Sanyo AD-2001KIT, AD-2000KIT User Manual

Auto Voice Dialer with Verification
The new AD series auto voice dialers are
designed for direct, immediate notification
of emergency situations using any regular
telephone line, cell phone or pager.
AD-2000KIT AD-2001KIT
AD-2001KIT
• Allows for two separate input alarm channels connected to unit(s) remote alarm contacts. (N.O./N.C. type)
• Can dial up to four regular telephones, cellular phones or pagers
Automatically redials unanswered or busy numbers. Ability to program the number of times messages will be repeated to each telephone number dialed. Number of dialing attempts is programmable as well.
Two Way Voice Verification
The 2-way voice verification feature allows the person called to listen in through the highly sensitive microphone or have a speakerphone conversation.
Universal Dial Tone (UDT)
The Exclusive Universal Dial Tone feature makes the AD-2000 series suitable for use worldwide. It also adapts to the ‘Voice Message Systems’ of AT&T as well as voice systems of other phone companies.
Memory
The AD-2001KIT and AD-2000KIT has EEPROM memory and will retain programming in the case of power outage.
Remote Turn Off
Called party may turn off activated channel while leaving other channels armed.
Line Seizure
Built in Line Seizure. Also plugs into standard telephone jack.
AD-2000KIT
• Allows for four separate input alarm channels connected to unit(s) remote alarm contacts. (N.O./N.C. type)
• Can dial up to eight regular telephones, cellular phones or pagers
www.sanyobiomedical.com
Specifications
AD-2000KIT AD-2001KIT
1) TELEPHONE NUMBERS: Up to 8 numbers may be stored in
EEPROM for dialing voice phones, numeric pagers and/or voice pagers. Each may be up to 50 digits long including multiple PAUSE segments. A PAUSE is 2 seconds long and counts as 1 digit.
2) FOUR INPUT CHANNELS (1-4): For dry contacts (N.O. or
N.C.) (see note below) may be programmed for: A: Exit delay (0-199 seconds)-individually programmed. B: Entry delay (0-199 seconds)-individually programmed. C: NO or NC operation-individually programmed. D: Momentary, continuous or disabled-individually programmed. E: Each input channel may be programmed to dial any or all numbers. F: PBX (PABX)-Same for all channels. G: TONE/PULSE dialing-Same for all channels. H: ATTEMPTS: Programmable 1 to 9 (applies to all numbers). Numbers are dialed sequentially from 1 to 9 times regardless if attempts to connect are successful or not.
3) THE FOLLOWING OUTGOING MESSAGE (OGM) OPTIONS ARE AVAILABLE:
A: No OGM. B: 1 OGM up to 51 seconds long. C: 2 equally long OGM segments (maximum 25.5 seconds/segment). D: ID segment plus equally split OGM1 and OGM2 periods. E: 3 equally long OGM segments (maximum 17 seconds.segment). F: ID segment plus equally split OGM1, OGM2, OGM3 periods. G: 4 equally long OGM segments (maximum 12.75 seconds/segment). H: ID segment plus equally split OGM1, OGM2, OGM3 and OGM4 periods.
Note: Maximum duration of the ID segment under options (D), (F)
and (H) is limited to 15 seconds, in which case the maximum length of each OGM is equally portioned so that the sum of OGMs and ID is 51 seconds. If less than 15 seconds is used for the ID, the available (maximum) time for OGM messages is automatically increased so that the sum of the OGMs and ID again is 51 seconds.
4) MESSAGE ALERT: Programmable 1 to 3 times. Note: The entire
message (e.g. ID followed by OGM1, OGM2,...) is played only once in the TEST mode.
5) EEPROM MEMORY: Voice messages, phone numbers and
dialer status information remain stored even after total power failure
.
8) TWO-WAY MODE: During the listen-in mode, the called party
may initiate the two-way conversation mode for minimum 60 seconds by pressing digit “2”. Anytime during the two-way mode, the 60-second period can be restarted by pressing “2” again, as many times as needed.
9) REMOTE SHUT OFF: While in listen-in or two-way mode the
called party may terminate the dialing process and deactivate the channel by pressing “#” twice within 1 second (touch-only). This activation effectively stops further dialing resulting from a continuously activated channel until it is fully restored, while leaving other channels active.
10) LINE SEIZURE: Internal switching relay and terminals are
provided to allow for line seizure hookup of incoming telephone line.
11) AUX ALARM: An open collector transistor circuit allows for
enternal devices like sirens, relays, etc. to be activated when any of the 4 channels are active. Current is limited to 500mA. Applied voltage must be less than 20VDC.
12) TEST MODE: The unit provides a convenient way to verify
phone numbers, dialing mode, OGMs and channel information, with or without hookup to an active phone line.
Note: In TEST mode all system parameters will appear on the LCD and
recorded messages will be played back through the internal speaker. In the operate mode the LCD screen is blanked out and voice messages will not be heard through the speaker.
13) POWER REQUIREMENTS: Supply voltage: 115V
Supplied with AC power adapter (model# PB12P) with 24 hour battery backup.
14) HOOKUP: Standard (RJ11) jacks on back for telephone line
connection. Terminal blocks are provided for main power, auxiliary power, input channels and line seizure hookup.
DIMENSIONS: 6” x 4” X 1.5” WEIGHT: 8oz.
- this product is manufactured by United Security Products
6) LCD NUMERIC DISPLAY: A 2-line by 16 character LCD panel is
used to display program, test and status information.
7) LISTEN-IN: The listen-in feature can be initiated by the called
party (touch-tone only) anytime during the OGM playback cycle by simply pressing “1”. This will start a minimum 60-second listening period that can be restarted by pressing “1” again, as many times as needed.
SANYO North America Corporation
1300 Michael Drive, Suite A, Wood Dale, IL 60191 USA
Biomedical and Environmental Solutions
Toll Free USA 800-858-8442 • Fax 630-238-0074
201 Creditview Road, Woodbridge, Ontario L4L 9T1
www.sanyobiomedical.com
SANYO Canada, Inc.
905-265-4100 • Fax 905-265-4101
LR-AD2000/1-11.09
Loading...