Cheetah 15K.4 Installation Guide
ST3146854LW/LC, ST373454LW/LC and ST336754LW/LC
SCSI interface disc drives
Publication Number: 100220463, Rev. B, February 2004
Handling precautions/Electrostatic discharge protection
• Disc drives are fragile. Do not drop or jar the drive. Handle the drive only
by the edges or frame.
• Drive electronics are extremely sensitive to static electricity. Keep the
drive in its antistatic container until you are ready to install it. Wear a wrist
strap and cable connected to ground. Discharge static from all items near
or that will contact the drive. Never use an ohmmeter on any circuit
boards.
• Turn off the power to the host system during installation.
• Always use forced-air ventilation when operating the drive.
• Use caution when troubleshooting a unit that has voltages present.
• Do not disassemble the drive; doing so voids the warranty.
• Return the entire drive for depot service if any part is defective.
• Do not apply pressure or attach labels to circuit board or drive top.
Electromagnetic compliance
See Safety and Regulatory Agency Specifications, part number 75789512.
Drive characteristics
ST3146854 ST373454 ST336754
LW/LC LW/LC LW/LC
Formatted capacity 146.8 Gbytes 73.4 Gbytes 36.7 Gbytes
Total # of data blocks 143,374,744 71,687,372 35,843,686
Cylinders (user accessible) 51,461 51,461 51,461
Heads (user accessible) 8 4 2
Disc rotation +/–5% 15,000 RPM 15,000 RPM 15,000 RPM
What you need
• Screwdriver and four 6-32 UNC drive mounting screws
• Forced-air ventilation to provide adequate drive cooling
• An unused drive power connector (not applicable to LC models)
To operate at LVD transfer rates, you may also need an LVD-capable SCSI
host adapter, LVD I/O cable and active negation external terminator.
Multimode interface
This drive can operate in single-ended (SE) or low voltage differential (LVD)
mode. This multimode capability provides backwards compatibility so you
can use it with or without an LVD-capable host adapter. The primary benefits of LVD technology include faster transfer rates, increased allowable
cable lengths, and improved device connectivity.
You can configure the drive to detect between SE and LVD modes automatically or force it to operate in SE mode only. To configure this option, see
Figure 2.
Note. To operate at Ultra2 rates or faster in LVD mode, all devices on the
same bus (cable) must be running in LVD mode. If you add any SE
device to the bus, all devices on that bus operate in SE mode.
Note. Some LVD host adapters provide an LVD connector and an SE con-
nector on the same host adapter to allow you to run SE and LVD
drives concurrently at their maximum capabilities. Check your SCSI
host adapter documentation. See Figure 3.
Caution. Do not mix LVD drives on the same bus with high voltage differ-
ential (HVD) devices–drive damage may occur.
(11177330h) (88BB998h) (445DCCCh)
Installation instructions
1. Set the SCSI ID
Determine which SCSI IDs are already being used in t he system and then
assign this disc drive a SCSI ID that isn’t already being used. Use the J6
connector located on the front of the drive to set the SCSI ID (see Figure 1).
• Most Cheetah
this is the only SCSI drive in your system and there are no other SCSI
devices on the daisy chain, you can leave this drive’s SCSI ID set to 0
and proceed to the next step.
• The host system’s SCSI controller usually uses SCSI ID 7.
• If you have an LC model drive, t he host norm ally s e ts the ID over the I/O
interface, so you don’t need to worry about this step.
• If you have an LW model drive, some systems provide a cable designed
to connect to the J5 jumper block on the drive to remotely set the ID. You
can connect this cable to J5 and use the host-provided remote switch to
set the SCSI ID. This J5 connector is not present on LC model drives.
Drive
Front
Jumper Plug
(enlarged to
show detail)
SCSI ID = 0 (default)
SCSI ID = 1
SCSI ID = 2
SCSI ID = 3
SCSI ID = 4
SCSI ID = 5
SCSI ID = 6
SCSI ID = 7
SCSI ID = 8
SCSI ID = 9
SCSI ID = 10
SCSI ID = 11
SCSI ID = 12
SCSI ID = 13
SCSI ID = 14
SCSI ID = 15
Figure 1. Setting the SCSI ID
2. Configure termination
If you are installing the drive in a system that has other SCSI devices
installed, terminate only the end devices on the SCSI bus (cable). This drive
does not have internal terminators or any other way of adding internal termination on the drive. You must provide external termination when termination
is required. This is normally done by adding an inline terminator on the end
of the cable. See Figure 3 for an illustration showing a system configuration
that uses an external terminator.
• Use active (ANSI SCSI-2 Alternative 2) single-ended terminators when
terminating a bus operating in single-ended mode.
• Use SPI-2-compliant active low voltage differential terminators when terminating a SCSI Ultra2 bus operating in LVD mode.
• The host adapter is normally on the end of the bus and internally terminated. You can configure your bus with another device on the end if you
remove termination from the host adapter.
3. Configure terminat or power (LW model only )
Term inator s have to get power from some source. The default configuration
results in the drive not supplying termination power to the bus. You should
normally leave this drive set at this default unless your host system requires
the drive to supply termination power to the bus. To configure this drive to
supply termination power to the bus, place a jumper on J2 pins 1 and 2 as
shown in Figure 2.
®
15K.4 drives are factory set with the SCSI ID set at 0. If
Drive HD
J5
J1
Pin 1
DC Power
4P 3P 2P 1P
Rear
J6
Reserved
68 Pin
SCSI I/O
Connector
Pin 1
R
L
E
E
A2A1A0A
3
S
D
SCSI ID = 0
SCSI ID = 1
SCSI ID = 2
SCSI ID = 3
SCSI ID = 4
SCSI ID = 5
SCSI ID = 6
SCSI ID = 7
SCSI ID = 8
SCSI ID = 9
SCSI ID = 10
SCSI ID = 11
SCSI ID = 12
SCSI ID = 13
SCSI ID = 14
SCSI ID = 15
J1
not used
Pin 1
+5V
Ground
A
3A2A1
A
0
(default)
Drive with
HDA up, PCB
down, viewed
from front
Reserved
Reserved
Remote
LED
Shipped with cover installed.
Do not remove.
Do not install jumpers
on these four positions.
Drive Front
DC Power
Connector
SCSI I/O
Connector
HDA
L
E
D
11
12
Reserved Positions
Delay Motor Start option (valid
only if the Enable Motor Start
jumper is not connected)
Pin 1
J6
R
E
A2A3A1A
0
S
J6 Jumper
J6
Pin 1
J2
Pin 1
Disable the Delay Motor Start option.
Motor start delay equal to the
SCSI ID multiplied by 12 seconds.
Motor Start option
Disable motor start (default). The
drive starts according to the Delay
Motor Start option.
Enable motor start. The drive waits for
the Start Unit command from the host
before starting the spindle motor.
CATH
Write Protect option
Write protect = Off (enables writing).
Write protect = On (disables writing).
Parity Check option
Enable parity check of SCSI bus.
Disable parity check.
Single-ended I/O
A jumper here forces single-ended
I/O operation.
No jumper allows host to select either
J2 Jumper
single-ended or LVD operation.
Terminator Power
Term. Power to SCSI Bus
Host adapter or other device provides
term. power to external terminator.
J2
Figure 2. Option sel ect jumper s (LW model only)
4. Connect the drive activity LED (optional)
Connect the Drive Activity LED cable to J6 pins 11 and 12 (see Figure 2), or
connect a drive ID and Drive Activity LED c able to J5, depending on host
system requirements.
5. Check the other available jumper settings
Select other options on J2 as illustrated in Figure 2. Do not change these
unless instructed to do so by the host system documentation.
6. Mount the drive in the host system and connect cables
Note. LC drives are designed to be attached to a carrier or tray and
inserted into the host system without I/O or power cables.
a. Mount LW model drives to the host system’s chassis using four 6-32
UNC screws. Two mounting holes are in each side of the drive and
there are four mounting holes in the bottom of the drive. Do not overtighten or force the screws. You can mount the drive in any orientation.
b. Connect the SCSI I/O cable into the drive’s SCSI connector. Take care
not to stretch or crimp this cable, and do not block the system’s cooling
air flow with the cable.
Note. For Ultra2 and faster operation, special twisted pair LVD cables are
required.
c. Connect the DC power cable to the drive. See Figure 3.
Ultra160 or Ultra2 LVD bus segment
Pin 1
(check your
adapter for
Pin 1 location)
SCSI LVD/SE
CSI SE
Twisted Pair
LVD Cable
Host
Adapter
PCB
Ultra SCSI SE bus segment
Figure 3. Cable connections and external termination
7. Format the drive
The drive has been low level formatted at the factory. You do not need to
perform another low level format on this drive unless you decide to perform
certain diagnostics through the host adapter. If you do decide to perform a
low level format, do not abort the format as this is likely t o make the drive
inoperable. A low level format, with verify turned on, will typically take 30
Pin 1
(defaul
(defaul
(defaul
(defaul
(defaul
(defaul
SPI-2 compliant
active LVD
external terminato
on the end of
the cable
minutes for ST336754 models, 60 minutes for ST373454 models, and 90
minutes for ST3146854 models.
Protect against power failure or other power interruptions during the format.
a. Turn on DC power to the host system.
b. Boot the system from a system floppy, CD, or from a previously
installed hard disc drive if there is one.
c. Format the drive.
Caution. Formatting a drive erases all user data. Be sure that you under-
stand this principle before formatting any hard disc drive. It is not
necessary to format a drive that previously has been used to
store data, unless your intention is to erase all user data.
®
Seagate
is not responsible for lost user data.
Cheetah 15K.4 disc drives are designed to operate with a variety of operating systems. Please refer to your system or SCSI controller manual for
information about formatting and setting up the drive. Some quick desktop
system notes are provided below.
TM
• Microsoft
. Set the drive type in CMOS to “Zero,” “None,” or “No hard
drive installed.” Use FDISK.EXE and FORMAT.EXE. Systems using Windows 98 or later can create one single partition (drive letter) on the drive.
TM
• Macintosh
. Use Apple’s Disk Utility (typically found in the Applications/
Utilities folder on most Mac OS systems) to initialize and partition the
drive for an Apple file system.
Troubleshooting
• Drive does not spin up. Check cables and all jumper settings. Make
sure cable pin 1 (edge stripe) matches PCB pin 1.
• Drive spins , but no LED on/off activity. Check SCS I ID setting. Set th e
ID so that each device on the SCSI chain has its own unique ID. See also
the next item below. Host I/O controller is usually ID7.
• Computer does not seem to recognize the d rive. Verify that the drive
is enabled by the SCSI host adapter setup utility.
• FDISK does not detect the drive. Run the FDISK program locate d on
your Windows startup diskette. Type fdisk/status to verify that your hard
drive is present.
Seagate support services
For online information about Seagate products, visit www.seagate.com or
e-mail your disc questions to DiscSupport@Seagate.com.
If you need help installing your drive, consult your dealer first. If you need
additional help, call a Seagate technical support specialist. Before calling,
note your system configuration and drive model number (ST3146854LW,
ST3146854LC, ST373454LW, ST373454LC, ST336754LW or
ST336754LC.)
Africa +31-20-316-7222 New Zealand 0800-443988
Australia 1800-14-7201 Norway 800-113 91
Austria 0 800-20 12 90 Poland 00 800-311 12 38
Belgium 0 800-74 876 Spain 900-98 31 24
Denmark 80 88 12 66 S weden 0 207 90 073
France 0 800-90 90 52 Switzerland 0 800-83 84 11
Germany 0 800-182 6831 Singapore 800-1101-150
Hong Kong 800-90-0474 Taiwan +886-2-2514-2237
India 1-600-33-1104 Thailand 001-800-11-0032165
Indonesia 001-803-1-003-2165 Turkey 00 800-31 92 91 40
Ireland 1 800-55 21 22 United Kingdom 0 800-783 5177
Italy 800-790695 USA/Canada/ 1-800 SEAGATE or
Japan 0034 800 400 554 Latin America +1-405-936-1234
Malaysia 1-800-80-2335 Other European
Middle East +31-20-316-7222 countries +31-20-316-7222
Netherlands 0 800-732-4283
Warranty. Contact your place of purchase or our web site (above).
Return Mercha ndise Au thor izatio n (R MA). Before returning the drive, ver ify that it
is defective. Seagate Worldwide customer service centers are the only facilities authorized to service Seagate drives. Contact nearest center for return procedures and trade
regulations.
Shipping the drive
Caution. Back up the data befo re shipping. Seaga te assumes no respo nsibility for
data lost during shippin g or service. Sh ipping drive in an unapprove d container void s
the warranty. Pack the drive w ith original box and packing materials. Use no other
materials. This prevents electrical and physical damage in transit.
© 2004 Seagate Technology LLC All rights reserved
Publication number: 100220463, Rev. B, February 2004, Printed in U.S.A.
Seagate and Seagate Technology are registered trademarks of Seagate Technology
LLC. Cheetah and the Wave logo are reg ister ed tr ade ma rks or trad ema rks of Sea ga te
Technology LLC. Other product names ar e registered trademarks or trademarks of
their owners. Seagate reserves the right to change, without notice, product offerings or
specifications.