Seagate ST3450857FC, ST3450657FC, ST3300657FC, ST336706LC, ST3450757FC User Manual

...
Product Manual
Cheetah 15K.7 FC
Standard models
ST3600057FC
ST3450857FC
ST3300657FC
Self-Encrypting Drive models
ST3600957FC
ST3450757FC
ST3300557FC
ST3600857FC
ST3450657FC
ST3300457FC
100516225
Rev. E
December 2012
© 2012 Seagate Technology LLC. All rights reserved.
Publication number: 100516225, Rev. E December 2012
Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. Cheetah and SeaTools are either trademarks or registered trademarks of Seagate Technology LLC or one of its affiliated companies in the United States and/or other countries. The FIPS logo is a certification mark of NIST, which does not imply product endorsement by NIST, the U.S., or Canadian governments.All other trademarks or registered trademarks are the property of their respective owners.
No part of this publication may be reproduced in any form without written permission of Seagate Technology LLC. Call 877-PUB-TEK1 (877-782-8351) to request permission.
When referring to drive capacity, one gigabyte, or GB, equals one billion bytes and one terabyte, or TB, equals one trillion bytes. Your computer’s operating system may use a different standard of measurement and report a lower capacity. In addition, some of the listed capacity is used for formatting and other functions, and thus will not be available for data storage. Actual quantities will vary based on various factors, including file size, file format, features and application software. Actual data rates may vary depending on operating environment and other factors. The export or re-export of hardware or software containing encryption may be regulated by the U.S. Department of Commerce, Bureau of Industry and Security (for more information, visit www.bis.doc.gov), and controlled for import and use outside of the U.S. Seagate reserves the right to change, without notice, product offerings or specifications.
CONTENTS
SEAGATE® TECHNOLOGY SUPPORT SERVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.0 SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.0 APPLICABLE STANDARDS AND REFERENCE DOCUMENTATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 STANDARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1.1 Electromagnetic compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1.2 Electromagnetic compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 EUROPEAN UNION RESTRICTION OF HAZARDOUS SUBSTANCES (ROHS) . . . . . . . . . . . . . . . . . 4
2.3 REFERENCE DOCUMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.0 GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.1 STANDARD FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 MEDIA DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.3 PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.4 RELIABILITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.5 FORMATTED CAPACITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.5.1 Programmable drive capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.6 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.7 USER-INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.0 PERFORMANCE CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.1 INTERNAL DRIVE CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2 SEEK PERFORMANCE CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2.1 Access time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2.2 Format command execution time (minutes). . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2.3 General performance characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.3 START/STOP TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.4 PREFETCH/MULTI-SEGMENTED CACHE CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.5 CACHE OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.5.1 Caching write data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.5.2 Prefetch operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.0 RELIABILITY SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.1 ERROR RATES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.1.1 Recoverable Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.1.2 Unrecoverable Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.1.3 Seek errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.1.4 Interface errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.2 RELIABILITY AND SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.2.1 Annualized Failure Rate (AFR) and Mean Time Between Failures (MTBF) . . . 15
5.2.2 Preventive maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.2.3 Hot plugging the drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.2.4 S.M.A.R.T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.2.5 Thermal monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.2.6 Drive Self Test (DST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.2.7 Product warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.0 PHYSICAL/ELECTRICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.1 AC POWER REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.2 DC POWER REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6.2.1 Conducted noise immunity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E I
CONTENTS
6.2.2 Power sequencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.2.3 Current profiles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.3 POWER DISSIPATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.4 ENVIRONMENTAL LIMITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.4.1 Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.4.2 Relative humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.4.3 Effective altitude (sea level) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6.4.4 Shock and vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
6.4.5 Acoustics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.4.6 Air cleanliness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.4.7 Corrosive environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.4.8 Electromagnetic susceptibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
6.5 MECHANICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7.0 ABOUT FIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
8.0 ABOUT SELF-ENCRYPTING DRIVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.1 DATA ENCRYPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.2 CONTROLLED ACCESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.2.1 Admin SP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.2.2 Locking SP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.2.3 Default password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.3 RANDOM NUMBER GENERATOR (RNG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.4 DRIVE LOCKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.5 DATA BANDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.6 CRYPTOGRAPHIC ERASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.7 AUTHENTICATED FIRMWARE DOWNLOAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.8 POWER REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8.9 SUPPORTED COMMANDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
9.0 DEFECT AND ERROR MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
9.1 DRIVE INTERNAL DEFECTS/ERRORS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
9.2 DRIVE ERROR RECOVERY PROCEDURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
9.3 FC-AL SYSTEM ERRORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
9.4 BACKGROUND MEDIA SCAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.5 MEDIA PRE-SCAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.6 DEFERRED AUTO-REALLOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
9.7 IDLE READ AFTER WRITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
10.0 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
10.1 DRIVE ID/OPTION SELECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
10.2 DRIVE ORIENTATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
10.3 COOLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
10.4 DRIVE MOUNTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
10.5 GROUNDING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
11.0 INTERFACE REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
11.1 FC-AL FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
11.1.1 Fibre Channel link service frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
11.1.2 Fibre Channel task management functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
11.1.3 Fibre Channel task management responses . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
11.1.4 Fibre Channel port login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
11.1.5 Fibre Channel port login accept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
11.1.6 Fibre Channel Process Login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E II
CONTENTS
11.1.7 Fibre Channel Process Login Accept. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
11.1.8 Fibre Channel fabric login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
11.1.9 Fibre Channel fabric accept login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
11.1.10 Fibre Channel Arbitrated Loop options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
11.2 DUAL PORT SUPPORT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
11.3 SCSI COMMANDS SUPPORTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
11.3.1 Inquiry data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
11.3.2 Mode Sense data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
11.4 MISCELLANEOUS OPERATING FEATURES AND CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
11.5 FC-AL PHYSICAL INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
11.5.1 Physical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
11.5.2 Connector requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
11.5.3 Electrical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
11.5.4 Pin descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
11.5.5 FC-AL transmitters and receivers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
11.5.6 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
11.5.7 Fault LED Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
11.5.8 Active LED Out. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
11.5.9 Enable port bypass signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
11.5.10 Motor start controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
11.5.11 SEL_6 through SEL_0 ID lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
11.5.12 Device control codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
11.6 SIGNAL CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
11.6.1 TTL input characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
11.6.2 LED driver signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
11.6.3 FC Differential output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
11.6.4 FC Differential input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E III
Seagate® Technology Support Services
For information regarding online support and services, visit
Available services include:
Presales & Technical support
Global Support Services telephone numbers & business hours
Authorized Service Centers
For information regarding Warranty Support, visit
For information regarding data recovery services, visit
For Seagate OEM and Distribution partner portal, visit
For Seagate reseller portal, visit
http://spp.seagate.com
http://www.seagate.com/support/warranty-and-returns/
http://www.seagate.com/www/en-us/about/contact_us/
http://www.seagate.com/services-software/data-recovery-services/
https://direct.seagate.com/portal/system
Cheetah 15K.7 FC Product Manual, Rev. E 1

1.0 SCOPE

This manual describes Seagate Technology® LLC, Cheetah® 15K.7 FC (Fibre Channel) disk drives.
Cheetah 15K.7 FC drives support the Fibre Channel Arbitrated Loop and SCSI Fibre Channel Protocol specifications to the
extent described in this manual. The Fibre Channel Interface Manual (part number 100293070) describes the general Fibre
Channel Arbitrated Loop characteristics of this and other Seagate Fibre Channel drives. The Self-Encrypting Drive (SED) Users Guide, part number 100515636 describes the interface, general operation and security features available on SED drives.
From this point on in this product manual, the reference to Cheetah 15K.7 FC models is referred to as “the drive” unless references to individuals models are necessary.
Unless otherwise stated, the information in this manual applies to standard and Self-Encrypting Drive models.
ODEL NUMBER CAPACITY SELF-ENCRYPTING DRIVE (SED) FIPS 140-2 LEVEL 2 CERTIFIED
M
ST3600057FC 600 GB No No
ST3450857FC 450 GB No No
ST3300657FC 300 GB No No
ST3600957FC 600 GB Yes No
ST3600857FC 600 GB Yes Yes
ST3450757FC 450 GB Yes No
ST3450657FC 450 GB Yes Yes
ST3300557FC 300 GB Yes No
ST3300457FC 300 GB Yes Yes
Note. Previous generations of Seagate Self-Encrypting Drive models were called Full Disk Encryption (FDE) models
before a differentiation between drive-based encryption and other forms of encryption was necessary.
Note. The Self-Encrypting Drive models indicated on the cover of this product manual have provisions for “Security of
Data at Rest” based on the standards defined by the Trusted Computing Group (see www.trustedcomputing­group.org).
For more information on FIPS 140-2 Level 2 certification see Section 7.0 on page 31.
For product certification status visit - http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/1401vend.htm.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 2

2.0 APPLICABLE STANDARDS AND REFERENCE DOCUMENTATION

The drive has been developed as a system peripheral to the highest standards of design and construction. The drive depends upon its host equipment to provide adequate power and environment in order to achieve optimum performance and compliance with applicable industry and governmental regulations. Special attention must be given in the areas of safety, power distribution, shielding, audible noise control, and temperature regulation. In particular, the drive must be securely mounted in order to guarantee the specified performance characteristics. Mounting by bottom holes must meet the requirements of Section 10.4.

2.1 STANDARDS

The Cheetah 15K.7 FC family complies with Seagate standards as noted in the appropriate sections of this manual and the
Seagate Fibre Channel Interface Manual, part number 100293070.
The drives are recognized in accordance with UL 60950-1 and CSA 60950-1 as tested by UL and EN60950-1 as tested by TUV.
The security features of Cheetah 15K.7 FC SED models are based on the “TCG Storage Architecture Core Specification” and the “TCG Storage Workgroup Security Subsystem Classs: Enterprise_A” specification with additional vendor-unique features as noted in this product manual.

2.1.1 Electromagnetic compatibility

The drive, as delivered, is designed for system integration and installation into a suitable enclosure prior to use. As such the drive is supplied as a subassembly and is not subject to Subpart B of Part 15 of the FCC Rules and Regulations nor the Radio Interference Regulations of the Canadian Department of Communications.
The design characteristics of the drive serve to minimize radiation when installed in an enclosure that provides reasonable shielding. As such, the drive is capable of meeting the Class B limits of the FCC Rules and Regulations of the Canadian Department of Communications when properly packaged. However, it is the user’s responsibility to assure that the drive meets the appropriate EMI requirements in their system. Shielded I/O cables may be required if the enclosure does not provide adequate shielding. If the I/O cables are external to the enclosure, shielded cables should be used, with the shields grounded to the enclosure and to the host controller.
2.1.1.1 Electromagnetic susceptibility
As a component assembly, the drive is not required to meet any susceptibility performance requirements. It is the responsibility of those integrating the drive within their systems to perform those tests required and design their system to ensure that equipment operating in the same system as the drive or external to the system does not adversely affect the performance of the drive. See Table 2, DC power requirements.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 3

2.1.2 Electromagnetic compliance

Seagate uses an independent laboratory to confirm compliance with the directives/standards for CE Marking and C-Tick Marking. The drive was tested in a representative system for typical applications. The selected system represents the most popular characteristics for test platforms. The system configurations include:
• Typical current use microprocessor
• Keyboard
• Monitor/display
• Printer
• Mouse
Although the test system with this Seagate model complies with the directives/standards, we cannot guarantee that all systems will comply. The computer manufacturer or system integrator shall confirm EMC compliance and provide the appropriate marking for their product.
Electromagnetic compliance for the European Union
If this model has the CE Marking it complies with the European Union requirements of the Electromagnetic Compatibility Directive 89/336/EEC of 03 May 1989 as amended by Directive 92/31/EEC of 28 April 1992 and Directive 93/68/EEC of 22 July 1993.
Australian C-Tick
If this model has the C-Tick Marking it complies with the Australia/New Zealand Standard AS/NZS3548 1995 and meets the Electromagnetic Compatibility (EMC) Framework requirements of Australia’s Spectrum Management Agency (SMA).
Korean KCC
If this model has the Korean Communications Commission (KCC) logo, it complies with paragraph 1 of Article 11 of the Electromagnetic Compatibility (EMC) Control Regulation and meets the Electromagnetic Compatibility Framework requirements of the Radio Research Laboratory (RRL) Ministry of Information and Communication Republic of Korea.
Taiwanese BSMI
If this model has two Chinese words meaning “EMC certification” followed by an eight digit identification number, as a Marking, it complies with Chinese National Standard (CNS) 13438 and meets the Electromagnetic Compatibility (EMC) Framework requirements of the Taiwanese Bureau of Standards, Metrology, and Inspection (BSMI).

2.2 EUROPEAN UNION RESTRICTION OF HAZARDOUS SUBSTANCES (ROHS)

The European Union Restriction of Hazardous Substances (RoHS) Directive restricts the presence of chemical substances, including Lead (Pb), in electronic products effective July 2006.
A number of parts and materials in Seagate products are procured from external suppliers. We rely on the representations of our suppliers regarding the presence of RoHS substances in these parts and materials. Our supplier contracts require compliance with our chemical substance restrictions, and our suppliers document their compliance with our requirements by providing material content declarations for all parts and materials for the disk drives documented in this publication. Current supplier declarations include disclosure of the inclusion of any RoHS-regulated substance in such parts or materials.
Seagate also has internal systems in place to ensure ongoing compliance with the RoHS Directive and all laws and regulations which restrict chemical content in electronic products. These systems include standard operating procedures that ensure that restricted substances are not utilized in our manufacturing operations, laboratory analytical validation testing, and an internal auditing process to ensure that all standard operating procedures are complied with.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 4

2.3 REFERENCE DOCUMENTS

ANSI Fibre Channel Documents X3.230-1994 FC Physical and Signaling Interface (FC-PH) X3.297.1997 FC-PH-2 Fibre Channel Physical and Signaling Interface-2 X3.303.1998 FC-PH-3 Fibre Channel Physical and Signaling Interface-3 X3.272-1996 FC Arbitrated Loop (FC-AL) X3.269-1996 Fibre Channel Protocol for SCSI (FCP) NCITS TR-19 Private Loop SCSI Direct Attach (PLDA) NCITS TR-20 Fabric Loop Attachment (FC-FLA) SFF-8045 Specification for 40-pin SCA-2 Connector with Parallel Selection SFF-8067 Specification for 40-pin SCA-2 Connector with Bidirectional
Enclosure Services Interface
ANSI Small Computer System Interface (SCSI) Documents X3.131-1994 (SCSI-2) X3.270-1996 (SCSI-3) Architecture Model NCITS 305-199X (SCSI-3) Enclosure Services
Trusted Computing Group (TCG) Documents (apply to SED models only) TCG Storage Architechture Core Specification, Rev. 1.0 TCG Storage Security Class Enterprise Specification, Rev. 1.0
Self-Encrypting Drives Users Guide
Seagate part number: 100515636
Specification for Acoustic Test Requirement and Procedures
Seagate part number: 30553-001
Package Test Specification Seagate P/N 30190-001 (under 100 lb.) Package Test Specification Seagate P/N 30191-001 (over 100 lb.)
In case of conflict between this document and any referenced document, this document takes precedence.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 5

3.0 GENERAL DESCRIPTION

Cheetah 15K.7 FC drives provide high performance, high capacity data storage for a variety of systems including engineering workstations, network servers, mainframes, and supercomputers. Cheetah 15K.7 FC drives support 4-Gbit Fibre Channel.
Cheetah 15K.7 FC drives support the Fibre Channel Arbitrated Loop (FC-AL) and SCSI Fibre Channel Protocol as described
in the ANSI specifications, this document, and the Fibre Channel Interface Manual which describes the general interface
characteristics of this drive. Cheetah 15K.7 FC drives are classified as intelligent peripherals and provide level 2 conformance (highest level) with the ANSI SCSI-1 standard.
Cheetah 15K.7 FC SED models have provisions for “Security of Data at Rest” based on the standards defined by the Trusted Computing Group (see www.trustedcomputinggroup.org).
Note. Never disassemble the HDA and do not attempt to service items in the sealed enclosure (heads, media, actuator,
etc.) as this requires special facilities. The drive does not contain user-replaceable parts. Opening the HDA for any reason voids your warranty.
Cheetah 15K.7 FC drives use a dedicated landing zone at the innermost radius of the media to eliminate the possibility of destroying or degrading data by landing in the data zone. The heads automatically go to the landing zone when power is removed from the drive.
An automatic shipping lock prevents potential damage to the heads and discs that results from movement during shipping and handling. The shipping lock disengages and the head load process begins when power is applied to the drive.
The drives also use a high-performance actuator assembly with a low-inertia, balanced, patented, straight arm design that provides excellent performance with minimal power dissipation.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 6

3.1 STANDARD FEATURES

Cheetah 15K.7 FC drives have the following standard features:
• 4-Gbit Fibre Channel interface
• Integrated dual port FC-AL controller
• Concurrent dual port transfers
• Support for FC arbitrated loop, private and public attachment
• Differential copper FC drivers and receivers
• Downloadable firmware using the FC-AL interface
• Supports SCSI enclosure services via interface connector
• 128-deep task set (queue)
• Supports up to 32 initiators
• Drive selection ID and configuration options are set on the FC-AL backpanel or through interface commands. Jumpers are not used on the drive.
• Supports SCSI Enclosure Services through the interface connector
• Fibre Channel worldwide name uniquely identifies the drive and each port
• User-selectable logical block size (512, 520, 524, or 528 bytes per logical block)
• Selectable frame sizes from 256 to 2,112 bytes
• Industry standard 3.5-inch low profile form factor dimensions
• Programmable logical block reallocation scheme
• Flawed logical block reallocation at format time
• Programmable auto write and read reallocation
• Reed-Solomon error correction code
• Sealed head and disk assembly (HDA)
• No preventive maintenance or adjustments required
• Dedicated head landing zone
• Automatic shipping lock
• Embedded Grey Code track address to eliminate seek errors
• Self-diagnostics performed at power on
• Zone bit recording (ZBR)
• Vertical, horizontal, or top down mounting
• Dynamic spindle brake
• 16,384 Kbyte data buffer (see Section 4.5)
• Embedded servo design
• Reallocation of defects on command (Post Format)
• Fibre Channel interface transports SCSI protocol
Cheetah 15K.7 FC SED models have the following additional features :
• Automatic data encryption/decryption
• Controlled access
• Random number generator
• Drive locking
• 16 independent data bands
• Cryptographic erase of user data for a drive that will be repurposed or scrapped
• Authenticated firmware download
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 7

3.2 MEDIA DESCRIPTION

The media used on the drive has an aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for improved durability and environmental protection.

3.3 PERFORMANCE

• Programmable multi-segmentable cache buffer
• 400 Mbytes/sec maximum instantaneous data transfers per port
• 15k RPM spindle; average latency = 2.0 msec
• Command queuing of up to 128 commands
• Background processing of queue
• Supports start and stop commands (spindle stops spinning)
• Adaptive seek velocity; improved seek performance
Note. There is no significant performance difference between Self-Encrypting Drive and standard (non-Self-Encrypting
Drive) models

3.4 RELIABILITY

• Annualized Failure Rate (AFR) of 0.55%
• Increased LSI circuitry integration
• Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T.)
• Dithering
• 5-year warranty

3.5 FORMATTED CAPACITIES

Standard OEM models are formatted to 512 bytes per block. The block size is selectable at format time and must be one of the supported sizes listed in the table below.
Seagate designs specify capacity points at certain block sizes that Seagate guarantees current and future products will meet. We recommend customers use this capacity in their project planning, as it ensures a stable operating point with backward and forward compatibility from generation to generation. The current guaranteed operating points for this product are:
Table 1:
ST3600057FC ST3600957FC
SECTOR SIZE
512 1,172,123,568 45DD2FB0 879,097,968 3465F870 585,937,500 22ECB25C
520 1,147,307,694 446286AE 860,480,771 3349E503 573,653,848 22314358
524 1,132,015,600 43792FF0 849,011,700 329AE3F4 566,007,800 21BC97F8
528 1,115,749,560 4280FCB8 836,812,167 31E0BD87 557,874,778 21407E5A
Seagate drives also may be used at the maximum available capacity at a given block size, but the excess capacity above the guaranteed level will vary between other drive families and from generation to generation, depending on how each block size actually formats out for zone frequencies and splits over servo bursts. This added capacity potential may range from 0.1 to
1.3 percent above the guaranteed capacities listed above. Using the drives in this manner gives the absolute maximum
capacity potential, but the user must determine if the extra capacity potential is useful, or whether their assurance of backward and forward compatibility takes precedence.
ST3600857FC DECIMAL HEX DECIMAL HEX DECIMAL HEX
ST3450857FC ST3450757FC ST3450657FC
ST3300657FC ST3300557FC ST3300457FC
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 8

3.5.1 Programmable drive capacity

Using the Mode Select command, the drive can change its capacity to something less than maximum. See the Mode Select
Parameter List table in the SCSI Commands Reference Manual. Refer to the Parameter list block descriptor number of
blocks field. A value of zero in the number of blocks field indicates that the drive shall not change the capacity it is currently formatted to have. A number in the number of blocks field that is less than the maximum number of LBAs changes the total drive capacity to the value in the block descriptor number of blocks field. A value greater than the maximum number of LBAs is rounded down to the maximum capacity.

3.6 FACTORY-INSTALLED OPTIONS

You may order the following items which are incorporated at the manufacturing facility during production or packaged before shipping. Some of the options available are (not an exhaustive list of possible options):
• Other capacities can be ordered depending on sparing scheme and sector size requested.
• Single-unit shipping pack. The drive is normally shipped in bulk packaging to provide maximum protection against transit damage. Units shipped individually require additional protection as provided by the single unit shipping pack. Users plan­ning single unit distribution should specify this option.
• The Safety and Regulatory Agency Specifications, part number 75789512, is usually included with each standard OEM
drive shipped, but extra copies may be ordered.

3.7 USER-INSTALLED ACCESSORIES

The following accessories are available. All kits may be installed in the field.
• Evaluation kit, part number 73473641. This kit provides an adapter card (“T-card”) to allow cable connections for two FC ports and DC power.
• Single-unit shipping pack.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 9

4.0 PERFORMANCE CHARACTERISTICS

This section provides detailed information concerning performance-related characteristics and features of Cheetah 15K.7 FC drives.

4.1 INTERNAL DRIVE CHARACTERISTICS

ST3600057FC ST3450857FC ST3300657FC ST3600957FC ST3450757FC ST3300557FC
ST3600857FC ST3450657FC ST3300457FC Drive capacity 600 450 300 Gbytes (formatted, rounded off value) Read/write data heads 8 6 4 Tracks per inch 165,000 165,000 165,000 TPI Peak bits per inch 1,361 1,361 1,361 KBPI Areal Density 225 225 225 Gbits/inch Internal data rate 1.49 - 2.37 1.49 - 2.37 1.49 - 2.37 Gbits/sec (max) disk rotation speed 15k 15k 15k RPM Avg rotational latency 2.0 2.0 2.0 msec
*One Gbyte equals one billion bytes when referring to hard drive capacity. Accessible capacity may vary depending on operating environment and formatting.
2

4.2 SEEK PERFORMANCE CHARACTERISTICS

*
See Section 11.5, "FC-AL physical interface" on page 56 and the Fibre Channel Interface Manual (part number 77767496)
for additional timing details.

4.2.1 Access time

NOT INCLUDING CONTROLLER
1
2
,
OVERHEAD
(MSEC)
READ WRITE
Average Typical 3.4 3.9
Single track Typical 0.2 0.44
Full stroke Typical 6.6 7.4
1. Typical access times are measured under nominal conditions of temperature, voltage, and
horizontal orientation as measured on a representative sample of drives.
2. Access to data = access time + latency time.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 10

4.2.2 Format command execution time (minutes)

When changing sector sizes, the format times shown below may need to be increased by 30 minutes.
ST3600057FC ST3450857FC ST3300657FC
Maximum (with verify)
Maximum (without verify)
119 88 58
60 44 29
Note. There is approximately a 1.5 increase in time to format a SED drive versus a non-SED drive of the same capacity.

4.2.3 General performance characteristics

Sustainable disk transfer rate*:
Minimum 122 Mbytes/sec (typical)
Maximum 204 Mbytes/sec (typical)
Fibre Channel Interface maximum instantaneous transfer rate 400 Mbytes/sec* per port
Logical block sizes
Default is 512-byte data blocks Sector sizes variable to 512, 520, 524 and 528 bytes.
Read/write consecutive sectors on a track Yes
Flaw reallocation performance impact (for flaws reallocated at format time using the spare sectors per sparing zone reallocation scheme.)
Average rotational latency 2.0 msec
Negligible
*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or from the host. 1MB/sec = 1,000,000 bytes/sec

4.3 START/STOP TIME

If the Motor Start option is disabled, the drive becomes ready within 20 seconds after DC power is applied. If a recoverable error condition is detected during the start sequence, the drive executes a recovery procedure and the time to become ready may exceed 20 seconds. During spin up to ready time, the drive responds to some commands over the FC interface in less than 3 seconds after application of power. Stop time is 30 seconds (maximum) from removal of DC power.
If the Motor Start option is enabled, the internal controller accepts the commands listed in the Fibre Channel Interface Manual less than 3 seconds after DC power has been applied. After the Motor Start command has been received, the drive
becomes ready for normal operations within 20 seconds (excluding the error recovery procedure). The Motor Start command can also be used to command the drive to stop the spindle.
There is no power control switch on the drive.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 11

4.4 PREFETCH/MULTI-SEGMENTED CACHE CONTROL

The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in cache operations. To select this feature, the host sends the Mode Select command with the proper values in the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint that each is enabled and disabled independently using the Mode Select command; however, in actual operation, the prefetch feature overlaps cache operation somewhat as described in sections 4.5.1 and 4.5.2.
All default cache and prefetch mode parameter values (Mode Page 08h) for standard OEM versions of this drive family are given in Table 18.

4.5 CACHE OPERATION

Note. Refer to the Fibre Channel Interface Manual for more detail concerning the cache bits.
Of the 16 Mbytes physical buffer space in the drive, approximately 13,000 kbytes can be used as a cache. The buffer is divided into logical segments from which data is read and to which data is written.
The drive keeps track of the logical block addresses of the data stored in each segment of the buffer. If the cache is enabled
(see RCD bit in the FC Interface Manual ), data requested by the host with a read command is retrieved from the buffer, if
possible, before any disk access is initiated. If cache operation is not enabled, the buffer is still used, but only as circular buffer segments during disk medium read operations (disregarding Prefetch operation for the moment). That is, the drive does not check in the buffer segments for the requested read data, but goes directly to the medium to retrieve it. The retrieved data merely passes through some buffer segment on the way to the host. All data transfers to the host are in accordance with buffer-full ratio rules. See the explanation provided with the information about Mode Page 02h (disconnect/
reconnect control) in the Fibre Channel Interface Manual.
The following is a simplified description of the prefetch/cache operation:
Case A—read command is received and all of the requested logical blocks are already in the cache:
1. Drive transfers the requested logical blocks to the initiator.
Case B—A Read command requests data, and at least one requested logical block is not in any segment of the cache:
1. The drive fetches the requested logical blocks from the disk and transfers them into a segment, and then from there to
the host in accordance with the Mode Select Disconnect/Reconnect parameters, page 02h.
2. If the prefetch feature is enabled, refer to section 4.5.2 for operation from this point.
Each cache segment is actually a self-contained circular buffer whose length is an integer number of logical blocks. The drive dynamically creates and removes segments based on the workload. The wrap-around capability of the individual segments greatly enhances the cache’s overall performance.
Note. The size of each segment is not reported by Mode Sense command page 08h, bytes 14 and 15. The value
0XFFFF is always reported regardless of the actual size of the segment. Sending a size specification using the Mode Select command (bytes 14 and 15) does not set up a new segment size. If the STRICT bit in Mode page 00h (byte 2, bit 1) is set to one, the drive responds as it does for any attempt to change an unchangeable param­eter.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 12

4.5.1 Caching write data

Write caching is a write operation by the drive that makes use of a drive buffer storage area where the data to be written to the medium is stored while the drive performs the Write command.
If read caching is enabled (RCD=0), then data written to the medium is retained in the cache to be made available for future read cache hits. The same buffer space and segmentation is used as set up for read functions. The buffer segmentation scheme is set up or changed independently, having nothing to do with the state of RCD. When a write command is issued, if RCD=0, the cache is first checked to see if any logical blocks that are to be written are already stored in the cache from a previous read or write command. If there are, the respective cache segments are cleared. The new data is cached for subsequent Read commands.
If the number of write data logical blocks exceed the size of the segment being written into, when the end of the segment is reached, the data is written into the beginning of the same cache segment, overwriting the data that was written there at the beginning of the operation; however, the drive does not overwrite data that has not yet been written to the medium.
If write caching is enabled (WCE=1), then the drive may return Good status on a write command after the data has been transferred into the cache, but before the data has been written to the medium. If an error occurs while writing the data to the medium, and Good status has already been returned, a deferred error will be generated.
The Synchronize Cache command may be used to force the drive to write all cached write data to the medium. Upon completion of a Synchronize Cache command, all data received from previous write commands will have been written to the medium.
Table 18 shows the mode default settings for the drive.

4.5.2 Prefetch operation

If the Prefetch feature is enabled, data in contiguous logical blocks on the disk immediately beyond that which was requested by a Read command are retrieved and stored in the buffer for immediate transfer from the buffer to the host on subsequent Read commands that request those logical blocks (this is true even if cache operation is disabled). Though the prefetch operation uses the buffer as a cache, finding the requested data in the buffer is a prefetch hit, not a cache operation hit.
To enable Prefetch, use Mode Select page 08h, byte 12, bit 5 (Disable Read Ahead - DRA bit). DRA bit = 0 enables prefetch.
The drive does not use the Max Prefetch field (bytes 8 and 9) or the Prefetch Ceiling field (bytes 10 and 11).
When prefetch (read look-ahead) is enabled (enabled by DRA = 0), the drive enables prefetch of contiguous blocks from the disk when it senses that a prefetch hit will likely occur. The drive disables prefetch when it decides that a prefetch hit is not likely to occur.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 13

5.0 RELIABILITY SPECIFICATIONS

The following reliability specifications assume correct host and drive operational interface, including all interface timings, power supply voltages, environmental requirements and drive mounting constraints.
8
Seek error rate: Less than 10 errors in 10 Read Error Rates
Recovered Data Less than 10 errors in 10 Unrecovered Data Less than 1 sector in 1016 bits transferred Miscorrected Data Less than 1 sector in 10
Interface error rate: Less than 1 error in 10
Less than 1 error in 1014 bits transferred with typical receive eye.
See Section 11.6.4, "FC Differential input." on page 65 Annualized Failure Rate (AFR): 0.55% Preventive maintenance: None required

5.1 ERROR RATES

The error rates stated in this manual assume the following:
• The drive is operated in accordance with this manual using DC power as defined in paragraph 6.2, "DC power require­ments."
• Errors caused by host system failures are excluded from error rate computations.
• Assume random data.
• Default OEM error recovery settings are applied. This includes AWRE, ARRE, full read retries, full write retries and full retry time.
• Error rate specified with automatic retries and data correction with ECC enabled and all flaws reallocated.
seeks
12
bits transferred (OEM default settings)
21
bits transferred
12
bits transferred with minimum receive eye.

5.1.1 Recoverable Errors

Recovereable errors are those detected and corrected by the drive, and do not require user intervention.
Recoverable Data errors use retries and correction. Application of ECC on-the-fly correction alone is not considered a Recovered Data error.
Recovered Data error rate is determined using read bits transferred for recoverable errors occurring during a read, and using write bits transferred for recoverable errors occurring during a write.

5.1.2 Unrecoverable Errors

Unrecoverable Data Errors (Sense Key = 03h) are specified at less than 1 sector in error per 1016 bits transferred. Unrecoverable Data Errors resulting from the same cause are treated as 1 error for that block.

5.1.3 Seek errors

A seek error is defined as a failure of the drive to position the heads to the addressed track. After detecting an initial seek error, the drive automatically performs an error recovery process. If the error recovery process fails, a seek positioning error (Error code = 15h or 02h) will be reported with a Hardware error (04h) in the Sense Key. Recoverable seek errors are specified at Less than 10 errors in 108 seeks. Unrecoverable seek errors (Sense Key = 04h) are classified as drive failures.

5.1.4 Interface errors

An interface error is defined as a failure of the receiver on a port to recover the data as transmitted by the device port connected to the receiver. The error may be detected as a running disparity error, illegal code, loss of word sync, or CRC error. The total error rate for a loop of devices is the sum of the individual device error rates.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 14

5.2 RELIABILITY AND SERVICE

You can enhance the reliability of Constellation ES.3 SAS disk drives by ensuring that the drive receives adequate cooling. Section 6.0 provides temperature measurements and other information that may be used to enhance the service life of the drive. Section 10.2 provides recommended air-flow information.

5.2.1 Annualized Failure Rate (AFR) and Mean Time Between Failures (MTBF)

These drives shall achieve an AFR of 0.55% (MTBF of 1,600,000 hours) when operated in an environment that ensures the HDA case temperatures do not exceed the values specified in Section 6.4.1.
Operation at case temperatures outside the specifications in Section 6.4.1 may increase the AFR (decrease the MTBF). AFR and MTBF statistics are poplulation statistics that are not relevant to individual units.
AFR and MTBF specifications are based on the following assumptions for Enterprise Storage System environments:
• 8,760 power-on hours per year
• 250 average on/off cycles per year
• Operating at nominal voltages
• System provides adequate cooling to ensure the case temperatures specified in Section 6.4.1 are not exceeded.

5.2.2 Preventive maintenance

No routine scheduled preventive maintenance is required.

5.2.3 Hot plugging the drive

Inserting and removing the drive on the FC-AL will interrupt loop operation. The interruption occurs when the receiver of the next device in the loop must synchronize to a different input signal. FC error detection mechanisms, character sync, running disparity, word sync, and CRC are able to detect any error. Recovery is initiated based on the type of error.
The disk drive defaults to the FC-AL Monitoring state, Pass-through state, when it is powered-on by switching the power or hot plugged. The control line to an optional port bypass circuit (external to the drive), defaults to the Enable Bypass state. If the bypass circuit is present, the next device in the loop will continue to receive the output of the previous device to the newly inserted device. If the bypass circuit is not present, loop operation is temporarily disrupted until the next device starts receiving the output from the newly inserted device and regains synchronization to the new input.
The Pass-through state is disabled while the drive performs self test of the FC interface. The control line for an external port bypass circuit remains in the Enable Bypass state while self test is running. If the bypass circuit is present, loop operation may continue. If the bypass circuit is not present, loop operation will be halted while the self test of the FC interface runs.
When the self test completes successfully, the control line to the bypass circuit is disabled and the drive enters the FC-AL Initializing state. The receiver on the next device in the loop must synchronize to output of the newly inserted drive.
If the self-test fails, the control line to the bypass circuit remains in the Enable Bypass state.
Note. It is the responsibility of the systems integrator to assure that no temperature, energy, voltage hazard, or ESD
potential hazard is presented during the hot connect/disconnect operation. Discharge the static electricity from the drive carrier prior to inserting it into the system.
Caution. The drive motor must come to a complete stop prior to changing the plane of operation. This time is required to
insure data integrity.

5.2.4 S.M.A.R.T.

S.M.A.R.T. is an acronym for Self-Monitoring Analysis and Reporting Technology. This technology is intended to recognize conditions that indicate imminent drive failure and is designed to provide sufficient warning of a failure to allow you to back up the data before an actual failure occurs.
Note. The drive’s firmware monitors specific attributes for degradation over time but can’t predict instantaneous drive
failures.
Each monitored attribute has been selected to monitor a specific set of failure conditions in the operating performance of the drive and the thresholds are optimized to minimize “false” and “failed” predictions.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 15
Controlling S.M.A.R.T.
The operating mode of S.M.A.R.T. is controlled by the DEXCPT and PERF bits on the Informational Exceptions Control mode page (1Ch). Use the DEXCPT bit to enable or disable the S.M.A.R.T. feature. Setting the DEXCPT bit disables all S.M.A.R.T. functions. When enabled, S.M.A.R.T. collects on-line data as the drive performs normal read and write operations. When the PERF bit is set, the drive is considered to be in “On-line Mode Only” and will not perform off-line functions.
You can measure off-line attributes and force the drive to save the data by using the Rezero Unit command. Forcing S.M.A.R.T. resets the timer so that the next scheduled interrupt is in two hours.
You can interrogate the drive through the host to determine the time remaining before the next scheduled measurement and data logging process occurs. To accomplish this, issue a Log Sense command to log page 0x3E. This allows you to control when S.M.A.R.T. interruptions occur. Forcing S.M.A.R.T. with the RTZ command resets the timer.
Performance impact
S.M.A.R.T. attribute data is saved to the disk so that the events that caused a predictive failure can be recreated. The drive measures and saves parameters once every two hours subject to an idle period on the FC-AL bus. The process of measuring off-line attribute data and saving data to the disk is uninterruptable. The maximum on-line only processing delay is summarized below:
Table 2:
Maximum processing delay
S.M.A.R.T. delay times
On-line only delay DEXCPT = 0, PERF = 1
42 milliseconds
Fully-enabled delay DEXCPT = 0, PERF = 0
163 milliseconds
Reporting control
Reporting is controlled by the MRIE bits in the Informational Exceptions Control mode page (1Ch). Subject to the reporting method, the firmware will issue to the host an 01-5Dxx sense code. The error code is preserved through bus resets and power cycles.
Determining rate
S.M.A.R.T. monitors the rate at which errors occur and signals a predictive failure if the rate of degraded errors increases to an unacceptable level. To determine rate, error events are logged and compared to the number of total operations for a given attribute. The interval defines the number of operations over which to measure the rate. The counter that keeps track of the current number of operations is referred to as the Interval Counter.
S.M.A.R.T. measures error rates. All errors for each monitored attribute are recorded. A counter keeps track of the number of errors for the current interval. This counter is referred to as the Failure Counter.
Error rate is the number of errors per operation. The algorithm that S.M.A.R.T. uses to record rates of error is to set thresholds for the number of errors and their interval. If the number of errors exceeds the threshold before the interval expires, the error rate is considered to be unacceptable. If the number of errors does not exceed the threshold before the interval expires, the error rate is considered to be acceptable. In either case, the interval and failure counters are reset and the process starts over.
Predictive failures
S.M.A.R.T. signals predictive failures when the drive is performing unacceptably for a period of time. The firmware keeps a running count of the number of times the error rate for each attribute is unacceptable. To accomplish this, a counter is incremented each time the error rate is unacceptable and decremented (not to exceed zero) whenever the error rate is acceptable. If the counter continually increments such that it reaches the predictive threshold, a predictive failure is signaled. This counter is referred to as the Failure History Counter. There is a separate Failure History Counter for each attribute.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 16

5.2.5 Thermal monitor

Cheetah 15K.7 FC drives implement a temperature warning system which:
1. Signals the host if the temperature exceeds a value which would threaten the drive.
2. Signals the host if the temperature exceeds a user-specified value.
3. Saves a S.M.A.R.T. data frame on the drive which exceeds the threatening temperature value.
A temperature sensor monitors the drive temperature and issues a warning over the interface when the temperature exceeds a set threshold. The temperature is measured at power-up and then at ten-minute intervals after power-up.
The thermal monitor system generates a warning code of 01-0B01 when the temperature exceeds the specified limit in compliance with the SCSI standard. The drive temperature is reported in the FRU code field of mode sense data. You can use this information to determine if the warning is due to the temperature exceeding the drive threatening temperature or the user-specified temperature.
This feature is controlled by the Enable Warning (EWasc) bit, and the reporting mechanism is controlled by the Method of Reporting Informational Exceptions field (MRIE) on the Informational Exceptions Control (IEC) mode page (1Ch).
The current algorithm implements two temperature trip points. The first trip point is set at 68°C which is the maximum temperature limit according to the drive specification. The second trip point is user-selectable using the Log Select command. The reference temperature parameter in the temperature log page (see Table 1) can be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of 0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense code is sent to the host to indicate the rounding of the parameter field.
Table 1: Temperature Log Page (0Dh)
Parameter Code Description
0000h
0001h
Primary Temperature
Reference Temperature

5.2.6 Drive Self Test (DST)

Drive Self Test (DST) is a technology designed to recognize drive fault conditions that qualify the drive as a failed unit. DST validates the functionality of the drive at a system level.
There are two test coverage options implemented in DST:
1. Extended test
2. Short test
The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does some fundamental tests and scans portions of the media.
If DST encounters an error during either of these tests, it reports a fault condition. If the drive fails the test, remove it from service and return it to Seagate for service.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 17
5.2.6.1 DST failure definition
The drive will present a “diagnostic failed” condition through the self-tests results value of the diagnostic log page if a functional failure is encountered during DST. The channel and servo parameters are not modified to test the drive more stringently, and the number of retries are not reduced. All retries and recovery processes are enabled during the test. If data is recoverable, no failure condition will be reported regardless of the number of retries required to recover the data.
The following conditions are considered DST failure conditions:
• Seek error after retries are exhausted
• Track-follow error after retries are exhausted
• Read error after retries are exhausted
• Write error after retries are exhausted
Recovered errors will not be reported as diagnostic failures.
5.2.6.2 Implementation
This section provides all of the information necessary to implement the DST function on this drive.
5.2.6.2.1 State of the drive prior to testing
The drive must be in a ready state before issuing the Send Diagnostic command. There are multiple reasons why a drive may not be ready, some of which are valid conditions, and not errors. For example, a drive may be in process of doing a format, or another DST. It is the responsibility of the host application to determine the “not ready” cause.
While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.
A Drive Not Ready condition is reported by the drive under the following conditions:
• Motor will not spin
• Motor will not lock to speed
• Servo will not lock on track
• Drive cannot read configuration tables from the disk
In these conditions, the drive responds to a Test Unit Ready command with an 02/04/00 or 02/04/03 code.
5.2.6.2.2 Invoking DST
To invoke DST, submit the Send Diagnostic command with the appropriate Function Code (001b for the short test or 010b for the extended test) in bytes 1, bits 5, 6, and 7.
5.2.6.2.3 Short and extended tests
DST has two testing options:
1. short
2. extended
These testing options are described in the following two subsections.
Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan segment.
Short test (Function Code: 001b)
The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within 120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and scans portions of the media. A complete read/verify scan is not performed and only factual failures will report a fault condition. This option provides a quick confidence test of the drive.
Extended test (Function Code: 010b)
The objective of the extended test option is to empirically test critical drive components. For example, the seek tests and on­track operations test the positioning mechanism. The read operation tests the read head element and the media surface. The write element is tested through read/write/read operations. The integrity of the media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of these tests.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 18
The anticipated length of the Extended test is reported through the Control Mode page.
5.2.6.2.4 Log page entries
When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created by inserting a new self-test parameter block at the beginning of the self-test results log parameter section of the log page. Existing data will be moved to make room for the new parameter block. The drive reports 20 parameter blocks in the log page. If there are more than 20 parameter blocks, the least recent parameter block will be deleted. The new parameter block will be initialized as follows:
1. The Function Code field is set to the same value as sent in the DST command
2. The Self-Test Results Value field is set to Fh
3. The drive will store the log page to non-volatile memory
After a self-test is complete or has been aborted, the drive updates the Self-Test Results Value field in its Self-Test Results Log page in non-volatile memory. The host may use Log Sense to read the results from up to the last 20 self-tests performed by the drive. The self-test results value is a 4-bit field that reports the results of the test. If the field is set to zero, the drive passed with no errors detected by the DST. If the field is not set to zero, the test failed for the reason reported in the field.
The drive will report the failure condition and LBA (if applicable) in the Self-test Results Log parameter. The Sense key, ASC, ASCQ, and FRU are used to report the failure condition.
5.2.6.2.5 Abort
There are several ways to abort a diagnostic. You can use a SCSI Bus Reset or a Bus Device Reset message to abort the diagnostic.
You can abort a DST executing in background mode by using the abort code in the DST Function Code field. This will cause a 01 (self-test aborted by the application client) code to appear in the self-test results values log. All other abort mechanisms will be reported as a 02 (self-test routine was interrupted by a reset condition).

5.2.7 Product warranty

Beginning on the date of shipment to the customer and continuing for the period specified in your purchase contract, Seagate warrants that each product (including components and subassemblies) that fails to function properly under normal use due to defect in materials or workmanship or due to nonconformance to the applicable specifications will be repaired or replaced, at Seagate’s option and at no charge to the customer, if returned by customer at customer’s expense to Seagate’s designated facility in accordance with Seagate’s warranty procedure. Seagate will pay for transporting the repair or replacement item to the customer. For more detailed warranty information, refer to the standard terms and conditions of purchase for Seagate products on your purchase documentation.
The remaining warranty for a particular drive can be determined by calling Seagate Customer Service at 1-800-468-3472. You can also determine remaining warranty using the Seagate web site (www.seagate.com). The drive serial number is required to determine remaining warranty information.
Shipping
When transporting or shipping a drive, use only a Seagate-approved container. Keep your original box. Seagate approved containers are easily identified by the Seagate Approved Package label. Shipping a drive in a non-approved container voids the drive warranty.
Seagate repair centers may refuse receipt of components improperly packaged or obviously damaged in transit. Contact your authorized Seagate distributor to purchase additional boxes. Seagate recommends shipping by an air-ride carrier experienced in handling computer equipment.
Product repair and return information
Seagate customer service centers are the only facilities authorized to service Seagate drives. Seagate does not sanction any third-party repair facilities. Any unauthorized repair or tampering with the factory seal voids the warranty.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 19

6.0 PHYSICAL/ELECTRICAL SPECIFICATIONS

This section provides information relating to the physical and electrical characteristics of the drive.

6.1 AC POWER REQUIREMENTS

None.

6.2 DC POWER REQUIREMENTS

The voltage and current requirements for a single drive are shown below. Values indicated apply at the drive connector. Notes are shown following the last power requirements table.
The standard drive models and the SED drive models have identical hardware, however the security and encryption portion of the drive controller ASIC is enabled and functional in the SED models. This represents a small additional drain on the 5V supply of about 30mA and a commensurate increase of about 150mW in power consumption. There is no additional drain on the 12V supply.
Table 2 ST3600057FC DC power requirements
2 Gbit 4 Gbit
Notes (Amps) (Amps) (Amps) (Amps) Voltage +5V +12V [2] +5V +12V [2] Regulation [5] ±5% ±5% [2] ±5% ±5% [2] Avg idle current DCX [1] [7] 0.39 0.81 0.42 0.81 Maximum starting current
(peak DC) DC 3s [3] 0.67 1.93 0.70 1.92 (peak AC) AC 3s [3] 1.02 3.73 1.00 3.61
Delayed motor start (max) DC
Peak operating current: Typical DCX [1] [6] 0.48 1.18 0.51 1.17 Maximum DC 3s [1] 0.50 1.19 0.53 1.19 Maximum (peak) DC 3s 1.30 3.00 1.32 2.98
3s [1] [4] 0.55 0.04 0.58 0.04
Table 3 ST3450857FC DC power requirements
2 Gbit 4 Gbit
Notes (Amps) (Amps) (Amps) (Amps) Voltage +5V +12V [2] +5V +12V [2] Regulation [5] ±5% ±5% [2] ±5% ±5% [2] Avg idle current DCX [1] [7] 0.40 0.69 0.42 0.69 Maximum starting current
(peak DC) DC 3s [3] 0.69 1.85 0.72 1.85 (peak AC) AC 3s [3] 1.08 3.77 1.08 3.49
Delayed motor start (max)
3s [1] [4] 0.58 0.04 0.61 0.04
DC Peak operating current: Typical DCX [1] [6] 0.49 1.04 0.53 1.03 Maximum DC 3s [1] 0.53 1.07 0.57 1.07 Maximum (peak) DC 3s 1.36 2.80 1.40 2.84
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 20
Table 4 ST3300657FC DC power requirements
2 Gbit 4 Gbit
Notes(Amps) (Amps) (Amps) (Amps)
Voltage +5V +12V [2] +5V +12V [2] Regulation [5] ±5% ±5% [2] ±5% ±5% [2] Avg idle current DCX [1] [7] 0.39 0.59 0.39 0.59 Maximum starting current
(peak DC) DC 3s [3] 0.62 1.91 0.62 1.91 (peak AC) AC 3s [3] 0.96 3.75 0.98 3.57
Delayed motor start (max)
3s [1] [4] 0.56 0.04 0.56 0.04
DC Peak operating current: Typical DC
X [1] [6] 0.48 0.92 0.48 0.91 Maximum DC 3s [1] 0.53 1.00 0.53 0.95 Maximum (peak) DC 3s 1.32 2.80 1.32 2.72
[1] Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these values. Power sup-
ply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.
[2] For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 15000 RPM.
The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive
is able to accept selection by the host initiator. [3] See +12V current profile in Figure 1. [4] This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start Motor command. [5] See paragraph 6.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient
response. [6] Operating condition is defined as random 8 block reads at 375 I/Os per second for 600GB models and 380 I/Os per sec-
ond for 450GB and 300GB models. Current and power specified at nominal voltages. [7] During idle, the drive heads are relocated every 60 seconds to a random location within the band from three-quarters to
maximum track.
General DC power requirement notes.
1. Minimum current loading for each supply voltage is not less than 1.2% of the maximum operating current shown.
2. The +5V and +12V supplies should employ separate ground returns.
3. Where power is provided to multiple drives from a common supply, careful consideration for individual drive power
requirements should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to each device.
4. Parameters, other than spindle start, are measured after a 10-minute warm up.
5. No terminator power.

6.2.1 Conducted noise immunity

Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz. Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power connector.
+5 V = 250 mV pp from 100 Hz to 20 MHz. +12 V = 800 mV pp from 100 Hz to 8 KHz.
450 mV pp from 8 KHz to 20 KHz. 250 mV pp from 20 KHz to 5 MHz.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 21

6.2.2 Power sequencing

The drive does not require power sequencing. The drive protects against inadvertent writing during power-up and down.

6.2.3 Current profiles

The +12V and +5V current profiles are shown in the following figures.
Note: All times and currents are typical. See Section 6.2 for maximum current requirements.
Figure 1. Typical ST3600057FC current profiles
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 22
Figure 2. Typical ST3450857FC current profiles
Figure 3. Typical ST3300657FC current profiles
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 23

6.3 POWER DISSIPATION

600GB model
Typical power dissipation under idle conditions in 4 Gbit operation is 11.58 watts (39.52 BTUs per hour).
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 4). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123.
Figure 4. ST3600057FC DC current and power vs. input/output operations per second
450GB models
Typical power dissipation under idle conditions in 4 Gbit operation is 10.24 watts (34.94 BTUs per hour).
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 4). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123.
Figure 5. ST3450857FC DC current and power vs. input/output operations per second
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 24
300GB models
Typical power dissipation under idle conditions in 4 Gbit operation is 9.06 watts (30.92 BTUs per hour).
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 4). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123.
Figure 6. ST3300657FC DC current and power vs. input/output operations per second
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 25

6.4 ENVIRONMENTAL LIMITS

Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F (14.8°C). Maximum wet bulb temperature is 82°F (28°C).

6.4.1 Temperature

a. Operating
The maximum allowable continuous or sustained HDA case temperature for the rated Annualized Failure Rate (AFR) is 122°F (50°C). The maximum allowable HDA case temperature is 60°C. Occasional excursions of HDA case temperatures above 122°F (50°C) or below 41°F (5°C) may occur without impact to the specified AFR. Continual or sustained operation at HDA case temperatures outside these limits may degrade AFR.
Provided the HDA case temperatures limits are met, the drive meets all specifications over a 41°F to 131°F (5°C to 55°C) drive ambient temperature range with a maximum temperature gradient of 68°F (20°C) per hour. Air flow may be needed in the drive enclosure to keep within this range (see Section 8.3). Operation at HDA case temperatures outside this range may adversely affect the drives ability to meet specifications. To confirm that the required cooling for the electronics and HDA case is provided, place the drive in its final mechanical configuration, perform random write/read operations and measure the HDA case temperature after it has stabilized.
b. Non-operating
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 68°F (20°C) per hour. This specification assumes that the drive is packaged in the shipping container designed by Seagate for use with drive.
HDA Temp.
Check Point
Figure 7. Locations of the HDA temperature check point
1.0 .5

6.4.2 Relative humidity

The values below assume that no condensation on the drive occurs.
a. Operating
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
b. Non-operating
5% to 95% non-condensing relative humidity.

6.4.3 Effective altitude (sea level)

a. Operating
–1,000 to +10,000 feet (–305 to +3,048 meters)
b. Non-operating
–1,000 to +40,000 feet (–305 to +12,210 meters)
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 26

6.4.4 Shock and vibration

Shock and vibration limits specified in this document are measured directly on the drive chassis. If the drive is installed in an enclosure resulting in drive movement in excess of the stated limits. If this situation is apparent, it may be necessary to modify the enclosure to minimize drive movement.
The limits of shock and vibration defined within this document are specified with the drive mounted by any of the four methods shown in Figure 8, and in accordance with the restrictions of Section 10.4. Orientation of the side nearest the I/O connector may be up or down.
6.4.4.1 Shock
a. Operating—normal
Shock may be applied in the X, Y, or Z axis. Shock is not to be repeated more than once every 2 seconds.
b. Operating—abnormal
c. Non-operating
to which the stated shock and/or vibration criteria is applied, resonances may occur internally to the enclosure
The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not exceeding:
• 15 Gs at a duration of 11 msec (half sinewave)
• 20 Gs at a duration of 2 msec (half sinewave)
• 60 Gs at a duration of 2 msec (half sinewave) when performing reads only
Equipment, as installed for normal operation, does not incur physical damage while subjected to intermittent shock not exceeding 40 Gs at a duration of 11 msec (half sinewave). Shock occurring at abnormal levels may promote degraded operational performance during the abnormal shock period. Specified operational performance will continue when normal operating shock levels resume. Shock may be applied in the X, Y, or Z axis. Shock is not to be repeated more than once every 2 seconds.
The limits of non-operating shock shall apply to all conditions of handling and transportation. This includes both isolated drives and integrated drives.
The drive subjected to nonrepetitive shock not exceeding the three values below, shall not exhibit device damage or performance degradation.
• 80 Gs at a duration of 11 msec (half sinewave)
300 Gs at a duration of 2 msec (half sinewave)
• 150 Gs at a duration of 0.5 msec (half sinewave)
Shock may be applied in the X, Y, or Z axis.
d. Packaged
Disk drives shipped as loose load (not palletized) general freight will be packaged to withstand drops from heights as defined in the table below. For additional details refer to Seagate specifications 30190-001 (under 100 lbs/45 kg) or 30191-001 (over 100 lbs/45 Kg).
PACKAGE SIZE PACKAGED/PRODUCT WEIGHT DROP HEIGHT
<600 cu in (<9,800 cu cm) Any 60 in (1524 mm) 600-1800 cu in (9,800-19,700 cu cm) 0-20 lb (0 to 9.1 kg) 48 in (1219 mm) >1800 cu in (>19,700 cu cm) 0-20 lb (0 to 9.1 kg) 42 in (1067 mm) >600 cu in (>9,800 cu cm) 20-40 lb (9.1 to 18.1 kg) 36 in (914 mm)
Drives packaged in single or multipacks with a gross weight of 20 pounds (8.95 kg) or less by Seagate for general freight shipment shall withstand a drop test from 48 inches (1,070 mm) against a concrete floor or equivalent.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 27
Z
Y
X
Figure 8. Recommended mounting
X
Z
Y
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 28
6.4.4.2 Vibration
a. Operating—normal
The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding
10 – 300 Hz 1.0 G RMS (0 to peak) 301– 500 Hz 0.5 G RMS (0 to peak)
Vibration may be applied in the X, Y, or Z axis.
b. Operating—abnormal
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding:
15 minutes of duration at major resonant frequency
Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available.
Operating abnormal translational random flat profile
5 – 500 Hz 0.75 G (0 to peak) 10 - 300 Hz 0.0029 G2/Hz
c. Non-operating
The limits of non-operating vibration shall apply to all conditions of handling and transportation. This includes both isolated drives and integrated drives.
The drive shall not incur physical damage or degraded performance as a result of continuous vibration not exceeding
5 – 22 Hz 0.25 G (0 to peak, linear, swept sine, 0.5 octive/min) 22 - 350 Hz 3 G (0 to peak, linear, swept sine, 0.5 octive/min) 350 - 500 Hz 1 G (0 to peak, linear, swept sine, 0.5 octive/min)
Vibration may be applied in the X, Y, or Z axis.

6.4.5 Acoustics

Sound power during idle mode shall be 3.4 bels typical when measured to ISO 7779 specification. Sound power while operating shall be 3.8 bels typical when measured to ISO 7779 specification.
There will not be any discrete tones more than 10 dB above the masking noise on typical drives when measured according to Seagate specification 30553-001. There will not be any tones more than 24 dB above the masking noise on any drive.

6.4.6 Air cleanliness

The drive is designed to operate in a typical office environment with minimal environmental control.

6.4.7 Corrosive environment

Seagate electronic drive components pass accelerated corrosion testing equivalent to 10 years exposure to light industrial environments containing sulfurous gases, chlorine and nitric oxide, classes G and H per ASTM B845. However, this accelerated testing cannot duplicate every potential application environment.
Users should use caution exposing any electronic components to uncontrolled chemical pollutants and corrosive chemicals as electronic drive component reliability can be affected by the installation environment. The silver, copper, nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide, chloride, and nitrate contaminants. Sulfur is found to be the most damaging. In addition, electronic components should never be exposed to condensing water on the surface of the printed circuit board assembly (PCBA) or exposed to an ambient relative humidity greater than 95%. Materials used in cabinet fabrication, such as vulcanized rubber, that can outgas corrosive compounds should be minimized or eliminated. The useful life of any electronic equipment may be extended by replacing materials near circuitry with sulfide-free alternatives.

6.4.8 Electromagnetic susceptibility

See Section 2.1.1.1.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 29

6.5 MECHANICAL SPECIFICATIONS

Refer to Figure 9 for detailed physical dimensions. See Section 10.4, “Drive mounting.””
Height: 1.03 in 26.10 mm Width: 4.00 in 101.60 mm Depth: 5.79 in 147 mm Weight (max): 1.76 pounds 0.80 kilograms
B
J
K
-Z-
Notes:
[1]
Mounting holes are 6-32 UNC 2B, three on each side and four on the bottom. Max screw penetration into side of drive is 0.15 in. (3.81 mm). Max screw tightening torque is 6.0 in-lb (0.6779 nm) with minimum full thread engagement of 0.12 in. (3.05 mm).
-Z- T //
-Z-
S
REF
A
M
H
L
[1]
R REF
-X- N
C
-X-
-X- U
P
F
[1]
E
D
Figure 9. Mounting configuration dimensions
A
B C D E F H
J K
L M N P R S T U
Dimension Table
Inches
1.028
max
5.787
max
4.000
± .010
3.750
± .010
0.125
± .010
1.750
± .010
1.122
± .020
4.000
± .010
0.250
± .010
1.638
± .010
0.181 .040
1.625
1.618
0.276 .015 .015
± .020
± .040 max max
Millimeters
26.10
147.00
101.60
95.25
3.18
44.45
28.50
101.60
6.35
41.60
4.60
1.02
41.28
41.10
7.00
0.38
0.38
max max ± .25 ± .25 ± .25 ± .25 ± .50 ± .25 ± .25 ± .25
± .50
± 1.02 max max
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 30

7.0 ABOUT FIPS

The Federal Information Processing Standard (FIPS) Publication 140-2 is a U.S. Government Computer Security Standard used to accredit cryptographic modules. It is titled 'Security Requirements for Cryptographic Modules (FIPS PUB 140-2)' and is issued by the National Institute of Standards and Technology (NIST).
Purpose
This standard specifies the security requirements that will be satisfied by a cryptographic module utilized within a security system protecting sensitive but unclassified information. The standard provides four increasing, qualitative levels of security: Level 1, Level 2, Level 3 and Level 4. These levels are intended to cover the wide range of potential applications and environments in which cryptographic modules may be employed.
Validation Program
Products that claim conformance to this standard are validated by the Cryptographic Module Validation Program (CMVP) which is a joint effort between National Institute of Standards and Technology (NIST) and the Communications Security Establishment (CSE) of the Government of Canada. Products validated as conforming to FIPS 140-2 are accepted by the Federal agencies of both countries for the protection of sensitive information (United States) or Designated Information (Canada).
In the CMVP, vendors of cryptographic modules use independent, accredited testing laborites to have their modules tested. National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratories perform cryptographic module compliance/conformance testing.
Seagate Enterprise SED
The SED drives referenced in this Product Manual have been validated by CMVP and have been thoroughly tested to satisfy FIPS 140-2 Level 2 requirements. In order to operate in FIPS Approved Mode of Operation, these SEDs require security initialization. For more information, refer to 'Security Rules' section in the 'Security Policy' document uploaded on the NIST website - Cert# 1299: Seagate Secure® Enterprise Self-Encrypting Drives FIPS 140 Module: http://csrc.nist.gov/groups/
STM/cmvp/documents/140-1/140val-all.htm
Security Level 2
Security Level 2 enhances the physical security mechanisms of a Security Level 1 cryptographic module by adding the requirement for tamper-evidence, which includes the use of tamper-evident coatings or seals on removable covers of the module. Tamper-evident coatings or seals are placed on a cryptographic module so that the coating or seal must be bro­ken to attain physical access to the critical security parameters (CSP) within the module. Tamper-evident seals are placed on covers to protect against unauthorized physical access. In addition Security Level 2 requires, at a minimum, role-based authentication in which a cryptographic module authenticates the authorization of an operator to assume a specific role and perform a corresponding set of services.
Figure 10. Example of FIPS tamper evidence labels.
Note. Image is for reference only, may not represent actual drive.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 31

8.0 ABOUT SELF-ENCRYPTING DRIVES

Self-encrypting drives (SEDs) offer encryption and security services for the protection of stored data, commonly known as “protection of data at rest.” These drives are compliant with the Trusted Computing Group (TCG) Enterprise Storage Specifications as detailed in Section 2.3.
The Trusted Computing Group (TCG) is an organization sponsored and operated by companies in the computer, storage and digital communications industry. Seagate’s SED models comply with the standards published by the TCG.
To use the security features in the drive, the host must be capable of constructing and issuing the following two SCSI commands:
• Security Protocol Out
• Security Protocol In
These commands are used to convey the TCG protocol to and from the drive in their command payloads.

8.1 DATA ENCRYPTION

Encrypting drives use one inline encryption engine for each port, employing AES-128 data encryption in Cipher Block Chaining (CBC) mode to encrypt all data prior to being written on the media and to decrypt all data as it is read from the media. The encryption engines are always in operation, cannot be disabled, and do not detract in any way from the performance of the drive.
The 32-byte Data Encryption Key (DEK) is a random number which is generated by the drive, never leaves the drive, and is inaccessible to the host system. The DEK is itself encrypted when it is stored on the media and when it is in volatile temporary storage (DRAM) external to the encryption engine. A unique data encryption key is used for each of the drive's possible16 data bands (see Section 8.5).

8.2 CONTROLLED ACCESS

The drive has two security partitions (SPs) called the "Admin SP" and the "Locking SP." These act as gatekeepers to the drive security services. Security-related commands will not be accepted unless they also supply the correct credentials to prove the requester is authorized to perform the command.

8.2.1 Admin SP

The Admin SP allows the drive's owner to enable or disable firmware download operations (see Section 8.4). Access to the Admin SP is available using the SID (Secure ID) password or the MSID (Makers Secure ID) password.

8.2.2 Locking SP

The Locking SP controls read/write access to the media and the cryptographic erase feature. Access to the Locking SP is available using the BandMasterX or EraseMaster passwords. Since the drive owner can define up to 16 data bands on the drive, each data band has its own password called BandMasterX where X is the number of the data band (0 through 15).

8.2.3 Default password

When the drive is shipped from the factory, all passwords are set to the value of MSID. This 32-byte random value is printed on the drive label and it can be read by the host electronically over the I/O. After receipt of the drive, it is the responsibility of the owner to use the default MSID password as the authority to change all other passwords to unique owner-specified values.

8.3 RANDOM NUMBER GENERATOR (RNG)

The drive has a 32-byte hardware RNG that it is uses to derive encryption keys or, if requested to do so, to provide random numbers to the host for system use, including using these numbers as Authentication Keys (passwords) for the drive’s Admin and Locking SPs.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 32

8.4 DRIVE LOCKING

In addition to changing the passwords, as described in Section 8.2.3, the owner should also set the data access controls for the individual bands.
The variable "LockOnReset" should be set to "PowerCycle" to ensure that the data bands will be locked if power is lost. This scenario occurs if the drive is removed from its cabinet. The drive will not honor any data read or write requests until the bands have been unlocked. This prevents the user data from being accessed without the appropriate credentials when the drive has been removed from its cabinet and installed in another system.
When the drive is shipped from the factory, the firmware download port is locked and the drive will reject any attempt to download new firmware. The drive owner must use the SID credential to unlock the firmware download port before firmware updates will be accepted.

8.5 DATA BANDS

When shipped from the factory, the drive is configured with a single data band called Band 0 (also known as the Global Data Band) which comprises LBA 0 through LBA max. The host may allocate Band1 by specifying a start LBA and an LBA range. The real estate for this band is taken from the Global Band. An additional 14 Data Bands may be defined in a similar way (Band2 through Band15) but before these bands can be allocated LBA space, they must first be individually enabled using the EraseMaster password.
Data bands cannot overlap but they can be sequential with one band ending at LBA (x) and the next beginning at LBA (x+1).
Each data band has its own drive-generated encryption key and its own user-supplied password. The host may change the Encryption Key (see Section 8.6) or the password when required. The bands should be aligned to 4K LBA boundaries.

8.6 CRYPTOGRAPHIC ERASE

A significant feature of SEDs is the ability to perform a cryptographic erase. This involves the host telling the drive to change the data encryption key for a particular band. Once changed, the data is no longer recoverable since it was written with one key and will be read using a different key. Since the drive overwrites the old key with the new one, and keeps no history of key changes, the user data can never be recovered. This is tantamount to an instantaneous data erase and is very useful if the drive is to be scrapped or redispositioned.

8.7 AUTHENTICATED FIRMWARE DOWNLOAD

In addition to providing a locking mechanism to prevent unwanted firmware download attempts, the drive also only accepts download files which have been cryptographically signed by the appropriate Seagate Design Center.
Three conditions must be met before the drive will allow the download operation:
1. The download must be an SED file. A standard (base) drive (non-SED) file will be rejected.
2. The download file must be signed and authenticated.
3. As with a non-SED drive, the download file must pass the acceptance criteria for the drive. For example it must be appli­cable to the correct drive model, and have compatible revision and customer status.

8.8 POWER REQUIREMENTS

The standard drive models and the SED drive models have identical hardware, however the security and encryption portion of the drive controller ASIC is enabled and functional in the SED models. This represents a small additional drain on the 5V supply of about 30mA and a commensurate increase of about 150mW in power consumption. There is no additional drain on the 12V supply. See the tables in Section 6.2 for power requirements on the standard (non-SED) drive models.

8.9 SUPPORTED COMMANDS

The SED models support the following two commands in addition to the commands supported by the standard (non-SED) models as listed in Table 16:
• Security Protocol Out (B5h)
• Security Protocol In (A2h)
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 33

9.0 DEFECT AND ERROR MANAGEMENT

Seagate continues to use innovative technologies to manage defects and errors. These technologies are designed to increase data integrity, perform drive self-maintenance, and validate proper drive operation.
SCSI defect and error management involves drive internal defect/error management and FC system error considerations (errors in communications between the initiator and the drive). In addition, Seagate provides the following technologies used to increase data integrity and drive reliability:
• Background Media Scan (see Section 9.4)
• Media Pre-Scan (see Section 9.5)
• Deferred Auto-Reallocation (see Section 9.6)
• Idle Read After Write (see Section 9.7)
The read error rates and specified storage capacities are not dependent on host (initiator) defect management routines.

9.1 DRIVE INTERNAL DEFECTS/ERRORS

During the initial drive format operation at the factory, media defects are identified, tagged as being unusable, and their locations recorded on the drive primary defects list (referred to as the “P’ list and also as the ETF defect list). At factory format time, these known defects are also reallocated, that is, reassigned to a new place on the medium and the location listed in the defects reallocation table. The “P” list is not altered after factory formatting. Locations of defects found and reallocated during error recovery procedures after drive shipment are listed in the “G” list (defects growth list). The “P” and “G” lists may be referenced by the initiator using the Read Defect Data command.
Details of the SCSI commands supported by the drive are described in the Fibre Channel Interface Manual. Also, more information on the drive Error Recovery philosophy is presented in the Fibre Channel Interface Manual.

9.2 DRIVE ERROR RECOVERY PROCEDURES

When an error occurs during drive operation, the drive, if programmed to do so, performs error recovery procedures to attempt to recover the data. The error recovery procedures used depend on the options previously set in the Error Recovery Parameters mode page. Error recovery and defect management may involve using several SCSI commands described in
the Fibre Channel Interface Manual. The drive implements selectable error recovery time limits required in video
applications.
The error recovery scheme supported by the drive provides a way to control the total error recovery time for the entire command in addition to controlling the recovery level for a single LBA. The total amount of time spent in error recovery for a command can be limited using the Recovery Time Limit bytes in the Error Recovery mode page. The total amount of time spent in error recovery for a single LBA can be limited using the Read Retry Count or Write Retry Count bytes in the Error Recovery mode page.
The drive firmware error recovery algorithms consists of 13 levels for read recoveries and five levels for write. Each level may consist of multiple steps, where a step is defined as a recovery function involving a single re-read or re-write attempt. The maximum level used by the drive in LBA recovery is determined by the read and write retry counts.
Table 5 equates the read and write retry count with the maximum possible recovery time for read and write recovery of individual LBAs. The times given do not include time taken to perform reallocations. Reallocations are performed when the ARRE bit (for reads) or AWRE bit (for writes) is one, the RC bit is zero, and the recovery time limit for the command has not yet been met. Time needed to perform reallocation is not counted against the recovery time limit.
When the RC bit is one, reallocations are disabled even if the ARRE or AWRE bits are one. The drive will still perform data recovery actions within the limits defined by the Read Retry Count, Write Retry Count, and Recovery Time Limit parameters. However, the drive does not report any unrecovered errors.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 34
Table 5 Read and write retry count maximum recovery times [1]
READ RETRY
COUNT
0 51.87 0 23.94
1 59.85 1 35.91
2 203.49 2 39.9
3 231.42 3 51.87
4 295.26 4 79.8
5 327.18 5 (default) 107.73
6 359.10
7 446.88
8 538.65
9 570.57
10 598.50
11 (default) 1,534.97
MAXIMUM RECOVERY TIME PER LBA (CUMULATIVE, MSEC)
WRITE
RETRY COUNT
MAXIMUM RECOVERY TIME PER LBA (CUMULATIVE, MSEC)
[1] These values are subject to change.
Setting these retry counts to a value below the default setting could result in an increased unrecovered error rate which may exceed the value given in this product manual. A setting of zero (0) will result in the drive not performing error recovery.
For example, suppose the Read/Write Recovery page has the RC bit set to 0, read retry count set to 4, and the recovery time limit field (Mode Sense page 01, bytes 10 and 11) set to FF FF hex (maximum). A four LBA Read command is
allowed to take up to 253.11 msec recovery time for each of the four LBAs in the command. If the recovery time limit is
set to 00 C8 hex (200 msec decimal) a four LBA read command is allowed to take up to 200 msec for all error recovery within that command. The use of the Recovery Time Limit field allows finer granularity on control of the time spent in error recovery. The recovery time limit only starts counting when the drive is executing error recovery and it restarts on each command. Therefore, each command’s total recovery time is subject to the recovery time limit. Note: A recovery time limit of 0 will use the drive’s default value of FF FF. Minimum recovery time limit is achieved by setting the Recov­ery Time Limit field to 00 01.

9.3 FC-AL SYSTEM ERRORS

Information on the reporting of operational errors or faults across the interface is given in the Fibre Channel Interface Manual. The FCP Response returns information to the host about numerous kinds of errors or faults. The Receive
Diagnostic Results reports the results of diagnostic operations performed by the drive.
Status returned by the drive to the initiator is described in the Fibre Channel Interface Manual. Status reporting plays a role in
systems error management and its use in that respect is described in sections where the various commands are discussed.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 35

9.4 BACKGROUND MEDIA SCAN

Background Media Scan (BMS) is a self-initiated media scan. BMS is defined in the T10 document SPC-4 available from the T10 committee. BMS performs sequential reads across the entire pack of the media while the drive is idle. In RAID arrays, BMS allows hot spare drives to be scanned for defects prior to being put into service by the host system. On regular duty drives, if the host system makes use of the BMS Log Page, it can avoid placing data in suspect locations on the media. Unreadable and recovered error sites will be logged or reallocated per ARRE/AWRE settings.
With BMS, the host system can consume less power and system overhead by only checking BMS status and results rather than tying up the bus and consuming power in the process of host-initiated media scanning activity.
Since the background scan functions are only done during idle periods, BMS causes a negligible impact to system performance. The first BMS scan for a newly manufactured drive is performed as quickly as possible to verify the media and protect data by setting the “Start time after idle” to 5ms, all subsequent scans begin after 500ms of idle time. Other features that normally use idle time to function will function normally because BMS functions for bursts of 800ms and then suspends activity for 100ms to allow other background functions to operate.
BMS interrupts immediately to service host commands from the interface bus while performing reads. BMS will complete any BMS-initiated error recovery prior to returning to service host-initiated commands. Overhead associated with a return to host­servicing activity from BMS only impacts the first command that interrupted BMS, this results in a typical delay of about 1 ms.

9.5 MEDIA PRE-SCAN

Media Pre-Scan is a feature that allows the drive to repair media errors that would otherwise have been found by the host system during critical data accesses early in the drive’s life. The default setting for Media Pre-Scan is enabled on standard products. Media Pre-Scan checks each write command to determine if the destination LBAs have been scanned by BMS. If the LBAs have been verified, the drive proceeds with the normal write command. If the LBAs have not been verified by BMS, Pre-Scan will convert the write to a write verify to certify that the data was properly written to the disk.
Note. During Pre-Scan write verify commands, write performance may decrease by 50% until Pre-Scan completes.
Write performance testing should be performed after Pre-Scan is complete. This may be checked by reading the BMS status.
To expedite the scan of the full pack and subsequently exit from the Pre-Scan period, BMS will begin scanning immediately when the drive goes to idle during the Pre-Scan period. In the event that the drive is in a high transaction traffic environment and is unable to complete a BMS scan within 24 power on hours BMS will disable Pre-Scan to restore full performance to the system.

9.6 DEFERRED AUTO-REALLOCATION

Deferred Auto-Reallocation (DAR) simplifies reallocation algorithms at the system level by allowing the drive to reallocate unreadable locations on a subsequent write command. Sites are marked for DAR during read operations performed by the drive. When a write command is received for an LBA marked for DAR, the auto-reallocation process is invoked and attempts to rewrite the data to the original location. If a verification of this rewrite fails, the sector is re-mapped to a spare location.
This is in contrast to the system having to use the Reassign Command to reassign a location that was unreadable and then generate a write command to rewrite the data. DAR is most effective when AWRE and ARRE are enabled—this is the default setting from the Seagate factory. With AWRE and ARRE disabled DAR is unable to reallocate the failing location and will report an error sense code indicating that a write command is being attempted to a previously failing location.

9.7 IDLE READ AFTER WRITE

Idle Read After Write (IRAW) utilizes idle time to verify the integrity of recently written data. During idle periods, no active system requests, the drive reads recently written data from the media and compares it to valid write command data resident in the drives data buffer. Any sectors that fail the comparison result in the invocation of a rewrite and auto-reallocation process. The process attempts to rewrite the data to the original location. If a verification of this rewrite fails, the sector is re­mapped to a spare location.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 36

10.0 INSTALLATION

Cheetah 15K.7 FC disk drive installation is a plug-and-play process. There are no jumpers, switches, or terminators on the drive. Simply plug the drive into the host’s 40-pin Fibre Channel backpanel connector (FC-SCA)no cables are required. See Section 11.5 for additional information about this connector.
Use the FC-AL interface to select drive ID and all option configurations for devices on the loop.
If multiple devices are on the same FC-AL and physical addresses are used, set the device selection IDs (SEL IDs) on the backpanel so that no two devices have the same selection ID. This is called the hard assigned arbitrated loop physical address (AL_PA). There are 125 AL_PAs available (see Table 27). If you set the AL_PA on the backpanel to any value other than 0, the device plugged into the backpanel’s SCA connector inherits this AL_PA. In the event you don’t successfully assign unique hard addresses (and therefore have duplicate selection IDs assigned to two or more devices), the FC-AL generates a message indicating this condition. If you set the AL_PA on the backpanel to a value of 0, the system issues a unique soft-assigned physical address automatically.
Loop initialization is the process used to verify or obtain an address. The loop initialization process is performed when power is applied to the drive, when a device is added or removed from the Fibre Channel loop, or when a device times out attempting to win arbitration.
• Set all option selections in the connector prior to applying power to the drive. If you change options after applying power to
the drive, recycle the drive power to activate the new settings.
• It is not necessary to low-level format this drive. The drive is shipped from the factory low-level formatted in 512-byte logi-
cal blocks. You need to reformat the drive only if you want to select a different logical block size.

10.1 DRIVE ID/OPTION SELECTION

All drive options are made through the interface connector (J1). Table 24 provides the pin descriptions for the 40-pin Fibre Channel single connector (J1).

10.2 DRIVE ORIENTATION

The drive may be mounted in any orientation. All drive performance characterizations, however, have been done with the drive in horizontal (discs level) and vertical (drive on its side) orientations, which are the two preferred mounting orientations.

10.3 COOLING

The host enclosure must dissipate heat from the drive. You should confirm that the host enclosure is designed to ensure that the drive operates within the temperature measurement guidelines described in Section 6.4.1. In some cases, forced airflow may be required to keep temperatures at or below the temperatures specified in Section 6.4.1.
If forced air is necessary, possible air-flow patterns are shown in Figure 11. The air-flow patterns are created by fans either forcing or drawing air as shown in the illustrations. Conduction, convection, or other forced air-flow patterns are acceptable as long as the temperature measurement guidelines of Section 6.4.1 are met.
e Air flows in the direction shown (back to front)
or in reverse direction (front to back)
Figure 11. Air flow
Above unit
Under unit
e Air flows in the direction shown or
in reverse direction (side to side)
Above unit
Under unit
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 37

10.4 DRIVE MOUNTING

Mount the drive using the bottom or side mounting holes. If you mount the drive using the bottom holes, ensure that you do not physically distort the drive by attempting to mount it on a stiff, non-flat surface.
The allowable mounting surface stiffness is 80 lb/in (14.0 N/mm). The following equation and paragraph define the allowable mounting surface stiffness:
KxX=F
where K is the mounting surface stiffness (units in lb/in or N/mm) and X is the out-of-plane surface distortion (units in inches or millimeters). The out-of-plane distortion (X) is determined by defining a plane with three of the four mounting points fixed and evaluating the out-of-plane deflection of the fourth mounting point when a known force (F) is applied to the fourth point.
Note. Before mounting the drive in any kind of 3.5-inch to 5.25-inch adapter frame, verify with Seagate Technology that
the drive can meet the shock and vibration specifications given herein while mounted in such an adapter frame. Adapter frames that are available may not have a mechanical structure capable of mounting the drive so that it can meet the shock and vibration specifications listed in this manual.
< 15lb = 67N

10.5 GROUNDING

Signal ground (PCBA) and HDA ground are connected together in the drive and cannot be separated by the user. The equipment in which the drive is mounted is connected directly to the HDA and PCBA with no electrically isolating shock mounts. If it is desired for the system chassis to not be connected to the HDA/PCBA ground, the systems integrator or user must provide a nonconductive (electrically isolating) method of mounting the drive in the host equipment.
Increased radiated emissions may result if you do not provide the maximum surface area ground connection between system ground and drive ground. This is the system designer’s and integrator’s responsibility.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 38

11.0 INTERFACE REQUIREMENTS

This section partially describes the interface requirements as implemented on Cheetah 15K.7 FC drives. Additional
information is provided in the Fibre Channel Interface Manual (part number 100293070).

11.1 FC-AL FEATURES

This section lists the Fibre Channel-specific features supported by Cheetah 15K.7 FC drives.

11.1.1 Fibre Channel link service frames

Table 6 lists the link services supported by Cheetah 15K.7 FC drives.
Table 6 Link services supported
TYPE OF FRAME LINK SERVICE
Basic link service frames Abort Sequence (ABTS)
Basic link service reply frames Basic_Accept (BA_ACC)
Extended link service frames N_Port Login (PLOGI)
Extended link service reply frames Accept (ACC)
Fibre Channel Services Register FC-4 Types (RFT_ID)
Basic_Reject (BA_RJT)
Fabric Login (FLOGI) Logout (LOGO) Process Login (PRLI) Process Logout (PRLO) Read Link Status (RLS)
Fabric Address Notification (FAN) Port Discovery (PDISC) Address Discovery (ADISC)
Third-party Process Logout (TRPLO)
Link Service Reject (LS_RJT)
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 39

11.1.2 Fibre Channel task management functions

Table 7 lists the Fibre Channel SCSI Fibre Channel Protocol (FC SCSI FCP) task management functions supported.
Table 7 Fibre Channel SCSI FCP task management functions
TASK NAME SUPPORTED
Terminate task No
Clear ACA Yes
Target reset Yes
Clear task set Yes
Abort task set Yes

11.1.3 Fibre Channel task management responses

Table 8 lists the FC SCSI FCP response codes returned for task management functions supported.
Table 8 FC SCSI FCP response codes
FUNCTION NAME RESPONSE CODE
Function complete 00
Function not supported 04
Function reject 05
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 40

11.1.4 Fibre Channel port login

Table 9 identifies the required content of the N_Port Login (PLOGI) payload from an initiator.
Table 9 N_Port login (PLOGI) payload
BYTES
0-15 03 00 00 00 09 09 BB BB CF XX FS FS XX XX XX XX Common
16-31 XX XX XX XX PN PN PN PN PN PN PN PN NN NN NN NN
32-35 NN NN NN NN
36-47 XX XX XX XX XX XX XX XX XX XX XX XX Class 1
48-51 XX XX XX XX
52-63 XX XX XX XX XX XX XX XX XX XX XX XX Class 2
64-67 XX XX XX XX
68-79 SO SO IC IC XX XX FS FS XX CS XX XX Class 3
80-83 OS OS XX XX
84-95 XX XX XX XX XX XX XX XX XX XX XX XX Reserved
96-99 XX XX XX XX
100-111 XX XX XX XX XX XX XX XX XX XX XX XX Vendor
112-115 XX XX XX XX Version
X Indicates a four-bit (hex) field is not checked.
x Indicates a single bit is not checked.
BB BB-Credit. This field is not checked. The FC-AL drive uses BB-Credit of zero (0).
CF Common features. This binary field selects the common features requested by the initiator login.
MSB Continuously increasing offset Must = 1
Random relative offset Not checked. Port Login Accept will return a 0—not supported.
Valid version level x
N_Port/F_Port Must = 0, N_Port
Alternate credit model Must = 1
Other bits reserved xxx XX
FS Receive buffer field size. The FS field in the common and Class 3 parameters is checked for the range 128 < FS <
and a multiple of four bytes. For multiple frame sequences, all frames but the last frame of the sequence
2,112 must be this size. Only the receive buffer field size in the Class 3 parameters is used.
PN Port name (initiator’s)—saved with the login parameters. If a change of the port name/AL_PA address association
detected during a Port DISCovery, and implicit logout occurs and the initiator returns a LS_RJT.
is
NN Node name. The node name is not checked or saved by the drive.
SO Service options Class 3 only.
MSB Class valid Must = 1
Intermix x
Stacked connection req. xx
Sequential delivery x
Other bits reserved xxx XX
IC Initiator control
MSB XID reassign xx
Proc Assc 10 or 11 causes the login to be rejected. Other values are
accepted.
Other bits XXX
CS Concurrent sequences Must be a value greater than 0.
OS Open sequences per exchange Must be a value greater than 0.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 41

11.1.5 Fibre Channel port login accept

Table 10 identifies the N_Port Login access payload values.
Table 10 N_Port Login Accept (ACC) payload
BYTES
0-15 02 00 00 00 09 09 00 00 88 00 FS FS 00 FF 00 01 Common
16-31 00 00 01 F4 2P 00 CC CC CC UI UI UI 20 00 CC CC
32-35 CC UI UI UI
36-47 00 00 00 00 00 00 00 00 00 00 00 00 Class 1
48-51 00 00 00 00
52-63 00 00 00 00 00 00 00 00 00 00 00 00 Class 2
64-67 00 00 00 00
68-79 80 00 00 00 00 00 FS FS 00 FF 00 00 Class 3
80-83 00 01 00 00
84-95 00 00 00 00 00 00 00 00 00 00 00 00 Reserved
96-99 00 00 00 00
100-111 00 00 00 00 00 00 00 00 00 00 00 00 Vendor -
112-115 00 00 00 00 Version
Table 3:
CC Bytes (22, 23 and 24) and (30, 31 and 32) are currently factory set to 00 04 CF respectively (subject to change).
FS Receive buffer field size. The drive returns and uses the receive buffer size from the N_Port Login Class 3 receive
buffer.
UI Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and
Node Name fields.
P Byte port identifier field.
0 P_LOGI received on Node.
1 P_LOGI received on Port A.
2 P_LOGI received on Port B.

11.1.6 Fibre Channel Process Login

Table 11 lists the process login payload data.
Table 11 Process Login (PLRI) payload
BYTES
0-15 20 10 00 14 08 00 20 00 XX XX XX XX XX XX XX XX
16-19 00 00 00 22
XXIndicates fields that are not used.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 42

11.1.7 Fibre Channel Process Login Accept

Table 12 lists Cheetah 15K.7 FC process login accept payload data.
Table 12 Process Login Accept (ACC) payload
BYTES
0-15 02 10 00 14 08 00 21 00 00 00 00 00 00 00 00 00
16-31 00 00 00 12

11.1.8 Fibre Channel fabric login

Table 13 lists the fabric login payload from the drive.
Table 13 Fabric Login (FLOGI) payload
BYTES
0-15 04 00 00 00 09 09 00 00 08 00 08 40 00 00 00 00 Common
16-31 00 00 02 F4 2P 00 CC CC CC UI UI UI 02 00 CC CC
32-35 CC UI UI UI
36-47 00 00 00 00 00 00 00 00 00 00 00 00 Class 1
48-51 00 00 00 00
52-63 00 00 00 00 00 00 00 00 00 00 00 00 Class 2
64-67 00 00 00 00
68-79 80 00 00 00 00 00 08 40 00 00 00 00 Class 3
80-83 00 00 00 00
84-95 00 00 00 00 00 00 00 00 00 00 00 00 Reserved
96-99 00 00 00 00
100-111 00 00 00 00 00 00 00 00 00 00 00 00 Vendor -
112-115 00 00 00 00 Version
CC Bytes (22, 23 and 24) and (30, 31 and 32) are currently factory set to 00 04 CF respectively (subject to change).
UI Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and
Node Name fields.
P Port identifier field.
1 FLOGI originated on Port A.
2 FLOGI originated on Port B.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 43

11.1.9 Fibre Channel fabric accept login

Table 14 lists the required content of the Fabric Login Accept (ACC) payload from the fabric.
Table 14 Fabric Login Accept (ACC) payload
BYTES
0-15 02 00 00 00 09 09 BB BB CF XX FS FS R_ A_ T0 V_ Common
16-31 E_ D_ T0 V_ PN PN PN PN PN PN PN PN NN NN NN NN
32-35 NN NN NN NN
36-47 XX XX XX XX XX XX XX XX XX XX XX XX Class 1
48-51 XX XX XX XX
52-63 XX XX XX XX XX XX XX XX XX XX XX XX Class 2
64-67 XX XX XX XX
68-79 SO SO xx xx XX XX FS FS XX xx XX XX Class 3
80-83 OS OS XX XX
84-95 XX XX XX XX XX XX XX XX XX XX XX XX Reserved
96-99 XX XX XX XX
100-111 XX XX XX XX XX XX XX XX XX XX XX XX Vendor -
112-115 XX XX XX XX Version
X Indicates a four-bit (hex) field is not checked.
x Indicates a single bit is not checked.
BB BB-Credit. This field is not checked. The FC-AL drive uses BB-Credit of zero (0).
CF Common features. This binary field selects the common features requested by the fabric login.
MSB Continuously increasing offset x
Random relative offset x
Valid version level x
N_Port/F_Port Must = 1, F_Port
Alternate credit model Must = 1
Other bits reserved xxx XX
FS Receive buffer field size. The FS field in the common and Class 3 parameters is checked for the range 128 < FS <
2,112 and a multiple of four bytes. The receive buffer field size in the Class 3 parameters is used. The drive uses the lower FS of Fabric Login Accept or N_Port Login when sending frames to an initiator.
PN Port Name. The fabric port name is saved with the login parameters. If a change of the port name is detected dur-
ing a FAN, an implicit logout occurs and a LS_RJT is returned to the fabric.
NN Node Name. The drive does not check or save the node name.
SO Service Options—Class 3 only.
MSB Class valid Must = 1
Intermix x
Stacked connection req. xx
Sequential delivery Must = 1
Other bits reserved xxx XX
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 44

11.1.10 Fibre Channel Arbitrated Loop options

Table 15 lists the FC-AL options supported by Cheetah 15K.7 FC drives.
Table 15 FC-AL options supported
OPTION SUPPORTED
OPEN Half Duplex Accepted from another device.
OPEN Full Duplex Sent to open another device. Accepted from another device.
Private Loop Yes
Public Loop Yes
Old Port State No
Loop Position Yes
Loop Position Report Yes

11.2 DUAL PORT SUPPORT

Cheetah 15K.7 FC drives have two independent FC-AL ports. These ports may be connected on independent loops or on the same loop. Port A and Port B may be connected in any order or combination.
• If both ports are connected on independent loops and hard addressing is used, the drive interface address is selected
through the interface connector, both ports will seek the same loop address. If no conflict, both ports will have the same loop address.
• If both ports are connected in the same loop and hard addressing is used, at least one port will attempt taking a soft
address to prevent an address conflict.
Note. When a Cheetah 15K.7 FC drive is connected in loops with previous Seagate FC drive products:
Barracuda 4LP FC (ST32171FC, ST34371FC, and ST34571FC) Barracuda 9FC (ST19171FC) Cheetah 4LP FC (ST34501FC) Cheetah 9FC (ST19101FC)
the connection of Port A and B for these products must follow the requirements in their product manuals.
Subject to buffer availability, the Cheetah 15K.7 FC drives support:
• Concurrent port transfers—The drive supports receiving transfers on both ports at the same time when the ports are on
independent loops.
• Full duplex—The drive supports sending FCP_Data, FCP_RSP, FCP_XFR_RDY and ELS transfers while receiving frames
on both ports.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 45

11.3 SCSI COMMANDS SUPPORTED

Table 16 lists the SCSI commands supported by Cheetah 15K.7 FC drives.
Table 16 Supported commands
Executable state of standard SCSI commands in the presence of LBA banding (applies to SED models only)
Affected LBA
User Data Command code
00h Y Test unit ready Y N Executable Executable
01h Y Rezero unit Y N Executable Executable
03h Y Request sense Y N Executable Executable
04h Y Format unit [1] Y Y Executable Check Condition
07h Y Reassign blocks N Y Executable Check Condition
08h Y Read N Y Executable Check Condition
0Ah Y Write N Y Executable Check Condition
0Bh Y Seek N N Executable Executable
12h Y Inquiry Y N Executable Executable
15h Y Mode select (same pages as Mode
16h Y Reserve Y N Executable Executable
17h Y Release Y N Executable Executable
18h N Copy
1Ah Y Mode sense Y N Executable Executable
Supported (Y/N) [4] Command name
Y Extended sense
Y Field pointer bytes
Y Actual retry count bytes
Y Vital product data page (00h)
Y Unit serial number page (80h)
Y Implemented operating def. page
(81h)
Y Device Identification page (83h)
Y Firmware numbers page (C0h)
Y Date code page (C1h)
Y Jumper settings page (C2h)
Y Device Behavior page (C3h)
Sense command shown below) [3]
N 3rd party reserved
N Extent reservation
Y Unit attention page (00h)
Y Error recovery page (01h)
Y Disconnect/reconnect control (page
02h)
Y Format page (03h)
Y Rigid disk drive geometry page
(04h)
Y Verify error recovery page (07h)
Y Caching parameters page (08h)
Y Control mode page (0Ah)
Y Fibre Channel Interface Control
page (19h)
Y Power control page (1Ah)
Affects entire Drive (Y/N)
Y N Executable Executable
Accessed
(Y/N)
Unlocked ReadLock=Write Lock=False
Affected LBA Locked ReadLock=Write Lock=True
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 46
Table 16 Supported commands (continued)
Executable state of standard SCSI commands in the presence of LBA banding (applies to SED models only)
Affected LBA
User Data Command code
1Bh Y Start unit/stop unit Y Y Executable Executable
1Ch Y Receive diagnostic results Y N Executable Executable
1Dh Y Send diagnostics page Y N Executable Executable
25h Y Read capacity Y N Executable Executable
28h Y Read extended
2Ah Y Write extended
2Bh Y Seek extended
2Eh Y Write and verify N Y Executable Check Condition
2Fh Y Verify (10) (BYTCHK = 0) N Y Executable Executable
30h N Search data high
31h N Search data equal
32h N Search data low
33h N Set limits
34h N Prefetch N Y Executable Check Condition
35h Y Synchronize cache N Y Executable Executable
36h N Lock-unlock-cache
37h Y Read defect data Y N Executable Executable
39h N Compare
3Ah N Copy and verify
3Bh Y Write buffer N Y Check Condition Check Condition
Supported (Y/N) [4] Command name
Y Information exceptions control page
(1Ch)
Y Background Scan mode subpage
(01h)
Y Supported diagnostics pages
Y Translate page
Y Enclosure services page
Y Supported diagnostics pages
Y Translate page
Y Disable page out
Y Force unit access
N Relative address
Y Disable page out
Y Force unit access
N Relative address
Y Disable page out
Y Byte check
N Relative address
Y Verify (10) (BYTCHK = 1) N Y Executable Check Condition
Y Disable page out
Y Byte check
N Relative address
Affects entire Drive (Y/N)
(all modes except modes 4h - 7h, 0Eh, and 0Fh)
Y N Executable Executable
(modes 4h - 7h, 0Eh, and 0Fh)
Accessed
(Y/N)
Unlocked ReadLock=Write Lock=False
Affected LBA Locked ReadLock=Write Lock=True
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 47
Table 16 Supported commands (continued)
Executable state of standard SCSI commands in the presence of LBA banding (applies to SED models only)
Affected LBA
User Data Command code
3Ch Y Read buffer (Mode 1Ch -- Error
3Ch Y Read buffer Y N Check Condition Check Condition
3Eh Y Read long N Y Check Condition Check Condition
3Fh Y Write long (10) (WR_UNCOR = 0) N Y Check Condition Check Condition
40h N Change definition Y N Executable Check Condtion
41h Y Write same (10) N Y Executable Check Condition
42-4Bh N Not used
4Ch Y Log Select Y N Executable Executable
4Dh Y Log Sense Y N Executable Executable
4E-4Fh N Not used
50h N XD write
51h N XP write
52h N XD read
Supported (Y/N) [4] Command name
Y Write combined header and data
mode (0)
Y Write data mode (2)
N Download microcode mode (4)
Y Download microcode and save
modes (5)
N Download microcode with offsets
mode (6)
Y Download microcode with offsets
and save mode (7)
Y Firmware download option [2]
Retrieval Mode)
Y Read combined header and data
mode (0)
Y Read data mode (2)
Y Read descriptor mode (3)
Write long (10) (WR_UNCOR = 1) N Y Executable Check Condition
N PBdata
N LBdata
Y Support Log page (00h)
Y Write Error Counter page (02h)
Y Read Error Counter page (03h)
N Read Reverse Error Counter page
(04h)
Y Verify Error Counter page (05h)
Y Non-medium Error Counter page
(06h)
Y Temperature page (0Dh)
N Application Client page (0Fh)
Y Self Test Results page (10h)
Y Background Medium Scan page
(15h)
Y Cache Statistics Counter page
(37h)
Y Factory Log page (3Eh)
Affects entire Drive (Y/N)
Y N Executable Executable
Accessed
(Y/N)
Unlocked ReadLock=Write Lock=False
Affected LBA Locked ReadLock=Write Lock=True
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 48
Table 16 Supported commands (continued)
Executable state of standard SCSI commands in the presence of LBA banding (applies to SED models only)
Affected LBA
User Data Command code
53-54h N Not used
55h Y Mode Select (10) [3]
56h Y Reserved (10)
57h Y Released (10)
58-59h N Not used
5Ah Y Mode Sense (10) [3]
5B-5Dh N Not used
5E A Persistent reserve in Y N Executable Executable
5F A Persistent reserve out Y N Executable Executable
60-7Eh N Not used
7Fh Y (PI only) Write Same (32) N Y Executable Check Condition
7Fh Y (PI only) Verify (32) (BYTCHK = 0) N Y Executable Executable
7Fh Y (PI only) Verify (32) (BYTCHK = 1) N Y Executable Check Condition
80h N XD write extended
81h N Rebuild
82h N Regenerate
83-8Eh N Not used
8Fh Y (PI only) Verify (16) (BYTCHK = 0) N Y Executable Executable
8Fh Y (PI only) Verify (16) (BYTCHK = 1) N Y Executable Check Condition
93h Y (PI only) Write same (16) N Y Executable Check Condition
A0h Y Report LUNS Y N Executable Executable
A2h Y
A3h Y
B5h Y
C0-DFh N Not used
EO-FFh N Not used
Supported (Y/N) [4] Command name
Y 3rd party reserve
N Extent reservation
Security Protocol In Y N Executable Executable
(SED only)
Report Device Identifier Y N Executable Executable
(SED only)
Security Protocol Out Y N Executable Executable
(SED only)
Affects entire Drive (Y/N)
Accessed
(Y/N)
Unlocked ReadLock=Write Lock=False
Affected LBA Locked ReadLock=Write Lock=True
[1] Cheetah 15K.7 FC drives can format to 512, 520, 524 or 528 bytes per logical block.
[2] Warning. Power loss during flash programming can result in firmware corruption. This usually makes the drive inopera-
ble. [3] Reference Mode Sense command 1Ah for mode pages supported. [4] Y = Yes. Command is supported.
N = No. Command is not supported.
A = Support is available on special request.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 49

11.3.1 Inquiry data

Table 17 lists the Inquiry command data that the drive should return to the initiator per the format given in the Fibre Channel Interface Manual.
Table 17 Cheetah 15K.7 FC inquiry data
BYTES DATA (HEX)
0-15 00 00 xx** 12 8B 00 PP 02 53 45 41 47 41 54 45 20 Vendor ID
16-31 [53 54 33 36 30 30 30 35 37 46 43]120 20 20 20 20 Product ID
32-47 R# R# R# R# S# S# S# S# S# S# S# S# 00 00 00 00
48-63 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
64-79 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
80-95 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
96-111 00 43 6F 70 79 72 69 67 68 74 20 28 63 29 20 32* *Copyright
112-127 30* 30* 39* 20 53 65 61 67 61 74 65 20 41 6C 6C 20 notice
128-143 72 69 67 68 74 73 20 72 65 73 65 72 76 65 64 20
* Copyright year (changes with actual year).
** SCSI Revision support. Refer to the SPC release documentation for definitions.
PP 50 = Inquiry data for an Inquiry command received on Port A.
70 = Inquiry data for an Inquiry command received on Port B. R# Four ASCII digits representing the last four digits of the product firmware release number. S# Eight ASCII digits representing the eight digits of the product serial number. [ ] Bytes 18 through 26 reflect model of drive in hex format.

11.3.2 Mode Sense data

The Mode Sense command provides a way for the drive to report its operating parameters to the initiator. The drive maintains four sets of mode parameters:
1. Default values
Default values are hard-coded in the drive firmware stored in flash E-PROM (nonvolatile memory) on the drive’s PCB. These default values can be changed only by downloading a complete set of new firmware into the flash E-PROM. An initiator can request and receive from the drive a list of default values and use those in a Mode Select command to set up new current and saved values, where the values are changeable.
2. Saved values
Saved values are stored on the drive’s media using a Mode Select command. Only parameter values that are allowed to be changed can be changed by this method. Parameters in the saved values list that are not changeable by the Mode Select command get their values from default values storage.
When power is applied to the drive, it takes saved values from the media and stores them as current values in volatile memory. It is not possible to change the current values (or the saved values) with a Mode Select command before the drive achieves operating speed and is “ready.” An attempt to do so results in a “Check Condition” status.
On drives requiring unique saved values, the required unique saved values are stored into the saved values storage location on the media prior to shipping the drive. Some drives may have unique firmware with unique default values also.
On standard OEM drives, the saved values are taken from the default values list and stored into the saved values stor­age location on the media prior to shipping.
3. Current values
Current values are volatile values being used by the drive to control its operation. A Mode Select command can be used to change the values identified as changeable values. Originally, current values are installed from saved or default val­ues after a power on reset, hard reset, or Bus Device Reset message.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 50
4. Changeable values
Changeable values form a bit mask, stored in nonvolatile memory, that dictates which of the current values and saved values can be changed by a Mode Select command. A one (1) indicates the value can be changed. A zero (0) indicates the value is not changeable. For example, in Table 18, refer to Mode page 81, in the row entitled “CHG.” These are hex numbers representing the changeable values for Mode page 81. Note in columns 5 and 6 (bytes 04 and 05), there is 00h which indicates that in bytes 04 and 05 none of the bits are changeable. Note also that bytes 06, 07, 09, 10, and 11 are not changeable, because those fields are all zeros. In byte 02, hex value FF equates to the binary pattern 11111111. If there is a zero in any bit position in the field, it means that bit is not changeable. Since all of the bits in byte 02 are ones, all of these bits are changeable.
The changeable values list can only be changed by downloading new firmware into the flash E-PROM.
Note. Because there are often several different versions of drive control firmware in the total population of drives in the
field, the Mode Sense values given in the following tables may not exactly match those of some drives.
The following tables list the values of the data bytes returned by the drive in response to the Mode Sense command pages
for SCSI implementation (see the Fibre Channel Interface Manual ).
Definitions:
SAV = Current saved value. DEF = Default value. Standard OEM drives are shipped configured this way. CHG = Changeable bits; indicates if default value is changeable.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 51
Table 18 Mode Sense data saved, default and changeable values for ST3600057FC drives
MODE DATA HEADER: 00 be 00 10 00 00 00 08
MODE PAGES:
DEF 81 0a c0 0b ff 00 00 00 05 00 ff ff CHG 81 0a ff ff 00 00 00 00 ff 00 ff ff
DEF 82 0e 80 80 00 00 00 00 00 00 01 3a 00 00 00 00 CHG 82 0e ff ff 00 00 00 00 00 00 ff ff 00 00 00 00
DEF 83 16 bb d0 00 00 00 00 03 80 04 c4 02 00 00 01 00 c0 00 4c 40 00 00 00 CHG 83 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 84 16 01 8a 9a 08 00 00 00 00 00 00 00 00 00 00 00 00 00 00 3a a7 00 00 CHG 84 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 87 0a 00 0b ff 00 00 00 00 00 ff ff CHG 87 0a 0f ff 00 00 00 00 00 00 ff ff
DEF 88 12 14 00 ff ff 00 00 ff ff ff ff 80 20 00 00 00 00 00 00 CHG 88 12 a5 00 00 00 ff ff ff ff 00 00 20 00 00 00 00 00 00 00
DEF 8a 0a 02 00 00 00 00 00 00 00 19 00 CHG 8a 0a 03 f0 00 00 00 00 00 00 00 00
DEF 99 06 00 00 00 00 00 00 CHG 99 06 00 ff 00 00 00 00
DEF 9a 0a 00 02 00 00 00 05 00 00 8c a0 CHG 9a 0a 00 03 ff ff ff ff 00 00 00 00
DEF 9c 0a 10 00 00 00 00 00 00 00 00 01 CHG 9c 0a 9d 0f ff ff ff ff ff ff ff ff
DEF dc 01 00 0c 01 01 00 18 00 18 00 00 00 00 00 00 CHG dc 01 00 0c 00 01 ff ff ff ff 00 00 00 00 00 00
DEF 80 06 00 80 0f 00 00 00 CHG 80 06 b7 c0 8f 00 00 00
READ CAPACITY DATA: READ BUFFER 0 1 2 3 4 5 6 7 8 9 A B C D E F ASCII
000000: 45 DD 2F AF 00 00 02 00 __ __ __ __ __ __ __ __ E./....
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 52
Table 19 Mode Sense data default and changeable values for ST3450857FC drives
MODE DATA HEADER: 00 be 00 10 00 00 00 08
BLOCK DESCRIPTOR: 34 65 f8 70 00 00 02 00
MODE PAGES:
DEF 81 0a c0 0b ff 00 00 00 05 00 ff ff CHG 81 0a ff ff 00 00 00 00 ff 00 ff ff
DEF 82 0e 80 80 00 00 00 00 00 00 01 3a 00 00 00 00 CHG 82 0e ff ff 00 00 00 00 00 00 ff ff 00 00 00 00
DEF 83 16 bb d0 00 00 00 00 03 80 04 c4 02 00 00 01 00 c0 00 4c 40 00 00 00 CHG 83 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 84 16 01 8a 9a 06 00 00 00 00 00 00 00 00 00 00 00 00 00 00 3a a7 00 00 CHG 84 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 87 0a 00 0b ff 00 00 00 00 00 ff ff CHG 87 0a 0f ff 00 00 00 00 00 00 ff ff
DEF 88 12 14 00 ff ff 00 00 ff ff ff ff 80 20 00 00 00 00 00 00 CHG 88 12 a5 00 00 00 ff ff ff ff 00 00 20 00 00 00 00 00 00 00
DEF 8a 0a 02 00 00 00 00 00 00 00 12 c0 CHG 8a 0a 03 f0 00 00 00 00 00 00 00 00
DEF 99 06 00 00 00 00 00 00 CHG 99 06 00 ff 00 00 00 00
DEF 9a 0a 00 02 00 00 00 05 00 00 8c a0 CHG 9a 0a 00 03 ff ff ff ff 00 00 00 00
DEF 9c 0a 10 00 00 00 00 00 00 00 00 01 CHG 9c 0a 9d 0f ff ff ff ff ff ff ff ff
DEF dc 01 00 0c 01 01 00 18 00 18 00 00 00 00 00 00 CHG dc 01 00 0c 00 01 ff ff ff ff 00 00 00 00 00 00
DEF 80 06 00 80 0f 00 00 00 CHG 80 06 b7 c0 8f 00 00 00
READ CAPACITY DATA: READ BUFFER 0 1 2 3 4 5 6 7 8 9 A B C D E F ASCII
000000: 34 65 F8 6F 00 00 02 00 __ __ __ __ __ __ __ __
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 53
Table 20 Mode Sense data default and changeable values for ST3300657FC drives
MODE DATA HEADER: 00 be 00 10 00 00 00 08
BLOCK DESCRIPTOR: 22 ec b2 5c 00 00 02 00
MODE PAGES:
DEF 81 0a c0 0b ff 00 00 00 05 00 ff ff CHG 81 0a ff ff 00 00 00 00 ff 00 ff ff
DEF 82 0e 80 80 00 00 00 00 00 00 01 3a 00 00 00 00 CHG 82 0e ff ff 00 00 00 00 00 00 ff ff 00 00 00 00
DEF 83 16 bb d0 00 00 00 00 03 80 04 c4 02 00 00 01 00 c0 00 4c 40 00 00 00 CHG 83 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 84 16 01 8a 9a 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 3a a7 00 00 CHG 84 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
DEF 87 0a 00 0b ff 00 00 00 00 00 ff ff CHG 87 0a 0f ff 00 00 00 00 00 00 ff ff
DEF 88 12 14 00 ff ff 00 00 ff ff ff ff 80 20 00 00 00 00 00 00 CHG 88 12 a5 00 00 00 ff ff ff ff 00 00 20 00 00 00 00 00 00 00
DEF 8a 0a 02 00 00 00 00 00 00 00 0c 80 CHG 8a 0a 03 f0 00 00 00 00 00 00 00 00
DEF 99 06 00 00 00 00 00 00 CHG 99 06 00 ff 00 00 00 00
DEF 9a 0a 00 02 00 00 00 05 00 00 8c a0 CHG 9a 0a 00 03 ff ff ff ff 00 00 00 00
DEF 9c 0a 10 00 00 00 00 00 00 00 00 01 CHG 9c 0a 9d 0f ff ff ff ff ff ff ff ff
DEF dc 01 00 0c 01 01 00 18 00 18 00 00 00 00 00 00 CHG dc 01 00 0c 00 01 ff ff ff ff 00 00 00 00 00 00
DEF 80 06 00 80 0f 00 00 00 CHG 80 06 b7 c0 8f 00 00 00
READ CAPACITY DATA: READ BUFFER 0 1 2 3 4 5 6 7 8 9 A B C D E F ASCII
000000: 22 EC B2 5B 00 00 02 00 __ __ __ __ __ __ __ __
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 54

11.4 MISCELLANEOUS OPERATING FEATURES AND CONDITIONS

Table 21 lists various features and conditions. A “Y” in the support column indicates the feature or condition is supported. An “N” in the support column indicates the feature or condition is not supported.
Table 21 Miscellaneous features
SUPPORTED FEATURE OR CONDITION
Y FC-AL selective reset (LIP Reset)
N Automatic contingent allegiance
N Asynchronous event notification
N Synchronized (locked) spindle operation
Y Segmented caching
N Zero latency read
Y Queue tagging (up to 128 queue tags supported)
Y Deferred error handling
Y Parameter rounding (controlled by Round bit in Mode Select page 0)
Y Reporting actual retry count in Extended Sense bytes 15, 16, and 17
N Adaptive caching
Y SMP = 1 in Mode Select command needed to save RPL and rotational offset bytes
Table 22 Miscellaneous status
SUPPORTED STATUS
Y Good
Y Check condition
Y Condition met/good
Y Busy
Y Intermediate/good
Y Intermediate/condition met/good
Y Reservation conflict
Y Task set full
N ACA active
N ACA active, faulted initiator
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 55

11.5 FC-AL PHYSICAL INTERFACE

Figure 12 shows the location of the J1 Fibre Channel single connection attachment (FC-SCA). Figure 14 provides the dimensions of the FC-SCA connector.
Details of the physical, electrical, and logical characteristics are provided within this section. The operational aspects of
Seagate’s Fibre Channel drives are provided in the Fibre Channel Interface Manual..
J1 interface connector
Figure 12. Physical interface

11.5.1 Physical characteristics

This section defines physical interface connector.
11.5.1.1 Physical description
FIbre Channel drives may be connected in a loop together or with other compatible FC-AL devices. A maximum of 127 devices may have addresses; however, one of the addresses is reserved for a fabric port switch device. This means 126 addresses are available for FC-AL devices. More FC-AL compatible devices may physically reside on the loop, but they will not be functional because they would not be able to obtain valid addresses.
Port bypass circuits (PBCs) allow devices to be inserted into unpopulated locations or removed from the loop with loop operation recovery after a brief interruption. These PBCs are located external to the FC-AL device. Figure 13 shows the relationship between the PBC and FC-AL device.
Port Bypass
Circuit
From Previous
Port Bypass
Circuit N 1
Drive N 1
Drive
MUX
Select
SerialInSerial
Drive N
Out
To Next
Drive
Port Bypass
Circuit N 1
Drive N 1
Figure 13. Port bypass circuit physical interconnect
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 56

11.5.2 Connector requirements

Table 23 Recommended mating SCA part numbers
PART DESCRIPTION POSITIONS PART NUMBER FEATURES
AMP Vertical (SCA sequence) 40 787317-1
Berg 40 71781
Methode 40 512-220-91-101N
Molex 40 717431040
With polarization
With polarization
With polarization
With polarization
The FC-AL SCA device connector is illustrated in Figure 14.
1.618 ± .003 in
(41.1 ± 0.08 mm)
Pin 20
Pin 40
.64 in
(16.24 mm)
1.28 in
(32.47 mm)
1.618 ± .003 in
(41.10 ± 0.08 mm)
1.492 ± .009 in
(37.90 ± 0.24 mm)
Mating end Housing
Pin 1
Pin 21
0.264 .007 in .010 in
(6.71 0.18 mm)
( 0.25 mm)
0.197 ± .003 in
(5.00 ± .08 mm)
0.226 in
(6.50 mm)
2 places
min.
0.394 ± .004 in
(10.0 ± 0.10 mm)
0.039 in
(0.75 mm)
min.
0.024 in
(0.60 mm)
0.079 ± .010 in (2.00 ± .25 mm)
min.
(initial point
of contact)
.05 in
(1.27 mm)
typ.
Contact (typ.)
.025 in (0.635 mm)
0.106 ± .010 in
(2.70 ± 0.25 mm)
(1.30 ± 0.16 mm)
Figure 14. FC-AL SCA device connector dimensions

11.5.3 Electrical description

Fibre Channel drives use the FC-SCA connector for:
• DC power
• FC-AL interface
• Drive select (device identification)
• Option selection
• Enclosure Services interface
This 40-pin connector is designed to plug directly into a backpanel. External cables are not required.
0.060 ± .010 in
(1.52 ± 0.25 mm)
0.051 ± .006 in
2 places
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 57

11.5.4 Pin descriptions

This section provides a pin-out of the FC-SCA and a description of the functions provided by the pins.
Table 24 FC-SCA pin descriptions
PI
SIGNAL NAME SIGNAL TYPE PIN SIGNAL NAME SIGNAL TYPE
N
1* -EN bypass port A Low Voltage TTL out-
21 12 Volts charge
put
2* 12 Volts 22 Ground
3* 12 Volts 23 Ground
4* 12 Volts 24* +Port A_in FC Diff. input pair
5* -Parallel ESI 25* -Port A_in
6* Ground
[1]
26 Ground
7* Active LED out Open collector out 27* +Port B_in FC Diff. input pair
8* Reserved 28* -Port B_in
9* Start_1
10*Start_2
11*-EN bypass port B Low Voltage TTL out-
[2]
[2]
TTL input 29 Ground
TTL input 30* +Port A_out FC Diff. output pair
31* -Port A_out
put
12*SEL_6 TTL input/output 32 Ground
13*SEL_5 TTL input/output 33* +Port B_out FC Diff. output pair
14*SEL_4 TTL input 34* -Port B_out
15*SEL_3 TTL input/output 35 Ground
16*Fault LED out Open collector out 36 SEL_2 TTL input/output
17*DEV_CTRL_CODE_2
]
2
18*DEV_CTRL_CODE_1
2]
19*5 Volts 39 DEV_CTRL_CODE_0
[
TTL input 37 SEL_1 TTL input/output
[
TTL input 38 SEL_0 TTL input/output
[
2
TTL input
20*5 Volts 40 5 Volts charge
*Short pins in mating backpanel connector.
[1] This pin may be connected to external logic to detect the presence of the drive. The drive connects this pin to the com-
mon ground.
[2] Pins 9, 10, 17, 18, and 39 are option select pins and are tied high by the drive circuitry. The preferred electrical connec-
tion at the backplane is either open or grounded (open for the ‘1’ setting, grounded for the ‘0’ setting). Alternatively, these pins may be driven by a 3.3V logic device, pulled up to 3.3V through a pull-up resistor (recommended size of 10k ohm), or grounded through some other means.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 58

11.5.5 FC-AL transmitters and receivers

A typical FC-AL differential copper transmitter and receiver pair is shown in Figure 15. The receiver is required to provide the AC coupling to eliminate ground shift noise.
TX
Transmitter
100
TY
Figure 15. FC-AL transmitters and receivers
Differential
Transfer Medium
.01
.01
RX
Receiver
100
RY

11.5.6 Power

Power is supplied through the FC-SCA with support for +5 volts and +12 volts. All of the voltage pins in the drive connector are the same length.
Four 12 volt pins provide +12 volt power to the drive. The current return for the +12 volt power supply is through the common ground pins. The supply current and return current must be distributed as evenly as possible among the pins. The maximum current typically occurs while the drive motor is starting.
Three 5 volt pins provide logic power to the drive. The current return for the +5 volt power supply is through the common ground pins. Distribute supply and return current as evenly as possible among the voltage and ground pins.
The mating connector pins use shorter contacts to achieve power surge reductions and to aid in “hot plugging” the drives. There are longer voltage contacts in the connector to enable the drive filter capacitors to charge. Current to the drive through the long charge pins is limited by the system in which the drive operates. Three of the +12 volt pins are shorter to allow capacitive pre-charging through the longer +12 volt charge pin. Two of the +5 volt pins are shorter to allow capacitive precharging through the longer +5 volt charge pin.

11.5.7 Fault LED Out

The Fault LED Out signal is driven by the drive when:
• the drive detects failure of both ports
• the drive detects an internal failure
• the drive receives the appropriate fault LED command from the host
The Fault LED Out signal is designed to pull down the cathode of an LED. The anode is attached to the proper +5 volt supply through an appropriate current-limiting resistor. The LED and the current-limiting resistor are external to the drive.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 59

11.5.8 Active LED Out

The Active LED Out signal is driven by the drive as indicated in Table 25.
Table 25 Active LED Out conditions
NORMAL COMMAND ACTIVITY LED STATUS
Spun down and no activity Slow blink (20% on and 80% off a 2 sec cycle)
Spun down and activity (command executing) On
Spun up and no activity On
Spun up and activity (command executing) Off
Spinning up or down Blinks steadily (50% on and 50% off)
Format in progress, each cylinder change Toggles on/off
The Active LED Out signal is designed to pull down the cathode of an LED. The anode is attached to the proper +5 volt supply through an appropriate current limiting resistor. The LED and the current limiting resistor are external to the drive.

11.5.9 Enable port bypass signals

The – Enable Bypass Port A (– EN BYP Port A) and – Enable Bypass Port B (– EN BYP Port B) signals control the port bypass circuits (PBC) located external to the disk drive. The PBC allows a loop to remain functional in the event of a drive failure or removal. When these signals are active, low, the PBC bypasses the drive on the associated port. When an Enable Bypass signal is active, the corresponding Port Bypass LED signal in connector J1 is driven low by the disk drive. A pull down resistor, 1K, located with the PBC should be used to insure the bypass is enabled if the disk drive is not installed.
The Enable Bypass signal is active under failing conditions within the drive, on detection of the Loop Port Bypass primitive sequence, or on removal of the drive. In the bypass state the drive continues to receive on the inbound fibre. Enable Bypass may be deactivated by detection of a Loop Port Enable primitive sequence if the drive has completed self-test and a hardware failure is not present.
Failure modes detected by the disk drive that will enable bypass include:
• Transmitter/receiver wrap test failure
• Loss of receive clock
• Loss of transmission clock
• Drive interface hardware error
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 60

11.5.10 Motor start controls

The drive’s motor is started according to the Start_1 and Start_2 signals described in Table 26. The state of these signals can be wired into the backplane socket or driven by logic on the backplane.
Table 26 Motor start control signals
CASE START_2 START_1 MOTOR SPIN FUNCTION
1 Low Low Motor spins up at DC power on.
2 High Low Motor spins up only when SCSI Start command is received.
3 Low High Motor spins up after a delay of 12 seconds times the modulo 8 value
4 High High The drive will not spin up.
of the numeric SEL ID of the drive from DC power on.

11.5.11 SEL_6 through SEL_0 ID lines

The SEL_6 through SEL_0 ID lines determine drive address, and, optionally, for an Enclosure Services Interface. When the Parallel ESI line is high, the enclosure backpanel must provide address information on the SEL line. Refer to Table 27 for a mapping of SEL to FC-AL physical addresses (AL_PA). You can think of the SEL lines as the equivalent of a backpanel logic plug. The drives does not provide pull up resistors on these lines. The backpanel is required to provide high and low inputs to the SEL_ID lines per the specifications in table 29 on page 63.
Note. Table 27 gives AL_PA values for each SEL value. The first entry in the table is SEL_ID 00. The last entry is
SEL_ID 7D. SEL_ID 7E is AL_PA 00 which is not valid for an NL_Port, so is not included in the table. Also, SEL_ID 7Fh does map to a valid AL_PA; however, this value signals the drive that physical addresses are not being assigned using the SEL lines and that a “soft” address will be determined by FC-AL loop initialization.
When the Parallel ESI line is low, the enclosure backpanel logic switches to ESI mode if supported. There are two modes of ESI, seven bits of enclosure status and a bidirectional mode. ESI support and the mode are determined by the drive using a
discovery process. Refer to the Fibre Channel Interface Manual for a description of ESI operation.
11.5.11.1Parallel Enclosure Services Interface (ESI)
The parallel ESI line is an output from the drive. This line provides the enclosure with an indication of the present function of the SEL lines. A high level, the default state, indicates the drive requires address information on the SEL lines. A low level indicates the drive is attempting an ESI transfer. The enclosure may not support ESI on any or all drive locations. It may only
support the address function. Support of ESI is discovered by the drive. Refer to the Fibre Channel Interface Manual for a
description of ESI operations.
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 61
Table 27 AL_PA values
AL_PA (hex)
SEL ID (hex)
Setting (dec)
AL_PA (hex)
SEL ID (hex)
Setting (dec)
AL_PA (hex)
SEL ID (hex)
Setting (dec)
EF 00 00 A3 2B 43 4D 56 86
E8 01 01 9F 2C 44 4C 57 87
E4 02 02 9E 2D 45 4B 58 88
E2 03 03 9D 2E 46 4A 59
89
E1 04 04 9B 2F 47 49 5A 90
E0 05 05 98 30 48 47 5B 91
DC 06 06 97 31 49 46 5C 92
DA 07 07 90 32 50 45 5D 93
D9 08 08 8F 33 51 43 5E 94
D6 09 09 88 34 52 3c 5F 95
D5 0A 10 84 35 53 3A 60 96
D4 0B 11 82 36 54 39 61 97
D3 0C 12 81 37 55 36 62 98
D2 0D 13 80 38 56 35 63 99
D1 0E 14 7C 39 57 34 64 100
CE 0F 15 7A 3A 58 33 65 101
CD 10 16 79 3B 59 32 66 102
CC 11 17 76 3C 60 31 67 103
CB 12 18 75 3D 61 2E 68 104
CA 13 19 74 3E 62 2D 69 105
C9 14 20 73 3F 63 2C 6A 106
C7 15 21 72 40 64 2B 6B 107
C6 16 22 71 41 65 2A 6C 108
C5 17 23 6E 42 66 29 6D 109
C3 18 24 6D 43 67 27 6E 110
BC 19 25 6C 44 68 26 6F 111
BA 1A 26 6B 45 69 25 70 112
B9 1B 27 6A 46 70 23 71 113
B6 1C 28 69 47 71 1F 72 114
B5 1D 29 67 48 72 1E 73 115
B4 1E 30 66 49 73 1D 74 116
B3 1F 31 65 4A 74 1B 75 117
B2 20 32 63 4B 75 18 76 118
B1 21 33 5C 4C 76 17 77 119
AE 22 34 5A 4D 77 10 78 120
AD 23 35 59 4E 78 0F 79 121
AC 24 36 56 4F 79 08 7A 122
AB 25 37 55 50 80 04 7B 123
AA 26 38 54 51 81 02 7C 124
A9 27 39 53 52 82 01 7D 125
A7 28 40 52 53 83
A6 29 41 51 54 84
A5 2A 42 4E 55 85
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 62

11.5.12 Device control codes

The drive inputs a Device Control Code on the DEV_CTRL_CODE lines at power up to determine the link rate on the Fibre Channel ports. Both ports run at the same rate. If the backpanel does not connect to these lines, the drive has 10K ohm pull up resistors that default the device control code to 7 (1.0625 GHz). Table lists the supported codes.
Table 28 Device control code values
2 (PIN 17) 1 (PIN 18) 0 (PIN 39) DEFINITION
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0 Reserved for power failure warning.
1 Reserved for auto negotiation of link rate.
0 Reserved.
1 Reserved.
0 Reserved.
1 4.250 GHz operation on both ports.
0 2.125 GHz operation on both ports.
1 1.0625 GHz operation on both ports.

11.6 SIGNAL CHARACTERISTICS

This section describes the electrical signal characteristics of the drive’s input and output signals. See Table 24 on page 58 for signal type and signal name information.

11.6.1 TTL input characteristics

Table 29 provides the TTL characteristics.
Table 29 TTL characteristics
STATE VOLTAGE CURRENT
Input high 1.9 < VIH < 5.5V IIH = ±500nA max.
Input low -0.5V < V
Output high (-EN Bypass A, B) 2.4 < V
Output low (-EN Bypass A, B) V
OL
Output high (-Parallel ESI) 2.4 < V
VOH > 0.9V
Output low (-Parallel ESI) 0 < V
Output high (all other outputs) 2.4 < V
VOH > 0.9V
Output low (all other outputs) 0 < V
< 0.9V IOL = ±500nA max.
IL
< 5.25V IOH < -3mA
OH
< 0.5V IOL < 3mA
< 0.9 V
OH
< .45V IOL < 2.4mA
OL
< 0.9 V
OH
< .45V IOL < 1.6mA
OL
CC
CC
CC
CC
IOH < -2.4mA I
< -500μA
OH
IOH < -1.6mA I
< -500μA
OH
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 63

11.6.2 LED driver signals

Fault and Active LED signals are located in the FC-SCA connector (J1). See Table 30 for the output characteristics of the LED drive signals.
Table 30 LED drive signal
STATE CURRENT DRIVE AVAILABLE OUTPUT VOLTAGE
LED off, high 0 < IOH < 100μA
LED on, low I
< -30 mA 0 < VOL < 0.8V
OL

11.6.3 FC Differential output

The serial output signal voltage characteristics are provided in Table 31. The outputs are not AC coupled in order to deliver maximum signal without rise and fall time degradation. You must AC couple the receiver to isolate potentially different DC characteristics of the outputs and the receiver.
Table 31 FC Differential output characteristics
DESCRIPTION PARAMETER NOTES
Serial output voltage swing 600 < V
< 1300 mV Centered at 1.32V
out
Figure 16 provides the data output valid eye diagram relative to the bit cell time.
Bit Time
Vout (mv)
XMIT Eye
Figure 16. Transmit eye diagram
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 64

11.6.4 FC Differential input

The serial input signal voltage characteristics are provided in Table 32.
Table 32 FC Differential input characteristics
DESCRIPTION PARAMETER NOTES
Serial input voltage swing 200 < Vin < 1.300 mV AC coupled
17 provides the data valid eye diagram for typical and minimum requirements to recover data at the specified
Figure interface error rate. The inputs are AC coupled on the drive.
941 ps
Vin (mv)
659 ps
376 ps
Figure 17. Receive eye diagram
Table 33 Eye diagram data values
Typical
Minimum
LINK RATE 1 GHZ 2 GHZ 4 GHZ
Bit time 941 ps 470 ps 235 ps
XMIT eye 725 ps min. 315 ps min. 158
RCV eye Typical 659 ps 305 ps 145 ps
Minimum 395 ps 226 ps 113 ps
1. Short Ideal load.
2. End of compliance channel.
/113
21
CHEETAH 15K.7 FC PRODUCT MANUAL, REV. E 65
INDEX
Numerics
12 volt
pins 59
3rd party reserve command 49 5 volt pins 59
A
Abort Sequence (ABTS) 39 abort task set function 40 AC coupling 59 AC power requirements 20 ACA active status 55 ACA active, faulted initiator status 55 Accept (ACC) 39 acoustics 29 active LED Out signal 60 Actual retry count bytes command 46
actuator
assembly design 6
adaptive caching 55 Address Discovery (ADISC) 39 addresses 56 Admin SP 32 AES-128 data encryption 32 AFR 14 air cleanliness 29 air flow 37
illustrated 37
Alternate credit model 41, 44 altitude 26 ambient 26 Annualized Failure Rates (AFR) 15
ANSI documents
fibre channel 5 SCSI 5
arbitrated loop physical address (AL_PA) 37 arbitration 37 asynchronous event notification 55 audible noise 3 auto negotiation of link rate 63
auto write and read reallocation
programmable 7
automatic contingent allegiance 55 average idle current 20, 21 average rotational latency 10
B
Background Media Scan 36 backpanel 57 backplane 61 Band 0 33 BandMasterX 32 basic link service frames 39 Basic_Accept (BA_ACC) 39 Basic_Reject (BA_RJT) 39 BB 41, 44
BB-Credit 41, 44 BMS 36
buffer
data 7 space 12
busy status 55 bypass circuit 15 Byte check command 47
C
cache operation 12 cache segments 12 Caching parameters page (08h) command 46 caching write data 13 Canadian Department of Communications 3
capacity
unformatted 10
capacity, drive, programmable 9 CBC 32 CC 42, 43 CF 41, 44 Change definition command 48 character sync 15 charge pins 59 check condition status 55 Cipher Block Chaining 32 Class 3 parameters 41, 44 class B limit 3 Class valid 41, 44 clear ACA function 40 clear task set function 40 commands supported 46 Common features 41, 44 Company ID 42, 43 Compare command 47 Concurrent sequences 41 condensation 26 condition met/good status 55
connector
illustrated 57 requirements 57
continuous vibration 29 Continuously increasing offset 41, 44 control code values 63 Control mode page (0Ah) command 46 cooling 37 Copy and verify command 47 Copy command 46 CRC 15
error 14
Cryptographic erase 33 CS 41 Current profiles 22 customer service 19
Cheetah 15K.7 FC Product Manual, Rev. E 66
D
DAR 36 Data Bands 33 data bands 32 Data encryption 32 Data Encryption Key 32
data heads
read/write 10
data rate
internal 10
data transfer rate 11 data valid eye 65 Date code page command 46 DC power 57
requirements 20
decrypt 32 default MSID password 32 defect and error management 34 defects 34 Deferred Auto-Reallocation 36 deferred error handling 55 DEK 32 description 6 DEV_CTRL_CODE 63 Device Behavior page command 46 device control code values 63 Device Identification page command 46 device selection IDs 37 devices 37 dimensions 30 Disable page out command 47
Disconnect/reconnect control (page 02h) command
46
disk rotation speed 10 Download microcode and save modes (5) 48 Download microcode mode (4) 48
Download microcode with offsets and save mode (7)
48
Download microcode with offsets mode (6) 48 drive 29
drive capacity
programmable 9
drive characteristics 10 drive ID 37 drive ID/option select headers 37 Drive Locking 33 drive mounting 30, 38 drive orientation 37 drive select 57 driver signals 64 drivers and receivers 7 dual port support 45
E
electrical
description of connector 57
signal characteristics 63 specifications 20
electromagnetic compatibility 3 electromagnetic susceptibility 29 EMI requirements 3
enable bypass
port A 60 port B 60 signal 60 state 15
Enclosure Services interface 57 Enclosure services page command 47 encryption engine 32 encryption key 33
environmental
limits 26 requirements 14
environmental control 29 EraseMaster 32
error
detection mechanisms, FC 15 management 34 rates 14
error correction code
96-bit Reed-Solomon 7
Error recovery page (01h) command 46 errors 34
extended link service
frames 39 reply frames 39
Extended sense command 46 Extent reservation command 49
F
fabric 44 Fabric Address Notification (FAN) 39 Fabric Login (FLOGI) 39 FAN 44 fault LED out signal 59 FC differential input 65
FC-AL
document 5 interface 37, 57 options supported 45 physical interface 56 SCA device connector, illustrated 57 selective reset 55
FCC rules and regulations 3
FCP
for SCSI, document 5 response codes 40 task management functions 40
FC-PH document 5 FDE features 7 features 7
interface 39
Cheetah 15K.7 FC Product Manual, Rev. E 67
Federal Information Processing Standard 31 Fibre Channel documents 5 Fibre Channel Interface Control page (19h) 46 Fibre Channel Interface Manual 2, 3 Fibre Channel Services 39 Field pointer bytes command 46 FIPS 31 firmware 7
corruption 49
Firmware download option command 48 firmware download port 33 Firmware numbers page command 46 flawed sector reallocation 7
FLOGI
received on Port A 43 received on Port B 43
Force unit access command 47 form factor 7 format 37 Format command execution time 11 Format page (03h) command 46 Format unit command 46 FS 41, 42, 44
function
complete, code 00 40 not supported, code 05 40 reject, code 04 40
G
Global Data Band 33 Good status 55 gradient 26 ground shift noise 59 grounding 38
H
hard assigned arbitrated loop physical address
(AL_PA) 37
HDA 38
heads
read/write data 10
heat removal 37 host equipment 38 hot plugging the drive 15 humidity 26 humidity limits 26
I
IC 41 ID and configuration options 7 Idle Read After Write 36 Implemented operating def. page command 46
Information exceptions control page (1Ch) command
47
Initiator control 41 Inquiry command 46
inquiry data 50 installation 37 interface 37
commands supported 46 description 56 error rate 14 errors 14 illustrated 56 physical 56 requirements 39
intermediate/condition met/good status 55 intermediate/good status 55 Intermix 41, 44 internal data rate 10 internal defects/errors 34 internal drive characteristics 10 IRAW 36
J
J1 connector 37 Jumper settings page command 46 jumpers 37
L
latency
average rotational 10, 11
LBdata 48 LED driver signals 64 Link Service Reject (LS_RJT) 39 link services supported 39 Locking SP 32 LockOnReset 33 Lock-unlock-cache command 47 Log select command 48 Log sense command 48 logic power 59 logical block address 12 logical block reallocation scheme 7 logical block size 7, 11 logical segments 12 Logout (LOGO) 39 loop 56, 60
disruption 15 initialization 37
loop position
FC-AL options 45
loop position report
FC-AL options 45
LS_RJT 41, 44 LSI circuitry 8
M
maintenance 14 Makers Secure ID 32 maximum delayed motor start 20, 21 maximum start current 20, 21
Cheetah 15K.7 FC Product Manual, Rev. E 68
mean time between failure (MTBF) 15 media description 8 Media Pre-Scan 36
miscellaneous feature support
Adaptive caching 55 Asynchronous event notification 55 Automatic contingent allegiance 55 Deferred error handling 55 FC-AL selective reset 55 Parameter rounding 55 Queue tagging 55 Reporting actual retry count 55 Segmented caching 55 SMP=1inModeSelect command 55 Synchronized (locked) spindle operation 55 Zero latency read 55
miscellaneous status support
ACA active 55 ACA active, faulted initiator 55 Busy 55 Check condition 55 Condition met/good 55 Good 55 Intermediate/condition met/good 55 Intermediate/good 55 Reservation conflict 55 Task set full 55
miscorrected media data 14
Mode select
(10) command 49 command 46
Mode sense
(10) command 49 command 46 data, table 50, 52
monitoring state 15
motor start
controls 61 option 11
mounting 38
holes 38 orientations 37
mounting configuration 30 mounting configuration dimensions 30 MSID 32 MTBF 15
N
N_Port Login (PLOGI) 39
payload 41 payload values 42
NN 41, 44 Node Name 44 Node name 41
noise
audible 3
noise immunity 21 non-operating 26, 27, 29
temperature 26
non-operating vibration 29
O
office environment 29
old port state
FC-AL options 45
OPEN Full Duplex
FC-AL options 45
OPEN half duplex
FC-AL options 45
Open sequences per exchange 41 operating 26, 27, 29 option configurations 37 option selection 57 options 9, 45 orientation 27 OS 41 out-of-plane distortion 38
P
P_LOGI
received on Port A 42 received on Port B 42
package size 27 package test specification 5 packaged 27 parameter rounding 55 pass-through state 15 password 32 passwords 32 PBC 56, 60 PBdata 48 PCBA 38 peak bits per inch 10 peak operating current 20, 21 peak-to-peak measurements 21
performance characteristics
detailed 10 general 11
performance degradation 27 performance highlights 8 physical damage 29 physical interface 56
description 56
physical specifications 20 PI 42, 43 pin descriptions 58 PN 41, 44 port bypass circuit 15, 56, 60 Port DISCovery 41 Port Discovery (PDISC) 39 port identifier field 42, 43 port login 41
Cheetah 15K.7 FC Product Manual, Rev. E 69
accept 42
Port Name 44 Port name (initiator’s) 41 power 59
dissipation 24 requirements, AC 20 requirements, DC 20 sequencing 22
Power control page (1Ah) command 46 power distribution 3 power failure warning 63 PowerCycle 33 Prefetch command 47 prefetch/multi-segmented cache control 12 preventive maintenance 14
private loop
FC-AL options 45
Proc Assc 41 Process Accept (ACC) 43 Process Login (PRLI) 39, 42 Process Login Accept (ACC) payload 43 process login payload data 42 Process Logout (PRLO) 39 programmable drive capacity 9 protection of data at rest 32
public loop
FC-AL options 45
pull down resistor 60
recommended mounting 28 Recoverable Errors 14 recovered media data 14
reference
documents 5
Regenerate command 49 Register FC-4 Types (RFT_ID) 39 Relative address command 47 relative humidity 26 Release command 46 Released (10) command 49 reliability 8
specifications 14
reliability and service 15 repair and return information 19 reporting actual retry count 55 Request sense command 46 reservation conflict status 55 Reserve command 46 Reserved (10) command 49 resonance 27 return information 19 Rezero unit command 46
Rigid disk drive geometry page
command 46
RNG 32 rotation speed 10 running disparity 15
Q
queue tagging 55
R
radio interference regulations 3 Random number generator 32 Random relative offset 41, 44 RCD bit 12 Read buffer command 48 Read capacity command 47 Read combined header and data mode (0) 48 Read command 46 Read data mode (2) 48 Read defect data command 47 Read descriptor mode (3) 48 read error rates 14, 34 Read extended command 47 Read Link Status (RLS) 39 Read long command 48 read/write data heads 10 Reassign blocks command 46 Receive buffer field size 41, 44 receive buffer field size 42 Receive diagnostic results command 47
receive eye
diagram 65
receivers 59
S
safety 3 SCA part numbers 57
SCSI interface
commands supported 46
Seagate Technology Support Services 1
Search data
equal command 47 high command 47 low command 47
Secure ID 32 security partitions 32 Security Protocol In 32 Security Protocol Out 32 Seek command 46
seek error
defined 14 rate 14
Seek extended command 47 seek performance characteristics 10
seek time
average typical 10 full stroke typical 10 single track typical 10
segmented caching 55 SEL ID 37
lines 61
Cheetah 15K.7 FC Product Manual, Rev. E 70
standard feature 7
Self-Encrypting Drive (SED) Users Guide 2 self-encrypting drives 32
Self-Monitoring Analysis and Reporting Technology
8, 15
Send diagnostics page command 47 Sequential delivery 41, 44 Service Options 44 Service options 41 Set limits command 47 shielding 3 shipping 19 shipping container 26 shock 27
and vibration 27
shock mount 38 SID 32
signal
characteristics 63 LED driver 64
single-unit shipping pack kit 9 SMART 8, 15 SMP = 1 in Mode Select command 55 SO 41, 44 spindle brake 7 Stacked connection req. 41, 44 standards 3 Start unit/stop unit command 47 start/stop time 11 Supported diagnostics pages command 47
surface stiffness
allowable for non-flat surface 38
switches 37 Synchronize cache command 47
synchronized spindle
operation 55
system chassis 38
T
target reset function 40 task management functions 40
Abort task set 40 Clear ACA 40 Clear task set 40 Target reset 40 terminate task 40
task management response codes 40
Function complete 00 40 Function not supported 05 40 Function reject 04 40
task set full status 55 TCG 32 TCG Storage Architecture Core Specification 3 temperature 26, 37
limits 26 non-operating 26
regulation 3
See also cooling
terminate task function 40 terminators 37 Test unit ready command 46 Third-party Process Logout (TRPLO) 39 tracks per inch 10 Translate page command 47 transmit eye diagram 64 transmitters 59 transporting the drive 19 Trusted Computing Group 5, 6, 32 TTL input characteristics 63
U
UI 42, 43 unformatted 8 unique identifier 42, 43 Unit attention page (00h) command 46 Unit serial number page command 46 Unrecoverable Errors 14 unrecovered media data 14
V
Valid version level 41, 44 Verify command 47, 49 Verify error recovery page (07h) command 46 vibration 27, 29 Vital product data page command 46
W
warranty 19 word sync 15 Write and verify command 47 Write buffer command 47 Write combined header and data mode (0) 48 Write command 46 Write data mode (2) 48 Write extended command 47 Write long command 48 Write same command 48, 49
X
XD read 48 XD write 48 XD write extended command 49 XID reassign 41 XP write 48
Z
zero latency read 55 zone bit recording (ZBR) 7
Cheetah 15K.7 FC Product Manual, Rev. E 71
Seagate Technology LLC
AMERICAS Seagate Technology LLC 10200 South De Anza Boulevard, Cupertino, California 95014, United States, 408-658-1000 ASIA/PACIFIC Seagate Singapore International Headquarters Pte. Ltd. 7000 Ang Mo Kio Avenue 5, Singapore 569877, 65-6485-3888 EUROPE, MIDDLE EAST AND AFRICA Seagate Technology SAS 16-18 rue du Dôme, 92100 Boulogne-Billancourt, France, 33 1-4186 10 00