Sanyo UR18650E, UR18650A, UR18650U User Manual

Product name: Lithium Ion Battery Cell Reference number: SDS-IBT-00010
Establishment / Revision: Dec.1 2008
Safety data sheet for chemical products (SDS)
1. PRODUCT AND COMPANY IDENTIFICATION
!Product name: Lithium Ion Battery Cell !Product code: Cylindrical type cell
!Company name: Sanyo Electric Co., Ltd. Mobile Energy Company !Address: 222-1 , Kaminaizen, Sumoto City, Hyogo, Japan !Telephone number: +81-799-24-4111 !Fax number: +81-799-24-4121 !Emergency telephone number: [Weekday] +81-799-23-3942
[Night and holiday] +81-799-24-4131
2. COMPOSITION / INFORMATION ON INGREDIENTS
!Substance or preparation: Preparation !Information about the chemical nature of product:
Common chemical name /
General name
CAS number Concentration /
Concentration range
Classification and
hazard labeling
Lithium metal oxidate (Li(Mn-Co-Ni)O2)
- 20-40% -
Iron 7439-89-6 15-25% ­Aluminum 7429-90-5 2-6% ­Graphite (Natural graphite) (Artificial graphite)
7782-42-5 7740-44-0
10-20% -
Copper 7440-50-8 5-15% Sensitization of the skin
group No.2
Organic electrolyte - 10-20% Inflammable liquid
3. HAZARDS IDENTIFICATION For the battery cell, chemical materials are stored in a hermetically sealed metal case, designed to withstand
temperatures and pressures encountered during normal use. As a result, during normal use, there is no physical danger of ignition or explosion and chemical danger of hazardous materials' leakage.
However, if exposed to a fire, added mechanical shocks, decomposed, added electric stress by miss-use,
the gas release vent will be operated. The battery cell case will be breached at the extreme, hazardous materials may be released.
Moreover, if heated strongly by the surrounding fire, acrid gas may be emitted.
!Most important hazard and effects
Human health effects:
Inhalation: The steam of the electrolyte has an anesthesia action and stimulates a respiratory tract. Skin contact: The steam of the electrolyte stimulates a skin. The electrolyte skin contact causes a sore and stimulation on the skin. Eye contact: The steam of the electrolyte stimulates eyes. The electrolyte eye contact causes a sore and stimulation on the eye. Especially, substance that causes a strong inflammation of the eyes is
contained. Environmental effects: Since a battery cell remains in the environment, do not throw out it into the environment.
!Specific hazards:
If the electrolyte contacts with water, it will generate detrimental hydrogen fluoride. Since the leaked electrolyte is inflammable liquid, do not bring close to fire.
Product name: Lithium Ion Battery Cell Reference number: SDS-IBT-00010
Establishment / Revision: Dec.1 2008
4. FIRST-AID MEASURES
Spilled internal cell materials
!Inhalation:
Make the victim blow his/her nose, gargle. Seek medical attention if necessary.
!Skin contact:
Remove contaminated clothes and shoes immediately. Wash extraneous matter or contact region with
soap and plenty of water immediately.
!Eye contact:
Do not rub one’s eyes. Immediately flush eyes with water continuously for at least 15 minutes. Seek
medical attention immediately.
A battery cell and spilled internal cell materials
!Ingestion:
Make the victim vomit. When it is impossible or the feeling is not well after vomiting, seek medical
attention.
5. FIRE-FIGHTING MEASURE !Suitable extinguishing media: Plenty of water, carbon dioxide gas, nitrogen gas, chemical powder fire
extinguishing medium and fire foam.
!Specific hazards: Corrosive gas may be emitted during fire. !Specific methods of fire-fighting: When the battery burns with other combustibles simultaneously, take fire-
extinguishing method which correspond to the combustibles. Extinguish a fire from the windward as much as possible.
!Special protective equipment for firefighters:
Respiratory protection: Respiratory equipment of a gas cylinder style or protection-against-dust mask Hand protection: Protective gloves Eye protection: Goggle or protective glasses designed to protect against liquid splashes Skin and body protection: Protective cloth
6. ACCIDENTAL RELEASE MEASURES Spilled internal cell materials, such as electrolyte leaked from a battery cell, are carefully dealt with
according to the followings.
!Precautions for human body:
Remove spilled materials with protective equipment (protective glasses and protective gloves). Do not
inhale the gas as much as possible. Moreover, avoid touching with as much as possible.
!Environmental precautions: Do not throw out into the environment. !Method of cleaning up: The spilled solids are put into a container. The leaked place is wiped off with dry
cloth.
!Prevention of secondary hazards: Avoid re-scattering. Do not bring the collected materials close to fire.
7. HANDLING AND STORAGE !Handling
Technical measures:
Prevention of user exposure: Not necessary under normal use.
Prevention of fire and explosion: Not necessary under normal use. Precaution for safe handling: Do not damage or remove the external tube. Specific safe handling advice: Never throw out cells in a fire or expose to high temperatures. Do not soak cells in water or seawater. Do not expose to strong oxdizers. Do not give a strong mechanical shock or fling. Never disassemble, modify or deform. Do not connect the positive terminal to the negative terminal with electrically conductive material. In the case of charging, use only dedicated charger or charge according to the conditions specified by Sanyo.
!Storage
Technical measures:
Storage conditions (suitable, to be avoided): Avoid direct sunlight, high temperature, high humidity.
Store in cool place (temperature: -20 ~ 35 degree C, humidity: 45 ~ 85%).
Incompatible products: Conductive materials, water, seawater, strong oxidizers and strong acids
Packing material (recommended, not suitable): Insulative and tear proof materials are recommended.