Schneider Electric SE7000 Quick Reference

SE7000 Quick Reference Guide
SE7200 & SE7300 Controllers
Low Voltage (24VAC) Zone and Fan Coil Unit Applications
1 2 3 4 5 6
Building
Function
Applications / Features
2 or 4 pipe
Hot/chill water valves
Automatic changeover
Auxiliary contact output
Zone
Binary Inputs
2 or 4 pipe
Up to 3 speed fan control
Hot/chill water valves
Automatic changeover
Auxiliary contact output
Binary inputs
Commercial
ECM fan control
2 pipe
Hot/chill water valve
Automatic changeover
Auxiliary contact output
Binary inputs
Humidity
Control
Outputs /
Inputs
Floating or On-Off, 1H/1C, Reheat
Analog, 1H /1C, Reheat
Floating or On-Off, 1H/1C, Reheat
Analog, 1H/1C, Reheat
Floating or On-Off, 1H/1C, Reheat
Analog, 1H/1C, Reheat
Analog, 1H/1C, Reheat
Motion Sensor
SE7200C5545(X)
SE7200C5045(X)
SE7200F5545(X)
SE7200F5045(X)
SE7350C5545(X)
SE7350C5045(X)
SE7350F5545(X)
SE7350F5045(X)
SE7300C5545(X)
SE7300C5045(X)
SE7300F5545(X)
SE7300F5045(X)
SE7300F5545(X)-ECM
SE7300F5045(X)-ECM
Network Ready
Controller
Low Voltage (24VAC) Rooftop and Heat-Pump Applications
1
Building
Function
Roof top
Heat pump
Single fan speed
Frost protection
Auxiliary contact output
Commercial
Digital inputs
Discharge air sensor
SE7600 Controllers
2
Applications / Features Scheduling
*
*
*
*
3 4 5 6
Outputs /
Inputs
On-Off, 1H/1C
On-Off, 2H/2C
Heat pump, 1, 2 compressors Rev. valve Aux. heat
On-Off, 2H/2C, Humidity
On-Off, 2H/2C, Economizer
WaterSource HP 1, 2 compressors Rev. valve Humidity
On-Off, 2H/2C, Analog heat,
2
CO
control
Economizer
On-Off, 2C, Analog heat
On-Off, 1H/1C
Motion Sensor
Network Ready
Controller
SE7600A5545(X)
SE7600A5045(X)
SE7600B5545(X)
SE7600B5045(X)
SE7600H5545(X)
SE7600H5045(X)
SE7607B5545(X)
SE7607B5045(X)
SE7605B5545(X)
SE7605B5045(X)
SE7600W5545(X)
SE7600W5045(X)
SE7606E5545(X)
SE7606E5045(X)
SE7600F5545(X)
SE7600F5045(X)
SE7652A5545(X)
SE7652A5045(X)
SER7300 Controllers & SC3000 Relay Pack
Line Voltage Fan Coil Unit Applications
1 2 3 4 1 2 3
Building
Function
Commercial
Applications /
Features
2 or 4 pipe
Up to 3 speed
fan control
2 Binary inputs
(SER7300)
Auto changeover 4 pipe or 2 pipe + reheat
Sames as above but 2 pipe only or 2 pipe + reheat
Up to 3 speed fan control
2 or 4 pipe
Up to 3 speed fan control
2 Binary inputs (SER7300)
Auto changeover 4 pipe or 2 pipe + reheat
*
*
*
Outputs /
On-Off, 1H/1C
On-Off ,1H/1C, 4 remote inputs,
On-Off , 1H/1C, 4 remote inputs, Occ output
On-Off , 1H/1C, Pulsed reheat
On-Off, 1H/1C, Pulsed reheat, 4 remote inputs
On-Off, 1H/1C
On-Off, 1H/1C, 4 remote inputs,
On-Off, 1H/1C, 4 remote inputs, Occ output
Relay Pack
SC3500E5045
SC3504E5045
SC3514E5045
SC3400E5045 SER7300A5545(X)
SC3404E5045
SC3300E5045
SC3500E5045
SC3504E5045
SC3514E5045
Humidity
Control
Motion Sensor
SER7350A5545(X)
SER7350A5045(X)
SER7300A5045(X)
SER7355A5545(X)
SER7355A5045(X)
Network Ready
Controller
2 or 4 pipe
Up to 3 speed fan control
Hot/chill water valves
Automatic changeover
Auxiliary contact output
Binary inputs
Hospitality / Lodging
ECM fan control
2 pipe
Hot/chill water valve
Automatic changeover
Auxiliary contact output
Binary inputs
Floating or On-Off, 1H/1C, Reheat
Analog, 1H/1C, Reheat
Floating or On-Off, 1H/1C, Reheat
Analog, 1H/1C, Reheat
Analog, 1H/1C, Reheat
SE7355C5545(X)
SE7355C5045(X)
SE7355F5545(X)
SE7355F5045(X)
SE7305C5545(X)
SE7305C5045(X)
SE7305F5545(X)
SE7305F5045(X)
SE7305F5545(X)-ECM
SE7305F5045(X)-ECM
COMMUNICATION OPTIONS
Replace (X) with one of the following letters for communication protocols:
Outdoor air sensor
Remote sensor
Does not apply to all models, refer to specic model technical manual for details
*
*
*
On-Off, 2H/2C
Heat pump, 1, 2 compressors Rev. valve Aux. heat
On-Off, 2H/2C, Humidity
On-Off, 2H/2C, Economizer
WaterSource HP 1, 2 compressors Rev. valve Humidity
On-Off, 2H/2C, Analog heat,
2
CO
control
On-Off, 2C, Analog Heat
SE7652B5545(X)
SE7652B5045(X)
SE7652H5545(X)
SE7652H5045(X)
SE7657B5545(X)
SE7657B5045(X)
SE7656B5545(X)
SE7656B5045(X)
SE7652W5545(X)
SE7652W5045(X)
SE7656E5545(X)
SE7656E5045(X)
SE7652F5545(X)
SE7652F5045(X)
Hospitality / Lodging
Sames as above but 2 pipe only or 2 pipe + reheat
Up to 3 speed fan control
SC3000 model with inputs required for 2 pipe with changeover sensor
*
On-Off, 1H/1C, Pulsed reheat
*
On-Off, 1H/1C, Pulsed reheat, 4 remote inputs
SC3400E5045 SER7305A5545(X)
SC3404E5045
SC3300E5045
SEZ7656 & SEZ7260 Controllers
Low Voltage (24VAC) Zoning System Applications
1
Building
Function
Rooftop/Heat pump
Single fan speed
Frost protection
By-pass damper
Economizer
2
Applications /
Features
3 4 5 6 7
Function
Roof Top Unit
Outputs /
On-Off, 2H/2C
Heat pump, 3H/2C
On-Off, 2C,
Controller
Analog heat
On-Off, 2H/2C,
2
CO
Econo.
Motion Sensor
SER7305A5045(X)
BACnet Wireless
SEZ7656R1045B SEZ7656R1045W
SEZ7656H1045B SEZ7656H1045W
SEZ7656F1045B SEZ7656F1045W
SEZ7656E1045B SEZ7656E1045W
BACnet®
4
B
Echelon®
4
E
Wireless
Models without Echelon option
4
W
ZigBee® Pro
4
P Network Ready
4
None
Pressure dependent
Commercial
VAV zone control
Binary inputs
CO2 input
Floating Heat Reheat
Analog damper Heat
Zone Controller
Reheat
damper
SEZ7260C5545B SEZ7260C5545W
SEZ7260C5045B SEZ7260C5045W
SEZ7260F5545B SEZ7260F5545W
SEZ7260F5045B SEZ7260F5045W