Schneider Electric H84xxV Series, H84xxVB Series, H84xxVBS Series Specifications

Power Monitoring Single-Circuit |
Power Meter for Voltage-Mode CTs
H84xxV, H84xxVB, & H84xxVBS Series
BACnet
Connectivity
Via E8951 Gateway
REVENUE GRADE POWER METER
FOR VOLTAGE MODE CTS.
DESCRIPTION
The H84xxV, H84xxVB, and H84xxVBS Series digital power meters deliver high accuracy and high value at a competitive price. Whether you are looking for a 1-phase pulse output meter to monitor kWh, or a 3-phase communicating meter to monitor THD, the H84xxV Series has the right meter for you, in panel and wall mounting styles for your convenience. The pulse output unit offers two pulse outputs. While kWh is standard, the second pulse output provides a field-selectable choice between phase loss or kVARh. The Modbus communications unit offers a choice between two data outputs, Full Data Set (FDS) or Extended Data Set (EDS). Data points are listed on the next page.
FEATURES
• Revenue Grade measurements
• Intuitive navigation with context-sensitive menus for easy use
• Panel, wall, DIN rail mount...provide mounting flexibility
• These digital power meters automatically detect and correct phase reversal, eliminating the need to be concerned with CT load orientation...fast, trouble-free installation
• Real-time power monitoring via local display or through control/data acquisition systems
• Large, easy-to-read display
• Multiple values displayed at the same time on an anti-glare display featuring a green back-light
SPECIFICATIONS
INPUTS
Control Power 100 to 415 ± 10% Vac, 5 VA, 45 to 60 Hz*
DC 125 to 250 Vdc ± 20% Vdc, 3 W, exte rnal current limi ting required
Voltage Input UL: 600 Vac; C E: 300 Vac (L-N)
CURRENT INPUT
CT Scaling Primar y: Adjustable f rom 5 A to 32,767 A
Measurement Input Range
Current an d Voltage 0.5%
Power ANSI C12.16, 1%
Measurement - True RMS True RMS up to 15th harmo nic, 3-phase AC Syste m
Pulse Out put #1
Pulse Out put #2 (H84 63V/ VB/VBS)
Weight
Protection Class V: IP40 front, I P30 back; VB: NEMA 1, IP40
Altitude of Operation
Operating Temp Range
Storage Temp Range Meter and Di splay: -40 to 85 °C (-4 0 to 185 °F)
Humidity Range 0 to 95% non-c ondensing; indoor u se only
Agency Approvals
Limited Warranty 5 years
* For control voltages >415 Vac to 600 Vac order H84xxVBS
1 V RMS full s cale (+20% over-range). CTs must b e rated for use wit h Class 1 volt age inputs
ACCURACY
OUTPUTS
(kWh) N.O. Static Ou tput (240 Vac or 300 Vdc, 100 mA max . @ 25 ˚C, derate 0.56 m A per ˚C above 25 ˚C) 2.41 kV RMS isola tion
(Phase Loss o r kVARh) N.C. Static Output (240 Vac or 30 0 Vdc, 100 mA max. @ 25 ˚C, derate 0. 56 mA per˚C above 25˚C) 2.41 kV RMS isolatio n
MECHANICAL
H84xx V: 0.8 lbs; H84xxVB: 6.35 lbs; H84xx VBS: 9.15 lbs
ENVIRONMENTAL
3000 m
Meter: 0 to 6 0 °C (32 to 140 °F); Display: -10 to 50 °C (14 to 122 °F)
UL508; Cat . III, Pollution Degre e 2, for distribu tion systems up to 347VAC (L-N)/600VAC (L-L);
CE per IEC61010-1, Cat. III, Pollutio n Degree 2, for dist ribution sys tems up to 300 Vac (L-N)/480 Vac (L-L)
WARRANTY
APPLICATIONS
• Energy monitoring in building automation systems
• Renewable energy
• Energy management
• Commercial submetering
• Industrial monitoring
• Cost allocation
ACCESSORIES
Fuse Kits (AH02, AH03, AH04) DIN Rail Mounting Kit (AH23) Modbus-to-BACnet Converter (E8951) Modbus TCP Gateway (U013-0012)
AH04
E8951
AH23
U013-0012
TM
HQ0001713.E 0116
3.6"
ORDERING INFORMATION
Power Monitoring Single-Circuit | H84xxV, H84xxVB, & H84xxVBS Series
*
DIMENSIONAL DRAWINGS
MODEL DESCRIPTION DATA OUTPUT DISPLAY SCREENS
PANEL MOUNT - 120 to 480 V
(For Contro l Voltages > 415 Vac to 600 Vac,
Pulse Modbus FDS EDS
order H84xx VBS)
H84 63V*
H8453V *
H8436V
H8437V
Panel Mo unt, 1 V, CT Inpu t, FDS
Panel Mo unt, 1 V, CT Inpu t, FDS
Panel Mo unt, 1 V, CT Inpu t, FDS
Panel Mo unt, 1 V, CT Inpu t, EDS
WALL MOUNT - 120 to 480 V
n n
n n
n n
n n
Pulse Modbus FDS EDS
(For Contro l Voltages > 415 Vac to
600 Vac, ord er H84xxVBS)
H84 63VB* Wall Mount, 1 V, CT Input , FDS
H8453V B* Wall Mount, 1 V, CT Input , FDS
H8436VB Wall Mount, 1 V, CT Inp ut, FDS
H8437VB Wall Mount, 1 V, CT Inp ut, EDS
WALL MOUNT - 240- 600V Pulse
H8463VBS* Wall Mount, 1 V, CT Inpu t, FDS, 240 to 600 V
H8453VBS** Wall Mount, 1 V, CT Input, FDS, 240 to 6 00 V
H8436VBS Wall Mount, 1 V, CT Inpu t, FDS, 240 to 600 V
H8437VBS
*The CE mark indicates RoHS2 compliance. Please refer to the CE Declaration of Conformity for additional details. **The H8453 has two normally open solid-state outputs: one kWh and one field­selectable for phase loss or kVARh. The H8463 has one normally open output (kWh) and one normally closed output (field selectable for phase loss or kVAR).
Wall Moun t, 1 V, CT Input, FD S, 240 to 600 V
n n
n n
n n
n n
n n
n n
Modbus
FDS EDS
n n
n n
DATA OUTPUTS
H8436: Full Data Set (FDS) kWh, Consumption kW, Real Power kVAR, Reactive power kVA, Apparent power Power factor Voltage, line to line Voltage, line to neutral Amps, Average current kW, Real power ØA kW, Real power ØB kW, Real power ØC Power factor ØA Power factor ØB Power factor ØC Voltage, ØA to ØB Voltage, ØB to ØC Voltage, ØA to ØC Voltage, ØA to Neutral Voltage, ØB to Neutral Voltage, ØC to Neutral Amps, Current ØA Amps, Current ØB Amps, Current ØC
H8437: Extended Data Set (EDS) (FDS Plus): Amps, Current Neutral Frequency kVAh, Consumption kVARh, Consumption Minimum Real power Maximum Real power KVA, Apparent Power, Per Phase KVAR, Reactive Power, Per Phase KW, Total Real Power Present Demand KVA, Total Apparent Power Present Demand KVAR, Total Reactive Power Present Demand KW, Total Real Power Max Demand KVA, Total Apparent Power Max Demand KVAR, Total Reactive Power Max Demand THD, Voltage A-N, B-N, C-N THD, Voltage A-B, B-C, A -C THD, Current, Per Phase Usage Hours Usage Minutes Total Hours Total Minutes
+0.8
3.6"
–0.0
(92 mm)
+0.8 –0.0
(92 mm)
2"
8.3"
(210 mm)
H8400 SERIES
(104 mm)
4.1"
9.1"
(242 mm)
(50 mm)
0.8"
(19 mm)
3.9"
(96 mm)
COMPANION CURRENT TRANSFORMERS
(Model/Amps)
H681
Small:
0-100 = 100 A 0-200 = 200 A 0-300 = 300 A
Medium:
1-400 = 400 A 1-600 = 600 A 1-800 = 800 A
Large:
2-800 = 800 A 2-1600 = 1600 A 2-2000 = 2000 A 2-2400 = 2400 A
(Output Type)
1V
= 0 to 1 Vac
Example:
H681 2-800 – 1V
3.9"
(96 mm)
HQ0001713.E 0116