SE7000 Quick Reference Guide
SE7200 & SE7300 Controllers
Low Voltage (24VAC) Zone and Fan Coil Unit Applications
1 2 3 4 5 6
Building
Function
Applications / Features
•
2 or 4 pipe
•
Hot/chill water valves
•
Automatic changeover
•
Auxiliary contact output
Zone
• Binary Inputs
•
2 or 4 pipe
•
Up to 3 speed fan control
•
Hot/chill water valves
•
Automatic changeover
•
Auxiliary contact output
•
Binary inputs
Commercial
•
ECM fan control
•
2 pipe
•
Hot/chill water valve
•
Automatic changeover
•
Auxiliary contact output
• Binary inputs
Humidity
Control
Outputs /
Inputs
Floating
or On-Off,
1H/1C,
Reheat
Analog,
1H /1C,
Reheat
Floating
or On-Off,
1H/1C,
Reheat
Analog,
1H/1C,
Reheat
Floating
or On-Off,
1H/1C,
Reheat
Analog,
1H/1C,
Reheat
Analog,
1H/1C,
Reheat
Motion
Sensor
SE7200C5545(X)
SE7200C5045(X)
SE7200F5545(X)
SE7200F5045(X)
SE7350C5545(X)
SE7350C5045(X)
SE7350F5545(X)
SE7350F5045(X)
SE7300C5545(X)
SE7300C5045(X)
SE7300F5545(X)
SE7300F5045(X)
SE7300F5545(X)-ECM
SE7300F5045(X)-ECM
Network Ready
Controller
Low Voltage (24VAC) Rooftop and Heat-Pump Applications
1
Building
Function
•
Roof top
•
Heat pump
•
Single fan speed
•
Frost protection
•
Auxiliary contact output
Commercial
•
Digital inputs
•
Discharge air sensor
SE7600 Controllers
2
Applications / Features Scheduling
*
*
*
*
3 4 5 6
Outputs /
Inputs
On-Off,
1H/1C
On-Off,
2H/2C
Heat pump,
1, 2 compressors
Rev. valve
Aux. heat
On-Off, 2H/2C,
Humidity
On-Off,
2H/2C,
Economizer
WaterSource HP
1, 2 compressors
Rev. valve
Humidity
On-Off, 2H/2C,
Analog heat,
2
CO
control
Economizer
On-Off, 2C,
Analog heat
On-Off,
1H/1C
Motion
Sensor
Network Ready
Controller
SE7600A5545(X)
SE7600A5045(X)
SE7600B5545(X)
SE7600B5045(X)
SE7600H5545(X)
SE7600H5045(X)
SE7607B5545(X)
SE7607B5045(X)
SE7605B5545(X)
SE7605B5045(X)
SE7600W5545(X)
SE7600W5045(X)
SE7606E5545(X)
SE7606E5045(X)
SE7600F5545(X)
SE7600F5045(X)
SE7652A5545(X)
SE7652A5045(X)
SER7300 Controllers & SC3000 Relay Pack
Line Voltage Fan Coil Unit Applications
1 2 3 4 1 2 3
Building
Function
Commercial
Applications /
Features
•
2 or 4 pipe
•
Up to 3 speed
fan control
•
2 Binary inputs
(SER7300)
•
Auto changeover
4 pipe or 2 pipe
+ reheat
•
Sames as above
but 2 pipe only or
2 pipe + reheat
•
Up to 3 speed
fan control
•
2 or 4 pipe
•
Up to 3 speed
fan control
•
2 Binary inputs
(SER7300)
•
Auto changeover
4 pipe or 2 pipe
+ reheat
*
*
*
Outputs /
Inputs
On-Off, 1H/1C
On-Off ,1H/1C,
4 remote inputs,
On-Off , 1H/1C,
4 remote inputs,
Occ output
On-Off , 1H/1C,
Pulsed reheat
On-Off, 1H/1C,
Pulsed reheat,
4 remote inputs
On-Off, 1H/1C
On-Off, 1H/1C,
4 remote inputs,
On-Off, 1H/1C,
4 remote inputs,
Occ output
Relay Pack
SC3500E5045
SC3504E5045
SC3514E5045
SC3400E5045 SER7300A5545(X)
SC3404E5045
SC3300E5045
SC3500E5045
SC3504E5045
SC3514E5045
Humidity
Control
Motion
Sensor
SER7350A5545(X)
SER7350A5045(X)
SER7300A5045(X)
SER7355A5545(X)
SER7355A5045(X)
Network Ready
Controller
•
2 or 4 pipe
•
Up to 3 speed fan control
•
Hot/chill water valves
•
Automatic changeover
•
Auxiliary contact output
• Binary inputs
Hospitality / Lodging
•
ECM fan control
•
2 pipe
•
Hot/chill water valve
•
Automatic changeover
•
Auxiliary contact output
• Binary inputs
Floating
or On-Off,
1H/1C,
Reheat
Analog,
1H/1C,
Reheat
Floating
or On-Off,
1H/1C,
Reheat
Analog,
1H/1C,
Reheat
Analog,
1H/1C,
Reheat
SE7355C5545(X)
SE7355C5045(X)
SE7355F5545(X)
SE7355F5045(X)
SE7305C5545(X)
SE7305C5045(X)
SE7305F5545(X)
SE7305F5045(X)
SE7305F5545(X)-ECM
SE7305F5045(X)-ECM
COMMUNICATION OPTIONS
Replace (X) with one of the following letters for communication protocols:
•
Outdoor air sensor
•
Remote sensor
Does not apply to all models, refer to specic model technical manual for details
*
*
*
On-Off,
2H/2C
Heat pump,
1, 2 compressors
Rev. valve
Aux. heat
On-Off, 2H/2C,
Humidity
On-Off,
2H/2C,
Economizer
WaterSource HP
1, 2 compressors
Rev. valve
Humidity
On-Off, 2H/2C,
Analog heat,
2
CO
control
On-Off, 2C,
Analog Heat
SE7652B5545(X)
SE7652B5045(X)
SE7652H5545(X)
SE7652H5045(X)
SE7657B5545(X)
SE7657B5045(X)
SE7656B5545(X)
SE7656B5045(X)
SE7652W5545(X)
SE7652W5045(X)
SE7656E5545(X)
SE7656E5045(X)
SE7652F5545(X)
SE7652F5045(X)
Hospitality / Lodging
•
Sames as above
but 2 pipe only or
2 pipe + reheat
•
Up to 3 speed
fan control
SC3000 model with inputs required for 2 pipe with changeover sensor
*
On-Off, 1H/1C,
Pulsed reheat
*
On-Off, 1H/1C,
Pulsed reheat,
4 remote inputs
SC3400E5045 SER7305A5545(X)
SC3404E5045
SC3300E5045
SEZ7656 & SEZ7260 Controllers
Low Voltage (24VAC) Zoning System Applications
1
Building
Function
•
Rooftop/Heat pump
•
Single fan speed
•
Frost protection
•
By-pass damper
•
Economizer
2
Applications /
Features
3 4 5 6 7
Function
Roof Top Unit
Outputs /
Inputs
On-Off,
2H/2C
Heat pump,
3H/2C
On-Off, 2C,
Controller
Analog heat
On-Off, 2H/2C,
2
CO
Econo.
Motion
Sensor
SER7305A5045(X)
BACnet Wireless
SEZ7656R1045B SEZ7656R1045W
SEZ7656H1045B SEZ7656H1045W
SEZ7656F1045B SEZ7656F1045W
SEZ7656E1045B SEZ7656E1045W
BACnet®
4
B
Echelon®
4
E
Wireless
Models without Echelon option
4
W
ZigBee® Pro
4
P Network Ready
4
None
•
Pressure dependent
Commercial
VAV zone control
•
Binary inputs
•
CO2 input
Floating
Heat
Reheat
Analog damper
Heat
Zone Controller
Reheat
damper
SEZ7260C5545B SEZ7260C5545W
SEZ7260C5045B SEZ7260C5045W
SEZ7260F5545B SEZ7260F5545W
SEZ7260F5045B SEZ7260F5045W