Instruction Manual
Glass Door Reach-Ins
Models:
GF1R-1
GF2R-1
G1R-1
G2R-1
SUPERA Customer Care Toll-Free Service Line:
1-866-953-3288
For additional product and warranty
information, please visit our website at
www.SuperaCo.com
Contents
1. Preface ....................................................................................................................................... 3
2. Use of the Equipment ................................................................................................................ 3
3. Technical Features ..................................................................................................................... 4
4. Operation ................................................................................................................................... 4
5. Control Unit ................................................................................................................................ 4
6. Handling ..................................................................................................................................... 5
7. Installation Procedure ................................................................................................................ 5
8. Connecting to the Main Power Supply ...................................................................................... 5
9. Maintenance Instructions .......................................................................................................... 6
10. Troubleshooting ....................................................................................................................... 7
11. Technical service ...................................................................................................................... 7
12. Configuration Sketch Map ....................................................................................................... 7
©Supera
Operating Instructions .................................................................................................................... 8
Technical Parameters .................................................................................................................... 11
Offical Approval and Rules ............................................................................................................ 12
V.1.0 | October 2014
2
1. Preface
This Instruction manual provides all the necessary information regarding:
• Use of the refrigerator
• Technical specifications
• Installation and handling
• Operator procedures and instructions maintenance operation
The manual is to be considered an integral part of the refrigerator and should be stored in a
safe place for further consult to permit a good working life of the refrigerator.
ATTENTION
The manufacturer cannot be held liable in the following cases:
• Improper installation (not in accordance with the guidelines indicated in this manual)
• Misuse of the refrigerator
• Power supply defects
• Improper or inadequate maintenance
• Unauthorized modification or tampering
• Use of non-original spare parts
• Partial or total failure to comply with the instructions
All electrical equipment can be hazardous to health. Current standards and legal requirements
must be complied with during the installation and use of any equipment.
2. Use of the Equipment
The refrigerators are for preserving fresh perishable foods, with a built-in refrigerated unit.
The operating temperature for refrigeration is:
• between +2°C and +10°C at room temperature of +32°C an 60%RD.
The operating temperature for frozen food maintenance is:
• between -6°C and -18°C at room temperature of +32°C an 60% RD.
©Supera
V.1.0 | October 2014
3
3. Technical Features
The refrigerator is a ventilated system, the evaporator is in a separate insulated box on the top.
All the materials used in the manufacturing of this unit are guaranteed to be suitable for use
with perishable foods. The gases used in the refrigerators are R-134a; in the refrigerator for
frozen food maintenance is R-404a.
The refrigerating circuit is in compliance with the current normative.
4. Operation
The gas in the refrigerating circuit is first compressed, liquefied and then evaporated in the
ventilated evaporator, situated on the top of the container.
This cycle involves the absorption of heat from the air in the refrigerator compartment and is
then cooled. The heat produced is then dissipated to the outside environment by a condenser
unit located on the top of the refrigerator.
5. Control Unit
The refrigerator responds to commands from a "digital control unit" and a "main switch pilot
light" in the top panel of the refrigerator.
The "main switch pilot light" is for turning on the power supply.
The red pilot light comes on to indicate that the unit is connected to the main electricity and to
start work.
The red pilot light comes off to indicate that the unit is disconnected and doesn't work. The
"digital control unit" is for the regulation of all parameters to provide the correct working of the
refrigerator. Please consult all parameters in the attachment manual of the "digital control
unit".
This manual is part of the instruction manual and is very important in case of service.
Applied refrigerant belongs to non-flammable refrigerant.
©Supera
V.1.0 | October 2014
4