Ordering number: EN1651B
±
θ
°
°
°
−
°
±
8
Thick Film Hybrid IC
STK4191 V
AF Power Amplifier (Split Power Supply)
(50W + 50W min, THD = 0.08%)
Features
• Built-in muting circuit to cut off various kinds of pop
Package Dimensions
unit: mm
noise.
• Greatly reduced heat sink due to substrate temperature
125 ° C guaranteed.
4040
[STK4191 V ]
• Distortion 0.08% due to current mirror circuit.
• Pin-compatible with the STK4101II series. The
STK4101V series use the same package and are available for output 6W to 50W.
• Excellent cost performance.
Specifications
Maximum Ratings
Parameter Symbol Conditions Ratings Unit
Maximum supply voltage V
Thermal resistance
Junction temperature Tjmax 150
Operating substrate temperature Tc 125
Storage temperature Tstg
Available time for load short-circuit t
at Ta = 25 ° C
max
CC
j-c 1.8
30 to +125
V
s
= ± 35.5V, R
CC
= 8 Ω , f = 50Hz, P
L
= 50W 2 s
O
53 V
C/W
C
C
C
Recommended Operating Conditions
Parameter Symbol Conditions Ratings Unit
Recommended supply voltage V
Load resistance R
CC
L
SANYO Electric Co., Ltd. Semiconductor Business Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
at Ta = 25 ° C
35.5 V
Ω
61197HA (ID) / 8298MO / 4085KI No. 1651—1/5
STK4191 V
Operating Characteristics
at Ta = 25 ° C, V
= ± 35.5V, R
CC
= 8 Ω (non-inductive), Rg = 600 Ω , VG = 40 dB unless
L
otherwise specified, at specified test circuit (based on sample application circuit)
Parameter Symbol Conditions min typ max Unit
Quiescent current I
P
CCO
(1)
O
Output power
(2)
P
O
Total harmonic distortion THD f = 1kHz, Po = 1W 0.08 %
Frequency response f
Input impedance r
Output noise voltage V
Neutral voltage V
Muting voltage V
, f
L
H
i
NO
N
M
Note : For Power supply at the time of test, use a constant-voltage power supply
unless otherwise specified.
* For measurement of the availab le time f or load short-circuit and output noise
voltage, use the specified transformer power supply shown right.
** The output noise voltage is represented by the peak value on rms scale
(VTVM) of average value indicating type. For AC power supply, use an AC
stabilized power supply (50Hz) to eliminate the effect of flicker noise in AC
primary line.
V
= ± 42.5V 20 40 100 mA
CC
f = 20Hz to 20kHz,
THD = 0.08%
V
= ± 32V, f = 1kHz,
CC
THD = 0.2%, R
P
= 1W, dB 20 to 50k Hz
O
f = 1kHz, P
V
= ± 42.5V, Rg = 10k Ω
CC
V
= ± 42.5V -70 0 +70 mV
CC
= 4 Ω
L
+0
−
3
= 1W 55 k Ω
O
50 W
55 W
1.2 mVrms
-2 -5 -10 V
Specified transformer power supply
(Equivalent to MG-200)
Equivalent Circuit
No. 1651—2/5