Scarlett SC-AH986E12 User Manual [ru]

SC-AH986E12
www.scarlett.ru
INSTRUCTION MANUAL
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ІНСТРУКЦІЯ З ЕКСПЛУАТАЦІЇ ПАЙДАЛАНУ ЖӨНІНДЕГІ НҰСҚАУЛЫҚ
GB HUMIDIFIER ......................................................................................................... 3
RUS УВЛАЖНИТЕЛЬ ВОЗДУХА ........................................................................... 5
UA ЗВОЛОЖУВАЧ ПОВІТРЯ ............................................................................... 7
KZ АУА ЫЛҒАЛДАҒЫШЫ .................................................................................... 10
PL NAWILŻACZ POWIETRZA .............................................................................. 12
IM020
2
GB DESCRIPTION
RUS УСТРОЙСТВО ИЗДЕЛИЯ
1. Water tank
2. Mist nozzle
3. Water tank cap
4. Water inlet
5. Water tank base
6. Cabel with plug
7. ON/OFF button, mist output lever setting (1/2/3)
8. Timer setting button
9. Display
10. Essential oil cup
11. Membrane
12. Float
1. Резервуар для воды
2. Распылитель пара
3. Крышка резервуара
4. Отверстие для залива воды
5. База
6. Вилка и шнур питания
7. Кнопка включения, настройки интенсивности.
8. Кнопка настройки уровня влажности.
9. Дисплей
10. Аромакапсула
11. Мембрана
12. Поплавок
UA БУДОВА ВИРОБУ
1. Резервуар для води
2. Розпилювач пари
3. Кришка резервуару
4. Отвір для заливання води
5. База
6. Вилка та шнур живлення
7. Кнопка вмикання, налаштування інтенсивності.
8. Кнопка налаштування таймера
9. Дисплей
10. Аромакапсула
11. Мембрана
12. Поплавок
KZ ӨНІМНІҢ ҚҰРЫЛЫМЫ
1. Су резервуары
2. Бу бүріккіші
3. Резервуар қақпағы
4. Су құю саңылауы
5. Табаны
6. Аша және қуат сымы
7. Қосу, қарқындылықты реттеу түймесі
8. Таймерді реттеу түймесі
9. Дисплей
10. Аромакапсула
11. Ультрадыбыстық жарғақ
12. Қалтқы
PL BUDOWA WYROBU
1. Zbiornik na wodę
2. Rozpylacz pary
3. Pokrywa zbiornika
4. Otwór wlewu wody
5. Baza
6. Wtyczka i przewód zasilający
7. Przycisk włączenia, ustawienia intensywności.
8. Przycisk ustawienia timera
9. Wyświetlacz
10. Dozownik zapachów
11. Membrana
12. Pływak
220-240 V ~ 50 Hz
Класс защиты II
23 W
0.8 / 1.05 kg
mm
195
270
194
www.scarlett.ru SC-AH986E12
3
IM020
GB INSTRUCTION MANUAL
IMPORTANT SAFEGUARDS
Please read this instruction manual carefully before use and keep in a safe place for future reference. Before the first connecting of the appliance check that voltage indicated on the rating label corresponds
to the mains voltage in your home.
For home use only. Do not use for industrial purposes. Do not use the appliance for any other purposes
than described in this instruction manual.
Do not use outdoors. Always unplug the appliance from the power supply before cleaning and when not in use. To prevent risk of electric shock and fire, do not immerse the appliance in water or in any other liquids. If
it was happened DO NOT TOUCH the appliance, unplug it immediately and check in service center.
Do not take this product into a bathroom or use near water. The appliance is not intended for use for physically, sensory or mental disabled person (including
children) or for person with lack of life experience or knowledge, if only they are under supervision or have been instructed about the use of the unit by responsible person.
Children must be under control in order not to be allowed to play with the appliance. Do not use other attachments than those supplied. In case of power cord is damaged, its replacement should be done by the manufacture or service
department or the other high-skill person to avoid any danger.
Do not attempt to repair, adjust or replace parts in the appliance. Check and repair the malfunctioning
appliance in the nearest service center only.
Keep the cord away from sharp edges and hot surfaces. Do not pull, twist, or wrap the power cord around appliance. Do not pour the rest water from the gullet when humidifier connected to power supply. When wash humidifier, avoid leaking the water into the inner parts of humidifier otherwise the spare part
will be humid and cause problem.
When switch on the appliance, do not touch the energy-exchanger. Operate the appliance only with water in the tank. Do not add water over 40 °С into the water tank, or use
it for cleaning, to avoid possible deformation or discoloring.
Take the humidifier under bottom and support water tank when handle. Do not add water through the mist outlet. Do not add water directly to the water channel on the base. Do not add metals or chemicals into the water tank and the water channel on the base. Avoid water freezing in the humidifier. Do not lift the water tank while the humidifier is working. Do not pour water from the water channel when humidifier connected to power supply. Otherwise the
energy exchanger will immediately break.
Do not place humidifier close to the ventilating hole and keep away from the furniture and other electrical
appliances.
If the unit was got from the environment with temperature < 0 ºC, keep it under the room conditions at
least 2 hours.
ATTENTION: unplug the device from the socket before filling or cleaning. NOTE. During operation it is acceptable that white bloom occurs on the nearby objects which is caused
by high-salinity water being used, in this case we it is recommended to fulter the water before pouring it to water tank of the device.
The manufacturer reserves the right to introduce minor changes into the product design without prior
notice, unless such changes influence significantly the product safety, performance, and functions.
Manufacturing date is indicated on the unit and/or on packing as well as in accompanying documents in
the following format XX.XXXX where first two figures XX is the month of production, and following four figures XXXX is the year of production.
OPERATION
This appliance is used for indoors air humidifying Place the device on an even dry surface. ATTENTION: Before pouring water inside, unplug the device Remove the reservoir and unscrew the cover, pour in clean water and tightly screw the cover fixing
device.
ATTENTION: This appliance allows tap water usage. Purified water is still more preferable for usage,
especially if tap water is too hard. If tap water is too hard, fill in only distilled or demineralized water.
Water tank capacity is 4 l. Wipe the surface of water tank with a dry cloth. Place the water tank onto the base Insert the plug into the socket and switch on the appliance using the on/off dial.
www.scarlett.ru SC-AH986E12
IM020
4
PROBLEMS
CAUSE
SOLUTION
The mist is smelling
1. The appliance is new
2. Water is dirty
1. Wash the tank and change the water Open
the water tank and ventilate it for 12 hours
The Indicator light is on, no mist out and no air coming
The water level is excessive high
1. Switch off the appliance and unplug it
2. Take the water tank off and unscrew the
water inlet lid. Pour off some water and
Switch on.
To turn on the humidifier, press the power button and adjust the humidification intensity . The moistening process will start automatically. The display will turn blue.
Moisture intensity setting
To adjust the intensity of humidification, after switching on, press the button again the desired
number of times.
The display will show your chosen intensity level (from 1 to 3).
Humidity setting
To adjust the level of humidity in the room, press the button the desired number of times. The
display will show the selected humidity level from 40% to 80%. The most comfortable for people is the humidity level of the room is 50-60%.
When the humidity in the room reaches the set level, the unit automatically turns off. The reached
humidity level will be shown on the display.
Aromafunction / Essential oil
Put no more than 2-3 drops of essential oil into the essential oil cup before placing water tank onto the
base and turning the unit on.
Turn on the unit as indicated above. And the scented will be come out with the wind after turn on the machine
Water level indication
When water level it too lowl, the unit will automacially turn off and water level indicator will turn red. This
means that filling tank with water is needed.
CLEAN AND CARE
Do not forget to unplug the appliance from the power supply before cleaning.
WASH WATER TANK (EVERY TWO OR THREE WEEKS)
Take off the water tank and turn it up. Unscrew the cover. Wipe with a soft cloth and rinse water valve. Wash water tank with warm water (<40 ºC)
CLEAN THE WATER CHANNEL AND THE ENERGY EXCHANGER (ONCE A WEEK).
If there is scale in the gullet, clean it with soapy water then rinse with water. If there is any stain on the energy exchange, wipe them off with the soft cloth. Then rinse the appliance
with clean water.
IMPORTANT: Use only a soft cloth to clean the energy exchanger. Never touch it with sharp or hard objects.
WASH THE EXTERNAL SURFACE OF HUMIDIFIER
First rub the scale and then wash with soft cloth and warm water (<40 ºC). Wash the head of sprayer with water directly.
IMPORTANT: Do not use chemicals, organic solvents or aggressive liquids and abrasives. .
SCALE REMOVAL
Hard scale is not allowed to be removed from the unit surfaces mechanically. Fill water tank with water solution of vinegar, one liter of water needs 150ml of vinegar. Instead of vinegar
soda can be used, one liter of water needs 2 table spoon of baking soda.
The nozzle of the unit should face open window, so that water mist is directed outdoors. Switch air humidifier for 30-60min Water with soda or with vinegar will eat the scale away during unit usage, so that after the procedure the
scale will be removed from the unit walls.
STORAGE
Switch off and unplug the appliance. Complete all requirements of chapter CLEAN AND CARE. Keep assembled appliance in a dry cool place.
COMMON PROBLEMS AND SOLUTIONS
www.scarlett.ru SC-AH986E12
5
close the lid tightly. Wipe the tank dry with a soft cloth. Place water tank back on the base
3. Plug the humidifier in. Turn it on
The mist is poor
The energy-changeable appliance has scale or the water is dirty
Wash the energy-changeable appliance and change water
The symbol on the unit, packing materials and/or documentations means used electrical and electronic units and battery’s should not be toss in the garbage with ordinary household garbage. These units should be pass to special receiving point. For additional information about actual system of the garbage collection address to the local authority. Valid utilization will help to save valuable resources and avoid negative work on the public health and environment which happens with incorrect using garbage.
RUS РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
МЕРЫ БЕЗОПАСНОСТИ
Внимательно прочитайте Руководство по эксплуатации и сохраните его в качестве справочного
материала.
Перед первоначальным включением проверьте, соответствуют ли технические характеристики,
указанные на изделии, параметрам электросети.
Использовать только в бытовых целях в соответствии с данным Руководством по эксплуатации.
Прибор не предназначен для промышленного применения.
Не использовать вне помещений. Всегда отключайте устройство от электросети перед очисткой, или если Вы его не используете. Во избежание поражения электрическим током и возгорания, не погружайте прибор в воду или
другие жидкости. Если это произошло, НЕ БЕРИТЕСЬ за изделие, немедленно отключите его от электросети и обратитесь в Сервисный центр для проверки.
Не пользуйтесь устройством в ванных комнатах и около воды. Прибор не предназначен для использования лицами (включая детей) с пониженными
физическими, сенсорными или умственными способностями или при отсутствии у них жизненного опыта или знаний, если они не находятся под присмотром или не проинструктированы об использовании прибора лицом, ответственным за их безопасность.
Дети должны находиться под присмотром для недопущения игр с прибором. Не используйте принадлежности, не входящие в комплект поставки. При повреждении шнура питания его замену, во избежание опасности, должны производить
изготовитель, сервисная служба или подобный квалифицированный персонал.
Не пытайтесь самостоятельно ремонтировать устройство. При возникновении неполадок
обращайтесь в ближайший Сервисный центр.
Следите, чтобы шнур питания не касался острых кромок и горячих поверхностей. Не тяните за шнур питания, не перекручивайте и не наматывайте его вокруг корпуса устройства. Не выливайте оставшуюся воду через распылитель пара. Во время чистки увлажнителя не допускайте попадания воды во внутреннюю часть прибора – это
может вывести его из строя.
При включении прибора не прикасайтесь к ультразвуковой мембране. Включайте увлажнитель только при наличии воды в резервуаре. Не наливайте в резервуар и не
используйте для мытья воду с температурой выше 40 ºC во избежание деформации или обесцвечивания корпуса.
При перемещении увлажнителя беритесь только за основание, при этом придерживая резервуар
для воды.
Не наливайте воду через распылитель пара. Не наливайте воду напрямую через трубку для подачи воды в корпусе. Не допускайте попадания металлов и химикатов в резервуар и трубку подачи воды в корпусе. Не допускайте замерзания воды в резервуаре. Не снимайте резервуар для воды во время работы прибора. Не выливайте всю воду из резервуара, если прибор включен в сеть. Иначе ультразвуковая
мембрана выйдет из строя.
Не размещайте увлажнитель в непосредственной близости от мебели и электроприборов, а также
не устанавливайте его около вентиляционных отверстий.
Если изделие длительное время находилось при температуре < 0 ºC, перед включением его
следует выдержать в комнатных условиях не менее 2 часов.
www.scarlett.ru SC-AH986E12
IM020
Loading...
+ 10 hidden pages