61 Huuru Prgh
Error Display Cause/Appearance of Error Way of Release
Water
level
sensor
abnormal
Temperatu
re sensor
abnormal
Motor
driving
abnormal
IE
tE1
tE3
3E1
3E2
3E3
If higher than 32kHz or lower than 10kHz of water level
sensor frequency is continuously kept for 4sec in every
0.5sec measurement, this error will occur.
(caused by wire-breaking of water level sensor)
If AD converter data in water temp sensor become larger
than 63,000 (in case of the temp. sensor being open) or less
than 2,000 (in case of the sensor being short-circuited), this
error will occur.
If AD converter data in fan-housing temp sensor become
larger than 63,000 (in case of the temp. sensor being open)
or less than 2,000 (in case of the sensor being shortcircuited), this error will occur.
If AD converter data in drying-duct temp sensor become
larger than 63,000 (in case of the temp. sensor being open)
or less than 2,000 (in case of the sensor being shortcircuited), this error will occur.
In case that position detection signal was not detected longer
than a unit set time during the motor starting and driving, it
will be retried 5 times. If it is not detected more than 6 times,
this error will occur. (caused by wire-breaking of haul-sensor
and motor, or by restriction of motor driving.)
If an excessive current is detected at IPM, it will be retried 6
times.Butifitisdetectedmorethan7times,thiserrorwill
occur.
(caused by short-circuit of motor wire)
If motor rotates in reverse direction during the motor starting
and driving or abnormal signal is detected at haul sensor, it
will be retried 8 times. But if it is detected more than 9 times,
this error will occur. (caused by motor overload or noise)
Power Off
Power OfftE2
Start button
Power
abnormal
3E4
PHI
Plo
If 8 times retrial of motor positioning is failed during the early
time of motor driving, it will be retried continuously. But if it is
failedmorethan32times,thiserrorwilloccur.(causedby
wrong connection of haul sensor or motor wire)
If more than 450V of instant voltage is detected at DC Link,
this error will occur.
(caused by an electric failure during the high-speed
dehydration)
Appearance: IPM Low Arm Short Break
In case that there is no AC power signal for longer than
60mSec, or that less than 125V of DC Link average
voltage is detected, or that less than 175V is detected
during the PHI error, this error will occur. (caused by
instant electric failure or wire break of power cord)
Appearance: Motor-generating current will be charged
through IPM All Open Break.
If both AC
power signal
and DC link
voltage are
normal, this
error will be
released and
proceed the
previous
operation.
- 17 -
Main relay
abnormal
Switch
(button)
abnormal
Door
abnormal
Communic
ation
abnormal
Excessive
water
level/water
leakage
Fan motor
abnormal
Water
Feed
abnormal
Water
Drain
abnormal
If AC power signal is detected for longer than 4sec even after
18E
connection of power plug or after opening of the relay by power
off, this error will occur.
If power switch is continuously being pressed for 12sec after
12E
power-on, this error will occur.
If a button on the control panel is continuously being pressed
14E
for 30sec.
If there is no press of any button for 10min after power-on or
8888
changing course before entering an operation, this error will
occur.
If door is open for longer than 1sec at the time of entering or
dE
during an operation, this error will occur.
If the lock or unlock function of door doesn't work after 3time of
dE1
trial, this error will occur.
This error occurs to protect a coil in the locking apparatus
dE2
against frequent usage of lock and unlock function of door.
If a communication to MCU on the control panel is abnormal for
longer than 2sec, it functions to reset MCU to 20mSec and to
13E
retry the communication. Abnormal communication for longer
than 6sec will make this error.
If less than 20.48kHz of frequency of water level sensor is
continuously kept longer than 10sec, this error will occur.
(caused by abnormal increase of water level due to breakdown
0F
of feed valve)
Appearance: It functions to operate drain pump to the frequency
level of 23.30kHz in 20sec-On/4sec-Off.
If higher than 24.70kHz of frequency of water level sensor
11E
during washing and rinse, this error will occur.
(caused by water leakage at pump, hose, drum tub, etc.)
If excessive current signal due to restriction of fan motor is
F
detected for longer than 40sec, this error will occur.
If the feed water for washing or rinse doesn't reach the terminal
4E
level of water supply after 20min, this error will occur.
If higher than 70°C is continuously detected for longer than
4Ed
8sec at temperature sensor of drying duct during drying, this
error will occur.
If higher than 50°C of water temperature is detected at the time
of water feed after selection of WOOL and LINGERIE
EC
COURSES, this error functions to prevent damage from such a
high water temperature.
If the water level frequency doesn't reach 24.70kHz after 15min
during the water drain, or if the water level frequency of less
5E
than 23.84kHz is detected for longer than 20sec during
dehydration or drying, this error will occur. (caused by foreign
matters in the drain pump or the breakdown)
Unplug the
power plug, and
PCB needs to
repair.
Power Off
No pressing of a
button longer
than 1sec will
release this error.
Power will be
automatically off
after 5sec.
Close the door
and press
START button
again.
Power Off
Automatically
released after
25sec.
If there is no
abnormal
communication
for longer than
1sec,itis
automatically
released.
Power Off
Power Off
Power Off
Start button
Start button
Power Off
Start button
- 18 -