Sanyo CL3632, XS3632, C3632 User Manual 2

Specifications and Main Features

  • Model Number: Indoor Unit XS3632, Outdoor Unit C3632 - Power Source: 230 - 208 V / 1 Phase / 60 Hz - Cooling Capacity: - BTU/h: Indoor Unit 36,000,Outdoor Unit 35,000 - kW: Indoor Unit 10.55, Outdoor Unit 10.26 - Air circulation (High): Indoor Unit 980 cu.ft/min, Outdoor Unit 880 cu.ft/min - Moisture removal (High): 11.9 Pints/h - Electrical Ratings: - Voltage Export: Indoor Unit 230 V, Outdoor Unit 208 V - Voltage Range: 187 - 253 V - Running Amperes: Indoor Unit 15.4 A, Outdoor Unit 16.0 A - Maximum Running Amperes: I unit 18.0 A, O unit 19.3 A - Power Input: Indoor and Outdoor Units 3440 W and 3250W - Power factor 97% I unit and 98% O unit - S.E.E.R: Indoor 10.8 BTU/Wh, Outdoor 11.0 BTU/Wh - Starting Amperes: Indoor cage 97.9 A, Outdoor Unit cage 88.8 A - max fuse size 35 A - Features: - Controls Microprocessor: Controlled - Timer: 24 hours & Programmable ON/OFF - Fan speed: 3 speed indoor / 2 speed outdoor (Auto) - Air deflection: Horizontal / Vertical (automatic ) - Air filter: Washable type, simple to access - Remote controller: RCS-5PS4U (Optional)
  • Capillary Tube aids the refrigerant control while the refrigerant tubing connections are Flares.
  • Starting from a ¾ " trade size and 9-27/32 inch over the drain connection is the maximum head of the drain pump while it is rotary for the Compressor.
  • The recommended sound levels provide great comfort as the Indoor sound levels Hi Me and Lo are 43 - 40 and 36dB while the outdoor level is moderate at 56dB.
  • For ease of understanding, the limit of tubing length for shipment is 50 ft or 15 m while the baseline is 165 ft or 50 m. While performing circulation the indoor unit being placed lower than the outdoor unit results in a difference of 100 ft or 30m while 165 ft or 50 m avoids the opposite situation.
  • The broad tube has a diameter of ¾ inches while a narrow tube has an external diameter of 3.76 cm. R22 is shipped in substantial amounts, ranging from 9.48 pounds to 4.3 kilograms.
  • The indoor unit weighs 60 lbs which is around 27 kg while the outdoor unit weighs 90 kg or 198 lbs.

Alone, the dimensions are 11-1/32 x 280.76 cm x 94.22 cm and 137.16 cm x 35.56 cm x 92.48 cm which can also be recorded as a HxWxD ratio for the compression of the masses.

  • The larger outdoor units are 40" while the indoor units are 32-25/32 which accounts to 43-27/32.

(1,016 mm)perspiration,making its dimensions 230 -208 V, 1 phase. The frequency of the machine is pegged at 60 Hz

Any cool system design changes will be communicated with proper prior notice.

Frequently Asked Questions

  • Q: What is the power source for the Sanyo air conditioner?

A: The power source is 230 - 208 V 1 Phase 60 Hz

  • Q: What is the cooling capacity of the indoor and outdoor units?

A: The indoor unit has a cooling capacity of 36 000 BTU/h while the outdoor unit has 35 000 BTU/h

  • Q: What is the maximum fuse size for this unit?

A: The maximum fuse size is 35 A.

  • Q: Is there a remote controller that is provided with the installation of this unit?

A: Yes, it comes with an RCS - 5PS4U remote controller which is an accessory.

  • Q: What Type of refrigerant is used in the said unit system?

A: The unit uses R22 refrigerant

  • Q: The sound inside the unit is usually at what level?

A: The sound levels of operation is at a high of 43 db-A at the medium the sound level is at 40db-A while at low it is at 36 db-A

  • Q: Is the filter for air washable?

A: As earlier said the air filter is made for easy washing.

  • Q: Can you give us the weight of the indoor unit?

A: The weight of the indoor unit is measured to be 60 lbs (27 kg).

  • Q: Describe the maximum elevation distance between the indoor and outdoor units while maintaining proper function.

A: The maximum elevation distance is 165 ft (50 m) for instances when the outdoor unit is placed above the indoor unit and 100 ft (30 m) for when it is placed below.