Sanyo LMU-TK40D2, LMU-TK40C2 Instruction Manual

Industrial LCD Monitor
LMU-TK40D2 (Page 1 to 41) LMU-TK40C2 (Supplementary page 42 to 75)
User's Guide
1
Table of contents
Precautions ............................................................................................... 2
Before First Use
Check Accessories................................................................................. 3
Outer Dimension.................................................................................. 5,6
Installation............................................................................................ 7,8
Names and Functions (Remote Controller)....................................... 9,10
Preparation for remote control.............................................................. 11
LCD Monitor Instructions
Adjusting the Screen............................................................................. 12
Adjustment Items............................................................................. 12,13
Mode..................................................................................................... 14
Adjustment Procedure
Before Adjustment...................................................................... 15-17
Adjustment for computer screen
A. Picture Menu................................................................. 18-21
B. Advanced Menu............................................................ 22,23
C. Picture in picture Menu................................................. 24-28
D. Advanced picture in picture Menu................................. 29,30
E. Options Menu................................................................ 31-33
F. Utilities Menu................................................................. 34,35
Additional Functions
Power Management System ........................................................... 36
Plug and Play .................................................................................. 36
Maintenance............................................................................................ 37
Troubleshooting
Fault Finding......................................................................................... 38
Screen Display...................................................................................... 38
Specifications
Cable Pin Arrangement ........................................................................ 40
Monitor Specifications........................................................................... 41
2
LMU-TK40D2
2
Precautions
Important matters
• Plug the included AC Power Cord to the power supply and voltage as mentioned in the rating label. IF NOT, DAMAGE TO THE AC POWER CORD IS A SAFETY RISK AND CAN CAUSE A FIRE.
Placement precautions
• Avoid placing the unit in humid or dusty places, or where it will be exposed to excessive heat (direct sunlight, heaters, etc.)
• Do not step on or set anything on the AC Power Cord. DAMAGE TO THE AC POWER CORD IS A SAFETY RISK AND CAN CAUSE A FIRE.
• Install the unit only on a stable and smooth surface.
• Do not connect the unit to the same AC outlet with appliances that generate large amounts of interference (such as heaters with thermostats, appliances with motors, etc.). It is best to use a completely separate electrical outlet.
• Keep the unit away from water or small objects. If they accidentally enters the unit, unplug the AC power cord immediately. DO NOT PLUG IN THE UNIT AGAIN.
• Never cover the rear ventilators with cloth or something.
Handling precautions
•"WARNING: The AC power cord and cables on this product contains chemicals, including lead, known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling."
• Avoid bending, kinking or damaging the AC Power Cord.
• Never insert or remove the power cord with wet hands. Also, be sure to hold cord by the plug when removing it from the outlet.
• Do not remove any parts that are held in place with screws. (The unit does not contain any user-serviceable items.)
• Maintain standard room temperature (5˚C to 35˚C, or 41˚F to 95˚F) during use. Do not subject the unit to shock or vibration. Do not move the unit while it is in use.
• A rapid increase in room temperature in cool weather can cause condensation to form inside the unit. If this occurs, wait at least 15 minutes after turning the unit on before attempting to operate it.
Microsoft and Windows are registered trademarks of Microsoft Corporation in the U.S.A. and other countries.
European Norm Compatibility / CE
This machine is provided with the CE-mark and therewith corresponding to the norms that are valid for its operation at present. Thus the effective guidelines on the electromagnetic compatibility 89/336/EWG and safety regulations according to low voltage guideline 73/23/EWG and 93/68/EWG are guaranteed. Mutual disturbances with other electronic appliances are normally excluded, if those also are in accordance with valid norms. Sporadically disturbances cannot, however, be excluded. The product is in conformity with the directives of the valid European guideline.
3
Before First Use
Names and Functions (Monitor)
Display Screen
Front View
Check Accessories
Check that the main unit and all accessories are present.
¡¡
AC Power Cord ( x1)
¡¡
Remote Controller ( x1)
¡¡
AA Batteries (
x
2)
¡¡
RGB Cable ( x1)
¡¡
User's Guide (
x
1)
¡ When you move the LCD monitor, please unplug AC cables connected to AC-IN
and disconnect the cables connected to the external equipments.
¡ When you carry the LCD monitor, please be careful not to shock it. To avoid
damaging the LCD panel, be sure not to touch the LCD panel when carrying the monitor.
NOTE
4
LMU-TK40D2
Rear View
Ventilators
Ventilators
Ventilators
Power Switch ( )
Turns the power to the monitor on and off.
AC-IN
RGB Connector DVI Connector
External Control Connector ( )
5
Before First Use
Outer Dimension
External Control
RGB
DVI
AC-IN
POWER
IR
Ventilators
6
LMU-TK40D2
Ventilators
Ventilators
Ventilators
Ventilators
Ventilators
Ventilators
Mounting Area
4-M6 (Depth : Min.12mm/Max.20mm)
Ventilators
When you install the LCD Monitor, please take care the following:
Use the M6 screws only for installation.
The maximum length of the screw put through a
hole is 20mm on the surface of a metal chassis (as shown right). Use the screw with effective length 12-20mm, if not it may damage to the LCD monitor.
When you install the LCD monitor, please check the strength of material to be secured.
L: 12mm(min.) 20mm(max.)
7
Before First Use
Installation
External OSD Connector
DVI Connector
RGB Connector
DVI Cable
(not included)
RGB Cable
Connect to the computer’s connectors
* The illustrations of monitor and AC Power Cord above-mentioned
are designed for using in North America.
Power Plug
AC Power Cord
AC-IN
Connect the Computers
Before doing anything, make sure the Power Switch on the monitor and a computer are turned off.
1
Plug the cable(s) into the connector on the monitor securely and fix them in place with two screws (each).
2
Plug the other end of the cable(s) into the connector on a computer.
3
Plug the AC Power Cord into the AC-IN on the monitor.
4
Plug the Power Plug into an outlet.
5
Switch on the monitor before starting up a computer.
8
LMU-TK40D2
How to secure the monitor on a wall
Note:The following figure is only recommended.
Never cover the rear ventilators with cloth or something. Secure enough space more than 30mm from the rear part of the monitor.
Side view of the monitor
Rear view of the monitor
Side view of the monitor
Rear view of the monitor
M6 bolt (4 places)
M6 bolt (4 places)
Depth: Min. 12mm Max. 20mm
Bracket (not included)
Bracket (not included)
Depth: Min. 12mm Max. 20mm
UP
b
UP
b
Vertical
Horizontal
Caution
9
Before First Use
Names and Functions (Remote Controller)
Remote Controller
10
LMU-TK40D2
Standby key
Standby ON/OFF.
Menu key
Show Main menu. Used to move cursor leftward while displaying the menu.
Wide key
Set the scale mode in wide.
Numeric keys (see page 72)
Used to switch each input signal. [0], [8] and [9] keys are not used. [1] Analog RGB1 selection [2] Digital RGB selection [3] Composite VIDEO selection [4] S-Video selection [5] Analog RGB2 selection [6] Component VIDEO selection [7] RGB+CSync selection
key (see page 72)
Zoom out the picture.
Source key
Search and switch to current input signal automatically.
Escape key
Escape from menu.
Menu key
Show Main menu. Used to move cursor rightward while displaying the menu.
Direction keys
key
・・・Select upper items in the menu.
key・・・Select lower items in the menu. key・・・Change set level down or move the cursor leftward. key・・・Change set level up or move the cursor rightward.
Zoom key (see page 72)
Display Zoom menu.
Quick Menu key (see page 70,71)
Display Quick menu.
key (see page 72)
Zoom in the picture.
11
Before First Use
Preparation for remote control
O P E N
O P E N
Rearview
2
Be sure and put two AA dry batteries into the remote controller. Make sure of the direction of them as indicated inside the remote controller.
3
Replace the lid by sliding it up over the batteries until it is firmly in place.
1
Remove the battery compartment lid with pushing .
O P E N
12
LMU-TK40D2
Adjusting the Screen
LCD Monitor Instructions
This LCD monitor decodes the signal from a computer automatically, and displays the image on a screen in accordance with the preset mode. Unless a display mode has been in preset table, the image is displayed under the similar mode in preset table. In this case, the adjustment for this LCD monitor must be done in accordance with a computer connected with. Please follow the OSD (On Screen Display) menu to adjust screen settings.
Picture Menu (refer to page 18-21)
Adjustment Items for a computer screen
BRIGHTNESS
Adjust the brightness for the screen
CONTRAST
Adjust the contrast for the screen
H POSITION
Adjust the horizontal position for the screen
V POSITION
Adjust the vertical position for the screen
PHASE
Adjust the phase for the screen
FREQUENCY
Adjust the horizontal width for the screen
SCALING
Scale the screen
Note
H position, v position, phase and frequency for the screen can be adjusted in Analog mode only.
Advanced Menu (refer to page 22,23)
COLOR
Adjust the color temperature for the screen
USER RED
Adjust the level of red for the screen
USER GREEN
Adjust the level of green for the screen
USER BLUE
Adjust the level of blue for the screen
Pip(picture in picture) Menu (refer to page 24-28)
SIZE
Select the size of pip
POSITION
Select the position of pip
SOURCE
Change the input signal
BRIGHTNESS
Adjust the brightness of pip
CONTRAST
Adjust the contrast of pip
COLOR
Adjust the color of pip
TINT
Adjust the tint of pip
SHARPNESS
Adjust the sharpness of pip
Note
BRIGHTNESS, CONTRAST, COLOR, TINT and SHARPNESS for pip can be adjusted when inputting Composite Video or S-Video signal and also selecting [small] or [medium] or [large] in [size] menu.
13
LCD Monitor Instructions
Adjustment Items
Adv pip(Advanced picture in picture) Menu (refer to page 29,30)
H POSITION
Select the horizontal position of pip
V POSITION
Select the vertical position of pip
VIDEO FORMAT
Select the video format (ntsc/pal/secam)
Options Menu (refer to page 31-33)
OSD
Select the osd position
ROTATION
Select PORTRAIT or LANDSCAPE
OSD TIMEOUT
Change the osd timeout
OSD BACKGROUND
Select the osd background
LANGUAGE
Select language used in osd
BACKLIGHT
Adjust the backlight of the screen
Utilities Menu (refer to page 34,35)
AUTO ADJUST
Adjust the screen automatically
RESET
Delete the data saved at the current display mode
INTERNAL FIRMWARE
Display the osd version
RESOLUTION
Display the resolution of the screen
Note
Adv pip Menu can be used when inputting Composite Video or S-Video signal and also selecting [small] or [medium] or [large] in [size] menu.
Note
If selected [Rotated] in Options menu, [Internal Farmware] is not displayed.
14
LMU-TK40D2
Mode
You can change or indicate the signal input type following the steps.
Change or indicate the input signal
1.
While the OSD (On Screen Display) is not displayed, it is possible to change or indicate the current mode.
Press [Source] key to indicate the current mode in the lower right corner of the screen.
Analog RGB1
Mode: 88
1024 x 768 / 75 Hz
(Ex.)
2. While displaying the current mode, press [Source] key again.
Start searching another mode according to the order [Analog RGB1] / [Analog RGB2] / [Digital RGB].
[Analog RGB1] / Switch to the signal from RGB connector. [Analog RGB2] / Switch to the signal from R/G/B/HD/VD connector. [Digital RGB] / Switch to the signal from DVI connector.
Every time the input signal is searched, display the searched and stop searching picture.
The current mode is indicated for each input signal type as follows:
Analog RGB1
Mode: 88
1024 x 768 / 75 Hz
Digital RGB
Mode: 88
1024 x 768 / 75 Hz
Analog RGB2
Mode: 88
1024 x 768 / 75 Hz
In case there is no signal when the screen is on, the screen will be in the waiting mode and nothing is shown.
NOTE
15
LCD Monitor Instructions
Adjustment Procedure
1
Display the Windows or other screen
After a computer is connected with this LCD monitor, activate a computer and then shows a bright screen on this LCD monitor. It might not be possible to adjust the screen correctly for a dark screen.
For DOS mode, run an application that shows the edges of the screen (edit etc.) to adjust screen.
Before Adjustment
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
50
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
-
+
1056
Frequency
-
+
Scaling Wide
Show OSD (On Screen Display) menu
Press [ Menu] or [Menu ] key to show the following menu while no menu is displayed on the monitor.
2
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
50
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
-
+
1056
Frequency
-
+
Scaling Wide
Select item of the menu
Press [ ] or [ ] key to select item of the menu while displaying the OSD menu.
3
The signal timing for a computer which this LCD monitor supports is listed in "Table of Preset Data" on Page 39, the recommended value of Vertical Frequency for this model is 60Hz. (Unlike CRT Monitors, the display becomes stable when Vertical Frequency is low.) It is recommend to set Vertical Frequency of a computer connected at 60Hz by "refresh rate setting" before starting adjustment procedure. *This user's guide illustrates the OSD(On Screen Display) when installing this LCD
monitor in the standard direction. If selects the "Rotated" in Options menu (see page
31), OSD menu is displayed in the opposite order. This monitor does not have the convertible function of Landscape display. When using this monitor with vertical installation, it is necessary to adapt the input signal to this monitor to the Portrait display.
16
LMU-TK40D2
Move the cursor to Sub menu
After Main menu item is selected, press [Menu ] key.
Press [ Menu] key to return to Main menu from Sub menu.
4
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
25
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
-
+
1056
Frequency
-
+
Scaling Wide
Select item of Sub menu
Press [ ] or [ ] key as well as the Main menu item selection.
5
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
Sub menu
(Ex.)
User red
-
+
User green
-
+
User blue
-
+
Color
Warm Neutral Cold user
Match the cursor to the operation item
6
1. When there are some selections like "color" item, press [ ] or [ ] key to
move the cursor to switch.
*Continued on the following page.
Brightness
Contrast
H position
V position
Phase
Frequency
Scaling Wide
(Ex.)
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
-
25
-
50
-
50
-
50
-
15
-
1056
Sub menu
+
+
+
+
+
+
17
LCD Monitor Instructions
Adjustment Procedure
Adjustment or Setting
7
For each item selected, the adjustment/setting has been made by pressing [ ] and/or [ ] key. This monitor saves adjusted value at intervals of about 5 seconds. Do not turn off the monitor for at least 5 seconds after adjustment or setting. (The detail steps for each item are described in the page 18-35)
2. For the adjustment item like "brightness", press [] or [] key to change
levels of selected item.
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
25
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
-
+
1056
Frequency
-
+
Scaling Wide
18
LMU-TK40D2
(Picture Menu)
A. Picture Menu
Adjust the brightness
1
1. Select [Picture] on the Main menu and press [Menu ] key.
You can see the cursor moving to the Sub menu.
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
25
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
-
+
1056
Frequency
-
+
Scaling Wide
2. Select [Brightness] on the Sub menu with pressing [ ] or [ ] key.
The selected item of [Brightness] turns blue.
3. Use [ ] and/or [ ] key to adjust. (Interval: 0~100)
By pressing [ ] key, the whole screen is brighter. By pressing [ ] key, the whole screen is darker.
Adjust the contrast
2
1. Select [Picture] on the Main menu and press [Menu ] key.
You can see the cursor moving to the Sub menu.
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
25
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
1056
-
+
Frequency
-
+
Scaling Wide
If you wish to adjust the screen finely or in case the result adjusted by Auto Adjust (see page 34) sequence is not sufficient enough, adjust the screen manually.
Manual Adjustment
2.
Select [Contrast] on the Sub menu with pressing [ ] or [ ] key.
The selected item of [Contrast] turns blue.
*Continued on the following page.
Adjustment for computer screen
19
LCD Monitor Instructions
Adjustment Procedure(Picture Menu)
3. Use [ ] and/or [ ] key to adjust. (Interval: 0~100)
By pressing [ ] key, the contrast (difference between bright and dark) becomes darker. By pressing [ ] key, the contrast (difference between bright and dark) becomes lighter.
Adjust the horizontal position (Analog mode only)
3
1. Select [Picture] on the Main menu and press [Menu ] key.
You can see the cursor moving to the Sub menu.
2. Select [H position] on the Sub menu with pressing [ ] or [ ] key.
The selected item of [H position] turns blue.
3. Use [ ] and/or [ ] key to adjust. (Interval: 0~100)
Press [ ] to shift the screen to the right. Press [ ] to shift the screen to the left.
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
25
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
1056
-
+
Frequency
-
+
Scaling Wide
Adjust the vertical position (Analog mode only)
4
1. Select [Picture] on the Main menu and press [Menu ] key.
You can see the cursor moving to the Sub menu.
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
25
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
1056
-
+
Frequency
-
+
Scaling Wide
20
LMU-TK40D2
Adjustment for computer screen
3. Use [ ] and/or [ ] key to adjust. (Interval: 0~100)
Press [ ] key to shift the screen to the top. Press [ ] key to shift the screen to the bottom.
2. Select [V position] on the Sub menu with pressing [ ] or [ ] key.
The selected item of [V position] turns blue.
Adjust the phase (Analog mode only)
5
3. Use [ ] and/or [ ] key to be able to display the small characters
clearly. (Interval: 0~31)
1. Select [Picture] on the Main menu and press [Menu ] key.
You can see the cursor moving to the Sub menu.
2. Select [Phase] on the Sub menu with pressing [ ] or [ ] key.
The selected item of [Phase] turns blue.
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
25
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
1056
-
+
Frequency
-
+
Scaling Wide
Adjust the frequency (Analog mode only)
6
1. Select [Picture] on the Main menu and press [Menu ] key.
You can see the cursor moving to the Sub menu.
2. Select [Frequency] on the Sub menu with pressing [ ] or [ ] key.
The selected item of [Frequency] turns blue.
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
25
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
1056
-
+
Frequency
-
+
Scaling Wide
*Continued on the following page.
21
LCD Monitor Instructions
Adjustment Procedure(Picture Menu)
3. Use [ ] and/or [ ] key to adjust.
By pressing [ ] key, the horizontal width becomes wider. By pressing [ ] key, the horizontal width becomes narrower.
Adjust the scaling
7
1. Select [Picture] on the Main menu and press [Menu ] key.
You can see the cursor moving to the Sub menu.
2. Select [Scaling] on the Sub menu with pressing [ ] or [ ] key.
The selected item of [Scaling] turns blue.
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
(Ex.)
Sub menu
Brightness
25
-
+
Contrast
50
-
+
H position
50
-
+
V position
50
-
+
Phase
15
1056
-
+
Frequency
-
+
Scaling Wide
3. Use [ ] and/or [ ] key to adjust.
When pressing [ ] key, the scaling can be selected according to the order [Wide] / [Normal] / [1:1] / [Wide] in sequence. When pressing [ ] key, the scaling order is scrolled in opposite to the above order.
[Wide] / Display the input picture to the full wide. [Normal] / Display the input picture with keeping an aspect
ratio on the whole screen.
[1:1] / Display the input picture with the aspect ratio 1:1. The screen varies due to the selected resolution settings of connected PC system.
22
LMU-TK40D2
(Advanced Menu)
Adjustment for computer screen
Adjust the color temperature (Preset)
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
Sub menu
(Ex.)
User red
-
+
User green
-
+
User blue
-
+
Color
Warm Neutral Cold user
1
1. Select [Advanced] on the Main menu and press [Menu ] key.
You can see the cursor moving to the Sub menu.
2. Select [Color] on the Sub menu with pressing [ ] or [ ] key.
The selected item of [Color] turns blue.
B. Advanced Menu
You can adjust the color temperature for the screen manually. Three preset values of color temperature are set up at the time of factory shipments. Besides, you can set your preferable values.
3. Use [ ] and/or [ ] key to adjust.
<Preset value> <Screen condition>
Warm / a little reddish white Neutral / natural light Cold / a little bluish white
Adjust the color (User)
2
If you wish to set user setting of color, follow the steps.
(Ex.) In case adjusting the [User red], [User green] and [User blue] in sequence.
1. Select [Advanced] on the Main menu and press [Menu ] key.
You can see the cursor moving to the Sub menu.
When pressing [ ] key, the color temperature can be selected to the order [Neutral] / [Cold] / [user] / [Warm] / [Neutral] in sequence. When pressing [ ] key, the color temperature order is scrolled in opposite to the above order.
If [user] is selected, three colors adjustment menu to adjust [User red] or [User green] or [User blue] are available (see following step
2).
23
LCD Monitor Instructions
Adjustment Procedure(Advanced Menu)
Picture
Advanced
Pip
Adv pip
Options
Utilities
Main menu
Sub menu
(Ex.)
User red
-
+
User green
-
+
User blue
-
+
Color
Warm Neutral Cold user
2. Select [Color] on the Sub menu with pressing [ ] or [ ] key.
The selected item of [Color] turns blue.
3. Select [User] with [ ] and/or [ ] key.
[user] turns red. Besides, [User red], [User green] and [User blue] are displayed.
4. Select [User red] with [ ] key.
The selected item of [User red] turns blue.
5. Adjust the red level with [ ] and/or [ ] key. (Interval: 0~100)
User red
User green
User blue
pressing [ ] key
more reddish
more greenish
more bluish
pressing [ ] key
less reddish
less greenish
less bluish
6. Press [ ] key.
You can see the cursor moving to [User green]. The selected item of [User green] turns blue.
7. Adjust the green level with [ ] and/or [ ] key. (Interval: 0~100)
And then press [ ] key.
You can see the cursor moving to [User blue]. The selected item of [User blue] turns blue.
8. Adjust the blue level with [ ] and/or [ ] key. (Interval: 0~100)
Loading...