SANYO PLC-XU32-33-37-38 Service Manual

PRODUCT CODE
(MK8A) 1 122 138 00 (PK8A) 1 122 139 00 (PK8C) 1 122 139 02 (MK8G) 1 122 138 06 (PK8G) 1 122 139 06 (PK8J) 1 122 139 08
REFERENCE NO. SM5110365
Chassis No. MK8-XU3200
MK8-XU3700 MH8-XU3300 MH8-XU3800
NOTE: Match the Chassis No. on the unit’s
back cover with the Chassis No. in the Service Manual.
Literature is required.You must refer to “Notices” to the Original Service Manual prior to servicing the unit.
Multimedia Projector
SERVICE MANUAL
FILE NO.
Model No. PLC-XU32
PLC-XU33 PLC-XU37 PLC-XU38
U.S.A., Canada, Europe, Asia, Africa U.K
Original Version
PLC-XU33 PLC-XU38
PLC-XU32 PLC-XU37
(MH8A) 1 122 134 00 (PH8A) 1 122 135 00 (PH8C) 1 122 135 02 (MH8G) 1 122 134 06 (PH8G) 1 122 135 06 (PH8J) 1 122 135 08
-2-
Contents
Safety instructions ________________________________________________3
Specifications __________________________________________________ 4
Adjustments after parts replacement ________________________________ 5
Circuit protections ______________________________________________ 6-7
Fuse ____________________________________________________ 6
Thermal switch ____________________________________________ 6
Interlock switch ____________________________________________ 6
Warning temperature and power failure protection ________________ 7
Mechanical disassemblies ______________________________________ 8-13
Optical parts disassemblies ____________________________________ 14-17
LCD panel/prism ass’y replacement ________________________________ 19
Lamp replacement ______________________________________________ 20
Optical adjustments __________________________________________ 21-24
Contrast adjustment ________________________________________ 21
Condenser lens adjustment __________________________________ 22
Condenser lens-Out adjustment ______________________________ 23
Relay lens-Out adjustment __________________________________ 24
Electric adjustments __________________________________________ 25-30
Service adjustment menu operation ____________________________ 23
Circuit adjustments ______________________________________ 24-29
Service adjustment data table ______________________________ 30-33
Test points and locations ____________________________________ 34
Troubleshooting ______________________________________________ 35-39
No power ______________________________________________ 35-36
No picture ____________________________________________ 37-38
No sound ________________________________________________ 39
Lens motor problems ______________________________________ 39
Control port functions ________________________________________ 40-43
Waveforms __________________________________________________ 44-45
Cleaning ______________________________________________________ 46
IC block diagrams ____________________________________________ 47-53
Service parts lists ____________________________________________ 54-86
Electrical parts list ______________________________________ 54-78
Mechanical parts list ____________________________________ 79-80
Optical parts list ________________________________________ 81-85
Drawings & Diagrams ______________________________________ A1-A15
Parts description and reading in schematic diagram ____________________ A2
Circuit block diagram ____________________________________________ A3
Power supply lines ______________________________________________ A4
Schematic diagrams ________________________________________ A5-A11
Printed wiring board diagrams ________________________________ A12-A14
Pins description of ICs, transistors, diodes __________________________ A15
-3-
Safety Instructions
WARNING: The chassis of this projector is isolated (COLD) from AC line by using the converter transformer. Primary side of the converter and lamp power supply unit circuit is connected to the AC line and it is hot, which hot circuit is iden­tified with the line ( ) in the schematic diagram. For continued product safety and protection of personnel injury, servicing should be made with qualified personnel.
The following precautions must be observed.
SAFETY PRECAUTIONS
1: An isolation transformer should be connected in the
power line between the projector and the AC line before any service is performed on the projector.
2: Comply with all caution and safety-related notes pro-
vided on the cabinet back, cabinet bottom, inside the cabinet or on the chassis.
3: When replacing a chassis in the cabinet, always be
certain that all the protective devices are installed properly, such as, control knobs, adjustment covers or shields, barriers, etc.
DO NOT OPERATE THIS PROJECTOR WITHOUT THE PROTECTIVE SHIELD IN POSITION AND PROPERLY SECURED.
4: Before replacing the cabinet cover, thoroughly
inspect the inside of the cabinet to see that no stray parts or tools have been left inside.
Before returning any projector to the customer, the service personnel must be sure it is completely safe to operate without danger of electric shock.
SERVICE PERSONNEL WARNING
Eye damage may result from directly viewing the light produced by the Lamp used in this equipment. Always turn off Lamp before opening cover. The Ultraviolet radiation eye protection required during this servicing. Never turn the power on without the lamp to avoid electric-shock or damage of the devices since the stabilizer generates high voltages(15kV - 25kV) at its starts. Since the lamp is very high temperature during units operation replacement of the lamp should be done at least 45 minutes after the power has been turned off, to allow the lamp cool-off.
PRODUCT SAFETY NOTICE
Product safety should be considered when a component replacement is made in any area of the projector. Components indicated by mark in the parts list and the schematic diagram designate components in which safety can be of special significance. It is, therefore, particularly recommended that the replacement of there parts must be made by exactly the same parts.
DO NOT ATTEMPT TO SERVICING THE
REMOTE CONTROL UNIT.
Laser Beam may be leaked out when in disassemble the Unit. As the Laser Beam used in this Remote con­trol unit is harmful to the eyes.
LASER RADIATION DO NOT STARE INTO BEAM
MAX. OUTPUT: 1mW WAVE LENGTH: 650 ±20nm CLASS
II LASER PRODUCT
This product is complied with 21 CFR
part 1040.10
CAUTION
LASER RADIATION DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT LASER-STRAHLING NICHT IN DEN STRAHL BLICKEN LASER KLASSE 2
IEC60825-1, Am. 1 1997 MAX OUTPUT ( ) : 1 mW WAVE LENGTH ( ) : 650±20nm
-4-
Projector Type Multi-media Projector
Dimensions (W x H x D) 13.11x 3.52x 9.96(333mm x 89.5mm x 253mm)
Net Weight 9.3 lbs (4.2 kg) (PLC-XU32, XU37), 9.8 lbs (4.4 kg) (PLC-XU33, XU38)
LCD Panel System 0.9TFT Active Matrix type, 3 panels
Panel Resolution 1024 x 768 dots
Number of Pixels 2,359,296 (1024 x 768 x 3 panels)
Color System 6 color system (PAL, SECAM, NTSC, NTSC4.43, PAL-M and PAL-N)
High Definition TV SIgnals 480i, 480p, 575i, 575p, 720p. 1035i and 1080i
Scanning Frequency H-sync. 15 ~ 100kHz, V-sync. 50 ~ 100Hz
Projection Image Size (diagonal) Adjustable from 31to 300(PLC-XU32, XU37)
Adjustable from 34to 300(PLC-XU33, XU38)
Horizontal Resolution 800 TV lines
Projection Lens F 1.7 ~ 2.0 lens with f 37.4mm ~ 48.3mm with motor zoom and focus (PLC-XU32, XU37)
F 1.9 ~ 2.1 lens with f 21.3mm ~ 25.6mm with motor zoom and focus (PLC-XU33, XU38)
Throw Distance 5.3~ 40.0(1.6m ~ 12.2m) (PLC-XU32, XU37)
3.0~ 22.6(0.9m ~ 6.9m) (PLC-XU33, XU38)
Projection Lamp 200watts
Video Input Jacks RCA Type x 3 (Video/Y, Cb/Pb, Cr/Pr) and Mini DIN 4 pin x 1(S-Video)
Audio Input Jacks RCA Type x 2
Computer Input Terminal DVI-I Terminal (Digital/Analog)
Monitor Output Terminal (VGA) HDB15 Terminal x 1
Computer Audio Input Jack Mini Jack (stereo)
Control Port Connector Mini DIN 8 pin x 1
USB Connector USB Series B receptance x 1
Audio Output Jacks RCA Type x 2
Internal Audio Amp. 1.0watt RMS (monaural)
Built-in Speaker 1 speaker, 1.18x 1.57(30mm x 40mm)
Feet Adjustment 0˚ to 15.6˚
Voltage and AC 100 ~ 120V (3.6A Max. Ampere), 50/60Hz (The U.S.A and Canada)
Power Consumption AC 200 ~ 240V (1.8A Max. Ampere), 50/60Hz (Continental Europe and the U.K)
Operating Temperature 41˚F ~ 95˚F (5˚C ~ 35˚C)
Storage Temperature 14˚F ~ 140˚F (-10˚C ~ 60˚C)
Remote Control Transmitters Wireless Remote Control, batteries AA, UM3 or R06 Type x 2
Specifications
The specifications are subject to change without notice.
This symbol on the nameplate means the product is Listed by Underwriters Laboratories Inc. It is designed and manufactured to meet rigid U.L. safety stan­dards against risk of fire, casualty and electrical hazards.
-5-
Condenser lens adjustment ❍●
Condenser lens-out adjustment ❍●
Relay lens-out adjustment ❍●
Contrast Adjustment
R-Contrast adjustment
G-Contrast adjustment
B-Contrast adjustment
Output voltage adjustment
Fan voltage adjustment
Pedestal adjustment
NRS adjustment
Signal center adjustment
Black level adjustment
PC offset adjustment
PC gain adjustment
AV gain adjustment
Common center adjustment
Gamma shift adjustment
White balance adjustment
Disassembly / Replaced Parts
LCD/
Prism
Assy
Condenser
Lens
Polarized glass
RGB
Optical Adjustments
Electrical Adjustments
: Adjustment necessary : Check necessary
P. F .
Board
Main
Board
Condenser
Lens-Out
Adjustments after Parts Replacement
Relay
Lens-Out
Powe r Board
-6-
Interlock switch
The interlock switch (SW904) cuts off the AC mains power supply when the lamp cover is removed. After opening the lamp cover for replacing the lamp assy, place the lamp cover correctly otherwise the projector can not turn on.
Thermal switch
There is the thermal switch (SW902) inside of the projector to prevent the internal temperature from rising abnormally. When the internal temperature reaches near 100˚C, turn off the AC main power supply automatically. The thermal switch is not reset to normal automatically even if the internal temperature becomes normal. Reset the thermal switch following procedure. Check the resistance between terminals of thermal switch by using the tester. If it has high impedance, thermal switch may be in operative.
How to reset the thermal switch
1.
Remove the cabinet top following to Mechanical
Disassemblies”.
2. Press the reset button on the thermal switch.
CAUTION:
Before press the reset button, disconnect the AC cord from the projector.
Circuit Protections
This projector is equipped with the following circuit protections to operate in safety. If the abnormality occurs inside the projector, it will automatically turn off by operating one of the following protection circuits.
Fuse
The fuse is located inside of the projector. When either the LAMP indicator or the READY indicator is not illuminated, fuse may be opened. Check the fuse as following steps. It should be used the specified fuse as follows;
How to replace the fuse
1. Remove the cabinet top following to Mechanical
Disassemblies”.
2. Remove the fuse from fuse holder.
To install the fuse, take reversed step in the above.
Fuse Part No.: 423 022 2102 TYPE T4.0AH 250V FUSE LITTLE FUSE INC. TYPE 215004
Fuse
Thermal switch (SW902)
Reset Button
Line Filter Board
-7-
Circuit Protections
Warning temperature and power failure protection
The TEMP WARNING indicator flashes red and the projector will automatically turn off when the internal tempera­ture of the projector exceeds the normal temperature or when stopping cooling fans or when the internal power supply lines are failed.
Check the following possible causes and wait until stopping the TEMP WARNING indicator flashing.
Possible causes
- Air filter is clogged with dust particles. Remove dust from the air filter by following instructions in the Air filter care and cleaningbelow.
- Ventilation slots of the projector are blocked. In such an event, reposition the projector so that ventilation slots are
not obstructed.
- Check if projector is used at higher temperature place (Normal operating temperature is 5 to 35 ˚C or 41 to 95˚F)
If the TEMP WARNING indicator still continues to flash, there may be defects on cooling fans or power supply cir­cuits. Please check fan operation and power supply lines referring to the Power Supply Lines Chart”.
Air filter care and cleaning
The removable air filter prevents dust from accumulation on the surface of the projection lens and projection mirror. Should the air filter become clogged with dust particles, it will reduce the cooling fans effectiveness and may result in internal heat build up and reduce the life of the projector.
To clean up the air filter, follow the cleaning procedure below:
1. Turn the power off, and disconnect the AC power cord
from the AC outlet.
2. Turn the projector up side down and remove an air filter
by pulling the latches of them upward.
3. Clean the air filter with brush or wash out the dust and
particles.
4. Replace the air filter properly. Make sure that the air fil-
ter is fully inserted.
CAUTION:
Do not operate the projector with the air filter removed. The dust is stuck on the LCD panel and the mirror, and it may spoil the fine picture image. Do not put the small parts into the air intake vents. It may result in the malfunction of the projector. The air filter is small parts. Take care that children dont eat or swallow it.
RECOMMENDATION
We recommend to avoid dusty, smoky place for operating the projector. Using in dusty place may cause the picture of poor quality. When using under the dusty or smoky conditions, dust may accumulate on the LCD panel and lens inside it, and may resultantly be projected on the screen together with the picture. When the above symptoms are noticed, please clean up the LCD panel and lens following to the Cleaning Method”.
Air filter
-8-
1 Remove 4 screws A to take the Cabinet Top Assy upward off. 2 Remove the Control Panel off from the Cabinet Top by lifting the edge of
control panel.
Mechanical Disassemblies
Mechanical disassemble should be made following procedures in numerical order. Following steps show the basic procedures, therefore unnecessary step may be ignored.
Caution:
The parts and screws should be placed exactly the same position as the original otherwise it may cause loss of performance and product safety.
Fig.1
1 Remove 8 screws to take the Main Board upward off.
Fig.2
Cabinet Top and Control Panel removal
1
Main Board removal
2
A
A
A
A
Main Board
Control panel
Cabinet top
Temp board
-9-
Mechanical Disassemblies
1 Remove 1 screw A to release a grounding wire. 2 Pull the Rear Panel assy upward. 3 Remove 4 screws B and remove the AV Board. 4 Remove 4 screws C and remove the DVI Board. 5 Remove 4 screws D and remove the speaker. 6 Remove 1 screws E and remove the Temp Board..
Fig.3
Fig.4
1 Remove 4 screws A and unhook 2 hooks B at the both of left and right
side, and the take the Front Panel assy off.
2 Remove 1 screw C to take the R/C Board off.
AV, DVI, Temp Board and Speaker removal
3
Front Panel and R/C Board removal
4
A
B
B
B
C
A
A
A
A
B
C
DVI board
AV board
Speaker
R/C board
B
C
E
D
D
C
-10-
Mechanical Disassemblies
1 Remove 1 screw A and disconnect the Lamp Socket. 2 Remove 2 screws B to take the Lamp Ballast assy upward off. 3 Remove 2 screws C to take the isolation sheet off. 4 Remove 4 screws D to take the lamp ballast board off.
Fig.5
1
Remove 3 screws A and pull the Filter Board assy upward.
2 Remove 1 screw B to take the grounding lead from the cabinet bottom. 3 Remove 4 screws C to take the Filter Board off.
Fig.6
Lamp Ballast Unit removal
5
Filter Board removal
6
A
Lamp ballast board
B
B
D
D
D
D
A
A
A
B
C
C
C
C
Filter board
C
C
Isolation sheet
-11-
1 Remove 4 screws A to take the Fan(FN901) off. 2 Remove 4 screws B to take the Fan(FN905) off. 3 Remove 3 screws C to take the Power Box Cover upward off.
Mechanical Disassemblies
1 Remove 1 screw A to take the Lamp Cover off. 2 Loosen 3 screws B to take the Lamp assembly by
pulling the handle.
Step to next procedure.
Fig.8-1
Fig.7
Power Box Cover and Fans(FN901, FN906) removal
7
Optical Unit removal
8
-1
A
A
A
A
B
BB
B
C
C
C
FN901
FN906
Power box cover
Lamp cover
Lamp ass’y
A
B
B
B
Step from previous procedure.
3 Remove 6 screws C to take the Optical Unit upward upward off.
To mount optical unit, mount optical unit first then mount the Lamp assembly and Lamp Cover.
-12-
Mechanical Disassemblies
1 Remove 8 screws A to take the Power Board ass’y
upward off.
2 Remove 4 screws B to take the P. F. Board from the
Power Board.
3 Remove 3 screws C to take the Power Board holder
from the Cabinet Bottom.
Fig.9
Power and P.F. Board removal
9
A
Power board
A
A
A
A
A
A
A
B
B
B
B
C
C
C
P. F. board
Fig.8-2
Optical Unit removal
8
-2
Optical unit
C
C
C
C
C
C
1 Remove 1 screw A and take a Washer, Spring and
Interlock Switch lever.
2 Pull the Fan and duct assy upward, then remove the
2 screws B to take the Fan (FN906) off.
-13-
Mechanical Disassemblies
Fig.10
1 Remove 8 screws B and to take the Fan Duct
Top off and remove the Fans (FN902, FN903, FN904).
2 Remove 4 screws C to take the Fan Duct Bottom
off from the Cabinet Bottom.
Fig.11
Fan (FN905) removal
10
Fans (FN902, FN903, FN904) removal
11
Interlock switch lever
A
B
B
FN905
A
B
B
B
B
B
B
B
C
C
C
C
FN904
FN903
FN902
Fan duct top
-14-
1 Remove the Front Panel following to Front Panel Removal” on “Mechanical
Disassemblies”.
2 Remove 4 screws to take the Projection Lens assy off.
1 Remove 2 screws A and pull the Integrator Lens-In assy upward. 2 Remove 1 stoppers B and then take the Lens off from the holder.
Fig.1
Optical Parts Disassemblies
Before taking this procedure, remove Cabinet Top and Main Board following to the Mechanical Disassemblies”. Disassembly requires a 2.0mm hex wrench and a screwdriver.
Integrator Lens
* Lens should be placed as the
rugged surface side comes to the holder side.
Fig.2-
1
Fig.2-2
Projection Lens removal
Integrator Lens-In disassembly
Stopper B
A
A
-15-
1 Remove 2 screws A and pull the Condenser Lens assy upward. 2 Remove 4 screws B to take the Lens off from the holder.
1 Remove 2 screws A and pull the Condenser Lens-Out assy upward. 2 Remove 2 screws B to take the Lens off from the holder.
Note: Should be place the lens as shown in the figure.
A
Optical Pats Disassemblies
B
Condenser Lens
Fig.3-2
Fig.3-1
* Lens should be placed as the flat
surface side comes to the holder side.
Holder
A
A
Fig.4-2
Fig.4-1
B
B
Holder
Condenser Lens-Out
A
Condenser lens disassembly
Condenser Lens-Out disassembly
B
B
B
Side View
-16-
Optical Parts Disassemblies
1 Remove 2 screws A and pull the Relay Lens-Out assy upward. 2 Remove 2 screws B to take the Lens off from the holder.
Note: There is no mounting direction of the lens.
1 Remove each screw and pull the Polarized Glass-In assy upward. 2 Unhook the stoppers and take the glass off upward.
Hooks
Polarized Glass-In
Fig.6-2
Fig.6-1
* Should be places the glass as the
film attached side comes to the prism side.
Phase Sheet
A
Fig.5-2
Fig.5-1
B
B
Holder
Relay Lens-Out
A
Relay Lens-Out disassembly
Polarized Glass-In removal
-17-
1 Remove 4 screws A and take the LCD/Prism assy off
upward from the optical unit.
2 Remove each screw B and take the glass off upward.
Note: Models PLC-XU37 and XU38 have a pre-polarized glass for the green panel is mounted in front of the polarized glass-out (G) as Fig.7-3.
LCD Panel/ Prism Ass’y
Note: Do not replace the LCD panel separately otherwise it can not obtain proper picture.
1 Remove 9 screws to take the Optical Unit Top off upward.
Fig.7-
1
Fig.8
Polarized Glass-Out/Pre-Polarized Glass removal
Optical Unit Top removal
Optical Parts Disassemblies
A
A
A
Optical Unit Top
Polarized Glass-Out
LCD Panel/Prism Assy
Fig.7-2
* Glasses should be placed as the
film attached side comes to the LCD panel side.
LCD Panel
B
Polarized Glass-Out(G)
Pre-Polarized Glass
Fig.7-3
* Model PLC-XU37, XU38 only
-18-
Optical Parts Disassemblies
When mounting or assembling the optical parts in the optical unit, the parts must be mounted in the specified location and direction as shown in figure below.
5
8
9
Fig.9
2
4
1
The printed marker comes this side.
13
3
7
10
Locations and Directions
6
12
1 Mirror (W) 2 Integrator lens (OUT) 3 Prism beam splitter (PBS) 4 Dichroic mirror (B) 5 Condenser lens (OUT) 6 Dichroic mirror (G) 7 Relay lens (IN) 8 Mirror (R)
9 Condenser lens (R) 10 Condenser lens 11 Condenser lens (B) 12 Optical filter (UV cut) 13 Mirror (B)
Key No. Description
The printed marker comes this side.
11
-19-
LCD Panel/Prism Ass’y Replacement
1 Remove the cabinet top and main board following to
Mechanical Disassemblies”.
2 Remove 4 screws by using the 2.0 mm hex driver and
take the LCD Panel/Prism assy off upward from the optical unit.
LCD Panel/Prism Assy
After replacing or installing the LCD Panel/Prism ass'y, please make sure to obtain the best focus in both TELE and WIDE zoom. If the focus adjustment is required, please adjust the positioning of LCD Panel/Prism Assy by following below procedure.
Mounting Procedure:
1 Loosen 4 screws A on the LCD Panel/Prism ass'y with
2.0 mm hex driver.
2 Turn the projector on and project the image with WIDE
zoom, and adjust the FOCUS control to obtain the best focus.
3 Turn the ZOOM control to the TELE position. 4 Move the LCD Panel/Prism Assy backward or forward
(about 0mm ~ 0.8mm) to obtain the proper focus. Confirm the focus at TELE and WIDE zoom.
5 Tighten 4 screws A to fix the LCD Panel/Prism ass'y.
T
op View
A
A
A
A
LCD Panel/Prism Ass’y
Note: Do not replace the LCD panel separately otherwise it can not obtain proper pic­ture.
IMPORTANT NOTICE on LCD Panel/Prism Ass'y Replacement
LCD panels used for this model can not be replaced separately. Do not disassemble the LCD Panel/Prism Ass’y. These LCD panels are installed with precision at the factory. When replacing the LCD panel, should be replaced whole of the LCD panels and prism assy at once. After replacing LCD Panel/Prism assy, please check the following adjustments.
- Check the Condenser Lens Adjustment” , “Condenser Lens-Out Adjustmentand Relay Lens-Out Adjustmentfollowing to chapter “Optical Adjustment”.
- Check the White Balance Adjustment” , “Common Center Adjustmentand Gamma Shift Adjustment following to chapter “Electrical Adjustment”.
- Check the white uniformity on the screen. If you find the color shading, please adjust the white uniformity by using the proper computer and Color Shading Correctionsoftware supplied separately. The software can be ordered as follows;
COLOR SHADING CORRECTION
Service Parts No. 645 051 2308
LCD Panel/Prism Ass’y removal
Note on LCD Panel/Prism Ass’y Mounting
-20-
WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can shatter and cause injury.
Procedure
1 Turn off the projector and disconnect the AC cord. Allow the projector to
cool for at least 45 minutes.
2 Remove a screw with a screwdriver and remove the lamp cover. 3 Remove 2 screws and pull out the lamp assembly by grasping the han-
dle.
4 Replace the lamp assembly securely and tighten 3 screws. 5 Place the lamp cover and tighten a screw. 6 Connect the AC cord to the projector and turn on.
Note:
- Do not reset the Lamp Replace Counter, except after lamp is replaced.
- The projector can not be turned-on with lamp cover removed, because when the lamp cover is removed, the interlock switch is also released to switch off the mains power for safety.
7 Reset the Lamp Replace Counter, see below explanation.
Lamp Replacement
1 Turn the projector on, and press the MENU button
and the on-screen menu will appear. Press the POINT LEFT/RIGHT buttons to move a red frame pointer to SETTING menu icon.
2 Press the POINT DOWN button to move a red frame
pointer to Lamp counter resetand then press the SELECT button.The message Lamp replace counter reset?is displayed. Move the pointer to [Yes] and the press the SELECT button.
3 Another confirmation dialog box appears and select
[Yes] to reset Lamp Replace Counter .
Please refer to the owners manual for further informa­tion.
Recommendation
Should the air filter become clogged with dust particles, it will reduce the cooling fan’s effectiveness and may result in internal heat build up and short lamp life. We recommend cleaning the air filter after the projection lamp is replaced. Refer to Air Filter Cleaning”.
Lamp cover
Lamp Assembly
Handle
ORDER REPLACEMENT LAMP
T
ype No.
Service Parts No.
POA-LMP35 610 293 2751
How to reset Lamp Replace Counter
The LAMP REPLACEMENT indicator will illuminate when the Lamp Replace Counter reaches 1000 hours. This is to indicate that lamp replacement is required.
You can check the lamp replace counter following to below procedure.
1 Press and hold the pointer UP on the projector for
more than 20 seconds.
2 The Lamp replace Counter is displayed on upper
left corner of the screen briefly.
* This model does not have Eco mode.
Lamp replace counter data
How to check Lamp Replace Counter
Normal 123 h Eco 0 h Total 123 h
-21-
[Before Adjustment]
- Input a 100% of black raster signal.
[R/G/B-CONTRAST ADJUSTMENT] 1 Loosen a screw A (Fig.1-1/1-2) on the polarized glass mounting
base which you intend to adjust.
2 Turn the polarized glass mounting base as shown in Fig.1-1 to
obtain the darkest brightness on the screen.
3 Tighten the screw A to fix the polarized glass mounting base.
Repeat steps 1 to 3 for remaining polarized glasses.
B-Polarized Glass Mounting Base
R-Polarized Glass Mounting Base
G-Polarized Glass Mounting Base
A
A
A
Slot B
Fig.1-2
Fig.1-1
Polarized glass
mounting base
Optical Adjustments
Main Board
A
Contrast adjustment
Before taking optical adjustments below, remove the Cabinet Top and Main Board following to the Mechanical Disassemblies Adjustments require a 2.0mm hex wrench and a slot screwdriver. When you adjust Condenser lens, Condenser lens-out or Relay lens adjustment, you need to disconnect some connectors and FPC cables of LCD panels on the main board. Note: Do not disconnect connectors K8N, K8P, K8H, K8R and K8S on the main board, because the projector can
not turn on due to operate the power failure protection.
-22-
Optical Adjustments
Fig.2-2
1 Turn the projector on by a state of without FPC cables. 2 Project only green light on the screen. 3 Adjust the adjustment base of condenser lens assy to make color
uniformity in green.
1) If the shading appears on the left or right of the screen as
shown in Fig.2-1, loosen 2 screws A with the 2.0mm hex driv­er, and adjust the slot B to make color uniformity in green by using a slot screwdriver.
2) If the shading appears on the top or bottom of the screen as
shown in Fig.2-2, loosen 2 screw C with the 2.0mm hex driver, and adjust the slot D to make color uniformity in green by using a slot screwdriver
4 Tighten screws A and C to fix the Condenser lens unit.
Note: The relay lens adjustment must be carried out after completing this adjustment.
y
x
Moving of Slot D
Slot D
C
a
b
a
b
Moving of slot B
Fig.2-1
Slot B
A
C
y
x
Green
Green
Condenser Lens adjustment
A
-23-
1 Turn the projector on by a state of without FPC cables. 2 Project green and blue lights on the screen. 3 Adjust the adjustment base of condenser lens-out assy to make
color uniformity in cyan.
1) If the shading appears on the left or right of the screen as shown
in Fig.3-1, loosen 1 screw A with the 2.0mm hex driver, and adjust the slot B to make color uniformity in cyan by using a slot screwdriver.
2) If the shading appears on the top or bottom of the screen as
shown in Fig.3-2, loosen 1 screw C with the 2.0mm hex driver, and adjust the slot D to make color uniformity in cyan by using a slot screw driver.
4 Tighten the screw A and C to fix the relay lens unit.
Fig.3-1
A
Slot B
Optical Adjustments
a
b
b
Moving of slot B
a
Cyan
Fig.3-2
D
Moving of slot D
y
x
C
Condenser Lens-Out adjustment
y
x
Cyan
-24-
1 Turn the projector on by a state of without FPC cables. 2 Project all of lights on the screen. 3 Adjust the adjustment base of relay lens assy to make color unifor-
mity in white.
1) If the shading appears on the left or right of the screen as shown
in Fig.4-1, loosen 1 screw A with the 2.0mm hex driver, and adjust the slot B to make color uniformity in white by using a slot screwdriver.
2) If the shading appears on the top or bottom of the screen as
shown in Fig.4-2, loosen 1 screw C with the 2.0mm hex driver, and adjust the slot D to make color uniformity in white by using a slot screwdriver.
4 Tighten the screws A and C to fix the relay lens unit.
Fig.4-1
A
Slot B
a
b
b
Moving of slot B
a
White
Fig.4-2
Slot D
Moving of slot D
y
x
C
Optical Adjustments
y
x
Relay lens-Out adjustment
White
-25-
Electrical Adjustments
To enter the service mode
To enter the Service Mode, press and hold the MENU and IMAGE button on the projector at the same time for more than 3 seconds. The service menu appears on the screen as follows.
To adjust service data
Select the adjustment group no. by pressing the MENU (+) or IMAGE (-) button, and select the adjustment item no. by pressing the pointer UP or DOWN button, and change the data value by pressing the VOLUME – or VOL- UME + button. Refer to the Service Adjustment Data Tablefor further description of adjustment group no., item no. and data value.
To exit the service mode
To exit the service mode, press the POWER ON-OFF button on the projector or remote control unit.
Service Adjustment Menu Operation
IC1801 on the main board stores the data for the serv­ice adjustments, and should not be replaced except for the case of defective device. If replaced, it should be performed the re-adjustments following to the “Electrical Adjustments”. The data of lamp replacement monitor timer is stored in the IC1801. Please note that the lamp replace counter is reset when the memory IC (IC1801) is replaced. (Lamp replace counter can not be set to the previous value.)
Caution to memory IC replacement
When IC1801 is replaced with new one, the CPU writes down the default data of the service adjustments to the replaced IC, refer to the service adjustment table. As these data are not the same data as factory shipped data, it should be required to perform the re-
adjustments following to the “Electrical Adjustments”. Please note that the lamp replace counter is reset.
Caution of Main Board replacement (in the case IC1801 is not defective)
When the main board is replaced, IC1801 should be replaced with the one on previous main board. After replacement, it should be required to perform the re­adjustments following to the “Electrical Adjustments”. In this case, the lamp replace counter can be kept the v
alue as before.
Memory IC Replacement
Group No.
Data value
Item No.
Service Mode Input Video Group No. Data
0032
Ver. 1 .00
-26-
After replacing the Power Board, PF.C. Board, readjust the Output voltage adjustment as follows.
1. Connect a digital voltmeter to pins 1 (+) and 3 (-) of
K6D.
2. Adjust the voltage by using VR611 as following.
A
C Input Reading
230V 370V ±2V
or 120V 340V ±2V
Caution: Be sure to connect the lamp when taking this adjust­ment.
Circuit Adjustments
CAUTION: The each circuit has been made by the fine adjustment at factory. Do not attempt to adjust the follow-
ing adjustments except requiring the readjustments in servicing otherwise it may cause loss of per­formance and product safety.
[Adjustment Condition]
Input signal
Video signal .......................... 1.0Vp-p/75terminated, 16 steps gray scale (Composite video signal)
Computer signal...................... 0.7Vp-p/75terminated, 16 steps gray scale pattern (XGA)
Picture control mode ...................... “STANDARDmode unless otherwise noted.
Note:
* Please refer to Service Adjustment Menu Operationfor entering to the service mode and adjusting the service
data.
Electrical Adjustments
Output Voltage adjustment
1. Enter the service mode and select group no. 11and item no. 0. Set data value to 1”.
2. Connect a digital voltmeter to test point TP12V1(+) and chassis ground (-). Select item no. 1and change data value to adjust voltage to be 7.5 ±0.1V.
3. Connect a digital voltmeter to test point TP12V2(+) and chassis ground (-). Select item no. 2and change data value to adjust voltage to be 9.0 ±0.1V.
4. Select group no. 11and item no. 0and set data value to 3”.
5. Connect a digital voltmeter to test point TP12V1(+) and chassis ground (-). Select item no. 3and change data value to adjust voltage to be 13.5 ±0.1V.
6. Connect a digital voltmeter to test point TP12V2(+) and chassis ground (-). Select item no. 4and change data value to adjust voltage to be 13.5 ±0.1V.
Fan Voltage adjustment [For PLC-XU32/XU37]
1. Enter the service mode and select group no. 11and item no. 0. Set data value to 1”.
2. Connect a digital voltmeter to test point TP12V1(+) and chassis ground (-). Select item no. 1and change data value to adjust voltage to be 8.0 ±0.1V.
3. Connect a digital voltmeter to test point TP12V2(+) and chassis ground (-). Select item no. 2” and change data value to adjust voltage to be 9.0 ±0.1V.
4. Select group no. 11and item no. 0and set data value to 3”.
5. Connect a digital voltmeter to test point TP12V1(+) and chassis ground (-). Select item no. 3and change data value to adjust voltage to be 13.5 ±0.1V.
6. Connect a digital voltmeter to test point TP12V2(+) and chassis ground (-). Select item no. 4and change data value to adjust voltage to be 13.5 ±0.1V.
Fan Voltage adjustment [For PLC-XU33/XU38]
-27-
Electrical Adjustments
1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.
[R-SIGNAL CENTER ADJUSTMENT]
4. Connect a digital voltmeter to test point TP25R1” (+)
and chassis ground (-).
5. Select group no. 3, item no. 0and change data
value to adjust the voltage to be 7.30 ±0.05V.
[G-SIGNAL CENTER ADJUSTMENT]
6. Connect a digital voltmeter to test point TP25G1” (+)
and chassis ground (-).
7. Select group no. 3, item no. 1and change data
value to adjust the voltage to be 7.30 ±0.05V.
[B-SIGNAL CENTER ADJUSTMENT]
8. Connect a digital voltmeter to test point TP25B1” (+)
and chassis ground (-).
9. Select group no. 3, item no. 2and change data
value to adjust the voltage to be 7.30 ±0.05V.
1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Connect an oscilloscope to test point “TP3551” (+) and chassis ground (-).
4. Enter the service mode, select group no. 3, item no. 7and change data value to adjust amplitude ato be 5.5 ±0.1V.
Signal Center adjustment
NRS adjustment
1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.
[R-BLACK ADJUSTMENT]
4. Connect an oscilloscope to test point TP25R1” (+)
and chassis ground (-).
5. Select group no. 3, item no. 3and change data
value to adjust amplitude “a” to be 10.0 ±0.1V.
[R-BLACK ADJUSTMENT-]
6. Connect an oscilloscope to test point TP25G1” (+)
and chassis ground (-).
7. Select group no. 3, item no. 4and change data
value to adjust amplitude “a” to be 10.0 ±0.1V.
[R-BLACK ADJUSTMENT-]
8. Connect an oscilloscope to test point TP25B1” (+)
and chassis ground (-).
9. Select group no. 3, item no. 5and change data
value to adjust amplitude “a” to be 10.0 ±0.1V.
Black Level adjustment
1. Receive the 16-step grey scale video signal.
2. Set to VIDEO mode.
3. Enter the service mode.
[R-PEDESTAL ADJUSTMENT]
4. Connect an oscilloscope to test point TP201R” (+)
and chassis ground (-).
5. Select group no. 3, item no. 14and change data
value to adjust the pedestal level and black level to be the same level.
[G-PEDESTAL ADJUSTMENT]
6. Connect an oscilloscope to test point TP201G” (+)
and chassis ground (-).
7. Select group no. 3, item no. 15and change data
value to adjust the pedestal level and black level to be the same level.
[B-PEDESTAL ADJUSTMENT]
8. Connect an oscilloscope to test point TP201B” (+)
and chassis ground (-).
9. Select group no. 3, item no. 16and change data
value to adjust the pedestal level and black level to be the same level.
Pedestal adjustment
(a)
Pedestal level = Black level
(a)
black level
(a)
black level
-28-
Electrical Adjustments
1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.
[R-GAIN ADJUSTMENT]
4. Connect an oscilloscope to test point TP25R1” (+)
and chassis ground (-).
5. Select group no. 2, item no. 3and change data
value to adjust waveform “a” to be minimum ampli­tude.
[G-GAIN ADJUSTMENT]
6. Connect an oscilloscope to test point TP25G1” (+)
and chassis ground (-).
7. Select group no. 2, item no. 4and change data
value to adjust waveform “a” to be minimum ampli­tude.
[B-GAIN ADJUSTMENT]
8. Connect an oscilloscope to test point TP25B1” (+)
and chassis ground (-).
9. Select group no. 2, item no. 5and change data
value to adjust waveform “a” to be minimum ampli­tude.
PC Gain adjustment
1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.
[R-OFFSET ADJUSTMENT]
4. Connect an oscilloscope to test point TP25R1” (+)
and chassis ground (-).
5. Select group no. 3, item no. 11and change data
value to adjust the waveform “a(black portion ) to be maximum amplitude.
[G-OFFSET ADJUSTMENT]
6. Connect an oscilloscope to test point TP25G1” (+)
and chassis ground (-).
7. Select group no. 3, item no. 12and change data
value to adjust the waveform “a(black portion ) to be maximum amplitude.
[B-OFFSET ADJUSTMENT]
8. Connect an oscilloscope to test point TP25B1” (+)
and chassis ground (-).
9. Select group no. 3, item no. 13and change data
value to adjust the waveform “a(black portion ) to be maximum amplitude.
PC Offset adjustment
Black Level
(a)
White Level
(a)
-29-
Electrical Adjustments
[PC-GAMMA OFF ADJUSTMENT]
1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode, select group no. 2, item no. 6and change data value to reproduce the prop­er gray scale picture on the screen.
[AV-GAMMA OFF ADJUSTMENT]
4. Receive the 16-step gray scale video signal.
5. Set to VIDEO mode.
6. Enter the service mode, select group no. 2, item no. 6and change data value to reproduce the prop­er gray scale picture on the screen.
1. Receive the 1 dot black & white pattern computer sig­nal.
2. Set to COMPUTER mode.
3. Enter the service mode.
[G-COMMON CENTER ADJUSTMENT]
4. Project only green light component to the screen.
5. Select group no. 3, item no. 8and change data value to obtain the minimum flicker on the screen.
[B-COMMON CENTER ADJUSTMENT]
6. Project only blue light component to the screen.
7. Select group no. 3, item no. 9and change data value to obtain the minimum flicker on the screen.
[R-COMMON CENTER ADJUSTMENT]
8. Project only red light component to the screen.
9. Select group no. 3, item no. 10and change data value to obtain the minimum flicker on the screen.
Gamma Shift adjustment
Common Center adjustment
1. Receive the 16-step gray scale video signal.
2. Set to VIDEO mode.
3. Enter the service mode.
[R-GAIN ADJUSTMENT]
4. Connect an oscilloscope to test point TP25R1” (+)
and chassis ground (-).
5. Select group no. 2, item no. 3and change data
value to adjust waveform “a” to be minimum ampli­tude.
[G-GAIN ADJUSTMENT]
6. Connect an oscilloscope to test point TP25G1” (+)
and chassis ground (-).
7. Select group no. 2, item no. 4and change data
value to adjust waveform “a” to be minimum ampli­tude.
[B-GAIN ADJUSTMENT]
8. Connect an oscilloscope to test point TP25B1” (+)
and chassis ground (-).
9. Select group no. 2, item no. 5and change data
value to adjust waveform “a” to be minimum ampli­tude.
AV Gain adjustment
[PC WHITE BALANCE ADJUSTMENT]
1. Receive the 16-step gray scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode, select group no. 2, item no. 7(Red) or 8(Blue), and change data values respectively to make a proper white balance.
[AV WHITE BALANCE ADJUSTMENT]
4. Receive the 16-step grey scale video signal.
5. Set to VIDEO mode.
6. Enter the service mode, select group no. 2, item no. 7(Red) or 8(Blue), and change data values respectively to make a proper white balance.
Confirm that the same white balance is obtained in video and computer input.
White Balance adjustment
If you find the color shading on the screen, please adjust the white uniformity by using the proper comput­er and Color Shading Correctionsoftware supplied separately. The software can be ordered as follows;
COLOR SHADING CORRECTION
Service Parts No. 645 051 2308
NOTE ON WHITE UNIFORMITY ADJUSTMENT
(a)
White Level
Group: 0 TB1274
0 TINT 32 0 ~ 63
1 SHP_EQ 2 0 ~ 3
2 SHP_FO 1 0 ~ 3
NTSC,PAL SECAM,NT4.43 S-Video Y,Cb,Cr
3 SHP_GAIN 10 10 10 10 0 ~ 15
NTSC NT4.43 PAL SECAM
4 Y_OUT_LEVEL 30 30 31 31 0 ~ 63
S-Video NTSC S-Video PAL S-Video SECAM Y,Cb,Cr
30 31 31 31
NTSC NT4.43 PAL SECAM
5 C_OUT_LEVEL 32 32 32 32 0 ~ 63
S-Video NTSC S-Video PAL S-Video SECAM Y,Cb,Cr
32 32 32 32
NTSC PAL SECAM NT4.43 PAL 60
6 Y_DELAY 6 6 6 4 4 0 ~ 15
S-Video NTSC S-Video PAL S-Video SECAM S-Video NT4.43 S-Video PAL60
443 34
7 COL_SYS - -
8 X’TAL - -
9 NOISE_DET - -
10 V_FREQ - - Read only
11 Vert. Std - -
12 CID - -
13 V_SIG - -
NTSC,PAL SECAM,NT4.43 S-Video YCbCr
14 Cinema SHP_GAIN 8 8 8 8 0 ~ 15 For cinema mode
Group: 1 CXA2101
0 PICTURE 30 0 ~ 63
1 BRIGHT 31 0 ~ 63
2 R_DRIVE 31 0 ~ 63
3 G_DRIVE 31 0 ~ 63
4 B_DRIVE 31 0 ~ 63
5 HSEP_SEL 1 0 ~ 1
6 CR_OFFSET1 15kHz: 7 Others: 10 0 ~ 15
7 CB_OFFSET1 15kHz: 7 Others: 10 0 ~ 15
8 BLK_BOTTOM 15 0 ~ 15
NTSC PAL, SECAM 1035i Y,Cb,Cr *1 *1 Y, Cb, Cr and Y, Pb, Pr except 1035i
9 R-Y/R 6 13 6 6 0 ~ 15
10 R-Y/B 5 15 5 5 0 ~ 15
11 G-Y/R 8 8 8 8 0 ~ 15
12 G-Y/B 10 4 10 10 0 ~ 15
13 MAT_OUT 0 0 0 1 0 ~ 3
15kHz 480i, 575i 480p, 575p 1080i, 1035i, 720p
14 SYSTEM 0 1 2 0 ~ 3
15 V_TC 3 3 3 0 ~ 3
16 H_WIDTH 3 2 0 0 ~ 3
17 HS_MASK 0 1 1 0 ~ 1
Video, S-Video 480i, 575i 480p, 575p 1080i, 1035i, 720p
18 CTI_LEVEL 2 2 2 2 0 ~ 3
15kHz 480i, 575i 480p, 575p 1080i, 1035i, 720p
19 SUB_SHP 3 3 3 0 ~ 3
20 SHP_FO 0 2 3 0 ~ 3
21 PRE_OVER 2 2 3 0 ~ 3
22 LTI_LEVEL 0 1 1 0 ~ 3
23 D_PIC 0 0 0 0 ~ 3
24 HUE 31 0 ~ 63 Only adjustable for PAL,SECAM
NTSC PAL,SECAM 525i,480p 625i,575p 1035i Others
25 SUB_COL 5 5 12 12 6 9 0 ~ 15
26 SUB_HUE 7 7 8 7 9 6 0 ~ 15
27 Cinema CTI_LEVEL 2 0 ~ 3 Set this value at Cinema Mode
-30-
Electrical Adjustments
Service Adjustment Data Table
These initial values are the reference data written from the CPU ROM to memory IC when replaced new memory IC. The adjust­ment items indicated with are required to readjust following to the Electrical adjustments. Other items should be used with the initial data value.
No. Adjustment Item Initial Value Range Description
Loading...