INTRODUCTION
The ECOSY 24 E and ECOSY 28 E boilers are wall
mounted combination boilers providing central
heating and instantaneous hot water.
The ECOSY SB 24 E and ECOSY SB 28 E boilers are
wall mounted system boiler providing central
heating only.
The ECOSY 24 E and ECOSY SB 24 E boilers are of the
II2H3+ category for use with Natural Gas (G20) and
Liquide gas (G30 and G31)as distributed in the
United Kingdom.
The ECOSY 28 E and ECOSY SB 28 E boilers are of the
I2H category for use with Natural Gas (G20) as
distributed in the United Kingdom.
The boilers have a fan assisted balanced flue which
both discharges the products of combustion to and
draws the combustion air from the outside of the
room.
The boilers are suitable for top outlet flue connection
only but, can be fitted with horizontal flue, vertical
flue or twin-pipe flue. Refer to flue catalogue for
further details.
On ECOSY 24 E and ECOSY 28 E, both the central
heating and domestic hot water temperature are
user adjustable from the boiler control panel.
On the ECOSY 24 E and ECOSY 28 E, domestic hot
water demand always has priority over heating
demand.
The boiler is designed for use as part of a sealed
water central heating system with fully pumped
circulation. The pump, expansion vessel and
associated safety devices are all fitted within the
boiler.
The boiler can be installed against either an external
wall or on an adjacent inside wall, that is, the flue
system will pass directly to the rear or to either side
to the terminal fitted on the outside wall face.
The installation must be carried out by a competent
person in accordance with the relevant
requirements of The Building Regulations, The Water
Byelaws, The Building Standards (Scotland)
Regulations and any applicable local regulations.
These instructions should be carefully followed for
the safe and economical use of your boiler.
Ancillary equipment
A range of flue accessories are available including
vertical flues, twin-pipe flues, bends etc.
For further information contact your supplier.
On ECOSY SB 24 E and ECOSY SB 28 E, the central
heating temperature is user adjustable from the
boiler control panel.
COMMISSIONING
Gas safety (Installation and use) Regulations
In your interests and that of gas safety, it is the law
that ALL gas appliances are installed and serviced
by a competent person in accordance with the
above regulations.
Gas leak or fault
If a gas leak or fault exists or is suspected, turn the
boiler off and consult the local gas supply company
or your installation/service company.
Boiler controls
The control panel, located at the lower front of the
boiler casing, see diagram 1, allows the boiler to be
started, shut down, controlled and monitored during use.
Diagram. 1
OPENING THE CONTROL PANEL COVER
Ins 048a
Flue
Do not obstruct the outside terminal of the boiler.
Starting the boiler
Before starting the boiler check that:
- The gas meter tap is open.
- The boiler gas service cock is open.
- The boiler is connected to the electrical supply and
turned on.
3
CONTROLS AND LIGHTING
OFF
ON
OFF
ON
The control panel, located at the lower front of the boiler casing, see diagram 2, allows the boiler to be
started, shut down, controlled and monitored during use.
● The boiler is connected to the electrical supply.
● The boiler gas service cock is open.
● The pressure gauge reads between 1 and 2 bar.
06 5
5 - Display
6, 7, 8 and 9 - Program selection buttons
10 - Pressure gauge
7654312
MODE
Stopping the boilerStarting the boiler
➜ PUSH IN BUTTONIN
STOP THE BOILER
ENTER
SETPC
98
2
SUMMER POSITION
10
2
bAR
1
3
4
O
IMIT
Hab 197a
TO
➜ PUSH IN BUTTONTO START BOILER
1
➜
ON
SETTING TO SUMMER MODE
(Hot water only)
➜ PUSH BUTTONTOPOSITION TO SET THE
BOILER TO SUMMER MODE
2
OFF
➜
ON
OFF
➜
To ensure maximum life of the boiler control
system, it is recommended that the mains is left
switched on all the time. Power consumption
during stand by is only 7 to 8 watts.
SETTING TO WINTER MODE
(heating and hot water)
➜ PUSH BUTTONTOPOSITION
BOILER TO WINTER MODE
2
TO SET THE
➜
To obtain domestic hot water, open a hot water
tap.
4
Assuming that any remote heating controls are
calling for heat, the above procedure is all that
is required to start the boiler in heating mode.
Hot water has priority over heating.
CONTROLS AND LIGHTING
Setting domestic hot water temperature
1 - Press «Mode» button once
mode
➭➭
1.6 5
set
2.6 5
➜
2 - Press «+» or «-» button to set the desired hot water temperature from 40°C to 65°C
(factory set at 65°C)
+
3 - Press «enter» until the display starts flashing, and press «mode» twice : the boiler is now
operational at the desired hot water temperature.
enter
Note : On the SB versions, this setting is done using the tank thermostat in the tank.
1 - Press «Mode» button once 2 - Press «Set» button 4 times to show 5 on the left
-
2.60
set
Setting heating temperature
➭
2.60
➜
twice
➭➭
1.6 5
Hab 198a
1.60
-
➭
3 - Press «+» or «-» button to set the desired heating temperature from 20°C to 90°C
(factory set at 70°C)
➭➭
mode
4 - Press «enter» until the display starts flashing, and press «mode» twice : the boiler is now
operational at the desired heating temperature.
Note :
1/ In case of under floor heating systems, the CH flow temperature can be set to between 20°C and
45°C - contact
In all cases, by pressing the «Mode» button until the decimal point disappears, the display reverts to
normal position :
+
the Saunier Duval Technical Helpline 01773 828400.
1.6 5
-
➭
06 5
set
6.85
No decimal point displayed
mode
6.7 0
twice
Hab 198a
5
BOILER OPERATING MODES AND DISPLAY READINGS
The Ecosy display has three display modes :
A - Reading mode only - this gives information about the operation in progress.
B - Programming mode - this allows the user to change selected settings of the boiler.
C - Diagnostic mode - this allows the user to check selected temperatures during boiler operation.
A- Reading mode only
06 5
During boiler operation, the display gives information about the operation in progress (left
hand digit) and the temperature of that
operation (right hand digits).
0 - No demand➜
1 - Safety purge➜
2 - Ignition➜
3 - Boiler on - central heating➜
4 - Boiler on - hot water➜
5 - Waiting for closing air pressure switch ➜
6 - Boiler off after reaching temp.➜
7 - Pump overrun after heating➜
8 - Pump overrun after hot water➜
9 - Boiler safety shut down➜
No decimal point displayed
Flow temperature
06 5
16 5
26 5
36 5
46 5
56 5
66 5
76 5
86 5
96 5
Hab 206
C - Diagnostic mode :
set
1.7 0
➭
1.7 0
➭
3.5 0
Flashing decimal point displayed
Allows the user to check selected temperatures
during boiler operation.
1 - Press «Mode» button twice : The number 1
will be displayed with a flashing decimal point
after it.
mode
2 - Press «Set» button to select the setting that
you wish to check (see table below).
1 - Central heating flow temperature
2 - Central heating return temperature
3 - Cylinder temperature
4 - Not applicable
5 - Not applicable
6 - Not applicable
7 - Calculated temperature set
8 - Temperature rise of central heating flow
9 - Temperature rise of cylinder
Reg 025
B - Programming mode
Five settings of the boiler can be changed by
the user.
1 - Press «Mode» button once : The number 1
will be displayed with
a decimal point after
it.
2 - Press «Set» button to select the setting that
you wish to change (see table below).
ProgrammeSetting
1 ➜ Domestic hot water temperature ............................... adjustable from 40°C to 65°C (factory set at 65°C)
2 ➜ Domestic hot water comfort level...............................factory set at 02 - do not adjust
3 ➜ Pump operation.............................................................00 = do not use