SeaLand TANKWATCH User Manual

TANKWATCH
LEVEL MONITOR SYSTEM
OWNER’S MANUAL
®
4
Dometic Corporation • Sanitation Systems
Big Prairie, OH 44611
SeaLand Product Customer Service: 1-800-321-9886
(8:00 a.m. - 5:00 p.m. ET)
1

TABLE OF CONTENTS

Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . 2
Product Features . . . . . . . . . . . . . . . . . . . . . . . . 2
Models and Accessories . . . . . . . . . . . . . . . . . . .2
Dimensional Specifications . . . . . . . . . . . . . . . . .3
Product Specifications . . . . . . . . . . . . . . . . . . . . . 3
Installation Instructions . . . . . . . . . . . . . . . . . 4 - 5
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . .6
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Manufacturer’s One-Year Limited Warranty . . . . . 8
Control Panel Mounting Template

SAFETY INSTRUCTIONS

WARNING: When using this device, always exercise basic safety precautions, including the following:
Read all instructions before installation or use.
Never connect this device to any electrical circuit with other than 12 or 24 volt Direct Current or exceed
the amperage draw listed below.
Never install the indicator panel in an atmosphere with potentially flammable or explosive vapors.
Never install the probe cap with float switches into a tank that contains anything other than fresh, gray or
black water.
CAUTION: Dropping or rough handling of float switches may result in damage.

PRODUCT FEATURES

Eliminates false reading from fouled probes.
Three float switches, four level indications for all tanks up to 22-inch (559mm) & 45-inch (114cm) in depth.
Deluxe panel complements bathroom decor and provides international symbology.
Installs in any rigid tank with optional 3-inch NPT mounting flange.
One model operates on 12 or 24 VDC.
Probe cap provides clean out for easy access to interior of tank.
Cap is available with or without 5/8" vent hose connection.
Optional shut-off relay plugs into back of circuit board to shut down toilet or water system when gray or
black water tank is full or when freshwater tank is empty.
Always one level light on to confirm that electrical power is applied.
Only one level light on at a time to eliminate confusion and save battery power.
CE and IMCI approved for electromagnetic compatibility.
The TankWatch 4 Level Monitor System is designed to permit remote sensing of liquid levels in wastewater, gray water or potable fresh water tanks. The TankWatch 4 utilizes three micro-float switches, which activate a four­light panel. One is fixed and activates a full light when the liquid is within approximately 2-inches of the top inside surface of the tank. The other two float switches are mounted on adjustable stems and can be positioned to within 2-inches of the bottom of the tank. The stems are semi-flexible and are designed to flex with the sloshing of the tank contents. A simple procedure allows one adjustable stem to sense when the tank is empty and the other adjustable stem to sense when the tank is 1/4 or 1/2 full, depending on the application.

MODELS AND ACCESSORIES

Part Number Description
313600113 313600114 313600115 313600116 307230272 600341292 600342490 385318714 360600212 360600224
TankWatch® 4 Panel and Cap with Vent, 22-inch Probes TankWatch® 4 Panel and Cap without Vent, 22-inch Probes TankWatch® 4 Panel and Cap with Vent, 45-inch Probes TankWatch® 4 Panel and Cap without Vent, 45-inch Probes Universal Flange (3-inch NPT) with gasket and stainless steel hardware Plug In Relay, 12VDC Plug In Relay, 24VDC “Do Not Flush” Panel TankWatch® 4 Panel with 12VDC Relay TankWatch® 4 Panel with 24VDC Relay
2

PRODUCT SPECIFICATIONS

Product Name: TankWatch® 4 Level Monitor System
Electrical:
12 Volts DC @ .017 amps (without optional relay) and .152 amps (with optional relay) 24 Volts DC @ .014 amps (without optional relay) and .072 amps (with optional relay) Float Switch Rating = 20 watts with resistive load 12-pin terminal block allows up to one 12-gauge wire per position
Maximum Tank Pressure: 25 PSI
Materials:
Float . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Buna N
Tank Mounted Float Switch Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PVC
Float Switch Body . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ABS
O-Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nitrile
Adjustable Stems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cross Linked Polypropylene
Compression Nut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glass Reinforced Polypropylene
Control Panel Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polypropylene
Face Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polycarbonate
Electrical and dimensional specifications subject to change without notice.

DIMENSIONAL SPECIFICATIONS

*
4 3/4"
[121mm]
* Max length for 45-inch probes is 43 3/4-in. (1111mm).