Split System Submittal Data
System: 12XS71 Indoor/Outdoor: XS1271/C1271
Grille: PNR-XS1872
Ceiling Recessed Air Conditioner
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data (at 115V)
Power V/PH/Hz 115/1/60
Circuit Ampacity
Fuse Size, Max.
Compressor DC Rotary Inverter
No. used
R.L. Amps - L.R.
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps
(A) 20
(A) 20
(A) 12.6-20
Propeller
15-3/4-1
DC Motor
(RPM) 8-750
(W) 50-1
(HIGH)) 1059
(A) 0.6
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
Outdoor Unit
R410A
2.43
Electric Expansion Valve
Flare
65
23
(in O.D. Dishcharge) 1/4”
(in O.D. Suction) 3/8”
(in.) H x W x D
(uncrated) 11-1/16 x 22-5/8 x 22-5/8
(crated) 11-13/32 x 24-13/16 x 28-1/8
(uncrated) 21-9/16 x 28-11/32 x 10-1/16
(crated) 23-5/8 x 33-11/16 x 14-1/4
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size
Aluminum Fin and Copper Pipe
Corrugated Plate-Inner Rifl ed
2-18.1
(sq.ft.)) 3.95
(in.) 5/16”
Turbo
12-5/8/5-3/4-1
3+Auto
(RPM, High)) 8-470
(W) 30-1
(Hi/Med/Low) 235/206/194
(Hi) (dB-A) 34
(A) .346
Aluminum Plate Fin & Copper Tube
Slit Plate & Inner Rifl ed
2-18.1
(sq.ft.)) 2.94
(in.) 9-32”
(in.) 23/32”
Weight Indoor Outdoor
Net
Shipping
Shipping Volume
Performance Data @ ARI Standard Conditions (115V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating
(lbs.) 35.3 77.2
(lbs.) 41.9 83.8
(cu.ft.) 4.59 6.35
(BTU/H) 11,900 (3,000-11,900)
(BTU/H) 7,200
(BTU/H) 4,700
(Pints/H) 4.26
(A) 12.6 (2.5-12.6)
(W) 1260 (250-1260)
(dB-A) 47
16
Dimensions
3. DIMENSIONAL DAT A
Indoor Unit XHS1271 & PNR-XS1872
XHS1872 & PNR-XS1872
6-5/16 6-11/16
1-3/16 (30)
4-19/32
1-25/32
1-25/32
2-3/32
8-15/32
22-5/8 (575)
11-5/32 (283)
3
6
5
Less than 31/32 Less than 31/32
3-5/8
22-5/8 (575)
12-7/8
Suspension bolt pitch
Suspension bolt pitch
21-1/32 (534)
21-1/32
(534)
12-7/16
23-5/8 (600)
Ceiling opening dimensions
23-5/8 (600)
Ceiling opening dimensions
7
Center of
panel
24-19/32 (625)
24-19/32 (625)
13-5/32 (334)
14-3/32 (358)
1
2
2
2
2
7-11/16
4-29/32
A View
8
1-3/16
21/32
3-1/8
The length of the suspension
bolts should be selected so that
there is a gap of 1-3/16" or
the ceiling (21/32" or more
below the lower surface of the
main unit), as shown in the
figure at right. If the suspension
bolts is too long, it will contact
the ceiling panel and the unit
cannot be installed.
AA
Air intake
Discharge outlet
Refrigerant tubing
(liquid tube)
dia.
1/4" (flared)
Refrigerant tubing
(gas tube)
dia. 1/2"
(flared)
Drain tube connection port VP20 (outer dia. 1")
Power supply port
Suspension bolt hole (4 - 1/2" x 1-1/8" hole)
Fresh air intake duct connection port (dia. 3-7/8")
1
2
3
4
5
6
7
8
7-23/32
1-27/32 1-3/32
2-3/32
2-3/4 1-9/32
5-9/16
25/32
10-13/16
3-19/32
ID:23/32
4-ID:15/16
21-3/16
6-3/32
4-9/32 2-5/32
Narrow tube service valve
dia.1/4" (6.35)
Wide tube service valve
dia.3/8" (9.52)
3-19/32
15/32
10-7/16 (265)
11-13/32
12-7/16
Outdoor Unit CH1271
28-11/32 (720) 2-1/8
21-9/16 (548)
5/8
Features
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver
(Horizontal) Manual
(Vertical) Automatic
Power Failure Automatic Restart
Self-Diagnosis
Air Filter
Air Clean Apatite Filter
Quiet Operation
Ion Generator
Microprocessor
LCD Wireless Type, Temp. Sensor Built In
IC Thermostat
24 Hr Program; 1HR ON/OFF
Built-In
Built-In
Built-In
Washable, Anti-Mold
Standard
Built-In
Built-In
Options
Refrigerant Line Set
Fresh Air Intake
Airduct Extension
Condensate Drain Pump
Hard Wired Remote Controller
Non-Removeable Locking Remo-con Bracket
Available
Knock-out
N/A
Standard
Available
Available
Operating Range
Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 95F DB/71F WB 115F DB
Minimum 67F DB/57F WB 50F DB
Sanyo Commercial Solutions
A Division of SANYO North America
1300 Michael Drive
Wood Dale, IL 60191 USA
www.sanyohvac.com