711-M28
MARINE TRAVELER® TOILET
OWNER’S MANUAL
Dometic Corporation
13128 State Rt 226, PO Box 38, Big Prairie, Ohio 44611-0038 U.S.A.
SeaLand Product Hotline 1-800-321-9886
(8:00 a.m. - 5:00 p.m. ET)
1
TABLE OF CONTENTS
RECOMMENDATIONS
Specifications . . . . . . . . . . . . . . . . . . . . . . . . 2
Recommendations . . . . . . . . . . . . . . . . . . . . 2
Installation Instructions . . . . . . . . . . . . . 2 - 4
Operating Instructions . . . . . . . . . . . . . . . . . 4
Maintenance . . . . . . . . . . . . . . . . . . . . . . 4 - 5
Preparing for Summer Use . . . . . . . . . . . . . 5
Model Identification . . . . . . . . . . . . . . . . . . . 5
Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . 5
Customer Service . . . . . . . . . . . . . . . . . . . . 5
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Troubleshooting Guide . . . . . . . . . . . . . . . . 7
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SPECIFICATIONS
Product Name: 711-M28 Marine Traveler Toilet
Shipping Information:
Carton Sizes:
Toilet 21" x 18-1/2" x 13-1/2"
(533mm x 470mm x 343mm)
Tank 19-1/4" x 17-1/2" x 11-1/2"
(489mm x 445mm x 292mm)
Weight Approx. 49 lbs. (22Kg)
System:
Average water consumption per flush 1 Qt. (.95 L)
Minimum water consumption per flush 1 Pt. (.47L)
Holding tank capacity . . . . . . . . . . . 9.5 Gal. (36L)
Fresh water supply pressure . . . . . . . . . . 5-80 PSI
Water inlet size . . . . . . . . . . . . . . . . . . . 1/2" NPT
Holding tank discharge fitting . . . . . . . 1-1/2" NPT
Vent fitting . . . . . . . . . . . . . . . . . . . . . . 5/8" Barb
Unit Weight . . . . . . . . . . . . . . . . . 41 Lbs. (19Kg)
1. Read the “Operating Instructions” section of the
manual carefully.
2. Make sure all guests understand the operation of
the Traveler toilet.
3. Carry a few spare parts for the maintenance purposes.
SeaLand has developed several repair kits that will
save you both time and expense should a problem
occur. See “Customer Service” section of this manual.
®
4. Use only SeaLand brand
Tissue and Secure
liquid or SeaLand® brand Holding Tank Deodorants
to maintain a trouble-free system.
5. Do not use chlorine or caustic chemicals, such as
laundry bleach or drain opening types, in the
system. These products damage the seals in toilets.
6. Do not flush foreign objects through the toilet.
7. Do not allow small problems to go unsolved. As soon
as a problem is detected, correct it.
INSTALLATION INSTRUCTIONS
Tank:
1. Select position in bathroom where unit can operate
properly. Allow room for using the flush lever and
clearance for raising the seat and lid.
2. Position the tank 3/4" (19mm) away from the wall.
Mark four holes at mounts on tank base. After holes
are marked, remove tank, and drill pilot holes. Slide
tank back into position. Secure the tank with four
#14 x 2" long pan head screws and washers on all
tank mounts.
®
Dimensions:
3. Run 5/8" (16mm) I.D. hose to vent fitting and secure
with hose clamps.
Install thru-hull vent fitting:
(not supplied with unit – SeaLand part number 346368)
4. Drill hole through the hull, well above water line and
directly above Traveler toilet. Hole location is determined by routing and length of hose.
2
INSTALLATION INSTRUCTIONS (cont’d)
5. Apply waterproof caulk around underside of thru-hull
vent fitting.
6. Install thru-hull vent fitting and secure snugly with nut.
Wipe off excess caulk with damp cloth.
7. Attach remaining end of vent hose to thru-hull
fitting with hose clamp.
Dockside Discharge Fitting:
(not supplied by SeaLand)
8. Drill hole in deck directly above Traveler toilet. Hole
location is determined by routing space and length of
hose.
9. Screw 1-1/2" FPT x 1-1/2" hose barb into bottom of
deck fitting.
12. Route hose from tank to deck fitting and secure with
hose clamp.
Note: The holding tank on the 711-M28 is designed
to withstand discharge by a properly operating
discharge pump.
Toilet Installation:
13. Push button on back of flush pedal, then pull flush
pedal cover away from pedal to expose water valve.
Remove plastic pedestal cover from toilet base.
14. Install the (4) 1/4-20 x 1-3/4" long studs in inserts on
the tank top.
10. Apply waterproof caulk around deck hole and install
deck fitting into 2-1/4" (57mm) hole with screws. Wipe
off excess caulk with a damp cloth.
11. Install 1-1/2" MPT x HUB adapter into discharge fitting on holding tank.If necessary, PVC cement elbow and hose adapter or hose adapter only into
1-1/2" (38mm) adapter. Secure 1-1/2" (38mm) hose
to adapter with hose clamp.
or
15. Place floor flange seal on studs, aligning the studs
with bumps on seat. Note: “THIS SIDE UP” should
face upwards.
16. Place toilet on studs and secure with four washers
and four nuts.
3