Sanyo VCC-5974P Instruction Manual

Page 1
INSTRUCTION MANUAL BEDIENUNGSANLEITUNG MANUEL D’INSTRUCTIONS
COLOUR CCD Camera CCD-Farbkamera Caméra CCD COULEUR
VCC-5974P
About this manual
Über diese Bedienungsanleitung
Lesen Sie bitte vor der Montage und dem Inbetriebnehmen der Kamera zuerst diese Bedienungsanleitung sorgfältig durch und bewahren Sie sie zum späteren Nachschlagen auf.
À propos de ce manuel
Avant d’installer et d’utiliser la caméra, veuillez lire ce manuel attentivement. Gardez-le à portée de main pour toute référence ultérieure.
Page 2
Depending on the conditions of use, installation and environment, please be sure to make the appropriate settings and adjustments. If you need help with installation and/or settings, please consult your dealer.
CONTENTS
PRECAUTIONS........................................................................................ 2
PARTS NAMES........................................................................................ 3
MOUNTING THE LENS........................................................................... 6
CONNECTIONS....................................................................................... 9
SETTINGS................................................................................................10
USING THE ON-SCREEN MENUS........................................................... 14
MENU DISPLAY......................................................................................15
ADJUSTMENTS.......................................................................................16
TROUBLESHOOTING..............................................................................28
SPECIFICATIONS.....................................................................................29
ACCESSORIES
1 C mount adaptor (5 mm)......................................................... 1 pc.
The C mount adaptor must be used to be able to install a C mount lens on the camera.
2 Lens iris plug (4-pin)................................................................. 1 pc.
3 Clamping core ......................................................................... 1 pc.
123
FEATURES
Built-in interline transfer method 1/3" CCD, approx. 470,000
picture elements
Low smear, anti-blooming, low lag, no burning and no geometric
distortion using the CCD solid state image device.
100% solid state components giving excellent immunity to shock
and vibration
Not subject to interference from magnetic or electrostatic fields
High sensitivity, minimum required illumination is 0.9 lux (F1.2,
AGC Gain: High, incandescent lighting)
Horizontal resolution, more than 460 TV lines
Power supply: 24 V AC operation
English 1
Page 3
PRECAUTIONS
In case of problem
Do not use the camera if smoke or a strange odour comes from the unit, or if it seems not to function correctly. Disconnect the power cord immediately, and consult your dealer (or a Sanyo Authorized Service Centre).
Do not open or modify
Do not open the cabinet, as it may be dangerous and cause damage to the unit. For internal settings and repairs, consult your dealer (or a Sanyo Authorized Service Centre).
Do not put objects inside the unit
Make sure that no metal objects or flammable substance get inside the camera. If used with a foreign object inside, it could cause a fire, short-circuits or damages.
If water or a liquid gets inside the camera, disconnect the power cord immediately, and consult your dealer (or a Sanyo Authorized Service Centre). Be careful to protect the camera from rain, sea water, etc.
Be careful when handling the unit
To prevent damages, do not drop the camera or subject it to strong shock or vibration.
Install away from electric or magnetic fields
If installed close to a TV, radio transmitter, magnet, electric motor, transformer, audio speakers the magnetic field they generate will distort the image.
Protect from humidity and dust
To prevent damages to the camera, do not install it where there is greasy smoke or steam, where the dampness may get too high, or where there is a lot of dust.
Protect from high temperatures
Do not install close to stoves, or other heat generating devices, such as spotlights, etc., or where it could be subject to direct sunlight, as that could cause deformation, discoloration or other damages.
Be careful when installing close to the ceiling, in a kitchen or boiler room, as the temperature may raise to high levels.
Install where the temperature range will stay between –10˚C and 50˚C. (no condensation)
Cleaning
Dirt can be removed from the cabinet by wiping it with a soft
cloth. To remove stains, wipe with a soft cloth moistened with a soft detergent solution and wrung dry, then wipe dry with dry soft cloth.
Do not use benzine, thinner or other chemical product on the
cabinet, as that may cause deformation and paint peeling. Before using a chemical cloth, make sure to read all accompanying instructions. Make sure that no plastic or rubber material comes in contact with the cabinet for a long period of time, as that may cause damage or paint peeling.
ENGLISH
2 English
Page 4
PARTS NAMES
1
1
3
4
2
3
7
8
1
4
5
6
2
3
2
1
1 Shorter screws: M3 x 4 2 Longer screws: M3 x 6 3 Camera mounting
screw hole: 1/4"-20 UNC
1 Lens iris output connector (4 pin)
This 4-pin connector is used to send the DC control signal and power supply to an auto-iris type lens.
2 Auto white balance push lock button (AWB LOCK) 3 Menu setting button (SET)
Connect the camera to the monitor, then press the SET button for about 3 seconds to display the on-screen menu.
2
4 Cursor button (CURSOR)
j: Press this button to move the cursor up. c: Press this button to move the cursor to the right, or to turn the settings ON/OFF etc. d: Press this button to move the cursor to the left, or to turn the settings ON/OFF. l: Press this button to move the cursor down.
5 Flange-back lock screw (FLANGE BACK LOCK) 6 Flange-back adjustment screw (FLANGE BACK ADJ.) 7 Lens mount cap
The cap is installed to protect the lens mount section. Remove the lens mount cap before installing a lens (sold separately).
8 Camera installation bracket
The bracket can be fixed at the top or bottom of the camera. When fixing the bracket, be sure to use the longer screws and install the shorter screws on the opposite side to seal the openings.
CAUTION:
When installing the camera support, select a location that can support the total weight of the camera and accessories.
English 3
Page 5
9
ON
2341 23
INT1OFF78OFF
a
bcdef
AGC ON WB
67
BLCSYNC FL
85910
OFF EI
9 Camera setup section (under the cover)
This unit factory settings are as indicated below. These settings are for when using a 1/3 inch CS mount DC (without EE internal amplifier) type lens. However, if due to installation conditions or environment the settings may need to be modified for best results (see "SETTINGS"). To access the controls, remove the cover fixing screw, then remove the cover.
Control name Position
High speed electronic shutter switches (ES) All OFF: 1/50 sec
a
Internal/Line lock switch (SYNC) INT
b
Auto gain control switch (AGC) ON
I
AIONES LL ON
R
I
S
g
c
White balance switch (WB) all ON: ATW
d
Backlight compensation switch (BLC) ON
e
Electronic iris (EI)/Auto iris (AI) switch AI
f
Auto-iris lens switch (A.I. LENS) DC
g
Notes:
When using a 1/2 or 2/3 inch C mount VIDEO (with EE internal amplifier) auto-iris type lens, set the A.I.
LENS switch to the VIDEO position.
The settings entered in the camera setup section can be displayed using the on-screen menu.
If not using an auto-iris lens, make sure the BLC switch is set to OFF.
4 English
Page 6
PARTS NAMES
F
G
F Video output connector (VIDEO OUT: BNC type)
Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector.
H
G External sync composite video signal input connector
(VBS IN: BNC type)
Connect to this connector the synchronizing signal output from a synchronizing signal device or the composite signal of a video distributor.
I
H Power indicator (POWER)
Comes on when the power to the camera is on.
I 24 V AC input terminal (24 V AC, GND)
Using a commercially available AC adaptor.
Flange-back adjustment
If the pick-up surface is not correctly positioned with relation to the lens focal point, the picture will be out of
1
focus (in particular when using auto-iris power zoom lenses, sold separately). If that is the case, adjust the flange-back position as described below.
1 Using a + screwdriver, loosen the FLANGE BACK LOCK screw (M2:+).
Set the zoom lens to the maximum telephoto position, set the focus using the focus ring on the lens.
ADJ.
2
1
LOCK
2 Set the zoom lens to the maximum wide angle position, set the focus using the FLANGE BACK ADJ.
3
screw.
3 Repeat steps 2 and 3, until the image stays in focus when changing from a telephoto shot to a wide
angle shot. When the setting is complete, tighten the FLANGE BACK LOCK screw.
English 5
Page 7
MOUNTING THE LENS
Check the lens mount
Do not use a lens if the length “L” is more than 5 mm. That may damage the camera and prevent proper installation.
L
Fig. 1
Installation of a DC type auto-iris lens (sold separately)
A 1/3 inch CS mount type lens without EE amplifier circuit that only uses a DC power source. This camera can receive (the A.I. LENS switch to the DC type) a CS mount type lens without the need of an adaptor.
If the lens plug shape or wiring does not correspond, please install the supplied plug as indicated in the pin layout table.
CAUTION:
When using an auto-iris lens, the supplied clamping core must be installed on the lens wire (see Fig. 1), in order to prevent electromagnetic interference to the other devices connected.
6 English
Page 8
MOUNTING THE LENS
Installation of a VIDEO type auto-iris lens (sold separately)
2 (A)
(B)
DC VIDEO
31
4
3
3
2
4
1
A 1/2 or 2/3 inch C mount type lens with EE amplifier circuit that uses the video signal and a DC power source.
1 Remove the lens mount cap. 2 Attach the supplied C mount adaptor (A) to the auto-iris lens (B), then install the assembly on the
camera.
3 Connect the lens plug to the LENS connector on the side of the camera.
If the lens plug shape or wiring does not correspond to the specifications below, connect the supplied plug as indicated.
When using lenses from other makers, make sure that the pins connections in the plug correspond to
the ones of the camera. Refer to the lens specifications to check the pins connections in the plug.
If they are different than indicated, remove the original plug and connect the supplied plug according
to the diagram.
4 Set the A.I. LENS switch in the camera setup section to the VIDEO position.
Pin layout
DC type lenses VIDEO type lenses
Brake coil (–) +12 V DC (50 mA max.)
1
Brake coil (+) Not used
2
Drive coil (+) Video output (1.0 Vp-p, high impedance)
3
Drive coil (–) Ground (for video signal and DC power)
4
2
4
English 7
Page 9
Compatible auto-iris lenses
1/3 inch Sanyo DC type lens 1/2 or 2/3 inch VIDEO type lens
VCL-CS8LY: Standard angle, f= 8 mm Standard angle, f= 9 mm VCL-CS4LY: Wide angle, f= 4 mm Telephoto angle, f= 12 mm VCL-CS2LY: Ultra-wide angle, f= 2.8 mm More telephoto angle, f= 16 mm
If using a VIDEO type auto-iris lens
Set the ALC and LEVEL controls on the lens to adjust the iris. Normally the ALC volume should be turned
all the way to Av (Average).
Depending on the type of lens used, the lens may not perform properly. In such a case, adjust the LEVEL
volume on the lens casing to correct.
8 English
Page 10
CONNECTIONS
1
(Video signal connections)
: VIDEO IN : VIDEO OUT
2
(A)
Basic connection for monitoring or recording
The peripheral devices (VCR, monitor, lens, etc.) and cables are sold separately.
1 Make the video signal connection between the camera and the monitor or time lapse VCR. 2 Connect the AC adaptor (sold separately) power cord to the 24 V AC input terminals, then plug the AC
adaptor to a wall outlet. The POWER indicator (A) will light. Adjust the picture on the monitor using the Brightness and Contrast
controls.
Coaxial cable type and maximum length
Cable type RG-59U (3C-2V), 250 m maximum.
Cable type RG-6U (5C-2V), 500 m maximum.
Cable type RG-11U (7C-2V), 600 m maximum.
CAUTION:
The RG-59U type cable should not be run through electrical conduits or through the air.
Use CCTV/Video-grade coaxial cable.
English 9
Page 11
SETTINGS
The illustration shows the factory default settings for the switches in the camera setup section. Depending on the camera installation location and conditions of use, it may be necessary to select other settings, without having to make adjustments. The selected settings can be confirmed using the on-screen menu. If adjustments are required, they can be entered using on-screen adjustment sub-menus (see ADJUSTMENTS, page 16).
BLCSYNC FL
AGC
2341 23
INT1OFF78OFF
ON WB
6785910
ON
OFF EI
I
AIONES LL ON
R
I
S
High speed electronic shutter (ES) setting
Normally, the three speed setting switches (1, 2 and 3) for the high speed electronic shutter are all set to the OFF position. This sets the electronic shutter speed to 1/50 sec. The three switches in the camera setup section can be set as indicated in table A to select one of the 8 speeds available.
Notes:
When using the high speed electronic shutter, the BLC switch must be set to the OFF position.
Using the high speed electronic shutter indoors with low lighting, will give darker pictures. In such a case,
add some lights to make sure the lighting is sufficient. If the lighting is very bright, pay attention to the light angle in order to avoid or minimize the smear phenomenon effect.
If IRIS is set to EI (electronic iris mode), then the high speed electronic shutter speed will not correspond
to the set speed.
Table A
1/50 sec.
1
1/120 sec.
2
1/250 sec.
3
1/500 sec.
4
1/1000 sec.
5
1/2000 sec.
6
1/4000 sec.
7
1/10000 sec.
8
123
123
123
123
123
123
123
123
10 English
Page 12
SETTINGS
Synchronisation (SYNC) setting
The internal synchronisation is set using the SYNC switch (4) in the camera setup section.
INT: Initial setting. The initial value cannot be changed. L-L: If the synchronisation setting is necessary, it can be entered in the adjustment sub-menu (see page 16).
The external synchronisation (VBS, VS) cannot be set in the camera setup section. When a VBS or VS sync
signal is entered at the camera VBS IN terminal, the camera will automatically detect the signal type and VBS or VS will be displayed on the on-screen menu. If necessary, the settings can then be entered in the adjustment sub-menu (see page 17).
Automatic Gain Control (AGC) setting
The automatic gain control can be turned ON or OFF using the AGC ON/OFF switch (6) in the camera setup section.
ON: Auto gain control function on (setting used under normal conditions) (see page 24).
GAMMA: ON (0.45), OFF (1) AGC GAIN: NORMAL (30 dB), HIGH (36 dB)
OFF: Fixed gain
Note:
When the AGC switch is set to OFF, the GAMMA and backlight compensation are automatically set to OFF, and the IRIS is set to AI.
LL
INT
VIDEO OUTVBS IN
ON
OFF
English 11
Page 13
White balance (WB) setting
Under normal conditions, the white balance is set to ATW (Auto Tracing White-Balance). However, depending on the camera installation location and conditions of use, the white balance mode can be set using the two WB switches (7 and 8) in the camera setup section (see table B).
ATW: Initial setting. The initial value cannot be changed.
LOCK: The white balance is done automatically while the AWB LOCK button is pressed, then it is locked
when the button is released.
PRESET: The white balance is done according to one of the three preset modes. The preset modes can
be adjusted manually in the adjustment sub-menu (see page 22).
MODE 1: Setting for incandescent lighting (2660 ˚K). MODE 2: Setting for indoors, fluorescent lighting (5100 ˚K). MODE 3: Can be set for outdoors, sunlight (5100 ˚K).
MANUAL: Set to the initial value. The value can be changed manually in the adjustment sub-menu (see
page 23).
Backlight compensation (BLC) setting
The backlight compensation ON/OFF is set using the BLC ON/OFF switch (9) in the camera setup section.
ON: Default setting, backlight compensation function on. However, depending on the camera installation
location and conditions of use, if the backlight compensation function need to be set, with the BLC switch set to ON, press the SET button to select one of PRESET (1, 2) or MANUAL (1, 2) modes indicated below.
PRESET 1 (Basic setting, see Fig. 1)
When the subject is dark and moving within the image, the brightness control is done independently for the 5 windows (W0-4). This setting is recommended when the subject will be moving across or within the image.
Table B
ATW
7 8
LOCK
7 8
PRESET
MANUAL
7 8
7 8
ON
OFF
W0=1
W2=10 W4=15 W3=10
W1=5
Fig. 1
AWB LOCK
12 English
Page 14
SETTINGS
PRESET 2 (Basic setting, see Fig. 2)
The windows are regrouped in 2 sections (W1 and 4; and W0, 2 and 3) and the lens iris is set automatically so that the backlight correction is optimum for the section composed of windows W 1 and 2. This setting is recommended when the subject will be centred in the image.
MANUAL 1 (or MANUAL 2) (Fig. 1, 3)
The size and position of window W4, and the windows (W0 - 4) distribution (WINDOW WEIGHTING) can be set manually to control a bigger area of the screen (e.g. when the subject will be moving in the screen area) and stored under one of the two manual settings.
OFF: Fixed backlight compensation
Notes:
The backlight compensation will operate when using an auto-iris lens (DC or VIDEO type).
If in the “MENU FOR ADJUSTMENT”, AGC is set to OFF, the backlight compensation will not operate.
Iris level setting
The iris is set using the IRIS AI (Auto-Iris)/EI (Electronic Iris) switch (10) in the camera setup section.
AI: Initial setting. When using a DC type auto-iris lens, the iris level settings can then be entered in the
adjustment sub-menu (see page 18).
EI: Electronic iris mode setting.
Note: If the AGC switch is set to OFF, setting the IRIS switch to EI will not set the electronic iris mode.
W0=0
W2=0 W4=15 W3=0
W1=15
Fig. 2
WINDOW WEIGHTING
W0 1 W1 1 W2 3 W3 3 W4(FIX) 15
PRESET OFF END MENU
Fig. 3
AI
EI
English 13
Page 15
USING THE ON-SCREEN MENUS
1 To display the menu
Press the SET button for about 3 seconds. The “MENU FOR ADJUSTMENT” is displayed.
2 To switch between menus and selection
When the setting of a switch in the camera setup section is changed, the corresponding sub-menu is displayed. To adjust the values or settings, press the CURSOR (d or c) button to select the desired value or setting, then press the SET button.
3 Initial values protection (WRITE PROTECT)
ON: Default setting. The initial values cannot be modified. OFF: Press the CURSOR (d or c) button to select OFF, then press the SET button. The write protection
is cancelled and the initial values can then be changed.
4 To exit the menu
Press the CURSOR (j or l) button to select END (get it flashing), then press the SET button.
5 To switch to the second page of the “MENU FOR ADJUSTMENT
Press the CURSOR (j or l) button to select NEXT PAGE (get it flashing), then press the SET button.
6 To switch back to the first page of the “MENU FOR ADJUSTMENT
Press the CURSOR (j or l) button to select PREVIOUS PAGE (get it flashing), then press the SET button.
7 To enter a camera ID (CAMERA ID)
(See page 25).
8 Aperture display (APERTURE)
(See page 27).
SET
(Menu 1)
MENU FOR ADJUSTMENT
SYNC INT IRIS AI BLC ON WHITE BALANCE ATW AGC ON SHUTTER 50
WRITE PROTECT ON
NEXT PAGE END
5
(Menu 2)
MENU FOR ADJUSTMENT
CAMERA ID OFF APERTURE
8
WRITE PROTECT ON
PREVIOUS PAGE END
6
CURSOR
(j, l, d or j)
2
3 4
7
SET
14 English
Page 16
MENU DISPLAY
b SYNC ADJUSTMENT
SW4: LL/INT
INT
MENU FOR ADJUSTMENT
SYNC INT IRIS AI BLC ON WHITE BALANCE ATW AGC ON SHUTTER 50
WRITE PROTECT ON
NEXT PAGE END
MENU FOR ADJUSTMENT
CAMERA ID ON APERTURE
WRITE PROTECT ON
PREVIOUS PAGE END
b IRIS ADJUSTMENT
SW10: AI/EI
AI
b BLC ADJUSTMENT
SW9: ON/OFF
ON
b WHITE BALANCE SETTING
SW7, 8: all ON
ATW
b AGC SETTING
SW6: ON/OFF
ON
b SHUTTER SETTING
SW1, 2, 3: all OFF 1/50 sec.
50
b CAMERA ID SETTING
CURSOR button: ON/OFF
ON
b APERTURE ADJUSTMENT
SET button: push
APERTURE
(insert VBS signal)
VBS
(insert VS signal)
VS L-L
EI
OFF
LOCK
(ON/OFF)
PRESET
(OFF/ON)
MANUAL
(all OFF)
OFF
(OFF/OFF/ON)
120
(OFF/ON/OFF)
250
(OFF/ON/ON)
500
(ON/OFF/OFF)
1000
OFF
ADJUSTMENT FOR AI
(IRIS LEVEL)
o------z------p 23
ADJUSTMENT FOR WB
WB PRESET MODE1
ADJUSTMENT FOR WB
(GAIN)
R o------z------p 86
B o------z------p 72
(ON/OFF/ON)
2000
(ON/ON/OFF)
4000
(ON/ON/ON)
10000
ADJUSTMENT FOR VBS
(PHASE)
H o------z------p 280
SC o------z------p 90
ADJUSTMENT FOR BLC
BLC MODE PRESET1
BLC LEVEL
ADJUSTMENT FOR BLC
(BLC LEVEL)
o------z------p 15
MODE2
MODE2
MODE3
MODE3
GAMMA ON
AGC GAIN NORMAL
CAMERA ID SETTING
CAMERA ID IS ??????
ADJUSTMENT FOR APERTURE
o------z------p 6
ADJUSTMENT FOR VS
(H SYNC PHASE)
o------z------p 280
(OFFSET)
R ------z------p 0
B o------z------p 255
(OFFSET)
R o------z------p 29
B o------z------p 189
(OFFSET)
R ------z------p 7
B o------z------p 255
ADJUSTMENT FOR L-L
(V SYNC PHASE)
o------z------p 518
ADJUSTMENT FOR BLC
PRESET2 MANUAL1 MANUAL2
GAMMA OFF
AGC GAIN NORMAL
CAMERA ID SETTING
ABCDEFGHIJKLM NOPQRSTUVWXYZ 0123456789:-p
MENU
CAMERA ID IS ??????
(SIZE)
ADJUSTMENT FOR BLC
(POSITION)
WINDOW WEIGHTING
W0 1 W1 1 W2 3 W3 3 W4(FIX) 15
HIGHHIGH
English 15
Page 17
ADJUSTMENTS
To enter settings or adjustments for the camera it must be connected to a monitor. The settings and adjustments are made by ways of on-screen displays.
SYNC
V sync phase adjustment
When using a camera switcher to connect 2 cameras or more to one monitor, there may be a vertical roll of the images when switched. In such a case, set as described below.
1 Press the CURSOR (j or l) button to select the WRITE PROTECT function setting, then press the
CURSOR (d or c) button to select OFF, then press the SET button.
2 Set the SYNC switch (4) to L-L.
The on-screen setting will automatically switch to L-L. Press the CURSOR (j or l) button to select the on-screen L-L setting (get it flashing), then press the SET button. The adjustment sub-menuADJUSTMENT FOR L-L” will be displayed.
3 Switch the display on the monitor from camera 1 to camera 2. Press the CURSOR (d or c) button until
the vertical sync phase is obtained. The on-screen marker (b) will move and the adjustment value will flash according to the vertical sync phase setting.
Note: When an adjustment is made, the PRESET setting will automatically switch to OFF. To return to the
initial value, just return the PRESET setting to ON, then press the SET button.
4 When finished.
1 Press the CURSOR (j or l) button to select END (get it flashing), then press the SET button to
return to the normal camera display, or
2 Press the CURSOR (j or l) button to select MENU (get it flashing), then press the SET button to
return to the “MENU FOR ADJUSTMENT” display.
LL
INT
MENU FOR ADJUSTMENT
SYNC L-L IRIS AI BLC OFF WHITE BALANCE ATW AGC ON SHUTTER 50
WRITE PROTECT OFF
NEXT PAGE END
ADJUSTMENT FOR L-L
(V SYNC PHASE)
o------z------p 415
PRESET OFF END MENU
CURSOR
SET
2
1
12
16 English
Page 18
ADJUSTMENTS
VBS phase adjustment
1 Press the CURSOR (j or l) button to select the WRITE PROTECT function setting, then press the
CURSOR (d or c) button to select OFF, then press the SET button.
2 Connect a VBS signal source to the VBS IN connector on the camera.
The on-screen setting will automatically switch to VBS. Press the CURSOR (j or l) button to select the on-screen VBS setting (get it flashing), then press the SET button. The adjustment sub-menuADJUSTMENT FOR VBS” will be displayed.
3 Press the CURSOR (d or c) button to adjust the horizontal phase (H). The on-screen marker (b) will
move and the adjustment value will flash according to the horizontal phase setting. When finished setting the horizontal phase (H), press the CURSOR (l) button to select the sub-carrier
(SC) phase.
4 Press the CURSOR (d or c) button to adjust the sub-carrier (SC) phase. The on-screen marker (b) will
move and the adjustment value will flash according to the sub-carrier phase setting.
Note: When an adjustment is made, the PRESET setting will automatically switch to OFF. To return to the
initial values, just return the PRESET setting to ON, then press the SET button.
5 When finished. (Refer to step 4 on page 16.)
Note: If using a VS sync signal, the H sync phase adjustment is made by following the same method as
described for the “VBS phase adjustment”.
English 17
CURSOR
SET
MENU FOR ADJUSTMENT
SYNC VBS IRIS AI BLC OFF
ADJUSTMENT FOR VBS
(PHASE)
H o------z------p 280
SC o------z------p 90
Page 19
IRIS
Auto-iris level adjustment
1 Press the CURSOR (j or l) button to select the WRITE PROTECT function setting, then press the
CURSOR (d or c) button to select OFF, then press the SET button.
2 Set the IRIS switch (10) to AI.
The on-screen setting will automatically switch to AI. Press the CURSOR (j or l) button to select the on-screen AI setting (get it flashing), then press the SET button. The adjustment sub-menuADJUSTMENT FOR AI” will be displayed.
3 Press the CURSOR (d or c) button until the desired iris level is obtained. The on-screen marker (b) will
move and the adjustment value will flash according to the iris level setting.
Note: When an adjustment is made, the PRESET setting will automatically switch to OFF. To return to the
initial value, just return the PRESET setting to ON, then press the SET button.
4 When finished.
(Refer to step 4 on page 16.)
Notes:
If IRIS is set to EI (electronic iris mode), the SHUTTER setting function will not operate.
When the AGC switch is set to OFF the IRIS cannot be set to EI.
AI
EI
MENU FOR ADJUSTMENT
SYNC INT IRIS AI BLC OFF
ADJUSTMENT FOR AI
(IRIS LEVEL)
o------z------p 26
PRESET OFF END MENU
Example:
When the image is dark, press the CURSOR (d or c) button to move the on-screen marker close to the position indicated above.
CURSOR
SET
18 English
Page 20
ADJUSTMENTS
BLC
Setting the light measuring area characteristics (size, position and distribution) for the MANUAL 1 setting
1 Press the CURSOR (j or l) button to select the WRITE PROTECT function setting, then press the
CURSOR (d or c) button to select OFF, then press the SET button.
2 Set the BLC switch (9) to ON. The on-screen setting for BLC will automatically switch to ON. Press the
CURSOR (j or l) button to select the on-screen ON setting (get it flashing), then press the SET button. The adjustment sub-menu “ADJUSTMENT FOR BLC” will be displayed.
ON
CURSOR
OFF
MENU FOR ADJUSTMENT
SYNC INT IRIS AI BLC ON
SET
3 Press the CURSOR (d or c) button until MANUAL 1 is selected, then press the SET button. The
adjustment sub-menu “SIZE” will be displayed.
4 Press the CURSOR buttons to set the size of the area, then press the SET button. The adjustment
sub-menu “POSITION” will be displayed.
CURSOR
CURSOR
ADJUSTMENT FOR BLC
(SIZE)
(p)
English 19
(o)
CURSOR
CURSOR
ADJUSTMENT FOR BLC
(SIZE)
(l)
(j)
SET
ADJUSTMENT FOR BLC
(POSITION)
ADJUSTMENT FOR BLC
BLC MODE PRESET1
ADJUSTMENT FOR BLC
BLC MODE MANUAL1
(SIZE)
Page 21
5 Press the CURSOR buttons to move (up, down, right, left) the area to the desired position, then press the
SET button. The adjustment sub-menu “WINDOW WEIGHTING” will be displayed.
Note: The WINDOW WEIGHTING default values are W0 : 1, W1 : 1, W2 : 3, W3 : 3, W4 : 15 (the value for
W4 is fixed to 15 and cannot be modified).
6 Press the CURSOR (j or l) button to select the desired window (get its value flashing), then press the
CURSOR (d or c) button to set the desired value (maximum 15) for each of the 4 windows 0, 1, 2 and
3.
Example: W0 : 5, W1 : 5, W2 : 10 and W3 : 10
WINDOW WEIGHTING
W0 5 W1 1 W2 3 W3 3 W4(FIX) 15
PRESET OFF END MENU
CURSOR
1_2_3_4_5
...
WINDOW WEIGHTING
W0 5 W1 5 W2 3 W3 3 W4(FIX) 15
PRESET OFF END MENU
CURSOR
CURSOR
3_4_5
...
WINDOW WEIGHTING
W0 5 W1 5 W2 10 W3 3 W4(FIX) 15
PRESET OFF END MENU
CURSOR
6_7_8_9_10
CURSOR
WINDOW WEIGHTING
W0 5 W1 5 W2 10 W3 10 W4(FIX) 15
PRESET OFF END MENU
...
CURSOR
CURSOR
8_9_10
...
Note: When an adjustment is made, the PRESET setting will automatically switch to OFF. To return to the
initial value, just return the PRESET setting to ON, then press the SET button.
7 When finished. (Refer to step 4 on page 16.)
(POSITION)
WINDOW WEIGHTING
W0 1 W1 1 W2 3 W3 3 W4(FIX) 15
PRESET OFF END MENU
20 English
Page 22
ADJUSTMENTS
BLC level adjustment for the PRESET 1 setting
1 Press the CURSOR (j or l) button to select the WRITE PROTECT function setting, then press the
CURSOR (d or c) button to select OFF, then press the SET button.
2 Set the BLC switch (9) to ON. The on-screen setting for BLC will automatically switch to ON. Press the
CURSOR (j or l) button to select the on-screen ON setting (get it flashing), then press the SET button. The adjustment sub-menu “ADJUSTMENT FOR BLC” will be displayed.
3 Press the CURSOR (d or c) button until PRESET 1 is selected. 4 Press the CURSOR (l) button to select BLC LEVEL (get it flashing), then press the SET button. The
adjustment sub-menu “BLC LEVEL” will be displayed.
5 While looking at the image on the monitor, press the CURSOR (d or c) button until the BLC level is
obtained. The on-screen marker (b) will move and the adjustment value will flash according to the BLC level setting.
Note: When an adjustment is made, the PRESET setting will automatically switch to OFF. To return to the
initial value, just return the PRESET setting to ON, then press the SET button.
6 When finished. (Refer to step 4 on page 16.)
Note: The BLC level adjustments should be entered under the PRESET 1 or MANUAL 1 settings. The BLC
level adjustments entered under the PRESET 2 or MANUAL 2 settings will not be effective.
ON
OFF
MENU FOR ADJUSTMENT
SYNC INT IRIS AI BLC ON
ADJUSTMENT FOR BLC
BLC MODE PRESET1
BLC MODE PRESET1
BLC LEVEL
(BLC LEVEL)
o------z------p 15
ADJUSTMENT FOR BLC
(BLC LEVEL)
o------z------p 20
CURSOR
SET
Example:
If the backlight compensation (BLC) correction is insufficient, press the CURSOR (d or c) button to move the on-screen marker close to the position indicated above.
English 21
Page 23
WHITE BALANCE
PRESET MODE 2 (indoors, fluorescent lighting) setting adjustment
1 Press the CURSOR (j or l) button to select the WRITE PROTECT function setting, then press the
CURSOR (d or c) button to select OFF, then press the SET button.
2 Set the WB switches to the PRESET mode (switch 7 to OFF and switch 8 to ON).
The on-screen setting for WHITE BALANCE will automatically switch to PRESET. Press the CURSOR (j or l) button to select the on-screen PRESET setting (get it flashing), then press the SET button. The
adjustment sub-menu “ADJUSTMENT FOR WB” will be displayed.
WB
7
8
MENU FOR ADJUSTMENT
SYNC INT IRIS AI BLC OFF WHITE BALANCE PRESET AGC ON
CURSOR
SET
3 Press the CURSOR (d or c) button until MODE 2 is selected, then press the SET button. The
adjustment sub-menu “OFFSET” will be displayed.
4 Press the CURSOR (d or c) button to adjust the R (red) offset. The on-screen marker (b) will move and
the adjustment value will flash according to the red offset setting. When finished setting the red offset, press the CURSOR (l) button to select B (blue). Press the CURSOR (d or c) button to adjust the B (blue) offset. The on-screen marker (b) will move
and the adjustment value will flash according to the blue offset setting.
Note: When an adjustment is made, the PRESET setting will automatically switch to OFF. To return to the
initial values, just return the PRESET setting to ON, then press the SET button.
5 When finished. (Refer to step 4 on page 16.)
Note: The OFFSET settings for MODE 1 and MODE 3 are made by following the same method as described
for MODE 2.
ADJUSTMENT FOR WB
WB PRESET MODE 1
WB PRESET MODE 2
ADJUSTMENT FOR WB
(OFFSET)
R o------z------p 29
B o------z------p189
PRESET OFF END MENU
22 English
Page 24
ADJUSTMENTS
MANUAL setting adjustment
1 Press the CURSOR (j or l) button to select the WRITE PROTECT function setting, then press the
CURSOR (d or c) button to select OFF, then press the SET button.
2 Set the WB switches to the MANUAL mode (both switches 7 and 8 to OFF).
The on-screen setting for WHITE BALANCE will automatically switch to MANUAL. Press the CURSOR (j or l) button to select the on-screen MANUAL setting (get it flashing), then press the SET button. The adjustment sub-menu “ADJUSTMENT FOR WB” will be displayed.
3 Press the CURSOR (d or c) button to adjust the R (red) gain. The on-screen marker (b) will move and
the adjustment value will flash according to the red gain setting. When finished setting the red gain, press the CURSOR (l) button to select B (blue). Press the CURSOR (d or c) button to adjust the B (blue) gain. The on-screen marker (b) will move and
the adjustment value will flash according to the blue gain setting.
Note: When an adjustment is made, the PRESET setting will automatically switch to OFF. To return to the
initial values, just return the PRESET setting to ON, then press the SET button.
4 When finished. (Refer to step 4 on page 16.)
WB
7
8
MENU FOR ADJUSTMENT
SYNC INT IRIS AI BLC OFF WHITE BALANCE MANUAL AGC ON
ADJUSTMENT FOR WB
(GAIN)
R o------z------p 86
B o------z------p 72
PRESET OFF END MENU
CURSOR
SET
English 23
Page 25
AGC
1 Press the CURSOR (j or l) button to select the WRITE PROTECT function setting, then press the
CURSOR (d or c) button to select OFF, then press the SET button.
2 Set the AGC switch (6) to ON.
The on-screen setting for AGC will automatically switch to ON. Press the CURSOR (j or l) button to select the on-screen ON setting (get it flashing), then press the SET button. The adjustment sub-menu will be displayed.
3 Setting the GAMMA
Press the CURSOR (d or c) button to select ON or OFF, according to the conditions described below. ON (0.45): For natural looking images. The image signal is compressed and this setting is recommended
under normal conditions.
OFF (1): The image signal is not compressed. This setting is recommended when processing the images.
When finished setting the gamma, press the CURSOR (l) button to select the AGC GAIN setting (get
it flashing).
4 Setting the AGC GAIN
Press the CURSOR (d or c) button to select NORMAL or HIGH, according to the conditions described below.
NORMAL: The AGC GAIN is set to 30 dB. When giving the priority to the image quality over the
illumination of the darkest part of the subject.
HIGH: The AGC GAIN is set to 36 dB. When giving the priority to the illumination of the darkest part of
the subject over the image quality.
Note: When an adjustment is made, the PRESET setting will automatically switch to OFF. To return to the
initial value, just return the PRESET setting to ON, then press the SET button.
5 When finished. (Refer to step 4 on page 16.)
ON
OFF
MENU FOR ADJUSTMENT
SYNC INT IRIS AI BLC OFF WHITE BALANCE ATW AGC ON
GAMMA ON
AGC GAIN NORMAL
GAMMA ON
AGC GAIN NORMAL
CURSOR
SET
24 English
Page 26
ADJUSTMENTS
CAMERA ID
1 Press the CURSOR (j or l) button to select the WRITE PROTECT function setting, then press the
CURSOR (d or c) button to select OFF, then press the SET button.
2 Press the CURSOR (j or l) button to select NEXT PAGE (get it flashing), then press the SET button.
The second page of the “MENU FOR ADJUSTMENT” will be displayed.
3 With the CAMERA ID ON setting flashing, press the SET button. The sub-menu “CAMERA ID SETTING”
will be displayed. The camera ID will be displayed. If no ID has been previously entered, ?????? will be displayed.
4 To change or enter a camera ID, press the SET button again. The input sub-menu “CAMERA ID
SETTING” will be displayed.
5 Example: To enter the camera ID S123AB
Press the CURSOR buttons to select the desired alphanumeric character or symbol (i.e. S), then press SET. The first ? or character in the camera ID will change to “S”.
Repeat the same method to enter the desired camera ID (maximum of 6 characters or symbols).
Note: The symbol c indicates a blank space. When entered in a camera ID, it will be displayed as a blank
space.
CURSOR
SET
SHUTTER 50
WRITE PROTECT ON
NEXT PAGE END
MENU FOR ADJUSTMENT
CAMERA ID ON APERTURE
CAMERA ID SETTING
CAMERA ID IS ??????
CAMERA ID SETTING
ABCDEFGHIJKLM NOPQRSTUVWXYZ 0123456789:-p
MENU
CAMERA ID IS ??????
English 25
Page 27
6 When finished entering the camera ID.
Press the CURSOR (d or c) button to select MENU (get it flashing), then press the SET button to return to the “MENU FOR ADJUSTMENT” display.
7 To correct the entered camera ID, repeat steps 2 to 6. 8 When finished.
Press the CURSOR (j or l) button to select END (get it flashing), then press the SET button to return to the normal camera display.
CAMERA ID SETTING
ABCDEFGHIJKLM NOPQRSTUVWXYZ 0123456789:-p
MENU
CAMERA ID IS S123AB
MENU FOR ADJUSTMENT
CAMERA ID ON APERTURE
WRITE PROTECT ON
PREVIOUS PAGE END
26 English
Page 28
ADJUSTMENTS
APERTURE
1 Press the CURSOR (j or l) button to select the WRITE PROTECT function setting, then press the
CURSOR (d or c) button to select OFF, then press the SET button.
2 Press the CURSOR (j or l) button to select NEXT PAGE (get it flashing), then press the SET button.
The second page of the “MENU FOR ADJUSTMENT” will be displayed.
3 Press the CURSOR (j or l) button to select APERTURE (get it flashing), then press the SET button. The
adjustment sub-menu “ADJUSTMENT FOR APERTURE” will be displayed.
4 Press the CURSOR (d or c) button to adjust the aperture setting (0 to 15 range). The on-screen marker
(b) will move and the adjustment value will flash according to the aperture setting. At this time the menu display will be cancelled, and you cannot return from this display to the menu
display. (This happens even if the PRESET setting is set to ON.) To return to the camera display, use the CURSOR buttons to select END (get it flashing), then press the SET button.
A higher setting value will give a sharp pictures, a lower setting value will give a soft pictures.
Note: When an adjustment is made, the PRESET setting will automatically switch to OFF. To return to the
initial values, just return the PRESET setting to ON, then press the SET button.
5 When finished. (Refer to step 4 on page 16.)
CURSOR
SET
SHUTTER 50
WRITE PROTECT OFF
NEXT PAGE END
MENU FOR ADJUSTMENT
CAMERA ID ON APERTURE
ADJUSTMENT FOR APERTURE
o------z------p 6
ADJUSTMENT FOR APERTURE
o------z------p 9
PRESET OFF END
English 27
Page 29
TROUBLESHOOTING
Before taking the camera for repairs, please check below to make sure that the camera is used correctly. If it still does not perform correctly, please consult your dealer or a Sanyo Authorized Service Centre.
No picture on the monitor screen
Is the power turned on to all connected devices? Is the voltage correct?
Are all the signal connecting cables correctly connected?
Is the lighting sufficient?
Has the lens cap been removed?
Is the lens type (DC or VIDEO) correctly selected?
Depending on the type of lens, the A. I. LENS switch must be set accordingly.
Is the iris control correctly set?
A: When using a DC type lens, the CORSOR button should be adjusted. B: When using a VIDEO type lens, the LEVEL volume (on the lens) should be adjusted.
The picture is not clear
Is the monitor correctly adjusted?
Is the flange-back position correctly set?
Is the lens focus correctly adjusted?
Are the lens surfaces clean?
If there is dust or finger prints on the lens, the image quality will deteriorate. To clean the lens use a soft cloth or a commercially available lens cleaning set.
SERVICE
This camera is a precision instruments and if treated with care, will provide years of satisfactory performance. However, in the event of a problem, the owner is advised not to attempt to make repairs or open the cabinet. Servicing should always be referred to your dealer or Sanyo Authorized Service Centre.
28 English
Page 30
SPECIFICATIONS
Camera:
Scaning system : PAL colour TV system (625 TV lines, 50
Interlace : 2:1 interlace Image device : 1/3 inch solid state image device CCD Picture elements : 795 (H) x 596 (V) Effective picture elements : 752 (H) x 582 (V) Synchronizing system : Internal sync, Line lock manually
External sync : VBS or VS signal (Genlock, Automatic
Resolution : 460 TV lines horizontally, 350 TV lines
Video output level : 1.0 Vp-p/75 ohms, composite Video S/N ratio : More than 48 dB (AGC switch ON:
Minimum required illumination (incandescent lighting)
Backlight compensation : Manual ON/OFF switching, Active-zone
Iris function : Manual Electric iris (EI)/Auto iris (AI)
Electronic iris range : 2 lux to 100,000 lux (F 1.2, lens)
field/sec.)
switchable/External sync
switching)
vertically
Normal), More than 50 dB (AGC switch OFF)
: Approx. 2 lux with a F 1.2 lens (AGC
ON: Gain Normal, 50 IRE), Approx. 0.9 lux with a F 1.2 lens (AGC ON: Gain High, 50 IRE)
light measuring system (Active when using an auto-iris lens)
switching
2.7 lux to 130,000 lux (F 1.4, lens)
Electronic shutter : 8 speeds, selectable by switches:
(1/50, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000 sec.)
Flange-back : 12.5 mm ± 0.5 mm White balance : ATW/AWB LOCK/PRESET/MANUAL
switching
Gain control : Manual ON (Normal: 30 dB, Hi: 36
dB)/OFF switching
Gamma correction : Manual ON (γ = 0.45)/OFF (1) switching Lens mount : CS mount (or C mount with the
supplied adaptor)
Environmental conditions : Temperature: –10˚C ~ +50˚C
Humidity: less than 90% (no condensation)
Power supply : AC 24 V ± 4 V, 50 Hz (using a
commercially available AC adaptor
Power consumption : Approx. 3.5 W Weight : Approx. 330 g (without lens)
English 29
Page 31
Dimensions: mm
108.5
99.51.5
45
11
12
22
Features and specifications are subject to change without prior notice or obligations.
1/4”–20 UNC
56
28
30 English
Page 32
1AC6P1P1698-­L53P4/XE(0398NI)
SANYO Electric Co., Ltd.
Printed in Japan
Loading...