ERC Series
Air Cooled Remote Condensers
ERC Series
ERC402
ERC311
Features
Operate in wide outdoor temperature range from -20ºF to 120ºF.
Single or double circuit for single or double unit installations.
Heavy gauge galvanized steel for corrosion resistance.
Thermally protected fan motors.
PVC coated steel fan guards.
Direct drive fan blades.
Standard Aero-Quip fittings.
Options
Choice of pre-charged, insulated,
refrigerant line sets with easy to install
quick-connect couplings. Available in
10 ft., 25 ft., 40 ft. and 75 ft. lines
Scotsman I ce Systems
775 Corporate Woods Parkway
Vernon Hills, IL 60061
1-800-SCOTSMAN
Fax: 847-913-9 844
E-mail: cu stomer.service@scotsman-ice.com
Warranty
• 3 years parts and labor on all components.
Warranty vali d in North, South & Central A merica.
Contact fa ctory for warra nty in other reg ions.
www.scotsman-ice.com
The smart choice in ice.™
®
ERC Series
ERC Horizontal Coil Series
Model Num ber A
Overall Leng th
B
Mounting
Hole Spaci ng
Voltage
Circuit
Wires
Min. Circu it
Ampacity
Contains
Headmaster?
ERC402-32A 44.125” 16.65” 208-230 / 60 / 1 2 2.6 No
Note: This unit has a galvanized finish, is 23.8125” wide and has adjustable height legs. Heights are 12”, 18” and 24”. Total height with legs is
29.25” or 35.25” or 41.25”. This unit is designed to be powered by the ice machine it is connected to. The minimum circuit ampacity and maximum fuse size of the ice machine includes the requirements of the remote condenser.
Shipping
Weight
lb / kg
140 / 64
Shiping Car ton
29 x 55 x 22
(73.6 x 139.7 x 55.9 cm)
ERC Vertical Coil Series
Model Num ber C
ERC111-1A
ERC311-32A
ERC611-32A
Note: All units have a galvanized finish, are 29.5” wide and 38.5” high with legs. These units are designed to be powered by the ice machine they
are connec ted to. The minimum circuit ampacity and maximum fuse size of the ice machine includes the requirements of the remote condenser.
All but the ERC611 have 1/2” discharge and 3/8” liquid line connections. The ERC611 has a 5/8” discharge line connection.
Options: KERCF air filter kit fits ERC111-1A and ERC311-32A
Overall Leng th
29.125”
29.125”
37.75”
D
Mounting
Hole Spaci ng
23.54”
23.54”
32.16
Voltage
115 / 60 / 1
208-230 / 60 / 1
208-230 / 60 / 1
Circuit
Wires
1
1
1
Min. Circu it
Ampacity
2.7
2.6
1.9
Contains
Headmaster?
Yes
Yes
Yes
Shipping
Weight
lb / kg
95 / 43
130 / 59
140 / 64
Shiping Car ton
32 x 31 x 34
(81.3 x 78.7 x 86.4 cm)
32 x 34 x 34
(81.3 x 78.7 x 86.4 cm)
31 x 33 x 39
(81.3 x 78.7 x 99.1 cm)
Operating Requirements
Minimum Maximum
Air Temperatures
Water Temperatures
Remote Cond. Temps
Water Pressures
Electrica l Voltage
Specificatio ns and desig n are subject to change w ithout notice.
Scotsman I ce Systems
775 Corporate Woods Parkway
Vernon Hills, IL 60061
50°F (10°C) 100°F (38°C)
40°F (4.4°C) 100°F (38°C)
-20°F (-29°C) 120°F (49°C)
20 PSIG (1.4 bar) 80 PSIG (5.5 bar)
-10% +10%
1-800-SCOTSMAN
Fax: 847-913-9 844
E-mail: cu stomer.service@scotsman-ice.com
www.scotsman-ice.com
W x D x H
W x D x H
© 2009 Sco tsman Ice Systems. SIS-SS-ERC 8-09