well
ventilated while it is being charged. If ventilation is poor, gas can be manually blown away by using a piece of cardboard or other non-metallic material as a fan.
If it is necessary to remove the battery from the
vehicle to charge it, always remove the grounded terminal from the battery first. A spark may be caused if all accessories in the vehicle are not completely turned off.
NOTE: A marine battery installed in a boat must be removed and charged on shore.
Sch 517
7
Page 9
Using Your Battery Charger
To obtain the best results from your battery charger, you must know how to use it properly. This section will tell you how to set the controls, and how you can charge a battery while it is still in the vehicle, or you can remove it and then charge it. Follow the instructions below depending on how you choose to charge your battery.
Setting the controls
All the controls for your charger are located on the front of the unit. Follow these instructions to obtain the accurate charge level for your battery.
VOLT/AMP SELECTOR:
The volt/amp selector switch allows you to select an amp charge rate and battery voltage type to match your charging needs. Read the following operating instructions for making the proper settings for charging a battery and using the engine start feature.
TIMER:
The timer is designed to allow your battery to be charged for a designated amount of time. To accu­rately charge your battery, you must know the size of the battery in ampere hours or reserve capacity in minutes, as well as the state of charge. Since this information is often not known, the timer limit is set at
2.25 hours. This will help prevent the battery from
overcharging to a point where it can be damaged. If you do not know the charge state of your battery, it is best to start out with the timer set at one hour or less.
HOLD feature:
This position overrides the timer, allowing the charger to continue charging for over 2.25 hours. This feature is most often used when the charging rate is 2 or 15 amps. Using this feature requires you to monitor the charging and to stop the charger when the battery is fully charged. Otherwise, charger will not stop and may cause damage to your battery.
AMMETER:
The ammeter indicates the measured amount of amperes being drawn by the battery. When you first start charging a battery, the reading will be high, with the needle around 50 or “START” when the selector is in the 50 amp charge position. As the battery becomes charged, the reading will decrease to 15 or 20 amps at full charge. This will be your indicator to stop charging. With the selector switch set to the 15 amp position, the meter should display 15 amps for a discharged battery and 7-8 amps when the battery is fully charged.
If you are using the 2 amp charge rate, you may see little or no activity by the needle.
Sch 517
8
Page 10
The “START” area of the ammeter indicates a high rate of current being drawn by the battery. For example, when cranking an engine, the needle will be at the far right side of the “START” area since the starter will be drawing up to 225 amps from the charger.
VOLTMETER:
To obtain an accurate reading of your battery’s voltage before you charge, use the voltmeter as follows:
1. Set the timer to the OFF position, put the voltage selector switch at 12 or 6 VOLT according to the battery you are testing, and then connect the charger as indicated in “Charging your battery in the vehicle” on page 10. Charger does not have to be plugged into an outlet.
2. If a battery has recently been charged or in a vehicle that has been run recently, you may want to turn your headlights on for a few minutes before you read the meter so as not to get a false reading from a surface charge. Then shut lights off, read the meter, and follow the convenient color coding.
ALTERNATOR/GENERATOR TEST
1. Set the volt/amp selector switch to the OFF position.
2. Set the battery test switch to 6 or 12 volts.
3. Set the timer switch to the OFF position.
4. With the charger off, and the clamps properly hooked
up to the battery, start the engine and while it is at a fast idle, read the charging system meter. The battery should be in a good state of charge before doing this test.
5. The volt meter is divided into three color zones: A. Green and Lighter Green – Charging system
is good.
B. Yellow – Alternator output is low. C. Red – Charging system is bad.
NOTE: If meter needle points to Red or Yellow, the
charging system may have loose fan belts, defective voltage regulator or alternator. Additional tests may be required to find the exact cause. Take the vehicle to a qualified service center.
BATTERY TEST
This test is based on the terminal voltage of the battery. If the battery is installed in the vehicle, make sure the engine and all accessories are turned off.
1. Set the volt/amp selector switch to the OFF position.
2. Set the battery test switch to 6 VOLT for 6 volt
batteries or 12 VOLT for 12 volt batteries.
3. Set the timer switch to the OFF position.
4. Read lower 6 VOLT BATTERY section of meter for
6 volt batteries and read upper 12 VOLT BATTERY section for 12 volt batteries.
Sch 517
5. Both 6 volt and 12 volt battery sections are divided into three color zones:
A. Green - Good battery. B. Yellow - Weak battery. C. Red - Bad battery.
NOTE: If the meter needle is in the Red or Yellow
area, the battery may only need charging. If, after charging, the needle still indicates in the Red or Yellow area, have the battery tested by a qualified technician.
The meter needle may point to the Lighter Green section of the meter if this test is done on a recently charged battery or a battery from a vehicle that has been run recently.
9
Page 11
Charging your battery
Charging your battery in the vehicle:
1. Arrange the power cord and charging cords care­fully in order to avoid damage that could be caused by the hood, door, or moving engine parts.
2. Keep clear of the fan blades, belts, pulleys, and other parts that can cause injury.
3. Check the polarity of the battery posts using the identification marks on the battery case: POSITIVE (POS,P, +) and NEGATIVE (NEG,N, –).
4. Identify which post of the battery is ground or connected to the chassis. THE NEGATIVE POST
IS NORMALLY THE ONE THAT IS GROUNDED.
5. To charge a negative grounded post system:
Connect the red (POSITIVE) battery charger clamp to the ungrounded POSITIVE (POS,P,+) post of the battery. Then connect the black (NEGATIVE) clamp to a heavy metal part of the chassis or engine block, away from the battery. Do not connect clamp to carburetor, fuel lines, or sheet metal parts.
To charge a positive grounded post system:
Connect the black (NEGATIVE) battery charger clamp to the NEGATIVE (NEG,N,–) ungrounded post of the battery. Then connect the red (POSI­TIVE) clamp to a heavy unpainted metal part of the chassis or engine block. Do not connect clamp to carburetor, fuel lines, or sheet metal parts.
6. Connect the clamp to the battery post and twist or rock back and forth to make a solid connection. This will help keep the clamps from slipping off the posts and causing sparks.
7. Set VOLT/AMP SELECTOR switch and TIMER to the OFF position. Next plug the power cord into a grounded AC outlet.
8. Set the TIMER to the desired charge time, from 30­135 minutes. If more than 135 minutes of charging time is needed the HOLD position can be used. When using the HOLD feature the battery being charged must be monitored closely to avoid over charging.
9. Set the VOLT/AMP SELECTOR to the desired charge position. (See “CHARGE RATE” chart on page 12 for correct settings.)
10. When battery is fully charged, the ammeter pointer will be in the farthest left position and the voltmeter pointer will be in the green area of the meter.
11. When the battery is fully charged, turn timer knob to OFF position, then unplug the charger power cord. Stand away from battery and remove the charger clamps from the NEGATIVE end of the cable first, then from the POSITIVE post.
12. Clean and store the battery charger in a dry location.
NEGATIVE GROUNDED SYSTEM
Sch 517
10
Page 12
Charging your battery outside the vehicle:
1. Remove battery from vehicle, making sure to dis­connect grounded terminal first with all power turned off to the vehicle.
REMEMBER: A marine battery should be removed and charged on shore unless special equipment designed for marine use is available. Hydrogen gas emissions can create an explosion if battery is charged on board your boat.
2. Check the polarity of the battery posts as indicated on the battery case: POSITIVE (POS,P,+) and NEGATIVE (NEG,N,–).
NOTE: On top-post batteries, the positive battery terminal usually has a larger diameter than the negative one.
3. Connect the red (POSITIVE) charger clamp to the POSITIVE post of the battery. Be sure to rock the clip back and forth to make a solid connection.
4. Attach a 6-gauge (AWG) or a 4-gauge (SAE) insu­lated battery cable of at least 24-inches in length to the NEGATIVE battery post. This cable will provide a safer connection because any arcing and sparking will not occur directly over the battery. (The battery cable is not provided with the charger, but may be purchased at most automotive accessory outlets.)
5. Take the other end of the 6-gauge (AWG) or a 4-gauge (SAE) insulated 24-inch cable and, standing as far away from the battery as possible, connect the black (NEGATIVE) charger clamp to the free end of the cable. Be sure to rock the clamp back and forth to make a solid connection.
IMPORTANT: Wear safety glasses and face away from battery while you are making the final connection.
6. Set the VOLT/AMP SELECTOR switch and TIMER to the OFF position. Next plug the power cord into a grounded AC outlet.
7. Set the TIMER to the desired charge time, from 30­135 minutes. If more than 135 minutes of charging time is needed the hold position can be used. When using the HOLD feature the battery being charged must be monitored closely to avoid over charging.
8. Set the VOLT/AMP SELECTOR to the desired charge position. (See “CHARGE RATE” chart on page 12 for correct settings.)
9. When battery is fully charged, the ammeter pointer will be in the farthest left position and the voltmeter pointer will be in the green area of the meter.
10. When the battery is fully charged, turn timer knob to the OFF position, then unplug the charger power cord. Stand away from battery and remove the charger clamps from the NEGATIVE end of the cable first, then from the POSITIVE post.
11. Clean and store the battery charger.
Sch 517
11
Page 13
Calculating charge time
The Chart Method
Use the following table to more accurately determine the time it will take to bring a battery to full charge. First, identify where your battery fits into the chart.
• Small batteries — motorcycles, garden tractors, etc.
— are usually rated in Ampere Hours (AH). For example; 6 to 12 AH, or 12 to 32 AH.
• Batteries in cars and smaller trucks are usually rated
in Reserve Capacity (RC), Cold-Cranking Amps (CCA), or both.
• Marine, or deep-cycle batteries are usually rated in
Reserve Capacity (RC).
NR means that the charger setting is NOT
RECOMMENDED. Find your battery’s rating on the following chart and note the charge time given for each charger setting. The times given are for batteries with a 50-percent charge prior to recharging. Add more time for severly discharged batteries.
BATTERY SIZE/RATING
SMALL BATTERIES
CAR/TRUCKS
MARINE/DEEP CYCLE
Motorcycle, garden tractor, etc.
200 - 315 CCA 315 - 550 CCA 550 - 1000 CCA
6-12AH 12 - 32 AH 40 - 60 RC 60 - 85 RC 85 -190 RC
80 RC 140 RC 160 RC 180 RC
The Hydrometer or Electronic Method
To find the time needed to fully charge your battery, determine the battery’s charge level with a hydrometer or electronic Percent-of-Charge Tester. The following table will help you convert hydrometer readings to percent of charge values.
SPECIFIC PERCENT PERCENT OF
GRAVITY OF CHARGE CHARGE NEEDED
1.265 100% 0%
1.225 75% 25%
1.155 25% 75%
1.120 0% 100%
When you know the percent of charge and the Amp Hour (AH) rating of your battery, you can calculate the approximate time needed to bring your battery to a full charge.
To convert Reserve Capacity to Amp Hours, divide Reserve Capacity by 2, and add 16:
Amp Hours = Reserve Capacity + 16
2
CHARGE RATE/CHARGING TIME - HOURS
2 AMP
2 - 4
4 - 10 11 - 14 14 - 18 18 - 35
18 27 30 33
To calculate time needed for a charge:
Find the percent of charge needed. (A battery at 50 percent charge that will be charged to 100 percent needs another 50 percent (.50).
Multiply the Amp Hour rating by the charge needed (.50) and divide by the charger setting (2, 20 or 60 amps).
Multiply the result by 1.25 and you’ll have the time needed, in hours, to bring the battery to full charge.
Add one additional hour for a deep-cycle battery.
Example:
Amp Hour Rating x % of charge needed x 1.25 = hours
100 (AH Rating) x .50 (charge needed) x 1.25 = 4.1625
15 (Charger Setting) hours
100 x .50 = 2.5 x 1.25 = 3.125 15
You would need to charge your 100-Ampere Hour Bat­tery for a little more than 4 hours at the 15-Amp charge rate using the above example.
15 AMP
NR
NR 1½ - 2 2 - 2½
2½ - 4½
4
Charger Setting of
50 AMP
NR
NR
1
/2 - 5/8
5
/8 - ¾
¾ - 1½
NR NR NR NR
charge
needed
Sch 517
12
Page 14
Using the engine start feature
Your battery charger can be used to jump start your car if the battery is low. Follow these instructions on how to use the engine start feature.
1. Set the timer knob to the OFF position. Then follow the instructions for how to connect the charger to the battery in the section “Charging your battery while it is in the vehicle” on page 10.
2. Plug in the charger and set the timer to the HOLD position.
3. Set the volt/amp selector switch to the engine start position for a 12 volt battery and the charger at the 225 amp rating. For a 6 volt battery, set the charger at the 125 amp rating, and then crank the engine. Crank the engine for no more than three seconds and if it does not start, wait four minutes before cranking again. During extremely cold weather, or if the battery is severely exhausted, charge the battery for about five minutes before cranking the engine.
4. If the engine does not start, charge the battery for five more minutes in the 50 amp position, before cranking it again for three seconds.
5. After the engine starts, unplug charger power cord from the outlet. Then, move the volt/amp selector switch to OFF before disconnecting the DC clamps.
IMPORTANT: Do not try to start the engine without a battery in it. You could cause damage to the electrical system.
there is not a problem with the starting system, there is a problem somewhere else with the vehicle. STOP cranking the engine until the other problem has been diagnosed and corrected.
If the engine does turn over, but never starts up,
Maintenance and Care
A minimal amount of care can keep your battery charger working properly for years.
1. Clean the clamps each time you are finished charg­ing. Wipe off any battery fluid that may have come in contact with the clamps to prevent corrosion.
2. Coil the input and output cords neatly when storing the charger. The cords can be wrapped over the handle of the charger. This will prevent accidental damage to the cords and charger.
3. Occasional cleaning of the case of the charger with a soft cloth will keep the finish shiny and help prevent corrosion.
Sch 517
13
Page 15
Troubleshooting
Performance problems often result from little things that you can fix yourself. Please read through this chart for a possible solution if a problem occurs.
PROBLEM
No reading on the ammeter.
No reading on ammeter, charger fan not working.
No reading on test meter.
Test meter pointer always to the right­hand side of meter.
Circuit breaker in
charger cycles on and off with a clicking sound.
POSSIBLE CAUSE
Clamps are not making a good connection.
2 amp charge rate is being used.
AC cord and/or extension cord is loose. Poor electrical connection.
Battery severely discharged.
Test switch may be in the wrong switch position.
Battery severely discharged.
Test meter may be in the wrong switch position.
Shorted battery clamps.
Shorted battery.
Charger leads reversed.
Volt/Amp Selector Switch set to the START position.
SOLUTION/REASONS
Check for poor connection at battery. Make sure clamps and posts are clean. Battery may not want to accept a charge due to excessive run down state.
Ammeter may show no activity at 2 amp setting.
Check AC outlet and extension cords for loose fitting plug. Check for open fuse or circuit breaker supplying AC outlet.
Continue to charge battery for another two hours. If problem continues, consult a Sears technician. Check if test switch is in proper 6 or 12 volt position.
Continue to charge battery for another two hours. If problem continues, consult a Sears technician.
Check if test switch is in proper 6 or 12 volt position.
Circuit breaker cycles when current draw is too high.
Separate the clamps. Check for worn cables and replace if needed.
Have a Sears technician test the battery.
Correct connections.
Correct Volt/Amp Selector setting.
Short start cycle when cranking engine.
Ammeter reads less than selected charge rate when charging a discharged battery.
Charger makes a loud buzz or hum.
If the above solutions do not eliminate the problem...
Drawing more than 225 amps for a period equal to or less than 5 seconds.
Failure to wait for 4 minutes (240 seconds) between cranks.
Extension cord too long or wire gauge is too small.
Weak cell or a sulfated plate.
The battery is only partially discharged.
Transformer laminations
vibrate (buzz).
Shorted diode (hum).
Crank time varies with the amount of current drawn. If cranking draws more than 225 amps, crank time may be less than 5 seconds.
Wait 4 minutes before next crank.
Use shorter or heavier gauge extension cord.
Sulfated battery will take normal charge after a period of time. If battery will not take a charge, have a Sears technician test the battery.
Contiue to change battery.
Continue charging. Buzz is not abnormal.
Have charger tested by qualified technician.
call toll-free from anywhere in the U.S.A.
1-800-SEARS-64
(1-800-732-7764)
7 am to 4:30 pm CST Monday through Friday
Sch 517
14
Page 16
OWNER’S
MANUAL
Model No.
200.71450
50/15/2 AMP
MANUAL BATTERY
CHARGER
ENGINE STARTER with
BATTERY TESTER
For information about troubleshooting
Call toll-free from anywhere in the U.S.A. 7 am to 4:30 pm CST Monday through Friday
1-800-SEARS-64
(1-800-732-7764)
For the repair or replacement parts you need
Call 7 am - 7 pm, 7 days a week
When requesting service or ordering parts, always provide the following information:
Product Type
Model Number
Part Number
Part Description
1-800-366-PART
(1-800-366-7278)
For the location of a Sears Repair Service Center in your area
Call 24 hours a day, 7 days a week
1-800-488-1222
REPAIR SERVICES
America's Repair Specialists
0000000517-900
Loading...