A = Compressed Fibre CI = Cast Iron
AL = Aluminum PS = Plated Steel
Alm = Almag 35 Aluminum SS = Stainless Steel
B = Nitrile
Materials
Nitrile General purpose, oil-resistant. Shows good solvent, oil, water and hydraulic uid resistance. Should
not be used with highly polar solvents like acetone and MEK, ozone, chlorinated hydrocarbons and nitro
hydrocarbons.
For specic applications, always consult “Chemical Resistance Chart" Technical Bulletin
Maximum and Minimum Temperatures are the limits for which
these materials can be operated. Temperatures coupled with
pressure affect the longevity of diaphragm pump components.
Maximum life should not be expected at the extreme limits of
the temperature ranges.
Operating Temperatures
Maximum Minimum
190°F -10°F
88°C -23°C
II 2 G c T5
II 3/2 G c T5
II 2 D c T100oC
All models, including pumps equipped with Aluminum wetted and midsection parts.
See page 16 for ATEX Explanation of Type Examination Certicate.
dmf3sdl7sm-rev0614 Model DFM3S Page 2
Dimensions:
Dimensions are ± 1/8"
Figures in parenthesis = millimeters
DMF3S
27.63
339
90.43
668
38.91
405
1” NPT AIR INLET
3” NPT DISCHARGE PORT
48.8
422
57.3
59
57.3
59
3” NPT SUCTION PORT
43.03
177
05.81
074
1” NPT EXHAUST PORT
dmf3sdl7sm-rev0614 Model DMF3S Page 3
SERVICE AND OPERATING MANUAL
II 2GD T5
A WARREN RUPP PUMP BRAND
DRILLER’S MUD SERIES
See pages 15 & 16
for ATEX ratings
PLEASE NOTE!
The photos shown in this manual are for general instruction only. Your specic model
may not be shown. Always refer to the parts list and exploded view drawing for your
specic model when installing, disassembling or servicing your pump.
PRINCIPLE OF PUMP OPERATION
This ap swing check valve pump is powered by compressed air and is a 1:1
pressure ratio design. It alternately pressurizes the inner side of one diaphragm
chamber, while simultaneously exhausting the other inner chamber. This causes the
diaphragms, which are connected by a common rod, to move endwise. Air pressure
is applied over the entire surface of the diaphragm, while liquid is discharged from
the opposite side. The diaphragm operates under a balanced condition during the
discharge stroke, which allows the unit to be operated at discharge heads over 200
feet (61 meters) of water head.
Since the diaphragms are connected by a common rod, secured by plates to the
center of the diaphragms, one diaphragm performs the discharge stroke, while the
other is pulled to perform the suction stroke in the opposite chamber.
For maximum diaphragm life, keep the pump as close to the liquid being pumped
as possible. Positive suction head in excess of 10 feet of liquid (3.048 meters) may
require a back pressure regulating device. This will maximize diaphragm life.
Alternate pressuring and exhausting of the diaphragm chamber is performed by
means of an externally mounted, pilot operated, four-way spool type air distribution
valve. When the spool shifts to one end of the valve body, inlet air pressure is applied
to one diaphragm chamber and the other diaphragm chamber exhausts. When the
spool shifts to the opposite end of the valve body, the porting of chambers is reversed.
The air distribution valve spool is moved by an internal pilot valve which alternately
pressurizes one side of the air distribution valve spool, while exhausting the other side.
The pilot valve is shifted at each end of the diaphragm stroke by the diaphragm plate
coming in contact with the end of the pilot valve spool. This pushes it into position for
shifting of the air distribution valve.
The chambers are manifolded together with a suction and discharge check valve
for each chamber, maintaining ow in one direction through the pump.
Model DMF3S
Type 7
INSTALLATION & START-UP
Locate the pump as close to the product being pumped as possible, keeping suction
line length and number of ttings to a minimum. Do not reduce line size.
For installations of rigid piping, short exible sections of hose should be installed
between pump and piping. This reduces vibration and strain to the piping system.
A Warren Rupp Tranquilizer
pulsation in ow.
This pump was tested at the factory prior to shipment and is ready for operation. It is
completely self-priming from a dry start for suction lifts of 20 feet (6.096 meters) or less.
For suction lifts exceeding 20 feet of liquid, ll the chambers with liquid prior to priming.
®
Surge Suppressor is recommended to further reduce
AIR SUPPLY
Air supply pressures cannot exceed 125 psi (8.61 bar). Connect the pump air inlet
to an air supply of sufcient capacity and pressure required for desired performance.
When the air line is solid piping, use a short length of exible hose (not less than 3/4"
(19mm) in diameter) between pump and piping to eliminate strain to pipes.
AIR INLET & PRIMING
For start-up, open an air valve approximately 1/2" to 3/4" turn. After the unit primes,
an air valve can be opened to increase ow as desired. If opening the valve increases
cycling rate, but does not increase ow rate, cavitation has occurred, and the valve
should be closed slightly.
For the most efcient use of compressed air and the longest diaphragm life, throttle
the air inlet to the lowest cycling rate that does not reduce ow.
dmf3sdl7sm-rev0614 Model DFM3S Page 4