Sanyo TravelMate P245-M, TravelMate P245-MG, 3UR18650-2-T0950 User Manual

Page 1
Page 2
Page 3
Page 4
Page 5
UN Test Data (Model:3UR18650-2-T0590)
1.Test Item: Altitude simulation (T1) P.3/10
2.Test Purpose: This test simulates air transport under low-pressure conditions.
3.Test Procedure:
Test cells and batteries shall be stored at a pressure of 11.6kPa or less for at least six hours at ambient temperature(20±5).
As above.
4.Test Requirements:
No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage retention is not less than 90%. The requirement relating to voltage is not applicable to test batteries at fully discharged states.
5.Test Date: 2007/10/11
6.Test Data
Before tes
t
After test Before testAfter test
1 294.50 294.50 0.000 12.55 12.52 99.8
0
PASS
2 293.74 293.71 0.010 12.54 12.52 99.8
0
PASS
3 294.34 294.30 0.014 12.55 12.52 99.8
0
PASS
4 294.02 294.02 0.000 12.55 12.52 99.8
0
PASS
5 294.69 294.67 0.007
0
PASS
6 294.80 294.79 0.003
0
PASS
7 294.79 294.76 0.010
0
PASS
8 294.49 294.50 0.003
0
PASS
9 294.13 294.13 0.000 12.56 12.55 99.9
0
PASS
10 294.68 294.68 0.000 12.56 12.55 99.9
0
PASS
11 294.68 294.67 0.003 12.56 12.56 100.0
0
PASS
12 294.05 294.05 0.000 12.56 12.56 100.0
0
PASS
13 294.55 294.55 0.000
0
PASS
14 294.59 294.60 0.003
0
PASS
15 294.12 294.12 0.000
0
PASS
16 294.41 294.38 0.010
0
PASS
Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire
Voltage(V)
Vol
tage Retention( %
)(
=>90%
)
Other event
Result Judgement
At first
cycle,in
fully
charged
states
PASS
At first
cycle,in
fully
discharged
states
A
fter 50
cycles
ending in
fully
charged
states
A
fter 50
cycles
ending in
fully
discharged
states
Battery No.
Mass(g)
M
ass
loss (%)
(
=<0.1%
)
Page 6
UN Test Data (Model:3UR18650-2-T0590)
1.Test Item: Thermal Test (T2) P.4/10
2.Test Purpose: This test assesses cell and battery seal integrity and internal electrical connections. The test
is conducted using rapid and extreme temperature changes.
3.Test Procedure:
Test cells and batteries are to be stored for at least six hours at a test temperature equal to 75±2 , followed by storage for at least six hours at a test temperature equal to -40±2
.The maximum time internal between
test temperature extremes is 30 minutes.This procedure is to be repeated 10 times, after which all test cells and batteries are to be stored for 24 hours at ambient temperature (20 ±5
). For large cells and batteries the
duration of exposure to the test temperature extremes should be at least 12 hours.
As above.
4.Test Requirements:
No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage retention is not less than 90%. The requirement relating to voltage is not applicable to test batteries at fully discharged states.
5.Test Date: 2007/10/17
6.Test Data
Before tes
t
After test Before testAfter test
1 294.50 294.43 0.024 12.52 12.36 98.7
0
PASS
2 293.71 293.65 0.020 12.52 12.36 98.7
0
PASS
3 294.30 294.27 0.010 12.52 12.36 98.7
0
PASS
4 294.02 293.91 0.037 12.52 12.35 98.6
0
PASS
5 294.67 294.60 0.024
0
PASS
6 294.79 294.71 0.027
0
PASS
7 294.76 294.70 0.020
0
PASS
8 294.50 294.43 0.024
0
PASS
9 294.13 294.08 0.017 12.55 12.40 98.8
0
PASS
10 294.68 294.65 0.010 12.55 12.40 98.8
0
PASS
11 294.67 294.63 0.014 12.56 12.40 98.7
0
PASS
12 294.05 294.01 0.014 12.56 12.40 98.7
0
PASS
13 294.55 294.50 0.017
0
PASS
14 294.60 294.56 0.014
0
PASS
15 294.12 294.10 0.007
0
PASS
16 294.38 294.32 0.020
0
PASS
Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire
Voltage(V)
Vol
tage Retention( %
)(
=>90%
)
Other event
Result
Judgement
At first
cycle,in
fully
charged
states
PASS
At first
cycle,in
fully
discharged
states
A
fter 50
cycles
ending in
fully
charged
states
A
fter 50
cycles
ending in
fully
discharged
states
Battery No.
Mass(g)
M
ass
loss (%)
(
=<0.1%
)
Page 7
UN Test Data (Model:3UR18650-2-T0590)
1.Test Item: Vibration (T3) P.5/10
2.Test Purpose: This test simulates vibration during transport.
3.Test Procedure:
Cells and batteries are firmly secured to the platform of the vibration machine without distorting the cells in such a manner as to faithfully transmit the vibration. The vibration shall be a sinusoidal waveform with a logarithmic sweep between 7 Hz and 200 Hz and back to 7 Hz traversed in 15 minutes.This cycle shall be repeated 12 times for a total of 3 hours for each of three mutually perpendicular mounting positions of the cell. One of the directions of vibration must be perpendicular to the terminal face. The logarithmic frequency sweep is as follows: from 7 Hz a peak acceleration of 1gn is maintained until 18 Hz is reached. The amplitude is then maintained at 0.8 mm(1.6 mm total excursion) and thefrequency increased until a peak acceleration of 8gn occurs (approximately 50Hz).A peak acceleration of 8 gn is then maintained until the frequency is increased to 200Hz.
As above.
4.Test Requirements:
No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage retention is not less than 90%. The requirement relating to voltage is not applicable to test batteries at fully discharged states.
5.Test Date: 2007/10/19
6.Test Data
Before tes
t
After test Before testAfter test
1 294.43 294.49 0.020 12.36 12.35 99.9
0
PASS
2 293.65 293.69 0.014 12.36 12.35 99.9
0
PASS
3 294.27 294.31 0.014 12.36 12.35 99.9
0
PASS
4 293.91 293.99 0.027 12.35 12.34 99.9
0
PASS
5 294.60 294.63 0.010
0
PASS
6 294.71 294.73 0.007
0
PASS
7 294.70 294.72 0.007
0
PASS
8 294.43 294.43 0.000
0
PASS
9 294.08 294.07 0.003 12.40 12.39 99.9
0
PASS
10 294.65 294.61 0.014 12.40 12.39 99.9
0
PASS
11 294.63 294.63 0.000 12.40 12.39 99.9
0
PASS
12 294.01 294.00 0.003 12.40 12.38 99.8
0
PASS
13 294.50 294.50 0.000
0
PASS
14 294.56 294.54 0.007
0
PASS
15 294.10 294.07 0.010
0
PASS
16 294.32 294.32 0.000
0
PASS
Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire
Voltage(V)
Vol
tage Retention( %
)(
=>90%
)
Other event
Result
Judgement
At first
cycle,in
fully
charged
states
PASS
At first
cycle,in
fully
discharged
states
A
fter 50
cycles
ending in
fully
charged
states
A
fter 50
cycles
ending in
fully
discharged
states
Battery No.
Mass(g)
M
ass
loss (%)
(
=<0.1%
)
Page 8
UN Test Data (Model:3UR18650-2-T0590)
1.Test Item: Shock (T4) P.6/10
2.Test Purpose: This test simulates possible impacts during transport.
3.Test Procedure:
Test cells and batteries shall be secured to the testing machine by means of a rigid mount which will support all mounting surfaces of each test battery. Each cell or battery shall be subjected to a half-sine shock of pack acceleration of 150 g
n
and pulse duration of 6 milliseconds. Each cell or battery shall be subjected to three shocks in the positive direction followed by three shocks in the negative direction of three mutually perpendicular mounting positions of the cell or battery for a total of 18 shocks. However, large cells and large batteries shall be subjected to a half-sine shock of peak acceleration of 50 g
n
and pulse duration of 11 milliseconds. Each cell or battery is subjected to three shocks in the positive direction followed by three shocks in the negative direction of each of three mutually perpendicular mounting positions of the cell for a total of 18 shocks.
As above.
4.Test Requirements:
No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage retention is not less than 90%. The requirement relating to voltage is not applicable to test batteries at fully discharged states.
5.Test Date: 2007/10/23
6.Test Data
Before tes
t
After test Before testAfter test
1 294.49 294.45 0.014 12.35 12.35 100.0
0
PASS
2 293.69 293.67 0.007 12.35 12.34 99.9
0
PASS
3 294.31 294.30 0.003 12.35 12.34 99.9
0
PASS
4 293.99 293.99 0.000 12.34 12.33 99.9
0
PASS
5 294.63 294.61 0.007
0
PASS
6 294.73 294.76 0.010
0
PASS
7 294.72 294.77 0.017
0
PASS
8 294.43 294.48 0.017
0
PASS
9 294.07 294.08 0.003 12.39 12.39 100.0
0
PASS
10 294.61 294.64 0.010 12.39 12.39 100.0
0
PASS
11 294.63 294.65 0.007 12.39 12.39 100.0
0
PASS
12 294.00 294.04 0.014 12.38 12.39 100.1
0
PASS
13 294.50 294.52 0.007
0
PASS
14 294.54 294.59 0.017
0
PASS
15 294.07 294.08 0.003
0
PASS
16 294.32 294.34 0.007
0
PASS
Notes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire
Voltage(V)
Vol
tage Retention( %
)(
=>90%
)
Other event
Result
Judgement
At first
cycle,in
fully
charged
states
PASS
At first
cycle,in
fully
discharged
states
A
fter 50
cycles
ending in
fully
charged
states
A
fter 50
cycles
ending in
fully
discharged
states
Battery No.
Mass(g)
M
ass
loss (%)
(
=<0.1%
)
Page 9
UN Test Data (Model:3UR18650-2-T0590)
1.Test Item: External short circuit (T5) P.7/10
2.Test Purpose: This test simulates an external short circuit.
3.Test Procedure:
The cell or battery to be tested shall be temperature stabilized so that its external case temperature reaches 55±2 and then the cell or battery shall be subjected to a short circuit condition with a total external resistance of less than 0.1ohm at 55±2.This short circuit condition is continued for at least one hour after the cell or battery external case temperature has returned to 55±2. The cell or battery must be observed for a further six hours for the test to be concluded.
As above.
4.Test Requirements:
External temperature of test batteries does not exceed 170 and there is no disassembly,no rupture and no fire within six hours of this test.
5.Test Date: 2007/10/25
6.Test Data
1 0 PASS 2 0 PASS 3 0 PASS 4 0 PASS 5 0 PASS 6 0 PASS 7 0 PASS 8 0 PASS
9 0 PASS 10 0 PASS 11 0 PASS 12 0 PASS 13 0 PASS 14 0 PASS 15 0 PASS 16 0 PASS
Notes: D-Disassembly, R-Rupture, F-Fire, 0-No disassembly, no rupture & no fire
JudgementBattery No.
Maximum temperature (°C)
Other event
Result
At first
cycle,in
fully
charged
states
55.0
PASS
55.2
55.0
54.9
At first
cycle,in
fully
discharged
states
54.7
54.7
54.6
55.4
A
fter 50
cycles
ending in
fully
charged
states
55.0
55.1
55.5
55.3
A
fter 50
cycles
ending in
fully
discharged
states
54.7
54.8
54.7
54.9
Page 10
UN Test Data (Model:3UR18650-2-T0590)
1.Test Item:Impact (T6) P.8/10
2.Test Purpose: This test simulates an impact.
3.Test Procedure:
The test sample cell or component cell is to be placed on a flat surface. A 15.8mm diameter bar is to be placed across the center of the sample. A 9.1kg mass is to be dropped from a height of 61±2.5cm onto the sample.
A cylindrical or prismatic cell is to be impacted with its longitudinal axis parallel to the flat surface and perpendicular to the longitudinal axis of the 15.8mm diameter curved surface lying across the center of the test sample. A prismatic cell is also to be rotated 90 degrees around its longitudinal axis so that both the wide and narrow sides will be subjected to the impact. Each sample is to be subjected to only a single impact. Separate samples are to be used for each impact.
A coin or button cell is to be impacted with the flat surface of the sample parallel to the flat surface and the 15.8mm diameter curved surface lying across its center.
As above.
4.Test Requirements:
External temperature of test batteries does not exceed 170°C and there is no disassembly and no fire within six hours of this test.
5.Test Date: 2007/10/05
6.Test Data:
1
0
PASS
2
0
PASS
3
0
PASS
4
0
PASS
5
0
PASS 6 PASS 7 PASS 8 PASS PASS 9 PASS
10 PASS 11
0
PASS
12
0
PASS
13
0
PASS
14
0
PASS
15
0
PASS
16 PASS 17 PASS 18 PASS 19 PASS 20 PASS
Notes: D-Disassembly, F-Fire, 0-No disassembly & no fire
Other event
Result JudgementCell No. Maximum Temperature(°C)
At first
cycle, 50%
charged
states
119 116 122 122 122
After 50
cycles
ending, in
fully
discharged
states
54 53 58 50 52
Page 11
UN Test Data (Model:3UR18650-2-T0590)
1.Test Item:Overcharge (T7) P.9/10
2.Test Purpose: This test evaluates the ability of a rechargeable battery to withstand an overcharge condition.
3.Test Procedure:
The charge current shall be twice the manufacturer’s recommended maximum continuous charge current. The minimum voltage of the test shall be as follows:
(a) when the manufacturer’s recommended charge voltage is not more than 18V,the minimum voltage of the test shall be the lesser of two times the maximum charge voltage of the battery or 22V.
(b) when the manufacturer’s recommended charge voltage is more than 18V, the minimum voltage of the test shall be 1.2 times the maximum charge voltage.
Tests are to be conducted at ambient temperature. The duration of the test shall be 24 hours.
Min.Charge Voltage: 22 V Charge Current: 6.44 A
4.Test Requirements:
There is no disassembly and no fire within seven days of the test.
5.Test Date: 2007/10/10
6.Test Data Result Jud
g
ement
1 PASS 2 PASS 3 PASS 4 PASS 5 PASS 6 PASS 7 PASS 8 PASS
Notes: D-Disassembly, F-Fire, 0-No disassembly & no fire
Battery No. Event
At first cycle
in fully
charged
states
0
After 50
cycles
ending in
fully charged
states
0 0 0 0
PASS
0 0 0
Page 12
1.Test Item: Drop Test P.10/10
2.Test Purpose: This test simulates the drop of the packaging during transport.
3.Test Procedure:
Number of Test Samples (Per design type, Manufacturer ) and Drop Orientation For other than flat drops the centre of gravity must be vertically over the point of impact. Where more than one orientation is possible for a given drops, the orientation most likely to result in failure of the packaging must be used.
Five (one for each drop) First drop: flat on the bottom
Second drop: flat on the top Third drop: flat on the long side Fourth drop: flat on the short side Fifth drop: on a corner
SANYO Internal Procedure:
Packaging: Fiberboard boxes. Number of test samples: Five(one for each drop). It may do the drop of five orientations with one sample if the packing does not have the big damage. Drop orientation: As above.
4.Test Requirements:
A Package passes the test if it meets the following criteria: Each package is capable of withstanding a 1.2 meter drop test in any orientation without damage to cells
cell) contact and without release of contents.
5.Test Date: 2009/11/18
6.Test Data: PASS(Drop height 1.2m)
6-1. No any package crack 6-2. No any cell damege and battery damage. 6-3. No any out side release of contents from shipping box 6-4. No any contact between battery and battery, cell and cell.
Packaging size:
150*350*555mm Packaging weight (before):
9.0kg Packaging weight (after):
9.0kg
samples Boxes of natural wood Plywood boxes
Composite Packagings
UN Test Data (Model:3UR18650-2-T0590)
Reconstituted wood boxes
or batteries contained therein, without shifting of the contents so as to allow battery to battery (or cell to
Fibreboard boxes Plastic boxes Steel or aluminum boxes
which are in the shape of a box.
Drop orientationPackaging Number of test
SANYO confidential Copyright (c) 2008, Sanyo Electric Co., Ltd.
Loading...