Seagate ST3500071FC, ST3400071FC User Manual

Page 1
Product Manual
NL35 Series FC
ST3500071FC ST3400071FC
100343673 Rev . D August 2007
Page 2
©2007, Seagate Technology LLC All rights reserved.
August 2007
Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. NL35 Series, SeaTools and SeaTDD are either trademarks or registered trademarks of Seagate Technology LLC or one of its affiliated companies in the United States and/or other countries. All other trademarks or registered trademarks are the property of their respective owners.
One gigabyte, or GB, equals one billion bytes when referring to hard drive capacity. Accessible capacity may vary depending on operating environment and formatting. Quantitative usage examples for various applications are for illustrative purposes. Actual quantities will vary based on various factors, including file size, file format, features and application software. Seagate reserves the right to change, without notice, product offerings or specifications.
Page 3
NL35 Series FC Product Manual, Rev. D
iii
Contents
1.0 Scope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.0 Applicable standards and reference documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1.1 Electromagnetic compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1.2 Electromagnetic susceptibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.2 Electromagnetic compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.3 Environmental protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.4 Reference documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.0 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Standard features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.2 Media description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.4 Reliability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.5 Formatted capacities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.5.1 Programmable drive capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.6 Factory-installed accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.7 Factory-installed options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.8 User-installed accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.0 Performance characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.1 Internal drive characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2 Seek performance characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2.1 Access time [4]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2.2 Format command execution time (in minutes). . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2.3 Generalized performance characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.3 Start/stop time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.4 Prefetch/multi-segmented cache control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.5 Cache operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.5.1 Caching write data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.5.2 Prefetch operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.5.3 Optimizing cache performance for desktop and server applications . . . . . . . . . 15
5.0 Reliability specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.1 Error rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.1.1 Recoverable Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.1.2 Unrecoverable errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.1.3 Seek errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.1.4 Interface errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.2 Reliability and service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.2.1 Mean Time Between Failure (MTBF). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.2.2 Preventive maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.2.3 Hot plugging the drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.2.4 S.M.A.R.T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.2.5 Thermal monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.2.6 Drive Self Test (DST). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.2.7 Product warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.0 Physical/electrical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.1 AC power requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.2 DC power requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.2.1 Conducted noise immunity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.2.2 Power sequencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.3 Power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Page 4
iv
NL35 Series FC Product Manual, Rev. D
6.4 Environmental limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.4.1 Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.4.2 Relative humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.4.3 Effective altitude (sea level) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
6.4.4 Shock and vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.4.5 Air cleanliness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6.4.6 Corrosive environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.4.7 Acoustics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.4.8 Electromagnetic susceptibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.5 Mechanical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7.0 Defect and error management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
7.1 Drive internal defects/errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
7.2 Drive error recovery procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
7.3 FC-AL system errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
7.4 Background Media Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
7.4.1 Media Pre-Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
8.0 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
8.1 Drive ID/option selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
8.2 Drive orientation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
8.3 Cooling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
8.4 Drive mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
8.5 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
9.0 Interface requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
9.1 FC-AL features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
9.1.1 Fibre Channel link service frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
9.1.2 Fibre Channel task management functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
9.1.3 Fibre Channel task management responses . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
9.1.4 Fibre Channel port login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
9.1.5 Fibre Channel port login accept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
9.1.6 Fibre Channel Process Login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
9.1.7 Fibre Channel Process Login Accept. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
9.1.8 Fibre Channel fabric login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
9.1.9 Fibre Channel fabric accept login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
9.1.10 Fibre Channel Arbitrated Loop options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
9.2 Dual port support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
9.3 SCSI commands supported. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
9.3.1 Inquiry data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
9.3.2 Mode Sense data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
9.4 Miscellaneous operating features and conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
9.5 FC-AL physical interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
9.5.1 Physical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
9.5.2 Connector requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
9.5.3 Electrical description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
9.5.4 Pin descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
9.5.5 FC-AL transmitters and receivers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
9.5.6 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
9.5.7 Fault LED Out. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
9.5.8 Active LED Out. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
9.5.9 Enable port bypass signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
9.5.10 Motor start controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
9.5.11 SEL_6 through SEL_0 ID lines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
9.5.12 Device control codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
9.6 Signal characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Page 5
NL35 Series FC Product Manual, Rev. D
v
9.6.1 TTL input characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
9.6.2 LED driver signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
9.6.3 Differential PECL output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
9.6.4 Differential PECL input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
10.0 Seagate Technology support services. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Page 6
vi
NL35 Series FC Product Manual, Rev. D
Page 7
NL35 Series FC Product Manual, Rev. D
vii
List of Figures
Figure 1. NL35 Series family disc drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Figure 2. DC current and power vs. input/output operations per second (1 Gbit). . . . . . . . . . . . . . . . . 27
Figure 3. DC current and power vs. input/output operations per second (2 Gbit). . . . . . . . . . . . . . . . . 27
Figure 4. Location of the HDA Temperature check point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 5. Recommended mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 6. Mounting configuration dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 7. Air flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 8. Physical interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 9. Port bypass circuit physical interconnect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 10. FC-AL SCA device connector dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 11. FC-AL transmitters and receivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 12. Transmit eye diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Figure 13. Receive eye diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Page 8
viii
NL35 Series FC Product Manual, Rev. D
Page 9
NL35 Series FC Product Manual, Rev. D
1

1.0 Scope

This manual describes Seagate Technology® LLC, NL35 Series (Fibre Channel) disc drives. NL35 Series drives support the Fibre Channel Arbitrated Loop and SCSI Fibre Channel Protocol specifications
to the extent described in this manual. The Fibre Channel Interface Manual (part number 77767496) describes the general Fibre Channel Arbitrated Loop characteristics of this and other Seagate Fibre Channel drives.
Figure 1. NL35 Series family disc drive
Page 10
2
NL35 Series FC Product Manual, Rev. D
Page 11
NL35 Series FC Product Manual, Rev. D
3

2.0 Applicable standards and reference documentation

The drive has been d evelope d as a system p eriphe ral to the hig hest st and ards of desig n and constru c tion. The drive depends upon its host equipment to provide adequate power and environment in order to achieve opti­mum performance and compliance with applicable industry and governmental regulations. Special attention must be given in the areas of safety, power distribution, shielding, audi ble noise con trol , an d tempe ratu re reg u­lation. In particular, the drive must be securely mounted in order to guarantee the specified performance char­acteristics. Mounting by bottom holes must meet the requirements of Section 8.4.

2.1 Standards

The NL35 Series family complies with Seagate standards as noted in the appropriate sections of this manual and the Seagate Fibre Channel Interface Manual, part number 77767496.
The NL35 Series disc drive is a UL recognized component per UL1950, CSA certified to CAN/CSA C22.2 No. 950-95, and VDE or TUV certified to EN60950.

2.1.1 E lect roma gn etic compatibility

The drive, as delivered, is designed for system integration and installation into a suitable enclosure prior to use. As such the drive is supplied as a subassembly and is not subject to Subpart B of Part 15 of the FCC Rules and Regulations nor the Radio Interference Regulations of the Canadian Department of Communica­tions.
The design characteristics of the drive serve to minimize radiation when installed in an enclosure that provides reasonable shield ing. As such, t he dr ive is cap able of me eting th e C lass B l imit s of the FC C Rules a nd R eg ula­tions of the Canadian Department of Communications when properly packaged. However, it is the user’s responsibility to assure that the drive meets the appropriate EMI requirements in their system. Shielded I/O cables may be required if the enclosure does not provide adequate shielding. If the I/O cables are external to the enclosure, shielded cabl es sh ould be u sed, wi th the shields gr ounde d to the enclosur e and to the host co n­troller.

2.1.2 Electromagn etic susc ept ibili ty

As a component assembly, the drive is not required to meet any susceptibility performance requirements. It is the responsibility of those integrating the drive within their systems to perform those tests required and design their system to ensure that equipment operating in the same system as the drive or external to the system does not adversely affect the performance of the drive. See Section Table 11, DC power requirements.
Page 12
4
NL35 Series FC Product Manual, Rev. D

2.2 Electroma gnetic compliance

Seagate uses an independent laboratory to confirm compliance with the directives/standards for CE Marking and C-Tick Marking. T he dr ive was tested in a r epre sent ative system for typica l applications. The select ed sys­tem represents the most popular characteristics for test platforms. The system configurations include:
• Typical current use microprocessor
• 3.5-inch floppy disc drive
• Keyboard
• Monitor/display
• Printer
• External modem
• Mouse Although the test system with th is Seag ate mo del comp lies with the dir ectives/st and ards, we cannot gu aran tee
that all systems will comply. The computer manufacturer or system integrator shall confirm EMC compliance and provide the appropriate marking for their product.
Electromagnetic compliance for the European Union
If this model has the CE Marking it complies with the European Union requirements of the Electromagnetic Compatibility Directive 89/336/EEC of 03 May 1989 as amended by Directive 92/31/EEC of 28 April 1992 and Directive 93/68/EEC of 22 July 1993.
Australian C-Tick
If this model has the C-Tick Marking it complies with the Australia/New Zealand Standard AS/NZS3548 1995 and meets the Electromagnetic Compatibility (EMC) Framework requirements of Australia’s Spectrum Man­agement Agency (SMA).
Korean MIC
If this model has the Korean Min ist ry of Infor mat ion and Com munication (MIC) logo, it complie s with par agr aph 1 of Article 11 of the Electromagnetic Compatibility (EMC) Control Regulation and meets the Electromagnetic Compatibility Framework requirements of the Radio Research Laboratory (RRL) Ministry of Information and Communication Republic of Korea.
Taiwanese BSMI
If this model has the Chin ese N ation al Standard (CNS) 13438 marking, it co mplies w ith Chi n ese Nationa l Stan­dard (CNS) 13438 and meets the Electromagnetic Compatibility (EMC) Framework requirements of the Tai­wanese Bureau of Standards, Metrology, and Inspection (BSMI).

2.3 Environmental protection

Seagate designs its products to meet environmental protection requirements worldwide, including regulations restricting certain chemica l subst ances .
European Union Restriction of Hazardous Substances (RoHS)
A new law, the European Union Restriction of Hazardous Substances (RoHS) directive, will restrict the pres­ence of chemical substances, including Lead (Pb), in electronic products effective July 2006. The directive’s requirements have not been finalized. This drive is manufactured with components and materials that are expected to comply with the RoHS directive when the directive takes effect.
Page 13
NL35 Series FC Product Manual, Rev. D
5

2.4 Reference documents

NL35 Series FC Installation Guide Seagate part number: 100343674 Fibre Channel Interface Manual Seagate part number: 77767496 ANSI Fibre Channel Documents X3.230-1994 FC Physical and Signaling Interface (FC-PH)
X3.297.1997 FC-PH-2 Fibre Channel Physical and Signaling Interface-2 X3.303.1998 FC-PH-3 Fibre Channel Physical and Signaling Interface-3 X3.272-1996 FC Arbitrated Loop (FC-AL) X3.269-1996 Fibre Channel Protocol for SCSI (FCP) NCITS TR-19 Private Loop SCSI Direct Attach (PLDA) NCITS TR-20 Fabric Loop Attachment (FC-FLA) SFF-8045 Specification for 40-pin SCA-2 Connector with Parallel Selection SFF-8067 Specification for 40-pin SCA-2 Connector with
Bidirectional Enclosure Services Interface
ANSI Small Computer System Interface (SCSI) Documents X3.131-1994 (SCSI-2) X3.270-1996 (SCSI-3) Architecture Model NCITS 305-199X (SCSI-3) Enclosure Services
Specification for Acoustic Test Requirement and Procedures Seagate part number: 30553-001
Package Test Specification Seagate P/N 30190-001 (under 100 lb.) Package Test Specification Seagate P/N 30191-001 (over 100 lb.)
In case of conflict between this document and any referenced document, this document takes precedence.
Page 14
6
NL35 Series FC Product Manual, Rev. D
Page 15
NL35 Series FC Product Manual, Rev. D
7

3.0 General description

NL35 Series drives combine Tunneling Magnetoresistive (TMR) heads and a Fibre Channel interface to pro­vide high performance, high capacity data storage for a variety of systems including engineering workstations, network servers, mainframes, and supercomputers.
NL35 Series drives support the Fibre Channel Arbitrated Loop (FC-AL) and SCSI Fibre Channel Protocol as described in the ANSI specifications, this document, and the Fibre Channel Interface Manual (part number
77767496) which describes the general interface characteristics of this drive. NL35 Series drives are classified as intelligent peripherals and provide level 2 conformance (highest level) with the ANSI SCSI standard.
Never disassemble the HDA and do not attempt to service items in the sealed enclosure (heads, media, actu­ator, etc.) as this requires special facilities. The drive contains no parts replaceable by the user and opening the HDA for any reason voids your warranty.
NL35 Series drives use a dedi ca ted lan ding zon e at th e i nnermost r adi us o f the m edia to eli minat e the p ossibil ­ity of destroying or degrading data by landing in the data zone. The drive automatically goes to the landing zone when power is removed.
An automatic shipping lock prevents potential damage to the heads and discs that results from movement dur­ing shipping and handling. The shipping lock automatically disengages when power is applied to the drive and the head load process begins.
A high-performance actuator assembly with a low-inertia, balanced, patented, straight arm design provides excellent performance with minimal power dissipation.
Page 16
8
NL35 Series FC Product Manual, Rev. D

3.1 Standard featu re s

NL35 Series drives have the following standard features:
• Integrated dual port FC-AL controller
• Concurrent dual port transfers
• Support for FC arbitrated loop, private and public attachment
• Differential copper FC drivers and receivers
• Downloadable firmware using the FC-AL interface
• Supports SCSI enclosure services via interface connector
• 64-deep task set (queue)
• Supports up to 32 initiators
• Drive selection ID and configuration options are set on the FC -AL ba ckpanel or th roug h inter face co mma nds. Jumpers are not used on the drive.
• Fibre Channel worldwide name uniquely identifies the drive and each port
• User-selectable logical block size (512, 520, 524 or 528 bytes per logical block)
• Selectable frame sizes from 256 to 2,112 bytes
• Industry standard 3.5-inch low profile form factor dimensions
• Programmable logical block reallocation scheme
• Flawed logical block reallocation at format time
• Programmable auto write and read reallocation
• Reed-Solomon error correction code
• Sealed head and disc assembly (HDA)
• No preventive maintenance or adjustments required
• Dedicated head landing zone
• Automatic shipping lock
• Embedded Grey Code track address and servo wedge address to eliminate seek errors
• Self-diagnostics performed at power on
• 1:1 interleave
• Zone bit recording (ZBR)
• Vertical, horizontal, or top down mounting
• Dynamic spindle brake
• 8,192 Kbyte data buffer. See Section 4.5.
• Drive Self Test (DST)
• BackGround Media Scan (BGMS)
• Data Integrity Check
• Power Save
• Embedded servo design
• Reallocation of defects on command (Post Format)
• Fibre Channel interface transports SCSI protocol
Page 17
NL35 Series FC Product Manual, Rev. D
9

3.2 Media desc ription

The media used on the drive has an aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for improved durability and environmental protection.

3.3 Performance

• Programmable multi-segmentable cache buffer
• 200 Mbytes/sec maximum instantaneous data transfers per port
• 7K RPM spindle; average latency = 4.17 msec
• Command queuing of up to 64 commands
• Background processing of queue
• Supports start and stop commands

3.4 Reliability

• 1,000,000 hours MTBF (Mean Time Between Failures)
• LSI circuitry
• Balanced low mass rotary voice coil actuator
• Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T.)
• Dithering

3.5 Formatted ca pacities

St an dard OEM mo del s ar e formatte d to 512 bytes per block. The sector size is sel ect ab le at fo rma t time. Users having the necessary equipment may modify the data block size before issuing a format command and obtain different formatted capacities than those listed.
For 2 gigabit operation, sector sizes must be divisible by 8. To provide a stable target capacity environment and at the same time provide users with flexibility if they
choose, Seagate recommends product planning in one of two modes:
1. Seagate designs specify cap acity po i nt s at cert ain sect or si zes tha t Seagate gu ara ntees cur ren t and futu re products will meet. We recommend customers use this capacity in their project planning, as it ensures a stable operating point with backward and forward compatibility from generation to generation. The current guaranteed operating points for this product are:
Sector Size
2. Seagate drives also may be used at the maxi mu m available cap acity at a given secto r size, but the excess capacity above the guaranteed level will vary between 7K, 10K and 15K families and from generation to generation, depending on how each sector size actually formats out for zone frequencies and splits over servo bursts. This added capacity potential may range from 0.1 to 1.3 percent above the guaranteed capacities listed abo ve. U sing the drives in this manner give s the abso lute m aximum cap a c ity pot ential , but the user must determine if the extra capacity potential is useful, or whether their assurance of backward and forward compatibility takes precedence.
ST3500071FC ST3400071FC Decimal Hex Capacity (bytes) Decimal Hex Capacity (bytes)
512 976562500 3A352944 500,000,000,000 781250000 2E90EDD0 400,000,000,000 520 961538465 394FE9A1 500,000,001,800 769230777 2DD987B9 400,000,004,040 524 941486281 381DF0C9 493,338,811,244 752213841 2CD5DF51 394,160,052,684 528 938165665 37EB45A1 495,351,471,120 749632385 2CAE7B81 395,805,899,280
Page 18
10
NL35 Series FC Product Manual, Rev. D

3.5.1 Programmable drive capacity

Using the Mode Select command, the drive can change its capacity to something less than maximum. See the Mode Select Parameter List table in the FC Interface Product Manual. Refer to the Parameter list block descriptor number of blocks field. A value of zero in the number of blocks field indicates that the drive shall not change the capacity it is currently formatted to have. A number in the number of blocks field that is less than the maximum number of LBAs changes the total drive capacity to the value in the block descriptor number of blocks field. A value greater than the maximum number of LBAs is rounded down to the maximum capacity.

3.6 Factory -installed acce ssories

OEM standard drives are shipped with the NL35 Series FC Installation Guide (part number 100343674).

3.7 Factory-installed options

Yo u may order the following items which are incorporated at the manufacturing facility d uring production or packaged before shipping. Some of the options available are (not an exhaustive list of possible options):
• Other capacities can be ordered depending on sparing scheme and sector size requested.
• Single-unit shipping pack. The drive is normally shipped in bulk packaging to provide maximum protection against transit damage. U nit s shipped individually require add itional pro tection as pr ovided by th e singl e unit shipping pack. Users planning single unit distribution should specify this option.
• The NL35 Series FC Installation Guide, part number 100343674, is usually included with each standard OEM drive shipped, but extra copies may be ordered.
• The Safety and Regulatory Agency Specifications, part number 75789512, is usually included with each standard OEM drive shipped, but extra copies may be ordered.

3.8 User-ins talle d accessorie s

The following accessories are available. All kits may be installed in the field.
• 4 Gbit Fibre Channel Kit, part number 100364396 This kit contains an interposer board which allows the FC connector on the drive to be split into its compo­nent parts with one PS (5V, 12V) 4-pin Molex connector and 2 SFP (20-pin, 3.3V) data connectors. This alows a standard PC power supply and 2 HBA data channels to be connected directly to the drive.
• Single-unit shipping pack.
Page 19
NL35 Series FC Product Manual, Rev. D
11

4.0 Performance characteristics

This section provides detailed information concerning performance-related characteristics and features of NL35 Series drives.

4.1 Internal drive characteristics

ST3500071FC ST3400071FC
Drive capacity* 500.0 ........................ 400.0........................ ..................Gbytes (formatted, rounded off value)
Read/write data heads 8 ...............................8
Bytes per track 686...........................552........................... ..................Kbytes (average, rounded off values)
Bytes per surface 84.1 ..........................67.7.......................... ..................Mbytes (unformatted, rounded off value)
Tracks per surface (total) 122,712 .................... 122,712.................... ..................Tracks (user accessible)
Tracks per inch 120,000 .................... 120,000.................... ..................TPI
Peak bits per inch 747 ........................... 597........................... ..................KBPI
Internal data rate 411-794 ....................322-669.................... ..................Mbits/sec (variable with zone)
Disc rotation speed 7,200 . ...... ................. 7,200. ....................... ..................rpm (+ 0.5%)
Avg rotational latency 4.17 .......................... 4.17................. ......... ..................msec
* One Gbyte equals one billion bytes w hen ref erring t o hard drive capacity. Accessible capacity may vary depending on op-
erating environment and formatting.

4.2 Seek performance ch aracteristics

4.2.1 Access time [4]

Not including controller overhead (witho ut disconnect) [1]
Drive level
Read Write
msec Average—Typical [2] 8.5 9.5 Single Track—Typical [2] 0.8 1.0 Full Stroke—Typical [2] 16 16.5

4.2.2 Format command execution time (in minutes)

ST3500071FC ST3400071FC
Maximum (wi th verify) Maximum (without verify)
375 360 170 155
Page 20
12
NL35 Series FC Product Manual, Rev. D

4.2.3 Generalized performance characteristics

Minimum sector interleave 1 to 1
Data buffer transfer rate to/from disc media (one 512-byte sector):
ST3500071FC ST3400071FC
Minimum [3]* 33 35 MBytes/sec Maximum [3] 66 66 MB ytes/sec
Sustainable disc transfer rate:
ST3500071FC ST3400071FC
Minimum [3]* 32 27 MBytes/sec Maximum [3] 67 56 MB ytes/sec
Fibre Channel Interface maximum instantaneous transfer rate
1 GHz 2 GHz
106 Mbytes/sec* per port (dual port = 212 Mbytes/ sec*)
Note. 1 Megabyte (MB) = 1,000,000 bytes.
Sector Sizes
Default is 512-byte data blocks.
Logical block sizes
Default is 512-byte data blocks
512, 520, 524, and 528 supported. Read/write consecutive sectors on a track Yes Flaw reallocation performance impact (for flaws reallocated at format time
using the spare sectors per sparing zone reallocation scheme.) Overhead time for head switch in sequential mode
Overhead time for one track cylinder switch in sequential mode 0.66 msec (typical) Average rotational latency 4.17 msec
Negligible
1.56 msec
212 Mbytes/sec* per port (dual port = 424 Mbytes/sec*)
*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or
from the host.
Notes for Section 4.2.
[1] Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the
request for a Status Byte Transfer to the Initiator (excluding connect/disconnect).
[2] Typical access times are measured under nominal conditions of temperature, voltage, and horizontal ori-
entation as measured on a representative sampl e of drives. [3] Assumes system ability to support the rates listed and no cable loss. [4] Access to data = access tim e + latency time.
Page 21
NL35 Series FC Product Manual, Rev. D
13

4.3 Start/stop time

If the Motor Start option is disabled, the drive becomes ready within 25 seconds after DC power is applied. If a recoverable error conditio n i s detect ed dur ing the sta rt seq uence, the dr i ve execu tes a re cover y proce dure and the time to become ready may exceed 25 seconds. Stop time is less than 30 seconds (maximum) from removal of DC power.
If the Motor Start option is enabled, the internal controller accepts the commands listed in the Fibre Channel Interface Manual less than 3 seconds after DC power has been applied. After the Motor Start command has been received, the drive becomes ready for normal operations within 25 seconds (excluding the err or reco very procedure). The Motor Start command can also be used to command the drive to stop the spindle.
There is no power control switch on the drive.

4.4 Prefetch /m ulti-segmen te d cache contro l

The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in cache operations. To select this feature, the host sends the Mode Select command with the proper values in the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint that each is enabled and disabled independently using the Mode Select command; however, in actual opera­tion, the prefetch feature overlaps cache operation somewhat as described in sections 4.5.1 and 4.5.2.
All default cache and prefetch mode parameter values (Mode Page 08h) for standard OEM versions of this drive family are given in Table 25.

4.5 Cache operation

Note. Refer to the Fibre Ch anne l Interface Manual for more detail concerning the cache bits.
Of the 8,192 kbytes physical buf fer sp ace i n the drive, 6,9 91 kbytes ca n be used as a ca che. Th e buf fer can be divided into logical se gmen ts (using Mode Select Page 08h, byte 1 3) fr om whic h dat a is rea d and to which data is written.
The drive keeps track of the logical block addresses of the data stored in each segment of the buffer. If the cache is enabled (see RCD bit in the Fibre Channel Interface Manual ), data requested by the host with a read command is retrieved from the buffer, if possible, before any disc access is initiated. If cache operation is not enabled, the buffer (still segmented with the required number of segments) is still used, but only as circular buffer segments during disc medium read operations (disregarding Prefetch operation for the moment). That is, the drive doe s not ch eck in th e buffer segments fo r the req uested read data, but go es di re ctly to th e medium to retrieve it. The retrieved data merely passes through some buffer segment on the way to the host. On a cache miss, all data transfers to the host are in accordance with buffer-full ratio rules. On a cache hit, the drive ignores the buffer -ful l rat io rul es. See the exp lanati on provide d with the infor mation about Mo de P age 02h (dis­connect/reconnect control) in the Fibre Channel Interface Manual.
The following is a simplified description of the prefetch/cache operation: Case A—read command is received and the first logical block is already in the cache:
1. Drive transfers to the initiator the first logical block requested plus all subsequent cont iguous logi cal blocks that are already in the cache. This data may be in multiple segments.
2. When a requested logical block is reached that is not in any cache segment, the drive fetches it and any remaining requested logical block addresses from the disc and puts them in a segment of the cache. The drive transfers the remaining requested logical blocks from the cache to the host in accordance with the Mode Select Disconnect/Reconnect parameters, page 02h.
3. If the prefetch feature is enabled, refer to section 4.5.2 for operation from this point.
Page 22
14
NL35 Series FC Product Manual, Rev. D
Case B—A Read command requests data, and the first logical block is not in any segment of the cache:
1. The drive fetches the requested logical blocks from the disc and transfers them into a segment, and then from there to the host in accordance with the Mode Select Disconnect/Reconnect parameters, page 02h.
2. If the prefetch feature is enabled, refer to section 4.5.2 for operation from this point.
During a prefetch, the drive crosses a cylinder boundary to fetch data only if the Discontinuity (DISC) bit is set to 1 in bit 4 of byte 2 of the Mode Select parameters page 08h. Default is zero for bit 4.
Each cache segment is actually a self-contained circular buffer whose length is an integer number of logical blocks. The wrap-around capability of the individual segments greatly enhances the cache’s overall perfor­mance, allowing a wide range of user-selectable configurations. The drive supports operation of any integer number of segments from 1 to 32. Divide the 6,877 Kbytes in the buffer by the number of segments to get the segment size in bytes; then divi de b y the sector size to get the num ber of sector s per se gmen t, any p ar tial sec­tors remaining are not used. Default is 3 segments.
Note. The size of each segment is not reported by Mode Sense command page 08h, bytes 14 and 15.
The value 0XFFFF is always reported regardless of the actual size of the segment. Sending a size specification using the Mode Select command (bytes 14 and 15) does not set up a new segment size. If the STRICT bit in Mode page 00h (byte 2, bit 1) is set to one, the drive responds as it does for any attempt to change an unchangeable parameter.

4.5.1 Caching write data

Write caching is a write operation by the drive that makes use of a drive buffer storage area where the data to be written to the medium is stored while the drive performs the Write command.
If read caching is enabled (RCD=0), then data written to the medium is retained in the cache to be made avail­able for future read cache hits. The same buffer space and segmentation is used as set up for read functions. The buffer segmentation scheme is set up or changed independently, having nothing to do with the state of RCD. When a write command is issued, if RCD=0, the cache is first checked to see if any logical blocks that are to be written are already stored in the cache from a previous read or write command. If there are, the respective cache segments are cleared. The new data is cached for subsequent Read commands.
If the number of write dat a logical blo cks excee d the size o f the segm ent b eing wr itten into, wh en th e en d of the segment is reached, the data is written i nto the b eginning of the same cache segment, overwriting the dat a that was written there at the beginning of the operation; however, the drive does not overwrite data that has not yet been written to the medium.
If write caching is enabled (WCE=1), then the drive may return Good status on a write command after the data has been transferred into the cache, but before the data has been written to the medium. If an error occurs while writing the data to the medium, and Good status has already been returned, a deferred error will be gen­erated.
The Synchronize Ca che command may be used to force the drive to write all cached wri te dat a to the med ium. Upon completion of a Synchronize Cache command, all data received from previous write commands will have been written to the medium.
Table 25 shows the mode default settings for the drive.

4.5.2 Prefetch operation

If the Prefetch feature is enabled, data in contiguous logical blocks on the disc immediately beyond that which was requested by a Read command are retrieved and stored in the buffer for immediate transfer from the buffer to the host on subsequent Read commands that request those logical blocks (this is true even if cache operation is disabled). Though the prefetch operation uses the buffer as a cache, finding the requested data in the buffer is a prefetch hit, not a cache operation hit.
Page 23
NL35 Series FC Product Manual, Rev. D
15
To enable Prefetch, use Mode Select page 08h, byte 12, bit 5 (Disable Read Ahead—DRA bit). DRA bit = 0 enables prefetch.
Since data that is prefetched replaces data already in some buffer segments, the host can limit the amount of prefetch data to optimize system performance. The Max Prefetch field (bytes 8 and 9) limits the amount of prefetch. The drive does not use the Prefetch Ceiling field (bytes 10 and 11).
During a prefetch operation, the drive crosses a cylinder boundary to fetch more data only if Mode parameters page 08h, byte 2, bit 4 is set to 1 (Discontinuity—DISC bit).
When prefetch (read look-ahead) is enabled (enabled by DRA = 0), it operates under the control of ARLA (Adaptive Read Look-Ahead). If the host uses software interleave, ARLA enables prefetch of contiguous blocks from the disc when it senses that a prefetch hit will likely occur, even if two consecutive read operations were not for physically contiguous blocks of data (e.g. “software interleave”). ARLA disables prefetch when it decides that a prefetch hit will not likely occur. If the host is not using software interleave, and if two sequential read operations are not for contiguous blocks of data, ARLA disables prefetch, but as long as sequential read operations request contiguous blocks of data, ARLA keeps prefetch enabled.

4.5.3 Optimizing cache performance for desktop and server applications

Desktop and server applications require different drive caching operations for optimal performance. This means it is difficult to provide a single configuration that meets both of these needs. In a desktop environment, you want to configure the cache to respond quickly to repetitive accesses of multiple small segments of data without taking the time to “look ahead” to the next contiguous segments of data. In a server environment, you want to configure the cache to provide large volumes of sequential data in a non-repetitive manner. In this case, the ability of the cache to “look ahead” to the next contiguous segments of sequential data is a good thing.
The Performance Mode (PM) bit controls the way the drive switches the cache buffer into different modes of segmentation. In “server mode” (PM bit = 0), the drive can dynamically change the number of cache buffer segments as needed to optimize the performance, based on the command stream from the host. In “desktop mode” (PM bit = 1), the number of segments is maintained at the value defined in Mode Page 8, Byte 13, at all times. For additional information about the PM bit, refer to the Unit Attention Parameters page (00h) of the Mode Sense command (1Ah) in the Fibre C hanne l Interface Product Manual, part number 77767496.
Page 24
16
NL35 Series FC Product Manual, Rev. D
Page 25
NL35 Series FC Product Manual, Rev. D
17

5.0 Reliability specifications

The following reliability specifications assume correct host and drive operational interface, including all inter­face timings, power supply voltages, environmental requirements and drive mounting constraints
Seek error rate Less than 1 error in 107 seeks Read Error Rates
Recovered Data Less than 10 errors in 1012 bits transferred (OEM default settings) Unrecovered Data Less than 1 sector in 1014 bits transferred Miscorrected Data Less than 1 sector in 1021 bits transferred
Interface error rate Less than 1 error in 1011 bits transferred with minimum receive eye
MTBF 1,000,000 hours Service life 5 years. Warranty To determine the warranty for a specific drive, use a web browser to
Preventive maintenance None required.
1
Less than 1 error in 1014 bits transferred with typical receive eye (see Section 9.6.4, "Differential PECL input." on page 68)
access the following web page: www.seagate.com/support/service/ From this page, click on the “Verify You r Warranty” link. You will be
asked to provide the drive serial number, model number (or part num­ber) and country of pur chase. The system will display t he warranty info r­mation for your drive.
1. Error rate specified with automatic retries and data correction with ECC enabled and all flaws reallocated.

5.1 Error rates

The error rates stated in this manual assume the following:
• The drive is operated in accordance with this manual using DC power as defined in paragraph 6.2, "DC
power requirements."
• Errors caused by host system failures are excluded from error rate computations.
• Assume random data.
• Default OEM error recovery settings are applied. This includes AWRE, ARRE, full read retries, full write
retries and full retry time.
Page 26
18
NL35 Series FC Product Manual, Rev. D

5.1.1 Recoverable Errors

Recovereable errors are those detected and corrected by the drive, and do not require user intervention. Recoverable Data errors will use correction, although ECC o n-the-fly is not considered fo r purposes o f recov-
ered error specifications. Recovered Data error rate is determined using read bits transferred for recoverable errors occurring during a
read, and using write bits transferred for recoverable errors occurring during a write.

5.1.2 Unrecoverable errors

Unrecoverable Data Errors (Sense Key = 03h) are specified at less than 1 sector in error per 1014 bits trans­ferred. Unrecoverable Data Errors resulting from the same cause are treated are 1 error for that block.

5.1.3 Seek errors

A seek error is defined as a failure of the drive to position the heads to the addressed track. After detecting an initial seek error, the drive automaticall y perf orms an error recovery process. If the error recover y process fails, a seek positioning error (Error code = 15h or 02h) will be reported with a Hardware error (04h) in the Sense Key. Recoverable seek errors are specified at Less than 10 errors in 108 seeks. Unrecoverable seek errors (Sense Key = 04h) are classified as drive failures.

5.1.4 Interface errors

An interface error is defined as a failure of the receiver on a port to recover the data as transmitted by the device port connected to the receiver. The error may be detected as a running disparity error, illegal code, loss of word sync, or CRC error. The total error rate for a loop of devices is the sum of the individual device error rates.

5.2 Reli ab ilit y and servi ce

You can enhance the reliability of NL35 Serie s disc drives by ensur ing that the drive receives adequa te co oling. Section 6.0 provides temperature measurements and other information that may be used to enhance the ser­vice life of the drive. Section 8.2 provides recommended air-flow information.
Page 27
NL35 Series FC Product Manual, Rev. D
19

5.2.1 Mean Time Between Failure (MTBF)

The production disc drive shall achieve an MTBF of 1,000,000 hours when operated in an environment that ensures the HDA case temperatures specified in Section 6.4 are not exceeded. Short-term excursions up to the specification limits of the operating environment will not affect MTBF performance. Continual or sustained operation at case temperatures above the values shown in Section 6.4.1 may degrade product reliability.
Estimated power-on operation hours means power-up hours per disc drive times the total number of disc drives in service. Each disc drive shall have accumulated at least nine months of operation. Data shall be cal­culated on a rolling average base for a minimum period of six months.
MTBF is based on the following assumptions:
• 8,760 power-on hours per year.
• 250 average on/off cycles per year.
• Operations at nominal voltages.
• Systems will provide adequate cooling to ensure the case temperatures specified in Section 6.4.1 are not
exceeded. Drive failure means any stoppage or substandard performance caused by drive malfunction. A S.M.A.R.T. predictive failure indicates that the drive is deteriorating to an imminent failure and is considered
an MTBF hit.

5.2.2 Preventive mainte nance

No routine scheduled preventive maintenance is required.

5.2.3 Hot plugging the drive

Inserting and removing the drive on the FC-AL will interrupt loop operation. The interruption occurs when the receiver of the next device in the loop must synchronize to a different input signal. FC error detection mecha­nisms, character sync, running disp a rity, word sync, and CRC are able to detect any error. Recovery is initiated based on the type of error.
The disc drive defaults to the FC-AL Monitoring state, Pass-through state, when it is powered-on by switching the power or hot plugged. The control line to an optional port bypass circuit (external to the drive), defaults to the Enable Bypass state. If the bypass circuit is present, the next device in the loop will continue to receive the output of the previous device to the newly inserted device. If the bypass circuit is not present, loop operation is temporarily disrupted until the next device starts receiving the output from the newly inserted device and regains synchronization to the new input.
The Pass-through state is disabled while the drive perfo rms self test of the FC interface. The control line for an external port bypass circuit remains in the Enable Bypass state while self test is running. If the bypass circuit is present, loop oper ation m ay con tinue. If the byp ass circ uit is not pres ent, loo p ope ration will be h alted while the self test of the FC interface runs.
When the self test completes successfully, the control line to the bypass circuit is disabled and the drive enters the FC-AL Initializing st a te. The receiver on the ne xt device i n the loo p must synch ronize t o outpu t of the newly inserted drive.
If the self-test fails, the control line to the bypass circuit remains in the Enable Bypass state. Note. It is the responsibility of the systems integrator to assure that no temperature, energy, voltage haz-
ard, or ESD potential hazard is presented during the hot connect/disconnect operation. Discharge the static electricity from the drive carrier prior to inserting it into the system.
Caution. The drive motor m ust come to a com pl ete s top pr ior to ch angi ng the pla ne of o pera ti on. T his time i s
required to insure data integrity.
Page 28
20
NL35 Series FC Product Manual, Rev. D

5.2.4 S.M.A.R.T.

S.M.A.R.T. is an acronym for Self-Monitoring Analysis and Reporting Technology. This technology is intended to recognize conditions that indicate imminent drive failure and is designed to provide sufficient warning of a failure to allow you to back up the data before an actual failure occurs.
Note. The drive’ s f irmwar e moni tor s specific attr ibutes for degr adatio n ove r tim e b ut can ’ t predi ct in sta nt a-
neous drive failures.
Each monitored attribute has been selected to monitor a specific set of failure conditions in the operating per­formance of the drive and the thresholds are optimized to minimize “false” and “failed” predi ctions.
Controlling S.M.A.R.T.
The operating mode of S.M.A.R. T. is controlled by the DEXCPT and PERF bits on the Informational Exce ptions Control mode page (1Ch). Use the DEXCPT bit to enable or disable the S.M.A.R.T. feature. Setting the DEX­CPT bit disables all S.M.A.R.T. functions. When enab led, S .M. A.R.T. collects on -line d ata as the drive p erfor ms normal read and write operations. When the PERF bit is set, the drive is considered to be in “On-line Mode Only” and will not perform off-line functions.
You can measure off-line attributes and force the drive to save the data by using the Rezero Unit command. Forcing S.M.A.R.T. resets the timer so that the next scheduled interrupt is in two hours.
You can interrogate the drive through th e host t o dete rmine the time remaining b efore the ne xt schedu l ed me a­surement and d at a logg i ng p rocess occur s . To accomplish this, i ssue a Log Sense command to log page 0x3E. This allows you to control when S.M.A.R.T. interruptions occur. Forcing S.M.A.R.T. with the RTZ command resets the timer.
Performance impact
S.M.A.R.T. attribute data is saved to the disc so that the events that caused a predictive failure can be recre­ated. The drive measures and saves parameters once every two hours subject to an idle period on the FC-AL bus. The process of measuring off-line attribute data and saving data to the disc is uninterruptable. The maxi­mum on-line only processing delay is summarized below:
Maximum processing delay
S.M.A.R.T. delay times
On-line only delay DEXCPT = 0, PERF = 1
60 milliseconds
Fully-enabled delay DEXCP T = 0, PE R F = 0
370 milliseconds
Reporting control
Reporting is controlled by the MRIE bits in the Informational Exceptions Control mode page (1Ch). Subject to the reporting method, the firmware will issue to the host an 01-5Dxx sense code. The error code is preserved through bus resets and power cycles.
Determining rate
S.M.A.R.T. monitors the rate at which errors occur and si gna ls a predi ctive fai lure if the rat e of degrad ed err ors increases to an unacceptabl e level. To determine rate, error events are logged and com pa red to the num ber of total operations for a given attribute. The interval defines the number of operations over which to measure the rate. The counter that keeps track of the current number of operations is referred to as the Interval Counter.
S.M.A.R.T. measures error rates. All errors for each monitored attribute are recorded. A counter keeps track of the number of errors for the current interval. This counter is referred to as the Failure Counter.
Page 29
NL35 Series FC Product Manual, Rev. D
21
Error rate is the number of errors per oper ation. The algori thm tha t S .M.A.R .T. uses to record rate s of err or i s to set thresholds for the number of errors and their interval. If the number of errors exceeds the threshold before the interval expires, the error rate is considered to be unacceptable. If the number of errors does not exceed the threshold before the interval expires, the error rate is considered to be acceptable. In either case, the inter­val and failure counters are reset and the process starts over.
Predictive failures
S.M.A.R.T. signals predictive failures when the drive is performing unacceptably for a period of time. The firm­ware keeps a running count of the number of times the error rate for each attribute is unacceptable. To accom­plish this, a counter is incremented each time the error rate is unacceptable and decremented (not to exceed zero) whenever the error rate is acceptable. If the counter continually increments such that it reaches the pre­dictive threshold, a predictive failure is signaled. This counter is referred to as the Failure History Counter. There is a separate Failure History Counter for each attribute.

5.2.5 Thermal monitor

NL35 Series drives implement a temperature warning system which:
1. Signals the host if the temperature exceeds a value which would threaten the drive.
2. Signals the host if the temperature exceeds a user-specified value.
3. Saves a S.M.A.R.T. data frame on the drive which exceed the threatening temperature value. A temperature sensor monitors the drive temperature and issues a warning over the interface when the tem-
perature exceeds a set threshold. The temperature is measured at power-up and then at ten-minute intervals after power-up.
The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the speci­fied limit in compliance with the SCSI standard. The drive temperature is reported in the FRU code field of mode sense dat a. You can use this infor matio n to deter mine if the warning i s due to t he tem per atur e excee ding the drive threatening temperature or the user-specified temperature.
This feature is controlled by the En able W a rni ng (EWasc) bit, and the reporting mechanism is controlled by the Method of Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) mode page (1Ch).
The current algorithm implements two temperature trip points. The first trip point is set at 68°C which is the maximum temperature limit according to the drive specification. The second trip point is user-selectable using the Log Select command. The re feren ce tempe ratur e p aram eter in the tempera ture log page (see Table 1) can be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of 0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense code is sent to the host to indicate the rounding of the parameter field.
T ab le 1: Temperature Log page (0Dh)
Parameter Code Description
0000h Primary Temperature 0001h Reference Temperature
When the first tem perature trip point is exceeded , S. M.A .R.T. data is collected and a fram e is save d to th e disc.
Page 30
22
NL35 Series FC Product Manual, Rev. D

5.2.6 Drive Self Test (DST)

Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the functionality of the drive at a system level.
There are two test coverage options implemented in DST:
1. Extended test
2. Short text The most thorough option is the extended test that performs various tests on the drive and scans every logical
block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does some fundamental tests and scans portions of the media.
If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to Seagate for service.
5.2.6.1 DST Failure Definition
The drive will present a “diagnostic failed” condition through the self-tests results value of the diagnostic log page if a functional failure is encountered during DST. The channel and servo parameters are not modified to test the drive more stringently, and the number of retries are not reduced. All retries and recovery processes are enabled during the test. If data is recoverable, no fa ilure condition will be reported regardless of the number of retries required to recover the data.
The following conditions are considered DST failure conditions:
• Seek error after retries are exhausted
• Track-follow error after retries are exhausted
• Read error after retries are exhausted
• Write error after retries are exhausted Recovered errors will not be reported as diagnostic failures.
5.2.6.2 Implementation
This section provides all of the information necessary to implement the DST function on this drive.
5.2.6.2.1 State of the drive prior to testing
The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditio ns, and not erro rs. For example, a drive may be in process of doing a form at, or anothe r D ST. It is the responsibility o f the ho st applic atio n to det erm ine the “ not ready” cause.
While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.
A Drive Not Ready condition is reported by the drive under the following conditions:
• Motor will not spin
• Motor will not lock to speed
• Servo will not lock on track
• Drive cannot read configuration tables from the disc In these conditions, the drive responds to a Test Unit Ready command with an 02/04/00 or 02/04/03 code.
Page 31
NL35 Series FC Product Manual, Rev. D
23
5.2.6.2.2 Invoking DST
To invoke DST, submit the Send Diagnostic command with the appropriate Function Code (001b for the short test or 010b for the extended test) in bytes 1, bits 5, 6, and 7. Refer to the Fibre Channel Interface Product Manual, part number 77767496, for additional information about invoking DST.
5.2.6.2.3 Short and extended tests
DST has two testing options:
1. short
2. extended These testing options are described in the following two subsections. Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan
segment.
Short test (Function Code: 001b)
The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within 120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and scans portions of the media. A complete rea d/ver ify scan is not per formed and onl y factua l failu res will report a fault condition. This option provides a quick confidence test of the drive.
Extended test (Function Code: 010b)
The objective of the extended test option is to empirically test critical drive components. For example, the seek tests and on-track operations test the positioning mechanism. The read operation tests the read head element and the media surface. The write element is tested through read/write/read operations. The integrity of the media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of these tests.
The anticipated length of the Extended test is reported through the Control Mode page.
5.2.6.2.4 Log page entries
When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created by inserting a new self-te st parameter block a t the beginning of t he se lf-test results log p a ram eter section of the log page. Existing data will be moved to make room for the new parameter block. The drive reports 20 param­eter blocks in the log p ag e. If th ere are more than 20 p ar amet er blocks, the least r ecent p a rame ter block will be deleted. The new parameter block will be initialized as follows:
1. The Function Code field is set to the same value as sent in the DST command
2. The Self-Test Results Value field is set to Fh
3. The drive will store the log page to non-volatile memory After a self-test is complete or has been aborted, the drive updates the Self-Test Results Value field in its Self-
Test Results Log page in non-volatile memory. The host may use Log Sense to read the results from up to the last 20 self-tests performed by the drive. The self-test results value is a 4-bit field that reports the results of the test. If the field is zero, the drive passed with no errors detected by the DST. If the field is not zero, the test failed for the reason reported in the field.
The drive will report the failure condition and LBA (if applicable) in the Self-test Results Log parameter. The Sense key, ASC, ASCQ, and FRU are used to report the failure condition.
Page 32
24
NL35 Series FC Product Manual, Rev. D
5.2.6.2.5 Abort
There are several ways to abort a diagnostic. You can use a SCSI Bus Reset or a Bus Device Reset message to abort the diagnostic.
You can abort a DST executing in background mode by using the abort code in the DST Function Code field. This will cause a 01 (self-test aborted by the application client) code to appear in the self-test results values log. All other abort mechanisms will be reported as a 02 (self-test routine was interrupted by a reset condition).

5.2.7 Product warranty

Beginning on the date of shipment to the customer and continuing for a period of three years, Seagate war­rants that each product (including components and subassemblies) that fails to function properly under normal use due to defect in materials or workmanship or due to nonconformance to the applicable specifications will be repaired or replaced, at Seagate’s option and at no charge to the customer, if returned by customer at cus­tomer’s expense to Seagate’s designated facility in accordance with Seagate’s warranty procedure. Seagate will pay for transporting the repair or replacement item to the custom er. For more detailed warranty information, refer to the standard terms and conditions of purchase for Seagate products. Refer to Section 10 for contact information.
Shipping
When transporting or shipping a drive, use only a Seagate-approved container. Keep your original box. Seagate approved containers are easily identified by the Seagate Approved Package label. Shippi ng a drive in a non-approved container voids the drive warranty.
Seagate repair centers may refuse receipt of components improperly packaged or obviously damaged in tran­sit. Contact your authorized Seagate distributor to purchase additional boxes. Seagate recommends shipping by an air-ride carrier experienced in handling computer equipment.
Product repair and return information
Seagate customer service centers are the only facilities authorized to service Seagate drives. Seagate does not sanction any third-party repair facilities. Any unauthorized repair or tampering with the factory seal voids the warranty.
Page 33
NL35 Series FC Product Manual, Rev. D
25

6.0 Physical/electrical specifications

This section provides information relating to the physical and electrical characteristics of the drive.

6.1 AC power re quirements

None.

6.2 DC power re quirements

The voltage and current requirements for a single drive are shown below. Values indicated apply at the drive connector.
T a ble 11: S T3500071FC/ST3400071FC DC power requirements
1 Gbit 2 Gbit
Notes (Amps) (Amps) (Amps) (Amps)
Voltage +5V +12V [2] +5V +12V [2] Regulation [5] ±5% ±5% [2] ± 5% ±5% [2] Avg idle current DC X [1] [7]
Maximum starting current
(peak DC) DC 3σ [3]
(peak AC) AC 3σ [3] Delayed motor start (max) DC 3σ [1] [4] Peak operating current:
Typical DC X [1] [6] Maximum DC 3σ [1] Maximum (peak) DC 3σ
0.94 0.48 1.00 0.48
1.04 2.08 1.10 2.10
1.50 3.54 1.56 3.50
0.57 0.03 0.59 0.03
0.99 0.75 1.05 0.74
1.01 0.77 1.07 0.76
1.68 1.90 1.76 1.90
[1] Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these val-
ues. Power supply at nominal voltage. Number of drives tested = 6, 35 Degrees C ambient.
[2] For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching
7,200 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been
completed and that the drive is able to accept selection by the host initiator.
[3] See +12V current profile. [4] This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start
Motor command.
Page 34
26
NL35 Series FC Product Manual, Rev. D
[5] See paragraph 6.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and
transient response.
[6] Operating condition is defined as random 8 block reads at 161 I/Os per second.
Current and power specified at nominal voltages. Decreasing +5 volt supply by 5% increases 5 volt cur­rent by <0.5%. Decreasing +12 volt supply by 5% increases 12 volt current by 1.4%.
[7] During idle, the drive heads are relocated every 60 seconds to a random location within the band from
track zero to one-fourth of maximum track.
General DC power requirement notes.
1. Minimum current loading for each supply voltage is not less than 1.2% of the maximum operating current shown.
2. The +5V and +12V supplies should employ separate ground returns.
3. Where power is provided to multiple drives from a common supply, careful consideration for individual drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to each device.
4. Parameters, other than spindle start, are measured after a 10-minute warm up.
5. No terminator power.

6.2.1 Conducted noise immunity

Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 20 MHz. Maximum allowed no ise val ue s given bel ow are pea k to peak mea s urem ent s a nd a pply a t the dr ive po wer co n­nector.
+5 V = 250 mV pp from 10 Hz to 10 MHz.
250 mV pp from 10 MHz to 20 MHz.
+12 V = 400 mV pp from 10 Hz to 100 Hz.
800 mV pp from 100 Hz to 8 KHz. 450 mV pp from 8 KHz to 20 KHz. 400 mV pp from 20 KHz to 10 MHz. 250 mV pp from 10 KHz to 20 MHz.

6.2.2 Power sequencing

The drive does not require power sequencing. The drive protects against inadvertent writing during power-up and down.
Page 35
NL35 Series FC Product Manual, Rev. D
27

6.3 Power dissipation

Typical power dissipation under idle conditions is 10.49 watts (35.79 BTUs per hour) during 1 Gbit operation. Typical power dissipation under idle conditions is 10.75 watts (36.68 BTUs per hour) during 2 Gbit operation.
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure
2). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by
3.4123.
ST3500001FC DC CURRENT/POWER vs THROUGHPUT (1Gb) Random 8 Blo ck Re ads
1.8 0 0
1.6 0 0
1.4 0 0
18.0 0
16.0 0
14.0 0
5Volt A 12 V o l t A Watts
1.2 0 0
1.0 0 0
0.800
Amperes
0.600
0.400
0.200
0.000
0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0
I/Os per Se cond
Figure 2. DC current and power vs. input/output operations per second (1 Gbit)
ST3500001FC DC CURRENT/POWER vs THROUGHPUT (2Gb) Random 8 Blo ck Re ads
1.8 0 0
1.6 0 0
1.4 0 0
1.2 0 0
12.0 0
10.0 0
8.00
6.00
4.00
2.00
0.00
18.0 0
16.0 0
14.0 0
12.0 0
Power (watts)
5Volt A 12 V o l t A Watts
Power (watts)
1.0 0 0
0.800
Amperes
0.600
0.400
0.200
0.000
0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0
Figure 3. DC current and power vs. input/output operations per second (2 Gbit)
10.0 0
8.00
6.00
4.00
2.00
0.00
I/Os per Se cond
Page 36
28
NL35 Series FC Product Manual, Rev. D

6.4 Environmental limits

Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F (14.8°C). Maximum wet bulb temperature is 82°F (28°C).

6.4.1 Temperature

a. Operating
The maximum allowable continuous or sustained HDA case temperature for the rated MTBF is 122°F (50°C) The maximum allowable HDA case temperature is 60°C. Occasional excursions of HDA case tem­peratures above 122°F (50°C) or below 41°F (5°C) may occur without impact to specified MTBF. Continual or sustained operation at HDA case temperatures outside these limits may degrade MTBF.
Provided the HDA case temperatures limits are met, the drive meets all specifications over a 41°F to 131°F (5°C to 55°C) drive ambient temperature range with a maximum temperature gradient of 36°F (20°C) per hour . Air flow may be needed in the drive enclosu re to keep within this range (see Se ction 8.3). Operation at HDA case temperatur es out side thi s ra nge m ay adve rsely af fe ct the d rives ab ility t o mee t speci ficatio ns. To confirm that the required cooling for the electronics and HDA case is provided, place the drive in its final mechanical configuration, perform random write/read operations and measure the HDA case temperature after it has stabilized.
b. Non-operating
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This specification assum es th at th e dr iv e is p ackaged in the shipping cont ain er desi gne d by Seagate for use w ith drive.
HDA Temperature Check Point
Figure 4. Location of the HDA Temperature check point
0.5”

6.4.2 Relative humidity

The values below assume that no condensation on the drive occurs. a. Operating
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour non-condensing.
b. Non-operating
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour non-condensing.

6.4.3 Effective altitude (sea level)

a. Operating
–200 to +10,000 feet (–61 to +3,048 meters)
b. Non-operating
–200 to +40,000 feet (–61 to +12,210 meters)
Page 37
NL35 Series FC Product Manual, Rev. D
29

6.4.4 Shock and vibration

Shock and vibration limits specified in this document are measured directly on the drive chassis. If the drive is installed in an enclosure to which the stated shock and/or vibration criteria is applied, resonances may occur internally to t he e nclosure resulting in drive m oveme nt i n excess of t he st at ed l im its. If t hi s situat i on is app ar ent, it may be necessary to modify the enclosure to minimize drive movement.
The limits of shock and vibration defined within this document are specified with the drive mounted by any of the four methods shown in Figure 5, and in accordance with the restrictions of Section 8.4.
6.4.4.1 Shock
a. Operating—normal
The drive, as in sta lled for normal op erat ion, s hal l op erat e er ror fr ee wh ile sub je cted to in term i ttent shock not exceeding 15 Gs at a maximum duration of 11 msec (half sinewave). The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not exceeding 25 Gs at a maximum duration of 2 msec (half sinewave). Shock may be applied in the X, Y, or Z axis.
b. Operating—abnormal
Equipment, as installed for normal operation, does not incur physical damage while subjected to intermit­tent shock not exceeding 40 Gs at a maximum duration of 11 msec (half sinewave). Shock occurring at abnormal levels may promote degraded operational performance during the abnormal shock period. Speci­fied operational performance will continue when normal operating shock levels resume. Shock may be applied in the X, Y, or Z axis. Shock is not to be repeated more than two times per second.
c. Non-operating
The limits of non-operating shock shall apply to all conditions of handling and transportation. This includes both isolated drives and integrated drives.
The drive subjected to nonrepetitive shock not exceeding 75 Gs at a maximum duration of 11 msec (half sinewave) shall not exhibit device damage or performance degradation. Shock may be applied in the X, Y, or Z axis.
The drive subjected to nonrepetitive shock not exceeding 225 Gs at a maximum duration of 2 msec (half sinewave) does not exhibit device damage or performance degradation. Shock may be applied in the X, Y, or Z axis.
The drive subjected to nonrepetitive shock not exceeding 120 Gs at a maximum duration of 0.5 msec (half sinewave) does not exhibit device damage or performance degradation. Shock may be applied in the X, Y, or Z axis.
d. Packaged
Disc drives shipped as loose load (not palletized) general freight will be packaged to withstand drops from heights as defined in the table below. For additional details refer to Seagate specifications 30190-001 (under 100 lbs/45 kg) or 30191-001 (over 100 lbs/45 Kg).
Package size Packaged/product weight Drop height
<600 cu in (<9,800 cu cm) Any 60 in (1524 mm) 600-1800 cu in (9,800-19,700 cu cm) 0-20 lb (0 to 9.1 kg) 48 in (1219 mm) >1800 cu in (>19,700 cu cm) 0-20 lb (0 to 9.1 kg) 42 in (1067 mm) >600 cu in (>9,800 cu cm) 20-40 lb (9.1 to 18.1 kg) 36 in (914 mm)
Drives packaged in single or multipacks with a gross weight of 20 pounds (8.95 kg) or less by Seagate for general freight shipment shall withstand a drop test from 48 inches (1,070 mm) against a concrete floor or equivalent.
Page 38
30
NL35 Series FC Product Manual, Rev. D
Z
Y
X
Figure 5. Recommend e d m ounting
X
Z
Y
Page 39
NL35 Series FC Product Manual, Rev. D
31
6.4.4.2 Vibration
a. Operating - normal
The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding
5-22 Hz @ 0.25 G (zero to peak) 22-350 Hz @ 0.50 G (zero to peak) 350-500 Hz @ 0.25 G (zero to peak)
Vibration may be applied in the X, Y, or Z axis. Operating normal translational random flat profile 10 - 500 Hz 0.5 G RMS (grams root mean square)
b. Operating - abnormal
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding:
15 minutes of duration at major resonant frequency 0-22 Hz @ 0.25 G (X, Y, or Z axis, zero to peak)
22-350 Hz @ 0.50 G (X, Y, or Z axis, zero to peak) 350-500 Hz @ 0.25 G (X, Y, or Z axis, zero to peak)
Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available.
Operating abnormal translational random flat profile 10 - 500 Hz 1.2 G RMS (grams root mean square)
c. Non-operating
The limits of non-operating vibration shall apply to all conditions of handling and transportation. This includes both isolated drives and integrated drives.
The drive shall not incur physical damage or degraded performance as a result of continuous vibration not exceeding
5-22 Hz @ 0.25 G (zero to peak) 22-350 Hz @ 5.00 G (zero to peak)
350-500 Hz @ 1.0 G (zero to peak) Vibration may be applied in the X, Y, or Z axis. Non-operating translational random flat profile 10 - 500 Hz 1.2 G RMS (grams root mean square)

6.4.5 Air cleanliness

The drive is designed to operate in a typical office environment with minimal environmental control.
Page 40
32
NL35 Series FC Product Manual, Rev. D

6.4.6 Corrosive environment

Seagate electronic drive components pass accelerated corrosion testing equivalent to 10 years exposure to light industrial environments containing sulfurous gases, chlorine and nitric oxide, classes G and H per ASTM B845. However, this accelerated testing cannot duplicate every potential application environment.
Users should use caution exposing any electronic components to uncontrolled chemical pollutants and corro­sive chemicals as electr onic dr i ve com ponen t reliab ilit y can be af fecte d by th e i nst allation environment. Th e si l- ver, copper, nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide, chloride, and nitr ate c ont ami na nt s. S ulfur is found to be the m ost dam aging . In ad di tion, e lectron i c comp onent s should never be exposed to condensing water on the surface of the printed circuit board assembly (PCBA) or exposed to an am bient rel at ive hum idity gr eate r th an 9 5%. Mat erial s used in cabin et fa bri cation , such as vulca­nized rubber, that can outgas corrosive compounds should be minimized or eliminated. The useful life of any electronic equipment may be extended by replacing materials near circuitry with sulfide-free alternatives.

6.4.7 Acoustics

The typical sound power duri ng idle mod e as measured to IS O 7779 specifi ca tion are l isted in the t abl e below.
T ab le 2: Typical idle mode sound power
ST3500071FC and ST3400071FC
3.1 bels
There will not be any discrete tones more than 10 dB above the masking noise on typical drives when mea­sured according to Seagate specification 30553-001. There will not be any tones more than 24 dB above the masking noise on any drive.

6.4.8 Electromagn etic susc ept ibili ty

See Section 2.1.2.
Page 41
NL35 Series FC Product Manual, Rev. D
33

6.5 Mechanical specifications

The following nominal dimensions are exclusive of the decorative front panel accessory. However, dimensions of the front panel are shown in figure below. Refer to Figure 6 for detailed mounting configuration dimensions. See Section 8.4, “Drive mounting.”
Height: 1.010 +/- 0.14 in. 25.654 +/- .356 mm Width: 4.0 +/- .008 in. 101.6 +/- .203 mm Depth: 5.770 in. +/- 0.008 in. 146.558 mm +/- 0.203 mm Weight: 1.6 pounds 0.726 kilograms
Figure 6. Mounting configuration dimensions
1.010 +/- .014 25.654 +/- .356
5.770 +/- .008 146.558 +/- .203
4.000 +/- .008 101.6 +/- .203
3.750 +/- .010 95.25 +/- .254 .125 +/- .010 3.175 +/- .254
1.750 +/- .010 44.45 +/- .254
1.122 +/- .010 28.4988 +/- .254
4.000 +/- .010 101.6 +/- .254 .250 +/- .008 6.35 +/- .254
1.638 +/- .010 41.605 +/- .254 .180 +/- 0.021 4.572 +/- 0.533
1.625 +/- 0.010 41.275 +/- .254
1.469 +/- 0.020 37.31 +/- 0.50 .276 +/- 0.040 7.0104 +/- 1.0160
Page 42
34
NL35 Series FC Product Manual, Rev. D
Page 43
NL35 Series FC Product Manual, Rev. D
35

7.0 Defect and error management

The drive, as delivered, complies with this product manual. The read error rates and specified storage capaci­ties are not dependent upon use of defect management routines by the host (initiator).
Defect and error management in the SCSI protocol involves the drive internal defect/error management and FC-AL system error considerations (errors in communications between the initiator and the drive). Tools for use in designing a defect/error management plan are briefly outlined in this section. References to other sec­tions are provided when necessary.

7.1 Drive internal defects/errors

During the initial drive format operation at the factory, media defects are identified, tagged as being unusable, and their locations recorded on the drive primary defects list (referred to as the “P’ list and also as the ETF defect list). At factory format time, these known defects are also reallocated, that is, reassigned to a new place on the medium and the location listed in the defects reallocation table. The “P” list is not altered after factory formatting. Locations of defects found and reallocated during error recovery procedures after drive shipment are listed in the “G” list (defects growth list). The “P” and “G” lists may be referenced by the initiator using the Read Defect Data command.
Details of the SCSI commands supported by the drive are described in the Fibre Channel Interface Manual. Also, more information on the drive Error Recovery philosophy is presented in the Fibre Channel Interface Manual.

7.2 Drive er ror recov ery procedures

When an error occurs du ri ng dr ive ope ration, the drive, if program med t o do so, pe rfor ms er ror recove ry pro ce­dures to attempt to reco ver the dat a. T he err or r ecover y proce dure s used depend on the options pre viously set in the Error Recovery Parameters mode page. Error recovery and defect management may involve using sev­eral SCSI commands described in the Fibre Channel Interface Manual. The drive implements selectable error recovery time limits required in video applications.
The error r ecover y sche me suppo rted by t he d ri ve p rovide s a way to contr ol th e to tal error recovery time for the entire command in addition to controlling the recovery level for a single LBA. The total amount of time spent in error recovery for a command can be limited using the Recovery Time Limit bytes in the Error Recovery mode page. The total amount of time spent in error recovery for a single LBA can be limited using the Read Retry Count or Write Retry Count bytes in the Error Recovery mode page.
The drive firmware error recovery algorithms consists of 11 levels for read recoveries and five levels for write. Each level may consist of multiple steps, where a step is defined as a recovery function involving a single re­read or re-write attempt. The maximum level used by the drive in LBA recovery is determined by the read and write retry counts.
Page 44
36
NL35 Series FC Product Manual, Rev. D
Table 12 equates the read and write retry count with the maximum possible recovery time for read and write recovery of individual LBAs. The times given do not include time taken to perform reallocations. Reallocations are performed when the ARRE bit (for reads) or AWRE bit (for writes) is one, the RC bit is zero, and the recov­ery time limit for the command has not yet been met. Time needed to perform reallocation is not counted against the recovery time limit.
When the RC bit is one, reallocations are disabled even if the ARRE or AWRE bits are one. The drive will still perform data recovery actions within the limits defined by the Read Retry Count, Write Retry Count, and Recovery Time Limit parameters. However, the drive does not report any unrecovered errors.
Table 12: Read and write retry count maximum recovery times
Read retry
1
count
0 108.3 0 50.0 1 125.0 1 75.0 2 424.8 2 116.6 3 474.8 3 141.6 4 541.5 4 249.9 5 599.8 5 308.2 (default) 6 666.4 7 841.3 8 958.0 9 1091.2 10 1166.2 11 2066.1 (default)
Maximum recovery time per LBA (cumulative, msec)
Write retry
1
count
Maximum recovery time per LBA (cumulative, msec)
[1] These values are subject to change.
Setting these retry counts to a value below the default setting could result in an increased unrecovered error rate which may exceed the value given in this product manual. A setting of zero (0) will result in the drive not performing error recovery.
For example, suppose the Read/Write Recovery page has the RC bit set to 0, read retry count set to 4, and the recovery time limit field (Mode Sense page 01, bytes 10 and 11) set to FF FF hex (maximum). A four LBA Read command is allowed to take up to 541.5 msec recovery time for each of the four LBAs in the command. If the recovery time limit is set to 00 C8 hex (200 msec decimal) a four LB A read comm and is allowed to take up to 200 msec for all error recovery within that command. The use of the Recovery Time Limit field allows finer granularity on control of the time spent in error recovery. The recovery time limit only starts counting when the drive is executing error recovery and it restarts on each command. Therefore, each command’s total recovery time is subject to the recovery time limi t. Note: A recovery time limit of 0 will use the drive’s default value of FF FF. Minimum recovery time limit is achieved by setting the Recovery Time Limit field to 00 01.
Page 45
NL35 Series FC Product Manual, Rev. D
37

7.3 FC-AL system errors

Information on the reporting of operational errors or faults across the interface is given in the Fibre Channel Interface Manual. The FCP Response returns information to the host about numerous kinds of errors or faults.
The Receive Diagnostic Results reports the results of diagnostic operations performed by the drive. Status returned by the drive to the initiator is described in the Fibre Channel Interface Manual. Status reporting
plays a role in systems err or manag ement and its use in that resp ect is d escribed in se ctions whe re t he va rious commands are discussed.

7.4 Background Media Scan

Background Media Scan (BGMS) is a self-initiated media scan. It performs sequential reads across the entire pack of the media while the drive is idle. In RAID arrays, BGMS allows hot spare drives to be scanned for defects prior to being put into service by the host system. On regualr duty drives, if the host system makes use of the BGMS Log Page, it can avoid placing data in suspect locations on the media. Unrecovered error sites found during BGMS will be logged and recovered error sites will be logged or reallocated per ARRE/AWRE settings.
With BGMS, the host system can consume less power and system overhead by only checking BGMS status/ results rather th an tying up th e bus a nd consu ming p ow er in the pr ocess o f host- initiated media scanning activ ­ity.
Since the background scan functions are only done during idle periods, BGMS causes a negligible impact to system performance. Background media scan will begin after 500ms of idle time. Other features that normally use idle time to function will function normally because BGMS functions for bursts of 800ms and then sus­pends activity to allow other backg roun d functi ons to opera te. Addi tionall y, BGMS operates in segments of 400 block reads, checking for host commands upon completion of each of the block segments.
The BGMS function will complete any BGMS-initiated error recovery prio r to returning to se rvice host-initiated commands. Overhead associ ate d with a retu rn to host- servic ing activity from BGMS only impacts the first com­mand that interrupted BGMS. This results in a typical delay of about 4 ms.

7.4.1 Media Pre-Scan

Media Pre-Scan is an option al featur e that al lows the drive to hand l e unreco vered media err ors tha t would ot h­erwise have been found by the host system during critical data accesses early in the integration process at customer sites. This should reduce integration DPPM (defective parts per million) by identifying and repairing media errors that arose during shipping and handling. Media Pre-Scan replaces all host-initiated Write com­mands with Write-Verify commands when the drive is accessing areas of the media yet untouched by BGMS­initiated scanning activity.
The drive will attempt to run BGMS on the entire pack of the drive. This will result in increasingly large portion so fthe drive having been accesed, provided there is adequate idle time to allow BGMS to run. During the Pre­Scan period, all Write commands that are in un-BGMS-scanned areas are converted to Write-Verify com­mands. To expedite the scan of the full pack and the subsequenty exit from the Pre-Scan period, BGMS will begin immediately when the drive goes to idle during the Pre-Scan period, as opposed to waiting 500ms as is done under non-Pre-Scan conditions.
Page 46
38
NL35 Series FC Product Manual, Rev. D
Page 47
NL35 Series FC Product Manual, Rev. D
39

8.0 Installation

NL35 Series disc drive installation is a plug-and-play process. There are no jumpers, switches, or terminators on the drive. Simply plug the drive into the host’s 40-pin Fibre Channel backpanel connector (FC-SCA)—no cables are required. See Section 9.5 for additional information about this connector.
Use the FC-AL interface to select drive ID and all option configurations for devices on the loop. If multiple devices are on the same FC-AL and physical addresses are used, set the device selection ID s (SEL
IDs) on the backp anel so that no two devices have th e sam e select ion ID. T his is ca lled the har d assi gn ed arbi ­trated loop physical ad dress ( AL_PA). There are 125 AL_PAs available (see Table 32). If you set the AL _PA on the backpanel to any value other than 0, the device plugged into the backpanel’s SCA connector inherits this AL_PA. In the event you don’t successfully assign unique hard addresses (and therefore have duplicate selec­tion IDs assigned to two or more devices), the FC-AL generates a message indicating this condition. If you set the AL_PA on the backpanel to a value of 0, the system issues a unique soft-assigned physical address auto­matically.
Loop initialization is the process used to verify or obtain an address. The loop initialization process is per­formed when pow er is applied to the drive, whe n a device is added or removed from the F ibre Cha nnel loop , or when a device times out attempting to win arbitration.
• Set all option selections in the connector prior to applying power to the drive. If you change options after applying power to the drive, recycle the drive power to activate the new settings.
• It is not necessary to low-level format this drive. Default configuration units are shipped from the factory low­level formatted in 5 12-b yte logi cal blocks. You need to reformat the drive on ly if yo u want to se lect a di f fer ent logical block size.

8.1 Drive ID/option selection

All drive options are made through the interface connector (J1). Table provides the pin descriptions for the 40­pin Fibre Channel single connector (J1).

8.2 Drive or ientat ion

The drive may be mounted in any orientation. All drive performance characterizations, however, have been done with the drive in horizontal (discs level) and vertical (drive on its side) orientations, which are the two pre­ferred mounting orientations.
Page 48
40
NL35 Series FC Product Manual, Rev. D

8.3 Cooling

The host enclosure must provide heat removal from the drive. You should confirm that the host enclosure is designed to ensure that the drive operates within the temperature measurement guidelines described in Sec­tion 6.4.1. In some cases, forced airflow may be required to keep temperatures at or below the temperatures specified in Section 6.4.1.
If forced air is necessary, possible air-flow patterns are shown in Figure 7. The air-flow patterns are created by fans either forcing or drawing air as shown in the illustrations. Conduction, convection, or other forced air-flow patterns are acceptable as long as the temperature measurement guidelines of Section 6.4.1 are met.
Above unit
Note. Air flows in the direction shown (back to front) or in reverse direction (front to back)
Note. Air flows in the direction shown or in reverse direction (side to side)
Figure 7. Air flow
Under unit
Above unit
Under unit
Page 49
NL35 Series FC Product Manual, Rev. D
41

8.4 Drive mounting

Mount the drive usi ng the b ottom or side mo unting hol es. If you moun t the d rive u s ing the botto m ho les, ensure that you do not physically distort the drive by attempting to mount it on a stiff, non-flat surface.
The allowable mounting surface stiffness is 80 lb/in (14.0 N/mm). The following equation and paragraph define the allowable mounting surface stiffness:
K x X = F < 15lb = 67N
where K is the mounting surface stiffness (units in lb/in or N/mm) and X is the out-of-plane surface distortion (units in inches or millimeters). The out-of-plane distortion (X) is determined by defining a plane with three of the four mounting points fixed and evaluating the out-of-plane deflection of the fourth mounting point when a known force (F) is applied to the fourth point.
Note. Before mounting the drive in any kind of 3.5-inch to 5.25-inch adapter frame, verify with Seagate
Technology that the drive can meet the shock and vibration specifications given herein while mounted in such an adapter frame. Adapter frames that are available may not have a mechanical structure capable of mounting the drive so that it can meet the shock and vibration specifications listed in this manual.

8.5 Grounding

Signal ground (PCBA) and HDA ground are connected together in the drive and cannot be separated by the user. The equipment in which the drive is mounted is connected directly to the HDA and PCBA with no electri­cally isolating shock mounts. If it is desired for the system chassis to not be connected to the HDA/PCBA ground, the systems integrator or user must provide a nonconductive (electrically isolating) method of mount­ing the drive in the host equipment.
Increased radiated emissions may result if you do not provide the maximum surface area ground connection between system ground and drive ground. This is the system designer’s and integrator’s responsibility.
Page 50
42
NL35 Series FC Product Manual, Rev. D
Page 51
NL35 Series FC Product Manual, Rev. D
43

9.0 Interface requirements

This section partially describes the interface requirements as implemented on NL35 Series drives. Additional information is provided in the Fibre Channel Interface Manual (part number 77767496).

9.1 FC-AL feat ures

This section lists the Fibre Channel-specific features supported by NL35 Series drives.

9.1.1 Fibre Channel link service frames

Table 13 lists the link services supported by NL35 Series drives.
T a ble 13: Link services support ed
Type of frame Link service
Basic link service frames Abort Sequence (ABTS) Basic link service reply frames Basic_Accept (BA_ACC)
Extended link service frames N_Port Login (PLOGI)
Extended link service reply frames Accept (ACC)
Fibre Channel Services Register FC-4 Types (RFT_ID)
Basic_Reject (BA_RJT)
Fabric Login (FLOGI) Logout (LOGO) Process Login (PRLI) Process Logout (PRLO) Read Link Status (RLS)
Fabric Address Notification (FAN) Port Discovery (PDISC) Address Discovery (ADISC)
Third-party Process Logout (TRPLO)
Link Service Reject (LS_RJT)
Page 52
44
NL35 Series FC Product Manual, Rev. D

9.1.2 Fibre Channel task management functions

Table 14 lists the Fibre C hann el S CSI Fibre C han nel P roto col (F C S CSI FCP ) t ask mana geme nt fun cti ons su p­ported.
Table 14: Fibre Channel SCSI FCP task management functions
T ask name Supported
Term inate task Clear ACA Target reset Clear task set Abort task set
No
No Yes Yes Yes

9.1.3 Fibre Channel task management responses

Table 15 lists the FC SCSI FCP response codes returned for task management functions supported.
Table 15: FC SCSI FCP response codes
Function na m e Response c ode
Function complete Function not supported Function reject
00 04 05
Page 53
NL35 Series FC Product Manual, Rev. D
45

9.1.4 Fibre Channel port login

Table 16 identifies the required content of the N_Port Login (PLOGI) payload from an initiator.
T a ble 16: N_Port login (PLOGI) payload
Bytes
0-15 03 00 00 00 XX XX BB BB CF XX FS FS XX XX XX XX Common 16-31 XX XX XX XX PN PN PN PN PN PN PN PN NN NN NN NN 32-35 NN NN NN NN 36-47 XX XX XX XX XX XX XX XX XX XX XX XX Class 1 48-51 XX XX XX XX 52-63 XX XX XX XX XX XX XX XX XX XX XX XX Class 2 64-67 XX XX XX XX 68-79 SO SO IC IC XX XX FS FS XX CS XX XX Class 3 80-83 OS OS XX XX 84-95 XX XX XX XX XX XX XX XX XX XX XX XX Reserved 96-99 XX XX XX XX 100-111 XX XX XX XX XX XX XX XX XX XX XX XX Vendor 112-115 XX XX XX XX Version
X Indicates a four-bit (hex) field is not checked. x Indicates a single bit is not checked. BB BB-Credit. This field is not checked. The FC-AL drive uses BB-Credit of zero (0). CF Common features. This binary field selects the common features requested by the initiator login.
MSB Continuously increasing offset Must = 1
Random relative offset Not checked. Port Login Accept will return a 0—not supported. Valid version level x N_Port/F_Port Must = 0, N_Port Alternate credit model Must = 1 Other bits reserved xxx XX
FS Receive buffer field size. The FS field in the common and Class 3 parameters is checked for the range 128 < FS < 2,112 and a
multiple of four bytes. For multiple frame sequences, all frames but the last frame of the sequence must be this size. Only the receive buffer field size in the Class 3 parameters is used.
PN Port name (initiator’s)—saved with the login parameters. If a change of the port name/AL_PA address association is detected
during a Port DISCovery, and implicit logout occurs and the initiator returns a LS_RJT. NN Node name. The node name is not checked or saved by the drive. SO Service options Class 3 only.
MSB Class valid Must = 1
Intermix x Stacked connection req. xx Sequential delivery x Other bits reserved xxx XX
IC Initiator control
MSB XID reassign xx
Proc Assc 10 or 11 causes the login to be rejected. Other values are accepted.
Other bits XXX CS Concurrent sequences Must be a value greater than 0. OS Open sequences per exchange Must be a value greater than 0.
Page 54
46
NL35 Series FC Product Manual, Rev. D

9.1.5 Fibre Channel port login accept

Table 17 identifies the N_Port Login access payload values.
Table 17: N_Port Login Accept (ACC) payload
Bytes
0-15 02 00 00 00 20 20 00 00 88 00 FS FS 00 FF 00 01 Common 16-31 00 00 01 F4 20 PP 00 20 37 UI UI UI 20 00 00 20 32-35 37 UI UI UI 36-47 00 00 00 00 00 00 00 00 00 00 00 00 Class 1 48-51 00 00 00 00 52-63 00 00 00 00 00 00 00 00 00 00 00 00 Class 2 64-67 00 00 00 00 68-79 80 00 00 00 00 00 FS FS 00 FF 00 00 Class 3 80-83 00 01 00 00 84-95 00 00 00 00 00 00 00 00 00 00 00 00 Reserved 96-99 00 00 00 00 100-111 00 00 00 00 00 00 00 00 00 00 00 00 Vendor ­112-115 00 00 00 00 Version
FS Receive buffer field size. The drive returns and uses the receive buffer size from the N_Port Login Class 3 receive
buffer.
UI U nique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and
Node Name fields.
PP Port identifier field.
01 P_LOGI received on Port A. 02 P_LOGI received on Port B.

9.1.6 Fibre Channel Process Login

Table 18 lists the process login payload data.
Table 18: Process Login (PLRI) payload
Bytes
0-15 20 10 00 14 08 00 20 00 XX XX XX XX XX XX XX XX 16-19 00 00 00 22
XX Indicates fields that are not used.
Page 55
NL35 Series FC Product Manual, Rev. D
47

9.1.7 Fibre Channel Process Login Accept

Table 19 lists NL35 Series process login accept payload data.
Table 19: Process Login Accept (ACC) payload
Bytes
0-15 02 10 00 14 08 00 21 00 00 00 00 00 00 00 00 00 16-31 00 00 00 12

9.1.8 Fibre Channel fabric login

Table 20 lists the fabric login payload from the drive.
Table 20: Fabric Login (FLOGI) payload
Bytes
0-15 04 00 00 00 20 20 00 00 08 00 08 40 00 00 00 00 Common 16-31 00 00 02 F4 20 PP 00 20 37 UI UI UI 02 00 00 20 32-35 37 UI UI UI 36-47 00 00 00 00 00 00 00 00 00 00 00 00 Class 1 48-51 00 00 00 00 52-63 00 00 00 00 00 00 00 00 00 00 00 00 Class 2 64-67 00 00 00 00 68-79 80 00 00 00 00 00 08 40 00 00 00 00 Class 3 80-83 00 00 00 00 84-95 00 00 00 00 00 00 00 00 00 00 00 00 Reserve
96-99 00 00 00 00 100-111 00 00 00 00 00 00 00 00 00 00 00 00 Vendor ­112-115 00 00 00 00 Version
UI Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and Node Name
fields.
PP Port identifier field.
01 FLOGI originated on Port A. 02 FLOGI originated on Port B.
d
Page 56
48
NL35 Series FC Product Manual, Rev. D

9.1.9 Fibre Channel fabric accept login

Table 20 lists the required content of the Fabric Login Accept (ACC) payload from the fabric.
Table 21: Fabric Login Accept (ACC) payload
Bytes
0-15 02 00 00 00 XX XX BB BB CF XX FS FS R_ A_ T0 V_ Common 16-31 E_ D_ T0 V_ PN PN PN PN PN PN PN PN NN NN NN NN 32-35 NN NN NN NN 36-47 XX XX XX XX XX XX XX XX XX XX XX XX Class 1 48-51 XX XX XX XX 52-63 XX XX XX XX XX XX XX XX XX XX XX XX Class 2 64-67 XX XX XX XX 68-79 SO SO xx xx XX XX FS FS XX xx XX XX Class 3 80-83 OS OS XX XX 84-95 XX XX XX XX XX XX XX XX XX XX XX XX Reserve
d 96-99 XX XX XX XX 100-111 XX XX XX XX XX XX XX XX XX XX XX XX Vendor ­112-115 XX XX XX XX Version
X Indicates a four-bit (hex) field is not checked. x Indicates a single bit is not checked. BB BB-Credit. This field is not checked. The FC-AL drive uses BB-Credit of zero (0). CF Common features. This binary field selects the common features requested by the fabric login.
MSB Continuously increasing offset x
Random relative offset x Valid version level x N_Port/F_Port Must = 1, F_Port Alternate credit model Must = 1 Other bits reserved xxx XX
FS Receive buffer field size. The FS field in the common and Class 3 parameters is checked for the range 128 < FS < 2,112 and a
multiple of four bytes. The receive buffer field size in the Class 3 parameters is used. The drive uses the lower FS of Fabric Login Accept or N_Port Login when sending frames to an initiator.
PN Port Name. The fabric port name is saved with the login parameters. If a change of the port name is detected during a FAN, an
implicit logout occurs and a LS_RJT is returned to the fabric. NN Node Name. The drive does not check or save the node name. SO Service Options—Class 3 only.
MSB Class valid Must = 1
Intermix x Stacked connection req. xx Sequential delivery Must = 1 Other bits reserved xxx XX
Page 57
NL35 Series FC Product Manual, Rev. D
49

9.1.10 Fibre Channel Arbitrated Loop options

Table 22 lists the FC-AL options supported by NL35 Series drives.
Table 22: FC-AL options supported
Option Supported
OPEN Half Duplex Accepted from another device. OPEN Full Duplex Sent to open another device.
Private Loop Y es Public Loop Yes Old Port State No Loop Position Yes Loop Position Report Yes
Accepted from another device.

9.2 Dual port support

NL35 Series drives have two independent FC-AL ports. These ports may be connected on independent loops or on the same loop. Port A and Port B may be connected in any order or combination.
• If both ports ar e conn ected on i nde pend ent loo ps and h ard a ddre ssi ng is use d, the driv e in terfa ce add ress i s selected through the interface connector, both ports will seek the same loop address. If no conflict, both ports will have the same loop address.
• If both ports are connected in the same loop and hard addressing is used, at least one port will attempt tak­ing a soft address to prevent an address conflict.
Note. When a NL35 Series drive is connected in loops with previous Seagate FC drive products:
Barracuda 4LP FC (ST32171FC, ST34371FC, and ST34571FC) Barracuda 9FC (ST19171FC) Cheetah 4LP FC (ST34501FC) Cheetah 9FC (ST19101FC)
the connection of Port A and B for these products must follow the requirements in their product manu­als.
Subject to buffer availability, the NL35 Series drives support:
• Concurrent port transfers—The drive supports receiving transfers on both ports at the same time when the ports are on independent loops.
• Full duplex—The drive supports sending FCP_Data, FCP_RSP, FCP_XFR_RDY and ELS transfers while receiving frames on both ports.
Page 58
50
NL35 Series FC Product Manual, Rev. D

9.3 SCSI commands supported

Table 23 lists the SCSI commands supported by NL35 Series drives.
T a bl e 23: Supported com ma nds
Command code Supporte d [ 4 ] Command name
00h 01h 03h
04h 07h 08h 0Ah 0Bh 12h
Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Test unit ready Rezero unit Request sense Extended sense Field pointer bytes Actual retry count bytes Format unit [1] Reassign blocks Read Write Seek Inquiry Vital product data page (00h) Unit serial number page (80h)
15h 16h
17h 18h
Y Y Y Y Y Y Y Y N N Y N
Implemented operating def. page (81h) IDevice identification page (83h) Firmware numbers page (C0h) Date code page (C1h) Jumper settings page (C2h) Device behavior page (C3h) Mode select (same pages as Mode Sense command shown below) [3] Reserve 3rd party reserved Extent reservation Release Copy
Page 59
NL35 Series FC Product Manual, Rev. D
51
T a bl e 23: Supported com ma nds (continued)
Command code Supporte d [ 4 ] Command name
1Ah
1Bh 1Ch
Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Mode sense Unit attention page (00h) Error recovery page (01h) Disconnect/reconnect control (page 02h) Format page (03h) Rigid disc drive geometry page (04h) Verify error recovery page (07h) Caching parameters page (08h) Fibre Channel interface control page (19h) Control mode page (0Ah) Power control page (1Ah) Information exceptions control page (1Ch) Start unit/stop unit Receive diagnostic results
1Dh
25h 28h
2Ah
Y Y Y Y Y Y Y Y Y Y N Y Y Y
Supported diagnostics pages Translate page Enclosure services page Send diagnostics page Supported diagnostics pages Translate page Read capacity Read extended Disable page out Force unit access Relative address Write extended Disable page out Force unit access
Page 60
52
NL35 Series FC Product Manual, Rev. D
T a bl e 23: Supported com ma nds (continued)
Command code Supporte d [ 4 ] Command name
2Bh 2Eh
2Fh
30h 31h 32h 33h
N Y Y Y Y N Y Y Y N N N N N
Relative address Seek extended Write and verify Disable page out Byte check Relative address Verify Disable page out Byte check Relative address Search data high Search data equal Search data low
Set limits 34h 35h 36h 37h 39h 3Ah 3Bh
N Y N Y N N Y Y Y N Y N Y Y
Prefetch
Synchronize cache
Lock-unlock-cache
Read defect data
Compare
Copy and verify
Write buffer
Write combined header and data mode (0)
Write data mode (2)
Download microcode mode (4)
Download microcode and save modes (5)
Download microcode with offsets mode (6)
Download microcode with offsets and save mode (7)
Firmware download option [2]
Page 61
NL35 Series FC Product Manual, Rev. D
53
T a bl e 23: Supported com ma nds (continued)
Command code Supporte d [ 4 ] Command name
3Ch
3Eh 3Fh 40h 41h
42-4Bh 4Ch 4Dh
Y Y Y Y Y Y N Y N N N Y Y Y
Read buffer Read combined header and data mode (0) Read data mode (2) Read descriptor mode (3) Read long Write long Change definition Write same PBdata LBdata Not used Log Select Log Sense Supported Log page (00h)
4E-4Fh 50h 51h 52h
Y Y N Y Y Y N Y Y Y N N N N
Write Error Counter page (02h) Read Error Counter page (03h) Read Reverse Error Counter page (04h) Verify Error Counter page (05h) Non-medium Error Counter page (06h) Temperature page (0Dh) Application Client page (0Fh) Self Test Results page (10h) Cache Statistics Counter page (37h) Factory Log page (3Eh) Not used XD write XP write XD read
Page 62
54
NL35 Series FC Product Manual, Rev. D
T a bl e 23: Supported com ma nds (continued)
Command code Supporte d [ 4 ] Command name
53-54h 55h 56h
57h 58-59h 5Ah 5B-5Dh 5E 5F 60-7Fh 80h 81h
N Y Y Y N Y N Y N A A N N N
Not used
Mode Select (10) [3]
Reserved (10)
3rd party reserve
Extent reservation
Released (10)
Not used
Mode Sense (10) [3]
Not used
Persistent reserve in
Persistent reserve out
Not used
XD write extended
Rebuild 82h 83-8Fh C0-DFh EO-FFh
N N N N
Regenerate
Not used
Not used
Not used
[1] NL35 Series drives can format to 512, 520, 524, and 528 bytes per logical block. [2] Warning. Power loss during flash programming can result in firmware corruption. This usually makes the
drive inoperable. [3] Reference Mode Sense command 1Ah for mode pages supported. [4] Y = Ye s. Command is supported.
N = No. Command is not supported.
A = Support is available on special request.
Page 63
NL35 Series FC Product Manual, Rev. D
55

9.3.1 Inquiry data

Table 24 lists the Inquiry command data that the drive should return to the initiator per the format given in the Fibre Channel Interface Manual.
Table 24: NL35 Series inquiry data
Bytes Data (hex)
0-15 00 00 ** 12 8B 00 PP 0A 53 45 41 47 41 54 45 20 Vendor ID 16-31 [53 54 33 35 30 30 30 37 31 46 43] 20 20 20 20 20 Product ID 32-47 R# R# R# R# S# S# S# S# S# S# S# S# 00 00 00 00 48-63 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 64-79 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 80-95 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 96-111 00 43 6F 70 79 72 69 67 68 74 20 28 63 29 20 32* *Copyright 112-127 30* 30* 36* 20 53 65 61 67 61 74 65 20 41 6C 6C 20 notice 128-143 72 69 67 68 74 73 20 72 65 73 65 72 76 65 64 20
* Copyright year (changes with actual year). ** 02 = SCSI-2 implemented with some SCSI-3 features (default).
03 = The device complies to ANSI X3.301:199x
PP 50 = Inquiry data for an Inquiry command received on Port A.
70 = Inquiry data for an Inquiry command received on Port B. R# Four ASCII digits representing the last four digits of the product firmware release number. S# Eight ASCII digits representing the eight digits of the product serial number. [ ] Bytes 16 through 25 reflect drive model.

9.3.2 Mode Sense data

The Mode Sense command provides a way for the drive to report its operating parameters to the initiator. The drive maintains four sets of mode parameters:
1. Default values
Default values are hard-coded in the drive firmware stored in flash E-PROM (nonvolatile memory) on the drive’s PCB. These default values can be changed only by downloading a complete set of new firmware into the flash E-PROM. An initiator can request and receive from the drive a list of default values and use those in a Mode Select command to set up new current and saved values, where the values are change­able.
2. Saved values
Saved values are stored on the drive’s media using a Mode Select command. Only parameter values that are allowed to be chang ed c an b e cha nged by th i s me thod. Pa ram eters in th e save d va lues l ist that are not changeable by the Mode Select command get their values from default values storage.
When power is applied to the drive, it takes saved values from the media and stores them as current val­ues in volatile memory. It is not possible to change the current values (or the saved values) with a Mode Select command before the drive achieves operating speed and is “ready.” An attempt to do so results in a “Check Condition” status.
On drives requiring unique saved values, the required unique saved values are stored into the saved val­ues storage location on the media prior to shipping the drive. Some drives may have unique firmware with unique default values also.
Page 64
56
NL35 Series FC Product Manual, Rev. D
On standard OEM drives, the saved values are taken from the default values list and store d into the saved values storage location on the media prior to shipping.
3. Current values Current values are volatile values bei ng used by the driv e to contro l its operation. A Mod e S elect comm and
can be used to change the values identified as changeable values. Originally, current values are installed from saved or default values after a power on reset, hard reset, Target Reset, or LIP Reset.
4. Changeable values Changeable values for m a bit mask, stored in no nvolatil e me mor y, that dictates which of the current values
and saved values can be changed by a Mode Select command. A one (1) indicates the value can be changed. A zero (0) indicates the value is not changeable. For example, in Table 25, refer to Mode page 81, in the row entitled “CHG.” These are hex numbers representing the changeable values for Mode page
81. Note in colu mns 5 and 6 ( bytes 0 4 an d 05) , th ere is 00h w hich ind ic ates th at in bytes 0 4 an d 05 none of the bits are changeable. Note also that bytes 06, 07, 09, 10, and 11 are not changeable, because those fields are all zeros. In byte 02 , hex val u e FF equates to the binary p attern 11111111. If there is a zero in any bit position in the field, it means that bit is not changeable. Since all of the bits in byte 02 are ones, all of these bits are changeable.
The changeable values list can only be changed by downloading new firmware into the flash E-PROM.
Note. Because there are often several dif feren t versi on s of dr ive contr ol firm ware in the total population of
drives in the field , the Mode Sense values given in the followi ng ta bles m ay not exactly m atch t hose of some drives.
The following table s list the values of the dat a bytes returned by the drive in response to the Mode Sense com­mand pages for SCSI implementation (see the Fibre Channel Interface Manual ).
Definitions: DEF = Default value. Standard OEM drives are shipped configured this way. CHG = Changeable bits; indicates if default value is changeable.
Page 65
NL35 Series FC Product Manual, Rev. D
57
Table 25: Mode Sense data default and changeable values for ST3500071FC drives
ST3500071FC
Bytes 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Mode Sense Header
DEF 81 0a c0 0b f f 00 00 00 05 00 f f f f
CHG 81 0a f f f f 00 00 00 00 f f 00 f f f f
DEF 82 0e 80 80 00 00 00 00 00 00 0c 9b 00 00 00 00
CHG 82 0e f f f f 00 00 00 00 00 00 f f f f 00 00 00 00
DEF 83 16 14 9e 00 00 00 2b 00 00 03 d7 02 00 00 01 00 e1 00 60 40 00 00 00
CHG 83 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 84 16 01 df 54 08 00 00 00 00 00 00 00 00 00 00 00 00 00 00 1c 22 00 00
CHG 84 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 87 0a 00 0b f f 00 00 00 00 00 f f f f
CHG 87 0a 0f f f 00 00 00 00 00 00 f f f f
DEF 88 12 14 00 f f f f 00 00 f f f f f f f f 00 03 00 00 00 00 00 00
CHG 88 12 b5 00 00 00 f f f f f f f f 00 00 a0 f f 00 00 00 00 00 00
00 ae 00 10 00 00 00 08 3a 35 29 44 00 00 02 00 <-----------------------------Mode Page 16 Byte Header Data and Parameter Data Bytes--------------------------->
DEF 8a 0a 02 00 00 00 00 00 00 00 27 00
CHG 8a 0a 03 f1 00 00 00 00 00 00 00 00
DEF 99 06 00 00 00 00 00 00
CHG 99 06 00 f f 00 00 00 00
DEF 9a 0a 00 02 00 00 00 05 00 00 00 04
CHG 9a 0a 00 03 f f f f f f f f 00 00 00 00
DEF 9c 0a 10 00 00 00 00 00 00 00 00 01
CHG 9c 0a 9d 0f f f f f f f f f f f f f f f f f
DEF 80 06 00 00 0f 00 00 8c
CHG 80 06 b7 40 0f 00 00 f f
<--- Read capacity data --->
3a 35 29 43 00 00 02 00
Page 66
58
NL35 Series FC Product Manual, Rev. D
Table 26: Mode Sense data default and changeable values for ST3400071FC drives
ST3400071FC
Bytes 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Mode Sense Header
DEF 81 0a c0 0b f f 00 00 00 05 00 f f f f
CHG 81 0a f f f f 00 00 00 00 f f 00 f f f f
DEF 82 0e 80 80 00 00 00 00 00 00 0c 9b 00 00 00 00
CHG 82 0e f f f f 00 00 00 00 00 00 f f f f 00 00 00 00
DEF 83 16 13 4b 00 00 00 34 00 00 03 54 02 00 00 01 00 e1 00 60 40 00 00 00
CHG 83 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 84 16 01 bd 5d 08 00 00 00 00 00 00 00 00 00 00 00 00 00 00 1c 22 00 00
CHG 84 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 87 0a 00 0b f f 00 00 00 00 00 f f f f
CHG 87 0a 0f f f 00 00 00 00 00 00 f f f f
DEF 88 12 14 00 f f f f 00 00 f f f f f f f f 00 03 00 00 00 00 00 00
CHG 88 12 b5 00 00 00 f f f f f f f f 00 00 a0 f f 00 00 00 00 00 00
00 ae 00 10 00 00 00 08 2e 90 ed d0 00 00 02 00
<-----------------------------Mode Page 16 Byte Header Data and Parameter Data Bytes--------------------------->
DEF 8a 0a 02 00 00 00 00 00 00 00 21 00
CHG 8a 0a 03 f1 00 00 00 00 00 00 00 00
DEF 99 06 00 00 00 00 00 00
CHG 99 06 00 f f 00 00 00 00
DEF 9a 0a 00 02 00 00 00 05 00 00 00 04
CHG 9a 0a 00 03 f f f f f f f f 00 00 00 00
DEF 9c 0a 10 00 00 00 00 00 00 00 00 01
CHG 9c 0a 9d 0f f f f f f f f f f f f f f f f f
DEF 80 06 00 00 0f 00 00 8c
CHG 80 06 b7 40 0f 00 00 f f
<--- Read capacity data --->
2e 90 ed cf 00 00 02 00
Page 67
NL35 Series FC Product Manual, Rev. D
59

9.4 Miscellaneous operating features and conditions

Table 27 lists various features and conditions. A “Y” in the support column indicates the feature or condition is supported. An “N” in the support column indicates the feature or condition is not supported.
T a ble 27: Miscellaneo us fea tures
Suppor t e d Feature or condition
Y N N N Y N Y Y Y Y N Y
FC-AL selective reset Automatic contingent allegiance Asynchronous event notification Synchronized (locked) spindle operation Segmented caching Zero latency read Queue tagging (up to 64 queue tags supported) Deferred error handling Parameter rounding (controlled by Round bit in Mode Select page 0) Reporting actual retry count in Extended Sense bytes 15, 16, and 17 Adaptive caching SMP = 1 in Mode Select command needed to save RPL and rotational offset bytes
T a ble 28: Miscellaneous st atu s
Supported Status
Y Y Y Y Y Y Y Y N N
Good Check condition Condition met/good Busy Intermediate/good Intermediate/condition met/good Reservation conflict Task set full ACA active ACA active, faulted initiator
Page 68
60
NL35 Series FC Product Manual, Rev. D

9.5 FC-AL physical interface

Port Bypass
Figure 8 shows the location of the J1 Fibre Channel single connection attachment (FC-SCA). Figure 10 pro­vides the dimensions of the FC-SCA.
Details of the physical, electrical, and logical characteristics are provided within this section. The operational aspects of Seagate’s Fibre Channel drives are provided in the Fibre Channel Interface Manual.
Fibre Channel I/O Connector
Figure 8. Physical interface

9.5.1 Physical character istic s

This section defines physical interface connector.
9.5.1.1 Physical description
FIbre Channel drives may be connected in a loop together or with other compatible FC-AL devices. A maxi­mum of 127 devices may have addresses; however, one of the addresses is reserved for a fabric port switch device. This means 126 addresses are available for FC-AL devices. More FC-AL compatible devices may physically reside on the loop, but they will not be functional because they would not be able to obtain valid addresses.
Port bypass circuits (PBCs) allow devices to be inserted into unpopulated locations or removed from the loop with loop operation recovery after a brief interruption. These PBCs are located external to the FC-AL device. Figure 9 shows the relationship between the PBC and FC-AL device.
Circuit
From Previous
Port Bypass
Circuit N–1
Drive N–1
Drive
MUX
Select
SerialInSerial
Drive N
Out
To Next
Drive
Port Bypass
Circuit N+1
Drive N+1
Figure 9. Port bypass circuit physical interconnect
Page 69
NL35 Series FC Product Manual, Rev. D
61

9.5.2 Connector requirements

P
P
s
(1.30 ± 0.16 mm)
Recommended mating SCA part number:
Part description Positions Part number Features
AMP Vertical (SCA sequence) 40 787317-1 Berg 40 71781 Methode 40 512-220-91-101N Molex 40 717431040
The FC-AL SCA device connector is illustrated in Figure 10.
1.618 ± .003 in
(41.1 ± 0.08 mm)
in 20
in 40
.64 in
(16.24 mm)
1.28 in
(32.47 mm)
1.618 ± .003 in
(41.10 ± 0.08 mm)
1.492 ± .009 in
(37.90 ± 0.24 mm)
Mating end Housing
Pin 1
Pin 21
0.264+.007 in –.010 in
(6.71+0.18 mm)
(–0.25 mm)
With polarization With polarization With polarization With polarization
0.197 ± .003 in
(5.00 ± .08 mm)
0.226 in
(6.50 mm)
2 places
min.
0.394 ± .004 in
(10.0 ± 0.10 mm)
0.039 in
(0.75 mm)
min.
0.024 in
(0.60 mm)
0.079 ± .010 in (2.00 ± .25 mm)
min.
(initial point
of contact)
.05 in
(1.27 mm)
Figure 10 . FC-AL SC A de v ice connect or dimensions
typ.
Contact (typ.)
.025 in (0.635 mm)
0.106 ± .010 in
(2.70 ± 0.25 mm)
0.060 ± .010 in
(1.52 ± 0.25 mm)
0.051 ± .006 in
2 place

9.5.3 Electrical description

Fibre Channel drives use the FC-SCA connector for:
• DC power
• FC-AL interface
• Drive select (device identification)
• Option selection
• Enclosure Services interface This 40-pin connector is designed to plug directly into a backpanel. External cables are not required.
Page 70
62
NL35 Series FC Product Manual, Rev. D

9.5.4 Pin descriptions

This section provides a pin-out of the FC-SCA and a description of the functions provided by the pins.
T a bl e 29: FC-SCA pin desc ri ptio ns
Pin Signal name Signal type Pin Signal name Signal type
1* -EN bypass port A Low Voltage
2* 12 Volt s 22 Ground 3* 12 Volt s 23 Ground 4* 12 Volts 24* +Port A_in Diff. PECL input pair 5* -Parallel ESI 25* -Port A_in 6* Ground 7* Active LED out Open collector out 27* +Port B_in Diff. PECL input pair 8* Reserved 28* -Port B_in 9* Start_1 [2] TTL input 29 Ground 10* Start_2 [2] TTL input 30* +Port A_out Diff PECL output pair 11* -EN bypass port B Low Voltage
12* SEL_6 TTL input/output 32 Ground 13* SEL_5 TTL input/output 33* +Port B_out Diff PECL output pair 14* SEL_4 TTL input 34* -Port B_out 15* SEL_3 TTL input/output 35 Ground 16* Fault LED out Open collector out 36 SEL_2 TTL input/output
[1]
TTL output
TTL output
21 12 Volts charge
26 Ground
31* -Port A_out
17* DEV_CTRL_CODE_2
[2]
18* DEV_CTRL_CODE_1
[2] 19* 5 Volts 39 DEV_CTRL_CODE_0 [2] TTL input 20* 5 Volts 40 5 Volts charge
TTL input 37 SEL_1 TTL input/output
TTL input 38 SEL_0 TTL input/output
*Short pins in mating backpanel connector. [1] This pin may be connected to external logic to detect the presence of the drive. The drive connects this
pin to the common ground.
[2] Pins 9, 10, 17 , 18, and 39 are opt io n sele ct pins and are tied high by the drive circuitry. The preferred elec-
trical connection at the backplane is either open or grounded (open for the ‘1’ setting, grounded for the ‘0’ setting). Alternativ ely, these pins may be driven by a 3.3V logic device, pull ed u p to 3.3V thro ugh a pu l l-up resistor (recommended size of 10K ohm), or grounded through some other means.
Page 71
NL35 Series FC Product Manual, Rev. D
63

9.5.5 FC-AL transmitters and receivers

A typical FC-AL differential copper transmitter and receiver pair is shown in Figure 11. The receiver is required to provide the AC coupling to eliminate ground shift noise.
68
TX
Transmitter
TY
150
Figure 11. FC-AL transmitters and receivers
150
68
Differential
Transfer Medium
.01
150
.01
RX
Receiver
RY

9.5.6 Power

Power is supplied through the FC-SCA with support for +5 volts and +12 volts. All of the voltage pins in the drive connector are the same length.
Four 12 volt pins provide +12 volt power to the drive. The current return for the +12 volt power supply is through the common ground pins. The supply current and return current must be distributed as evenly as pos­sible among the pins. The maximum current typically occurs while the drive motor is starting.
Three 5 volt pins pro vide l ogic powe r to the d riv e. Th e curr ent re turn for the +5 vol t p ower sup pl y is th roug h the common ground pins. Distribute supply and return current as evenly as possible among the voltage and ground pins.
The mating connector pins use shorter contacts to achieve power surge reductions and to aid in “hot plugging” the drives. There are longer voltage contacts in the connector to enable the drive filter capacitors to charge. Current to the drive through the long charge pins is limited by the system in which the drive operates. Three of the +12 volt pins ar e shor ter to all ow ca pa citi ve pr e-cha rging throu gh th e longe r + 12 v olt charge pi n . Two of the +5 volt pins are shorter to allow capacitive precharging through the longer +5 volt charge pin.

9.5.7 Fault LED Out

The Fault LED Out signal is driven by the drive when:
• the drive detects failure of both ports
• the drive detects an internal failure
• the drive receives the appropriate fault LED command from the host The Fault LED Out signal is designed to pull down the cathode of an LED. The anode is attached to the proper
+5 volt supply through an appropriate current-limiting resistor. The LED and the current-limiting resistor are external to the drive.
Page 72
64
NL35 Series FC Product Manual, Rev. D

9.5.8 Active LED Out

The Active LED Out signal is driven by the drive as indicated in Table 30.
T a ble 30: Active LED Out condition s
Normal command activity LED status
Spun down and no activity Slow blink (20% on and 80% off a 2 sec cycle) Spun down and activity (command executing) On Spun up and no activity On Spun up and activity (command executing) Off Spinning up or down Blinks steadily (50% on and 50% off) Format in progress, each cylinder change Toggles on/off
The Active LED Out signal is designed to pull down the cathode of an LED. The anode is attached to the proper +5 volt supply through an appropriate current limiting resistor. The LED and the current limiting resistor are external to the drive.

9.5.9 Enable port bypass signals

The – Enable Bypass P ort A (– EN BYP P ort A) an d – En able By p ass Port B (– EN BYP Por t B) si gnals con trol the port bypass circuits (PBC) located external to the disc drive. The PBC allows a loop to remain functional in the event of a drive failure or removal. When these signals are active, low, the PBC bypasses the drive on the associated port. When an Enable Bypass signal is active, the corresponding Port Bypass LED signal in con­nector J1 is driven low by the disc drive. A pull down resistor, 1K, located with the PBC should be used to insure the bypass is enabled if the disc drive is not installed.
The Enable Bypass signal is active under failing conditions within the drive, on detection of the Loop Port Bypass primitive se quen ce, or on r emo val of t he dr ive. In the b yp ass state the drive con tinues t o re ceiv e on the inbound fibre. Enable Bypass may be deactivated by detection of a Loop Port Enable primitive sequence if the drive has completed self-test and a hardware failure is not present.
Failure modes detected by the disc drive that will enable bypass include:
• Transmitter/receiver wrap test failure
• Loss of receive clock
• Loss of transmission clock
• Drive interface hardware error
Page 73
NL35 Series FC Product Manual, Rev. D
65

9.5.10 Motor start controls

The drive’s motor is started according to the Start_1 and Start_2 signals described in Table 31. The state of these signals can be wired into the backplane socket or driven by logic on the backplane.
T a ble 31: Motor start control sign als
Case Start_2 Start_1 Motor spin function
1 Low Low Motor spins up at DC power on. 2 High Low Motor spins up only when SCSI Start command is received. 3 Low High Motor spins up after a delay of 12 seconds times the modulo 8 value of
4 High High The drive will not spin up.
the numeric SEL ID of the drive from DC power on.

9.5.11 SEL_6 through SEL_0 ID lines

The SEL_6 through SEL_0 ID lines determine drive address, and, optionally, for an Enclosure Services Inter­face. When the Parallel ESI line is hig h, the en closure backp anel must provide address info rma tion on th e SEL line. Refer to table 32 for a mapping of SEL to FC-AL physical addresses (AL_PA). You can think of the SEL lines as the equivalent of a backpanel logic plug. The drives does not provide pull up resistors on these lines. The backpanel is required to provide high and low inputs to the SEL_ID lines per the specifications in table 34 on page 67.
Note. Table 32 gives AL_PA values for each SEL value. The first entry in the table is SEL_ID 00. The last
entry is SEL_ID 7D. SEL_ID 7E is AL_PA 00 which is not valid for an NL_Port, so is not included in the table. Also, SEL_ID 7Fh does map to a valid AL_PA; however, this value signals the drive that physical addresses are not being assigned using the SEL lines and that a “soft” address will be determined by FC-AL loop initialization.
When the Parallel ESI line is low, the enclosure backpanel logic switches to ESI mode if supported. There are two modes of ESI, seven bits of enclosure status and a bidirectional mode. ESI support and the mode are determined by the drive using a discovery process. Refer to the Fibre Channel Interface Manual for a descrip- tion of ESI operation.
9.5.1 1.1 Parallel Enclosure Services Interface (ESI)
The parallel ESI line is an output from the drive. This line provides the enclosure with an indication of the present function of the SEL lines. A high level, the default state, indicates the drive requires address informa­tion on the SEL lines. A low level indicates the drive is attempting an ESI transfer. The enclosure may not sup­port ESI on any or all drive locations. It may only suppo rt the address functi on . Support of ESI is discovered by the drive. Refer to the Fibre Channel Interface Manual for a description of ESI operations.
Page 74
66
NL35 Series FC Product Manual, Rev. D
Table 32: Arbitrated loop physical address (AL_PA) values
AL_PA (hex)
EF 00 00 A3 2B 43 4D 56 86 E8 01 01 9F 2C 44 4C 57 87 E4 02 02 9E 2D 45 4B 58 88 E2 03 03 9D 2E 46 4A 59 89 E1 04 04 9B 2F 47 49 5A 90 E0 05 05 98 30 48 47 5B 91 DC 06 06 97 31 49 46 5C 92 DA 07 07 90 32 50 45 5D 93 D9 08 08 8F 33 51 43 5E 94 D6 09 09 88 34 52 3c 5F 95 D5 0A 10 84 35 53 3A 60 96 D4 0B 11 82 36 54 39 61 97 D3 0C 12 81 37 55 36 62 98 D2 0D 13 80 38 56 35 63 99 D1 0E 14 7C 39 57 34 64 100 CE 0F 15 7A 3A 58 33 65 101 CD 10 16 79 3B 59 32 66 102
SEL ID (hex)
Setting (dec)
AL_PA (hex)
SEL ID (hex)
Setting (dec)
AL_PA (hex)
SEL ID (hex)
Setting (dec)
CC 11 17 76 3C 60 31 67 103 CB 12 18 75 3D 61 2E 68 104 CA 13 19 74 3E 62 2D 69 105 C9 14 20 73 3F 63 2C 6A 106 C7 15 21 72 40 64 2B 6B 107 C6 16 22 71 41 65 2A 6C 108 C5 17 23 6E 42 66 29 6D 109 C3 18 24 6D 43 67 27 6E 110 BC 19 25 6C 44 68 26 6F 111 BA 1A 26 6B 45 69 25 70 112 B9 1B 27 6A 46 70 23 71 113 B6 1C 28 69 47 71 1F 72 114 B5 1D 29 67 48 72 1E 73 115 B4 1E 30 66 49 73 1D 74 116 B3 1F 31 65 4A 74 1B 75 117 B2 20 32 63 4B 75 18 76 118 B1 21 33 5C 4C 76 17 77 119 AE 22 34 5A 4D 77 10 78 120 AD 23 35 59 4E 78 0F 79 121 AC 24 36 56 4F 79 08 7A 122
Page 75
NL35 Series FC Product Manual, Rev. D
67

9.5.12 Device control codes

The drive inputs a Device Control Code on the DEV_CTRL_CODE lines at power up to determine the link rate on the Fibre Channel ports. Both ports run at the same rate. If the backpanel does not connect to these lines, the drive has 10K ohm pull up resistors that default the device control code to 7 (1.0625 GHz). Table 33 lists the supported codes.
Table 33: Device control code values
2 (pin 17) 1 (pin 18) 0 (pin 39) Definition
0 0 0 0 1 1 1 1
0 0 1 1 0 0 1 1
0 Reserved for Power failure warning. 1 Reserved for auto negotiation of link rate. 0 Reserved. 1 Reserved. 0 Reserved. 1 Reserved. 0 2.125 GHz operation on both ports. 1 1.0625 GHz operation on both ports.

9.6 Signal characteristics

This section describes the electrical signal characteristics of the drive’s input and output signals. See Table 29 on page 62 for signal type and signal name information.

9.6.1 TTL input characteristics

Table 34 provides the TTL characteristics.
T a ble 34: TTL characteristics
State Voltage Current
Input high 1.9 < VIH < 5.5V IIH = ±500nA max. Input low -0.5V < VIL < 0.9V IOL = ±500nA max. Output high (-EN Bypass A, B) 2.4 < V Output low (-EN Bypass A, B) VOL < 0.5V IOL < 3mA Output high (-Parallel ESI) 2.4 < V
VOH > 0.9V Output low (-Parallel ESI) 0 < VOL < .45V IOL < 2.4mA Output high (all other outputs) 2.4 < V
VOH > 0.9V Output low (all other outputs) 0 < VOL < .45V IOL < 1.6mA
< 5.25V IOH < -3mA
OH
< 0.9 V
OH
< 0.9 V
OH
CC
CC
CC
CC
IOH < -2.4mA I
< -500µA
OH
IOH < -1.6mA I
< -500µA
OH
Page 76
68
NL35 Series FC Product Manual, Rev. D

9.6.2 LED driver signals

Fault and Active LED signals are located in the FC-SCA conne ctor (J1) . See Table 35 for the output character­istics of the LED drive signals.
Table 35: LED drive signal
State Current drive available Output voltage
LED off, high 0 < IOH < 100µA LED on, low IOL < -30 mA 0 < VOL < 0.8V

9.6.3 Differential PECL output

The serial PECL outp ut signa l vol t age c hara cteri stics a re p rovided i n Table 36. The outp ut s are not A C cou pled in order to deliver maximum signal without rise and fall time degradation. You must AC couple the receiver to isolate potentially different DC characteristics of the outputs and the receiver.
Table 36: Differential PECL output characteristics
Description Parameter
Serial output voltage swing 600 < V
< 1300 mV
out
Figure 12 provide s the data o utput valid eye diagram relative to the bit cell time. Table 38 lists the data values.
Bit Time
Vout (mv)
XMIT Eye
Figure 12. Transmit eye diagram

9.6.4 Differential PECL input

The serial PECL input signal voltage characteristics are provided in Table 37.
Table 37: Differential PECL input characteristics
Description Parameter Notes
Serial input voltage swing 400 < Vin < 2.000 mV AC coupled
Page 77
NL35 Series FC Product Manual, Rev. D
69
Figure 13 provides the data valid eye diagram for typical and minimum requirements to recover data at the specified interface error rate. The inputs are AC coupled on the drive. Table 38 lists the data values.
Bit Time
Vin (mv)
RCV Eye
(typical)
(minimum)
Figure 13. Receive eye diagram
Table 38: Eye diagram data values
Link rate 1 GHz 2 GHz
Bit time 941 ps 470 ps XMIT eye 725 ps min. 315 ps min.
RCV eye
Typical 659 ps 305 ps Minimum 395 ps 226 ps
Page 78
70
NL35 Series FC Product Manual, Rev. D
Page 79
NL35 Series FC Product Manual, Rev. D
71

10.0 Seagate Technology support services

Internet
For information regarding Seagate products and services, visit www.seagate.com. Worldwide support is available 24 hours daily by email for your questions.
Presales Support:
T e chn i cal Supp or t:
Warranty Support:
http://www.seagate.com/support/service/index.html
mySeagate
my.seagate.com is the industry's first Web portal designed specifically for OEMs and distributors. It provides self-service access to critical applications, personalized content and the tools that allow our partners to manage their Seagate account functions. Submit pricing requests, orders and returns through a single, password-protected Web interface-anytime, anywhere in the world.
spp.seagate.com
spp.seagate.com supports Seagate resellers with product information, program benefits and sales tools. You may register for customiz e d communi cation s that ar e not ava ila ble on the web. The s e communi catio ns cont ai n product launch, EOL, pricing, promotions and other channel-related information. To learn more about the benefits or to register, go to spp.seagate.com, any time, from anywhere in the world.
Seagate Service Centers
Presales Support
Our Presales Support staff can help you determine which Seagate products are best suited for your specific application or computer system, as well as product availability and compatibility.
Technical Support
Seagate technical support is available to assist you online at support.seagate.com or through one of our call centers. Have your system configuration information and your “ST” model number available.
SeaTDD™ (+1-405-324-3655) is a telecommunications device for the deaf (TDD). You can send questions or comments 24 hours daily and exchange messages with a technical support specialist during normal business hours for the call center in your region.
Page 80
72
NL35 Series FC Product Manual, Rev. D
Customer Service Operations
Warranty Service
Seagate offer s worldwi de custom er supp ort for Seagate pro duct s . Seagate distr i butors, OEM s and other direct customers should contact their Seagate Customer Service Operations (CSO) representative for warranty­related issues. Resellers or end users of drive products should contact their place of purchase or Seagate warranty service for assistance. Have your serial number and model or part number available.
Data Recove ry Service s
Seagate offers data recovery services for all formats and all brands of storage media. Our data recovery services labs are currently located throughout the world. . Additional information, including an online request form and data loss prevention resources, is available at http://services.seagate.com/index.aspx
Authorized Service Centers
Seagate Service Centers are available on a global basis for the return of defective products. Contact your customer support representative for the location nearest you.
USA/Canada/Latin America support services
For an extensive list of telephone numbers to technical support, presales and warranty service in USA/ Canada/Latin America, including business hours, go to the "Contact Us" page on www.seagate.com.
Global Customer Support
Presales, Technical, and Warranty Support Call Center Toll-free Direct dial
USA, Canada, and Mexico 1-800-SEAGATE +1-405-324-4700
Data Recovery Services Call Center Toll-free Direct dial FAX
USA, Canada, 1-800-475-01435 +1-905-474-2162 1-800-475-0158 and Mexico +1-905-474-2459
Europe, the Middle East and Africa Support Services
For an extensive list of telephone numbers to technical support, presales and warranty service in Europe, the Middle East and Africa, go to the "Contact Us" page on www.seagate.com.
Asia/Pacific Support Services
For an extensive list of telephone numbers to technical support, presales and warranty service in Asia/Pacific, go to the "Contact Us" page on www.seagate.com.
Page 81
NL35 Series FC Product Manual, Rev. D
73
Index
Numerics
12 volt
pins 63 3rd party reserve command 54 5 volt pins 63
BB-Credit 45, 48 buffer
data 8
space 13 busy status 59 bypass circuit 19 Byte check command 52 bytes per surface 11 bytes per track 11
A
Abort Sequence (ABTS) 43 abort task set function 44 AC coupling 63 AC power requirements 25 ACA active status 59 ACA active, faulted initiator status 59 Accept (ACC) 43 access time 11 acoustics 32 active LED Out signal 64 Actual retry count bytes command 50 actuator 9
assembly design 7 adaptive caching 59 Address Discovery (ADISC) 43 addresses 60 air cleanliness 31 air flow 40
illustrated 40 Alternate credit model 45, 48 altitude 28 ambient 28 ANSI documents
fibre channel 5
SCSI 5 arbitrated loop physical address (AL_PA) 39 arbitration 39 asynchronous event notification 59 audible noise 3 Australia/New Zealand Standard 4 auto write and read reallocation
programmable 8 automatic contingent allegiance 59 automatic shipping lock 7 average idle current 25 average rotational latency 11
B
backpanel 61 backplane 65 basic link service frames 43 Basic_Accept (BA_ACC) 43 Basic_Reject (BA_RJT) 43 BB 45, 48
C
cache operation 13 cache segments 14 Caching parameters page (08h) command 51 caching write data 14 Canadian Department of Communications 3 capacity
unformatted 11 capacity, drive, programmable 10 CF 45, 48 Change definition command 53 character sync 19 charge pins 63 check condition status 59 Class 3 parameters 45, 48 class B limit 3 Class valid 45, 48 clear ACA function 44 clear task set function 44 command descriptor block (CDB) 12 commands supported 50 Common features 45, 48 Compare command 52 Concurrent sequences 45 condensation 28 condition met/good status 59 connect/disconnect 12 connector
illustrated 61
requirements 61 continuous vibration 31 Continuously increasing offset 45, 48 Control mode page (0Ah) command 51 controller overhead 11 cooling 40 Copy and verify command 52 Copy command 50 CRC 19
error 18 CS 45 customer service 24
D
data block size
Page 82
74
NL35 Series FC Product Manual, Rev. D
modifing the 9
data heads
read/write 11
data rate
internal 11 data transfer rate 12 data valid eye 69 Date code page command 50 DC power 61
requirements 25 dedicated landing zone 7 defect and error management 35 deferred error handling 59 description 7 DEV_CTRL_CODE 67 device behavior page command 50 device control code values 67 device control codes 67 device identification page command 50 device selection IDs 39 devices 39 differential PECL input 68 dimensions 33 Disable page out command 51, 52 disc media 12 disc rotation speed 11 Disconnect/reconnect control (page 02h) command
51
Download microcode and save modes (5) 52 Download microcode mode (4) 52 Download microcode with offsets and save mode (7)
52
Download microcode with offsets mode (6) 52 drive 31 drive capacity
programmable 10 drive characteristics 11 drive failure 19 drive ID 39 drive ID/option select headers 39 drive malfunction 19 drive mounting 33, 41 drive orientation 39 drive select 61 driver signals 68 drivers and receivers 8 dual port support 49
E
electrical
description of connector 61
signal characteristics 67
specifications 25 electromagnetic compatibility 3 electromagnetic susceptibility 32
EMI requirements 3 enable bypass
port A 64 port B 64 signal 64
state 19 Enclosure Services interface 61 Enclosure services page command 51 environmental
limits 28
requirements 17 environmental contro l 31 error
detection mechanisms, FC 19
management 35
rates 17 error correction code
96-bit Reed-Solomon 8 Error recovery page (01h) command 51 execution time 12 extended link service
frames 43
reply frames 43 Extended sense command 50 Extent reservation command 54
F
fabric 48 Fabric Address Notification (FAN) 43 Fabric Login (FLOGI) 43 FAN 48 fault LED out signal 63 FC-AL
document 5
interface 39, 61
options supported 49
physical interface 60
SCA device connector, illustrated 61
selective reset 59 FCC rules and regulations 3 FCP
for SCSI, document 5
response codes 44
task management functions 44 FC-PH document 5 features 8
interface 43 Fibre Channel documents 5 Fibre Channel interface control page 51 Fibre Channel Interface Manual 1, 5 Fibre Channel Services 43 Field pointer bytes command 50 firmware 8
corruption 54 Firmware download option command 52
Page 83
NL35 Series FC Product Manual, Rev. D
75
Firmware numbers page command 50 flawed sector reallocation 8 FLOGI
received on Port A 47
received on Port B 47 Force unit access command 51 form factor 8 format 39 Format command execution time 11 Format page (03h) command 51 Format unit command 50 front panel 33 FS 45, 46, 48 function
complete, code 00 44
not supported, code 05 44
reject, code 04 44
G
Good status 59 gradient 28 ground shift noise 63 grounding 41
H
hard assigned arbitrated loop physical address
(AL_PA) 39
HDA 41 heads
read/write data 11 heat removal 40 host equipment 41 hot plugging the drive 19 humidity 28 humidity limits 28
I
IC 45 ID and configuration options 8 Implemented operating def. page command 50 Information exceptions control page (1Ch) command
51
Initiator control 45 Inquiry command 50 inquiry data 55 installation 39
guide 5 interface 39
commands supported 50
description 60
error rate 17
errors 18
illustrated 60
physical 60
requirements 43 interleave 8 intermediate/condition met/good status 59 intermediate/good status 59 Intermix 45, 48 internal data rate 11 internal defects/errors 35 internal drive characteristics 11
J
J1 connector 39 Jumper settings page command 50 jumpers 39
L
latency
average rotational 11, 12 LBdata 53 LED driver signals 68 link rate 67 Link Service Reject (LS_RJT) 43 link services supported 43 Lock-unlock-cache command 52 Log select command 53 Log sense command 53 logic power 63 logical block address 13 logical block reallocation scheme 8 logical block size 8, 12 logical segments 13 Logout (LOGO) 43 loop 60, 64
disruption 19
initialization 39 loop position
FC-AL options 49 loop position report
FC-AL options 49 LS_RJT 45, 48 LSI circuitry 9
M
maintenance 17 maximum delayed motor start 25 maximum start current 25 Mean Time Between Failure 19 media description 9 miscellaneous feature support
Adaptive caching 59
Asynchronous event notification 59
Automatic contingent allegiance 59
Deferred error handling 59
FC-AL selective reset 59
Parameter rounding 59
Page 84
76
NL35 Series FC Product Manual, Rev. D
Queue tagging 59 Reporting actual retry count 59 Segmented caching 59 SMP = 1 in Mode Select command 59 Synchronized (locked) spindle operation 59 Zero latency read 59
miscellaneous status support
ACA active 59 ACA active, faulted initiator 59 Busy 59 Check condition 59 Condition met/good 59 Good 59 Intermediate/condition met/good 59 Intermediate/good 59 Reservation conflict 59 Task set full 59
miscorrected media data 17 Mode select
(10) command 54 command 50
Mode sense
(10) command 54 command 51 data, table 55, 57, 58
monitoring state 19 motor start
controls 65 option 13
mounting 41
holes 41
orientations 39 mounting configuration 33 mounting configuration dimensions 33 MTBF 19
N
N_Port Login (PLOGI) 43
payload 45
payload values 46 NN 45, 48 Node Name 48 Node name 45 noise
audible 3 noise immunity 26 non-operating 28, 29, 31
temperature 28 non-operating vibration 31
O
office environment 31 old port state
FC-AL options 49
OPEN Full Duplex
FC-AL options 49
OPEN half duplex
FC-AL options 49 Open sequences per exchange 45 operating 28, 29, 31 operating environment 19 option configurations 39 option selection 61 options 10, 49 orientation 12 OS 45 out-of-plane distortion 41 overhead time
for head switch 12
for one track cylinder switch 12
P
P_LOGI
received on Port A 46
received on Port B 46 package size 29 package test specification 5 packaged 29 parameter rounding 59 pass-through state 19 PBC 60, 64 PBdata 53 PCBA 41 peak bits per inch 11 peak operating current 25 PECL input 68 performance characteristics
detailed 11 performance degradation 29 performance highlights 9 physical damage 31 physical interface 60
description 60 physical specifications 25 PI 46, 47 pin descriptions 62 PN 45, 48 port bypass circuit 19, 60, 64 Port DISCovery 45 Port Discovery (PDISC) 43 port identifier field 46, 47 port login 45
accept 46 Port Name 48 Port name (initiator’s) 45 power 63
dissipation 27
requirements, AC 25
requirements, DC 25
Page 85
NL35 Series FC Product Manual, Rev. D
77
sequencing 26 power connector 26 Power control page (1Ah) command 51 power distribution 3 power-on operating hours 19 power-up hours 19 Prefetch command 52 prefetch/multi-segme nted cache control 13 preventive maintenance 17 private loop
FC-AL options 49 Proc Assc 45 Process Accept (ACC) 47 Process Login (PRLI) 43, 46 Process Login Accept (ACC) payload 47 process login payload data 46 Process Logout (PRLO) 43 programmable drive capacity 10 public loop
FC-AL options 49 pull down resistor 64
Register FC-4 Types (RFT_ID) 43 Relative address command 51, 52 relative humidity 28 Release command 50 Released (10) command 54 reliability 9
specifications 17 reliability and service 18 repair and return information 24 reporting actual retry count 59 Request sense command 50 reservation conflict status 59 Reserve command 50 Reserved (10) command 54 resonance 29 return information 24 Rezero unit command 50 Rigid disc drive geometry page
command 51 rotation speed 11 running disparity 19
Q
queue tagging 59
R
radio interference regulations 3 Random relative offset 45, 48 RCD bit 13 Read buffer command 53 Read capacity command 51 Read combined header and data mode (0) 53 Read command 50 Read data mode (2) 53 Read defect data command 52 Read descriptor mode (3) 53 read error rates 17 Read extended command 51 Read Link Status (RLS) 43 Read long command 53 read/write data heads 11 Reassign blocks command 50 Receive buffer field size 45, 48 receive buffer field size 46 Receive diagnostic results command 51 receive eye
diagram 69 receivers 63 recommended mounting 30 Recoverable Errors 18 recovered media data 17 reference
documents 5 Regenerate command 54
S
safety 3 SCA part numbers 61 SCSI interface
commands supported 50
SCSI Interface Product Manual 3 Search data
equal command 52 high command 52
low command 52 sector interleave 12 Seek command 50 seek error
defined 18
rate 17 Seek extended command 52 seek performance characteristics 11 segmented caching 59 SEL ID 39
lines 65
standard feature 8 Self-Monitoring Analysis and Reporting Technology
9, 20 Send diagnostics page command 51 Sequential delivery 45, 48 service
life 17 Service Options 48 Service options 45 Set limits command 52 shielding 3 shipping 24 shipping container 28
Page 86
78
NL35 Series FC Product Manual, Rev. D
shock 29
and vibration 29
shock mount 41 signal
characteristics 67
LED driver 68 single-unit shipping pack kit 10 SMART 9, 20 SMP = 1 in Mode Select command 59 SO 45, 48 spindle brake 8 Stacked connection req. 45, 48 standards 3 Start unit/stop unit command 51 start/stop time 13 support services 71 Supported diagnostics pages command 51 surface stiffness
allowable for non-flat surface 41 switches 39 Synchronize cache command 52 synchronized spindle
operation 59 system chassis 41
T
target reset function 44 task management functions 44
Abort task set 44
Clear ACA 44
Clear task set 44
Target reset 44
terminate task 44 task management response codes 44
Function complete 00 44
Function not supported 05 44
Function reject 04 44 task set full status 59 technical support services 71 temperature 12, 21, 28, 40
limits 28
non-operating 28
regulation 3
See also cooling temperature sensor 21 terminate task function 44 terminators 39 Test unit ready command 50 thermal monitor 21 Third-party Process Logout (TRPLO) 43 tracks per inch 11 tracks per surface 11 Translate page command 51 transmit eye diagram 68 transmitters 63
transporting the drive 24 TTL input characteristics 67 typical access time 12
U
UI 46, 47 unformatted 9 unique identifier 46, 47 Unit attention page (00h) command 51 Unit serial number page command 50 Unrecoverable Errors 18 unrecovered media data 17
V
Valid version level 45, 48 Verify command 52 Verify error recovery page (07h) command 51 vibration 29, 31 Vital product data page command 50 voltage 12
W
warranty 24 word sync 19 Write and verify command 52 Write buffer command 52 Write combined header and data mode (0) 52 Write command 50 Write data mode (2) 52 Write extended command 51 Write long command 53 Write same command 53
X
XD read 53 XD write 53 XD write extended command 54 XID reassign 45 XP write 53
Z
zero latency read 59 zone bit recording (ZBR) 8
Page 87
Page 88
Seagate Technology LLC 920 Disc Drive, Scotts Valley, California 95066-4544, USA
Publication Number: 100343673, Rev. D, Printed in USA
Loading...