Sanyo VW-SF10CA - Professional Air Purification System, Air Washer Plus VW-SF10CA Brochure & Specs

Page 1
VW-SF10CA
Natural decline
Natural of airborne bacteria (particles/100 liters)
Operating time (minutes)
Space purification system (Air washer plus with Disinfectant Element)
0
51015202530
10
1
10
2
10
3
10
4
10
5
10
6
10
7
More than
99.9%
of the
airborne bacteria
removed after
5
minutes
Suppresses airborne bacteria and allergens by the power of water.
Suppresses airborne bacteria and allergens by the power of water.
Verified through U.S. and other global independent testing institutions.
Professional use
VW-SF10CA
air purification system
Air Washer Plus™
Supresses airborne bacteria and allergens by the power of water.
Page 2
Controls airborne viruses and pollen eveninlarge spaces. Keeps your air clean through the power of water.
Bacteria
Mold
Pollen Germs
Disinfects
No disinfectant element
100
10
7
10
6
10
5
10
4
10
3
10
2
10
1
90
80 70
60 50
40
30
20
10
0
After passing through the
disinfectant element
1
0 5 10 15 20 25 30
Natural decline
Space purification system (Air Washer
with Disinfectant Element)
Natural decline
Using the air space purification system
*5-minute operating time
Photograph
after culturing
Operating time (minutes)
Verified through academic research by the Gunma Prefecture Institute of Health and other public health institutes. [Test result 1] Airborne germs 99.9% reduction*1 [Test result 2] Airborne germs 98% reduction
*2
*1 Air containing germs was passed through the electrolyzed-water disinfectant element, and the germs were collected. Their infectious capacity was then measured with embryonated egg cultures. Test institute: Tottori University *2 An actual unit (Air Washer with Disinfectant Element) was operated in a 9-square-meter laboratory, where a germs solution was sprayed into the air for 30 minutes. Fifty minutes after the spraying was stopped, the germs were collected, and their infectious capacity was measured with cultured cells. Test institute: The Kitasato Institure Research Center for Medical Environment
99
% reduction
95
% reduction
99
% reduction
97
% reduction
Airborne mold
Disinfectant effect
Dust mite feces and shellsPollen
Allergen control
Speedy deodorization
of tobacco odor
*7
,
pet odors
*8
, and others.
Deodorizing effect
SANYO's electrolyzed water technology is already at work in swimming pool sterilization systems and in SANYO's zero-detergent cycle washing machines. Now this same virus washer technology has been used to create an air purification system that is capable of using the 'power of water' to clean the air in large spaces where people gather. This system removes airborne viruses, bacteria and mold, as well as pollen, dust mite feces and shells, and removes odors caused by tobacco and pets.
SANYO Electrolyzed Water Technology
Deformation and decomposition of membrain proteins
More than 99.9% of the airborne bacteria removed after 5 minutes
Electrolyzed water works in several ways to help purify air
Viruses have
infected the cell
Purified cells
Test method: Air containing suspended germs is passed through the disinfectant element containing electrolyzed water, after which the remaining airborne germs were trapped and residual germ populations were evaluated in cell cultures by TCID50 assay. Testing organization: Gunma Prefectural Institute of Public Health
*3: Testing method: Mold particles were suspended in an approximately 9-cubic-meter test chamber and disinfectant electrolytic mist was released into the chamber. An air sampler was used to evaluate the number of residual airborne mold particles. Testingorganization: Japan Food Research Laboratories *4: Testing method: Disinfectant electrolytic mist was released into a 0.275-cubic-meter test chamber containing pollen particles, and the reduction in the number of pollen particles was evaluated by the enzyme antibody method. Testing organization: Osaka Medical College *5: Test method: Disinfectant electrolytic mist was released into a 0.275-cubic-meter test chamber containing dust mite particles, and the reduction in the number of dust mite particles was evaluated by the enzyme antibody method. Testing organization: Kobe University School of Medicine *6: Test method: Disinfectant electrolytic mist was released into a 0.275-cubic-meter test chamber containing dog and cat dander allergens, and the reduction in the number of dander allergens was evaluated by the enzyme antibody method (ELISA). Testing organization: Oriental Yeast Co., Ltd. *7: Test method: Three gases with different odors (acetaldehyde, acetic acid, and ammonia) were released into a 0.275-cubic-meter test chamber and then passed through a disinfectant element. The percentage of residual gas was then measured. Testing organization: SANYO Electric * 8: Test method: Four gases with different odors (ammonia, acetic acid, trimethylamine and methyl mercaptan) were released into a 0.275-cubic-meter test chamber and then passed through a disinfectant element. The percentage of residual gas was then measured. Testing organization: SANYO Electric
Test method: Bacteria were suspended in a 2-cubic-meter test chamber and the air purification system (Air Washer with Disinfectant Element) was operated. Microbes remaining in suspension were trapped periodically and the change over time was evaluated by the pour plate method. Testing organization: Gunma Prefectural Institute of Public Health together with SANYO Electric.
*3 *4 *5 *6
Residual viability of germs in the disinfectant element’s electrolyzed water (%)
Number of airborne bacteria (particles/ 100 liters)
Dandruff from dogs or cats
Airborne bacteria disinfectant test results
More than 99% of airborne germs were removed after one passage through the disinfectant element.
The hypochlorous acid and hydroxyl radicals in the electrolyzed water destroys the germ’s
membrane proteins effectively inactivating it.
Suppresses viruses
The Air Washer is based on electrolyzed water technology developed by SANYO. This system electrolyzes tap water containing chloride ions to generate hypochlorous acid and hydroxyl radicals, which are two different types of active oxygen species that suppress germs. Maintaining a high concentration of these active oxygen species in the electrolyzed filtration water effectively fights microbes.
Mechanism of germ suppression by electrolyzed water
Effectively suppresses airborne germs and allergens
A double punch using two different agents that are very effective in purifying air, hypochlorous acid and hydroxyl radicals,
rapidly suppresses and sterilizes infectious agents and removes odors.
The disinfectant element inside the unit suppresses germs and bacteria.
Germs suppression test results
Deodorizes
Odors
HC10
HC10
HC10
HC10
HC10
HC10
OH
OH
OH
OH
OH
OH
Membrane protein
Hydroxyl radical
Electrolyzed water
Electrolyzed water
Membrane protein damage
Photo of cells
after cultivation
No disinfectant
element
After passing through
the disinfectant element
Viruses have
infected the cell
Cell protein
Hypochlorous acid
Inactive germ
Controls airborne viruses and pollen eveninlarge spaces. Keeps your air clean through the power of water.
Bacteria
Mold
Pollen Germs
Disinfects
SANYO's electrolyzed water technology is already at work in swimming pool sterilization systems and in SANYO's zero-detergent cycle washing machines. Now this same virus washer technology has been used to create an air purification system that is capable of using the 'power of water' to clean the air in large spaces where people gather. This system removes airborne viruses, bacteria and mold, as well as pollen, dust mite feces and shells, and removes odors caused by tobacco and pets.
SANYO Electrolyzed Water Technology
Suppresses germs
The Air Washer is based on electrolyzed water technology developed by SANYO. This system electrolyzes tap water containing chloride ions to generate hypochlorous acid and hydroxyl radicals, which are two different types of active oxygen species that suppress germs. Maintaining a high concentration of these active oxygen species in the electrolyzed filtration water effectively fights microbes.
Deodorizes
Odors
Safely and effectively purifies over 20,000 cu.ft. per hour of indoor air.
SANYO’s Electrolyzed Water technology transforms ordinary tap water to safely remove up to 99% of germs, bacteria, dust particles, allergens, odors, smoke, molds, and VOC’s (volatile organic compounds) without generating any harmful ozone.
SANYO’s Electrolyzed Water Technology protects your loved ones from polluted air.
Protect your employees, students, customers and families from airborne contaminants, reducing sick days, lower productivity, unemployment insurance and medical costs.
Good for the Air. Good for your Environment.
No harmful chemicals used during the purification process. In addition, the SANYO Air Washer Pro does not release any harmful ozone into the environment.
Time-tested and Proven Technology
Electrolyzed water has been used for years in industries such as food processing, water sterilization, hospital and laboratory use. SANYO’s technology has been verified by independent third party testing facilities and has been industry-proven for over 20 years.
Page 3
Intake air
Purified air
Supplied pre-filter +
high-efficiency filter
The pre-filter works with the high-efficiency filter to increase effectiveness against pollen and to prevent clogging of the disinfectant element by dust and other particles. A high­performance micro-particle filter (purchased separately) capable of trapping finer pollen and dust particles is also available.
Auto louver
The louver opens when the unit is turned on, and closes when it is turned off, to prevent dust from entering. When the airflow direction is adjusted, the position is automatically stored in memory. The louver swings in a range of 0 to 23 degrees.
TREATED AIR VOLUME Indicator
Control panel
Includes a child lock function to prevent children from tampering with the system.
1.5 gallon water supply tank
The tank allows about 10 hours of use at the standard airflow. A lamp lights and an alarm sounds to indicate when the water needs to be replenished.
Automatic salt water dispenser
Provides a 6 month supply of salt water which is automatically added in the electrolyzing process.
Humidity control
SANYO believes in a Think GAIA vision. We set our sights on the invisible - the air for the health of the children and future generations.
Controls airborne germs by circulating electrolyzed water through the disinfectant element. Indoor air is then actively passed through the element “washing” away airborne pathogens and other toxins.
Quickly and powerfully purifies air in spaces as large as 1050 sq.ft.
More than 99%
reduction in germs after
a single passage through
the element.
Disinfectant element
One LED lights for each 10,600 cu.ft. of air that has been purified. (Displays in 5 steps, and returns to zero when the unit is turned off.)
Pre-filter
high-efficiency filter
Allows about 10 hours of
continuous operation.
Adjusts the airflow direction and
prevents dust intake.
Sensors and variable airflow
controls prevent over-humidification.
Clog-resistant honeycomb
Indicates the treated air volume.
Trap pollen and house dust.
Simplifies water drainage.
Simple and easy to use.
VW-SF10CA
From 215 to1050 square feet
Humidification
Deodorizes
Disinfects
Suggested
room size
Suppresses germs
Disinfectant element method
Airborne germs are suppressed by circulating air through an element containing electrolyzed water.
Applications
s#OMMERCIAL/FFICE0RIVATE3ECTOR"UILDINGS s(OMES2ESIDENTIAL5SE s-UNICIPAL'OVERNMENT"UILDINGS s3CHOOLS5NIVERSITIES s!IRPORTS4RANSPORTATION4ERMINALSAND(UBS s(OSPITALS#LINICSAND0HARMACIES s#ONVENTION#ENTERSAND/UTDOOR6ENUES s2ETAIL3TORES s(OTELS s$ORMSAND!PARTMENT#OMPLEXES
SANYO’s electrolyzed water technology is already at work in swimming pool sterilization systems and in SANYO’s zero­detergent cycle washing machines. Now this same air washer plus technology has been used to create an air purification system that is capable of using the ‘power of water’ to clean the air in large spaces where people gather. This sytem removes airborne germs, bacteria and mold, as well as removes odors, smoke, VOC’s, pollen and allergens caused by tobacco and pets.
Page 4
22.8 11.7
31.1
Chain fastening location
Saline solution tank
(Unit: inch)
Water supply/drain tank unit
Intake filter
Water supply/drain tank unit panel
Bacteria Washer element
Electrical component box
Front lower panel
Front upper panel
Display
Control section panel
Outlet (Automatic louver)
Chain fastening location
Handle
Chain fastening location
VW-SF10CA
Specifications
Model
Power source Single-phase, AC 110/120 V, 60Hz
H 31.1 x W 22.8 x D 11.7
Outer dimensions inch
73
1050
Front panel: White (N8.5)
Side panel: Gray (N4.0)
Ibs.
93
(when water supply and saline tanks are full)
Ibs.
HIGH: 350, MEDIUM: 175, LOW: 70
CFM
HIGH: 49, MEDIUM: 36, LOW: 29
*1
dB (A)
HIGH: 118, MEDIUM: 57, LOW: 46
W
ft
2
Product weight
Operating weight
Exterior color (Munsell number)
Airflow volume
Operating noise
Power consumption
Suitable floor space (approximate)
VW-SF10CA
*1: Operating noise was measured in an anechoic chamber, and is the value at a position 3.3 ft in front
of the system and a height of 3.3 ft. The operating noise after actual installation is ordinarily louder than this value, due to surrounding noise, echoing, and other effects.
*2: The power consumption, amperage, rated airflow and operating noise in the powerful deodorizing
mode are the same as in the high mode.
Outlet (Automatic louver)
This is used to adjust the air direction.
Control section panel
Open this panel to access the control section.
Outlet filter Air purification element
Display
Air intake filter
Space Cleaning System
Water supply/drain tank unit panel
Water supply/ drain tank unit
Scale filter
Drain tube Air intake
Saline solution tank
Air purified by the electrolyzed water blows out.
Indoor air is taken in.
Indoor air is taken in.
Indoor air is taken in.
22.8 11.7
31.1
Chain fastening location
Saline solution tank
(Unit: inch)
Water supply/drain tank unit
Intake filter
Water supply/drain tank unit panel
Bacteria Washer element
Electrical component box
Front lower panel
Front upper panel
Display
Control section panel
Outlet (Automatic louver)
Chain fastening location
Handle
Chain fastening location
Water supply/drain tank unit panel
Water supply/ drain tank unit
Scale filter
Drain tube Air intake
Saline solution tank
Indoor air is taken in.
Space Cleaning System
VW-SF10CA
Outlet (Automatic louver)
This is used to adjust the air direction.
Control section panel
Open this panel to access the control section.
Outlet filter Air purification element
Display
Air intake filter
Space Cleaning System
Water supply/drain tank unit panel
Water supply/ drain tank unit
Scale filter
Drain tube Air intake
Saline solution tank
Air purified by the electrolyzed water blows out.
Indoor air is taken in.
Indoor air is taken in.
Indoor air is taken in.
Space Cleaning System
Distributed by:
Biomedical and Environmental Solutions Division
1300 Michael Drive, Suite A, Wood Dale, IL 60191 USA
SANYO North America Corporation
Toll Free USA 800-858-8442 • Fax 630-238-0074
us.sanyo.comLR-AWPlus-12.09
Loading...