SeaLand VACUFLUSH User Manual

0 (0)
SeaLand VACUFLUSH User Manual

VACUFLUSH® STATUS PANEL

PRODUCT GUIDE

Dometic Corporation • Sanitation Systems

13128 State Rt. 226, P.O. Box 38

Big Prairie, OH 44611-0038 USA

SeaLand Product Hotline 1-800-321-9886

(8:00 a.m. - 5:00 p.m. ET)

1

TABLE OF CONTENTS

Safety Instructions

2

Dimensional Specifications

4

Electrical Specifications

2

Parts List

4

Product Features

2

Control Panel Mounting Template

5

Installation Instructions

3

Wiring Diagrams

5, 7

How to Use

3

Warranty Information

8

SAFETY INSTRUCTIONS

WARNING: When using this device, always exercise basic safety precautions including the following:

Read all instructions before use or installation.

Never connect this device to any electrical circuit with other than 12, 24 or 32 volt Direct Current or exceed the amperage draw specified below.

Never install, use or service any component of this device in an atmosphere with potentially flammable or explosive vapors.

SPECIFICATIONS

Product Name:

VacuFlush Status Panel

Shipping Information:

Carton Size: 6 in x 6 in x 4 in (15.2 cm x 15.2 cm x 10.2 cm)

Electrical:

Current and Wattage per Indicator Light

 

 

12 VDC

24 VDC

32 VDC

 

Amps

.012

– .016

.012

– .016

.020

– .024

 

Watts

.15

– .22

.29

– .45

.64

– .86

Magnetic, manual reset circuit breaker

 

 

 

 

 

 

 

 

 

 

 

 

SIZE

F.L. AMPS

TRIP AMPS

MAX VDC

 

5 Amp

 

5

6.75

 

32

 

10 Amp

 

10

13.5

 

32

Maximum wire size per terminal block pin = 12 gauge

PRODUCT FEATURES:

Continuously monitors status of vacuum for proper operation.

Magnetic circuit breaker designed to protect the vacuum pump from damage.

Allows the boater to shut the system down during the night.

Deluxe panel complements bathroom decor.

Indicates loss of electrical power or system power off.

2

INSTALLATION INSTRUCTIONS

1.Select a mounting location away from direct contact with water and oil. Dry locations in the head, salon or galley are most desirable.

2.Confirm clearances for the panel behind walls and bulkheads.

3.Cut out mounting hole for control panel. (See template on page 5 for cut out and hole locations)

4.Do not mount panel housing until wiring is routed and secured.

5.Route wires using the wiring diagram on pages 5 & 7.

6.Mount panel housing with the (4) #6 x 1" long black oval head screws provided.

7.Insert the (2) small tabs on the left side of the face plate into the housing and snap the large tab on the right side of the face plate into the housing to secure it.

HOW TO USE THE VACUFLUSH STATUS PANEL

Under normal operating conditions the red lamp will light after each flush until the pump recharges the vacuum to proper operating level then the green lamp will light.

If there is constant green light to red light cycling between flushes it may indicate a leak in the vacuum system. The vacuum pump will normally operate automatically every so often to recharge the vacuum,.

A continuous red light indicates an extended loss in vacuum as a result of a blockage, pump failure or massive vacuum leak. TURN OFF THE SYSTEM AND REPAIR AS SOON AS POSSIBLE.

If the red light seems to stay on longer than when the system was originally installed, it is probably time to replace the duckbill valves in the vacuum pump.

If there is no vacuum in the toilet and the green light is on, a blockage has probably occurred between the toilet bowl and the vacuum tank.

If there is no vacuum present in the toilet after several minutes, it may indicate a blockage at the outlet of the vacuum tank or inlet of the vacuum pump.

3