INDOOR MODEL No.PRODUCT CODE No.OUTDOOR MODEL No.PRODUCT CODE No.
KS2462R854 019 00
Indoor UnitOutdoor Unit
C2462R854 019 01
CL2462R854 019 02
FILE NO.
854648419200
KS2462RC2462R
CL2462R
REFERENCE NO. SM830092
– 1 –
SM830092
Important
Please Read Before Starting
This air conditioning system meets strict safety and operating
standards. As the installer or service person, it is an important
part of your job to install or service the system so it operates
safely and efficiently.
For safe installation and trouble-free operation, you must :
Carefully read this instruction booklet before beginning.
Follow each installation or repair step exactly as shown.
Observe all local, state, and national electrical codes.
Pay close attention to all warning and caution notices
given in this manual.
This symbol refers to a hazard or
unsafe practice which can result in
severe personal injury or death.
This symbol refers to a hazard or
CAUTION
unsafe practice which can result in
personal injury or product or
property damage.
If Necessary, Get Help
These instructions are all you need for most installation sites
and maintenance conditions. If you require help for a special
problem, contact our sales/service outlet or your certified dealer
for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for improper
installation or maintenance service, including failure to follow
the instructions in this document.
SPECIAL PRECAUTIONS
When Wiring
……………………………………………………………………
ELECTRICAL SHOCK CAN CAUSE SEVERE
PERSONAL INJURY OR DEATH. ONLY A
QUALIFIED, EXPERIENCED ELECTRICIAN
SHOULD ATTEMPT TO WIRE THIS SYSTEM.
• Do not supply power to the unit until all wiring and tubing are
completed or reconnected and checked.
• Highly dangerous electrical voltages are used in this system.
Carefully refer to the wiring diagram and these instructions
when wiring. Improper connections and inadequate grounding can cause accidental injury or death.
• Ground the unit following local electrical codes.
• Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
When Transporting
……………………………………………………………………
Be careful when picking up and moving the indoor and outdoor
units. Get a partner to help, and bend your knees when lifting to
reduce strain on your back. Sharp edges or thin aluminum fins
on the air conditioner can cut your fingers.
When Installing
……………………………………………………………………
…In a Room
Properly insulate any tubing run inside a room to prevent
“sweating” that can cause dripping and water damage to walls
and floors.
…In Moist or Uneven Locations
Use a raised concrete pad or concrete blocks to provide a
solid, level foundation for the outdoor unit. This prevents water
damage and abnormal vibration.
…In an area with High Winds
Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.
…In a Snowy Area (for Heat Pump-type Sys-tems)
Install the outdoor unit on a raised platform that is higher than
drifting snow. Provide snow vents.
When Connecting Refrigerant Tubing
……………………………………………………………………
• Ventilate the room well, in the event that refrigerant gas
leaks during the installation. Be careful not to allow contact
of the refrigerant gas with a flame as this will cause the
generation of poisonous gas.
• Keep all tubing runs as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the
flare and union tubes before connecting them, then tighten
the nut with a torque wrench for a leak-free connection.
• Check carefully for leaks before starting the test run.
NOTE
Depending on the system type, liquid and gas lines may be
either narrow or wide. Therefore, to avoid confusion the
refrigerant tubing for your particular model is specified as either
“narrow” or “wide” rather than as “liquid” or “gas”.
When Servicing
……………………………………………………………………
• Turn the power OFF at the main power box (mains) before
opening the unit to check or repair electrical parts and
wiring.
• Keep your fingers and clothing away from any moving parts.
• Clean up the site when installation is finished. Check that no
metal scraps or bits of wiring have been left inside the unit.
CAUTION
• Ventilate any enclosed areas when installing or testing the
refrigeration system. Contact of refrigerant gas with fire or
heat can produce poisonous gas.
• Confirm after installation that no refrigerant gas is leaking. If
the gas comes in contact with a burning stove, gas water
heater, electric room heater or other heat source, it can
cause the generation of poisonous gas.
– 2 –
SM830092
Table of Contents
1.OPERATING RANGE ....................................................................................... 4
(2) A Sensor is Defective................................................................................ 50
(3) Checking the Electrical Components ........................................................ 51
– 3 –
SM830092
1. OPERATING RANGE
KS2462R / C2462R
TemperatureIndoor Air Intake Temp.Outdoor Air Intake Temp.
Maximum95 °F DB / 71 °F WB115 °F DB
Minimum67 °F DB / 57 °F WB 67 °F DB
KS2462R / CL2462R
TemperatureIndoor Air Intake Temp.Outdoor Air Intake Temp.
Maximum95 °F DB / 71 °F WB115 °F DB
Minimum67 °F DB / 57 °F WB 0 °F DB
– 4 –
SM830092
2. SPECIFICATIONS
1-1 Unit Specifications
MODEL No.Indoor Unit
Outdoor UnitC2462R
POWER SOURCE230 - 208 V / 1 Phase / 60 Hz
PERFORMANCECooling
Capacity
Air circulation (Hi)
Moisture removal (High)Pints / h6.5
ELECTRICAL RATINGS
Voltage ratingVAC
Available voltage range187 – 253
Running amperes*A10.2
Max. running amperes**A12.5
Power inputW2,240
Power factor%95.5
S.E.E.R13.0
Max. starting amperesA61
FEATURES
ControlsMicroprocessor
TimerON/OFF 24-hours & Program
Fan speed Indoor / Outdoor3 and Automatic control / 2 (Auto)
Air deflectionHorizontal / Vertical– / Automatic
Air filterWashable, easy access
Remote controller (Accessory)RCS - 1PS4U - G
Refrigerant controlCapillary tube
Refrigerant tubing connectionsFlare type
CompressorScroll
Operation sound
REFRIGERANT TUBING
Limit of tubing lengthft. (m)
Limit of tubing length at shipment23 ( 7 )
Limit of elevation difference
between the two units
Refrigerant tubeNarrow tube3 / 8 (9.52)
outer diameterWide tube3 / 4 (19.05)
Refrigerant amount at shipmentlbs. (kg)R410A - 6.6 (3)
DIMENSIONS & WEIGHTIndoor unitOutdoor unit
Unit dimensionsHeightin. (mm)
Package dimensionsHeight
Net weightlbs. (kg)
Shipping weight
Shipping volume
Cooling:
Rating conditions (*): Indoor air temperature 80 °F DB / 67 °F WB, Outdoor air temperature 95 °F DB / 75°F WB
Full load conditions (**):Indoor air temperature 80 °F DB / 67 °F WB, Outdoor air temperature 115°F DB
POWER SOURCE230 - 208 V / 1 Phase / 60 Hz
PERFORMANCECooling
Capacity
Air circulation (Hi)
Moisture removal (High)Pints / h6.5
ELECTRICAL RATINGS
Voltage ratingVAC
Available voltage range187 – 253
Running amperes*A10.2
Max. running amperes**A12.5
Power inputW2,240
Power factor%95.5
S.E.E.R13.0
Max. starting amperesA61
FEATURES
ControlsMicroprocessor
Timer1-hour OFF, ON/OFF 12-hours & Program
Fan speed Indoor / Outdoor3 and Automatic control / 3 (Auto)
Air deflectionHorizontal / Vertical– / Automatic
Air filterWashable, easy access
Remote controller (Accessory)RCS - 1PS4U - G
Refrigerant controlCapillary tube
Refrigerant tubing connectionsFlare type
CompressorScroll
Operation sound
REFRIGERANT TUBING
Limit of tubing lengthft. (m)
Limit of tubing length at shipment23 ( 7 )
Limit of elevation difference
between the two units
Refrigerant tubeNarrow tube3 / 8 (9.52)
outer diameterWide tube3 / 4 (19.05)
Refrigerant amount at shipmentlbs. (kg)R410A - 6.6 (3)
DIMENSIONS & WEIGHTIndoor unitOutdoor unit
Unit dimensionsHeightin. (mm)
Package dimensionsHeight
Net weightlbs. (kg)
Shipping weight
Shipping volume
Cooling:
Rating conditions (*): Indoor air temperature 80 °F DB / 67 °F WB, Outdoor air temperature 95 °F DB / 75°F WB
Full load conditions (**):Indoor air temperature 80 °F DB / 67 °F WB, Outdoor air temperature 115°F DB