Split System Submittal Data
System: 09KS71 Indoor/Outdoor: KS0971/C0971
Wall Mounted Air Conditioner
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data (at 115V)
Power V/PH/Hz 115/1/60
Circuit Ampacity
Fuse Size, Max.
Compressor
No. used
R.L. Amps - L.R.
Crankcase Heater
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps
(A) 20
(A) 20
DC Rotary Inverter
(A) 7.6 - 20
N/A
Propeller
15-3/4-1
DC Motor
(RPM) 8 - 750
(W) 50 - 1
(High) 883
(A) 0.6
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max
Lift Difference, Max
Line Size
Line Size
Dimensions
Indoor Unit
Outdoor Unit
R410A
2.09
Electric Expansion Valve
Flare
50
23
(in. O.D. Discharge) 1/4”
(in. O.D. Suction) 3/8”
(in.) H x W x D
(Uncrated) 11-7/32 x 32-15/32 x 7-7/16
(Crated) 13-25/32 x 35-7/16 x 10-1/32
(Uncrated) 21-9/16 x 28-11/32 x 10-7/16
(Crated) 23-5/8 x 33-11/16 x 14-1/4
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size
(sq.ft.) 3.1
(in.) 5/16”
(RPM, High) 4 - 1200
(W) 46 - 1
(HI/Med/Lo) 282/247/200
(Hi) (dB-A) 34
(A) 0.45
(sq.ft.) 2.02
(in.) 9/32”
Aluminum Fin & Copper Pipe
Corrugated Plate - Inner Riffeled
2 - 18.1
Cross Flow
3-11/16 24-31/32 - 1
3 & Auto
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riffeled
2 - 19.5
(in.) 23/32”
Weight
Net
Shipping
Shipping Volume
Performance Data @ ARI Standard Conditions (115V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating
(lbs.) 19.8 72.8
(lbs.) 24.3 79.4
(cu.ft.) 2.82 6.36
(Pints/H) 3.4
(A) 7.6 (2.5-7.6)
(dB-A) 46
Indoor Outdoor
Indoor Outdoor
(BTU/H) 9,000 (3,000-9,000)
(BTU/H) 7,650
(BTU/H) 1,350
(W) 755 (250-755)
16
Dimensions
Feature
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver
Power Failure Automatic Restart
Heating/Cooling Automatic Changeover
Self-Diagnosis
Quiet Operation
Air Filter
Ion Generator
Air Clean Apatite Filer
(Horizontal) Manual
(Vertical) Automatic
LCD Wireless Type, Temp. Sensor Built In
Microprocessor
IC Thermostat
24 Hr. Program, 1 Hr. Off
Built-In
Built-In
N/A
Built-In
Built-In
Washable, Anti-Mold
Equipped
Standard
Option
Refrigerant Line Set
Fresh Air Intake
Airduct Extension
Indoor Frame Extension
Condensate Drain Pump
Non-Removeable Remo-con Bracket
Operating Range
Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
-
Maximum 95F DB/71F WB 115F DB
Minimum 67F DB/57F WB 67F DB
Available
N/A
N/A
N/A
Available
Available
Sanyo Commercial Solutions
A Division of SANYO North America
1300 Michael Drive
Wood Dale, IL 60191 USA
www.sanyohvac.com