Schumacher PST-200 User Manual

OWNER’S MANUAL
Model: PST-200
100 Amp Digital Battery Load Tester/Charging System Analyzer For 12 Volt Batteries
ELECTRIC CORPORATION
MT. PROSPECT, IL 60056
Customer Returns P.O. Box 280 1025 E. Thompson Avenue Hoopeston, IL 60942-0280
Questions? Call Customer Service
1-800-621-5485
00-99-000438/1004
INSTRUCTIONS FOR USE
WARNING: Handling the cord on this product or cords associated with
accessories sold with this product, will expose you to lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive
Wash hands after handling.
harm.
WARNING - RISK OF EXPLOSIVE GASES
1. Working in the vicinity of a lead acid battery is dangerous. Batteries generate explosive gases during normal battery operation. For this reason, it is of utmost importance that each time before using your tester, you read these instructions carefully and follow instructions by battery manufacturer as well.
2. To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in the vicinity of the battery. Observe precautionary markings on these items.
12 Volt BATTERY ANALYSIS - Press “START TEST” & wait for 10 seconds. Once automatic test cycle is completed, your test results will be:
1. GREEN LIGHT = Determine state of charge by checking specific gravity (use hydrometer). If gravity is less than full charge, check for possible charging system trouble or electrical drain. Recharge battery to fully charged level.
2. GREEN + YELLOW LIGHT = OK BUT WEAK): Review the load test result with the comparison chart on the tester cover to see if this battery is “OK” or not. If it is “OK”, go up to 1ST “OK” state. If it is not, go down to 3rd “WEAK” state.
3. YELLOW LIGHT = either: (1) defective or (2) partially discharged. To determine which, check specific gravity. If gravity is over 1.225, battery is considered defective. If gravity is under 1.225, recharge battery and re-test. If cell-to-cell gravity varies more than 0.025 (25 points), cell trouble may exist. If charging does not bring gravity to fully charged level, the battery is either sulfated or has lost active material.
4. RED LIGHT =
OK): Battery capacity is good. May or may not be fully charged.
WEAK): Battery capacity is unsatisfactory. Battery may be
BAD): Battery may be defective (e.g. a bad cell).
NOTE: If pre-test battery voltage is below 12.3V, tester will not allow and
should not perform the load test. Please fully charge battery and retest.
TEMPERATURE COMPENSATION 1 STEP = 50 cranking amps.
BATTERY TEMPERATURE +20°F 0°F -20°F
DECREASE BATTERY RATING BY: 1 STEP 2 STEP 3 STEP