No. 4340-2/9
STK400-050
Specifications
Maximum Ratings at Ta = 25°C
Notes
• Use rated power supply for test unless otherwise specified.
• When measuring available time for load short-circuit and output noise voltage use transformer power supply indicated
below.
• Output noise voltage is represented by the peak value rms (VTVM) for mean reading. Use an AC stabilized power
supply (50 Hz) on the primary side to eliminate the effect of AC flicker noise.
Internal Equivalent Circuit
Specified Transformer Power Supply
(RP-25 Equivalent)
Parameter Symbol Conditions Ratings Unit
Maximum supply voltage V
CC
max ±39 V
Thermal resistance
θj-c Per power transistor 1.8 °C/W
Junction temperature Tj 150 °C
Operating substrate temperature Tc 125 °C
Storage temperature range Tstg –30 to +125 °C
Available time for load short-circuit t
s
V
CC
= ±26 V, RL = 6 Ω, f = 50 Hz, PO = 30 W 1 s
Parameter Symbol Conditions
Ratings
Unit
min typ max
Quiescent current I
CCO
VCC=± 31 V 30 90 150 mA
Output power
P
O
(1) VCC= ±26 V, f = 20 Hz to 20 kHz, THD = 0.4% 30 35 W
P
O
(2) VCC= ±22 V, f = 1 kHz, THD = 1.0%, RL= 3 Ω 30 35 W
Total harmonic distortion
THD (1) V
CC
= ±26 V, f = 20 Hz to 20 kHz, PO= 1.0 W 0.4 %
THD (2) V
CC
= ±26 V, f = 1 kHz, PO= 5.0 W 0.01 %
Frequency response f
L
, fHVCC= ±26 V, PO= 1.0 W, dB
20 to 50 k
Hz
Input impedance r
i
VCC= ±26 V, f = 1 kHz, PO= 1.0 W 55 kΩ
Output noise voltage V
NO
VCC= ±31 V, Rg = 10 kΩ 1.2 mVrms
Neutral voltage V
N
VCC= ±31 V –70 0 +70 mV
+0
–3
Operating Characteristics at Ta = 25°C, RL= 6Ω, Rg = 600Ω, VG = 40dB, RL(non-inductive)