ERC and PR Series Remote Condensers
Air Cooled Remote Condensers
Features
Operate in wide outdoor temperature range from -20ºF to 120ºF.
Single or double circuit for single or double unit installations.
Heavy gauge galvanized steel for corrosion resistance.
Thermally protected fan motors.
PVC coated steel fan guards.
Direct drive fan blades.
Standard Aero-Quip fittings.
Maximizes ice production by dissipating heat away from ice machine.
Minimizes air conditioning load.
ERC and PR Remote Condensers
PRC241
Line Sets
Choice of pre-charged, insulated, refrigerant line
sets with easy to install quick-connect couplings.
Available in 10ft, 25ft, 40ft and 75ft lines. Please
consult ice machine users manual for installation
guidelines.
Certification Warranty
• 3 years parts and labor on all components.
8
• Warranty valid in North, South & Central
America for commercial installations.
• Contact factor y for warranty in other regions.
101 Corporate Woods Parkway, Vernon Hills, IL 60061
1-800-SCOTSMAN Fax: 847-913-9844 customer.relations@scotsman-ice.comwww.scotsman-ice.com
CONDENSER FINS
38.47”
(97.7cm.)
.562 DIA.
MOUNTING
HOLES (4)
2.84”
(7.2cm.)
SHIPPING WEIGHT: 135 LBS.
B
C
D
E
SHIPPING WEIGHT: 135 LBS.
PR2C240-32A
SHIPPING WEIGHT: 135 LBS.
DATE DRAWN:
DRAWN BY:
APPROVAL:
MATERIAL
FINISH
UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN INCHES
DO NOT SCALE THIS PRINT
DECIMALS
ANGLES
PART NAME
PROPRIETARY INFORMATION ・This drawing,
exclusive property of Scotsman Ice Systems and
shall be returned to it upon request. This drawing
is not to be reproduced in whole or in part or
disclosed to anyone else without the express
written consent of Scotsman Ice Systems.
COPYRIGHT 2010 SCOTSMAN ICE SYSTEMS
775 CORPORATE WOODS PARKWAY
ABC DRAWING, PR2C240-32A
CSS
.
10/21/10
1
4
7
8
6
5
3
2
.
NOTICE
NO
SYM DESCRIPTION OF CHANGE BY DATE
0 FOR REVIEW ONLY CSS
10/21/10
. RELEASE FOR PRODUCTION JMA
09/02/11
37.75
958.85
38.91
988.36
750.06
29.53
33.38”
MOUNTING
HOLES Ø .562
(847.95cm.)
34.49”
(876.15cm.)
2.77”
(70.31cm.)
(805.66cm)
31.72”
PRC241-32A
4
7
8
6
5
29.53
750.06
37.75
958.85
38.91
988.36
MOUNTING
HOLES
(847.95cm.)
34.65”
(880.11cm.)
2.77”
(70.31cm.)
31.88”
(809.63cm.)
ERC and PR Series Remote Condensers
Air Cooled Remote Condensers
PR2C240ERC Series PRC241
34.65”
(880.11cm.)
Ø .88
ELECTRICAL
INLET
23.57”
20.07”
(509.68cm.)
.87”
(22.10cm.)
31.88”
(809.63cm.)
2.77”
(70.31cm.)
(250.95cm.)
(371.09cm.)
9.88”
14.61”
(847.95cm.)
MOUNTING
HOLES Ø .562
27.57”
(700.28cm.)
MOUNTING
33.38”
FLOW
.50”
(1.27cm.)
(82.1cm.)
.562 DIA.
MOUNTING
HOLES (4)
88 DIA.
ELECTRICAL
INLET
DISCHARGE
LINE MALE
QUICK CONNECT
32.32”
28.07”
(71.2cm.)
24.71”
(62.7cm.)
7.60”
(19.3cm.)
CONDENSER FINS
29.50”
(74.9cm.)
11.50”
(29.2cm.)
14.56”
(36.9cm.)
27.56”
(70.0cm.)
29.19”
(74.1cm.)
38.47”
(97.7cm.)
2.84”
(7.2cm.)
(.95cm.)
DISCHARGE
LINE MALE
QUICK CONNECT
AIR FLOW
.65”
(1.7cm.)
.38”
ELECTRICAL
DISCHARGE LINE
1/2 IN. MALE CPLG.
LIQUID LINE
3/8 IN. MALE CPLG.
(805.66cm)
34.49”
(876.15cm.)
(70.31cm.)
Ø .88
INLET
22.91”
(581.91cm.)
21.53”
(546.86cm.)
.87”
(22.10cm.)
31.72”
2.77”
9.89”
(251.21cm.)
11.85”
(300.99cm.)
(700.28cm.)
MOUNTING
33.38”
(847.95cm.)
MOUNTING
HOLES Ø .562
(217.42cm.)
(252.22cm.)
27.57”
8.56”
9.93”
DISCHARGE LINE
1/2 IN. MALE CPLG.
LIQUID LINE
3/8 IN. MALE CPLG.
24.78”
(629.41cm.)
AIR
FLOW
22.86”
(580.64cm.)
(598.58cm.)
Operating Requirements: Electrical Voltage Min. -10% Max. +10%
Specifications
Model C
Overall LengthNumber
ERC111-1
ERC311-32
ERC611-32
ERC SeriesPR Series
Note: All units have a galvanized nish, are 29.5” wide and 38.5” high with legs. These units are designed to be powered by the ice machine they are connected to. The minimum
circuit ampacity and maximum fuse size of the ice machine includes the requirements of the remote condenser. All but the ERC611 have 1/2” discharge and 3/8” liquid line
connections. The ERC611 has a 5/8” discharge line connection.
29.125”
29.125”
37.75”
Mounting
Hole Spacing
23.54”
23.54”
32.16”
Basic Electrical
Volts/Hz/Phase
115/60/1
208-230/60/1
208-230/60/1
Min. Circuit
Ampacity
1
1
1
2.7
1.25
1.9
Contains
Headmaster?
Yes
Yes
Yes
D
Shipping
Weight
lb/kg
95/43
130/59
140/64
(81.3 x 78.7 x 86.4 cm)
(81.3 x 86.4 x 86.4 cm)
(78.7 x 83.8 x 99.1 cm)
LIQUID LINE
1/2 IN. MALE CPLG.
DISCHARGE LINE
5/8 IN. MALE CPLG.
AIR
Shipping Carton
W x D x HCircuits
32” x 31” x 34”
32” x 34” x 34”
31” x 33” x 39”
Specifications
ERC and PR Remote Condensers
Model
PR2C240-32
PRC241-32
Note: This unit has a galvanized nish, is 23.8125” wide and has adjustable height legs. Heights are 12”, 18” and 24”. Total height with legs is 29.25” or 35.25” or 41.25”. This unit is
designed to be powered by the ice machine it is connected to. The minimum circuit ampacity and maximum fuse size of the ice machine includes the requirements of the remote
condenser.
Overall LengthNumber
38.91”
38.91”
Accessories
Hole Spacing
RTE10 - 10ft (3.0 m) precharged R-404A tubing
RTE25 - 25ft (7.6 m) precharged R-404A tubing
RTE40 - 40ft (12.2 m) precharged R-404A tubing
RTE75 - 75ft (22.9 m) precharged R-404A tubing
KTE4 - Tube end kit - contains 4 quick connect fittings for any RTE line set
1-800-SCOTSMAN Fax: 847-913-9844 customer.relations@scotsman-ice.comwww.scotsman-ice.com
Mounting
Basic Electrical
Volts/Hz/Phase
208-230/60/1
208-230/60/1
33.38”
33.38”
101 Corporate Woods Parkway, Vernon Hills, IL 60061
Min. Circuit
Ampacity
2
1
1.9
1.9
Contains
Headmaster?
No
Yes
Shipping
Weight
lb/kg
135/61
135/61
Shipping Carton
W x D x HCircuits
32” x 40.5” x 27.5”
(81.3 x 102.9 x 69.9 cm)
RTEL10 - 10ft (3m) precharged R-404A tubing. Use with C2648 remote cooled units.
RTEL25 - 25ft (7.6m) precharged R-404A tubing. Use with C2648 remote cooled units.
RTEL40 - 40ft (12.2m) precharged R-404A tubing. Use with C2648 remote cooled units.
RTEL75 - 75ft (22.9m) precharged R-404A tubing. Use with C2648 remote cooled units.
KTEL4 - Tube end kit - contains 4 quick connect fittings for RTEL tubing.
KERCF - Air filter for ERC111 or ERC311.
SIS-SS-ERCPR 01-17© 2017 Scotsman Ice Systems.