SAMSUNG VC-6111, VC-6313H Service Manual Troubleshooting

5. Troubleshooting
Before attempting repairs: Confirm that the hose is inserted into the main body and that power plug is firmly inserted in the socket.
PROBLEM CHECK REMEDY
Motor does not rotate
Main body
• Power cord unplugged
• Disconnection of motor winding
• Commutator surface broken
• Abrasion or bad connection of carbon brush
• Abrasion or bad connection of cord-reel terminals
• Disconnection of wire
• Wire is separated from connector
• Reconnect power cord
• Motor replacement
• Motor replacement
• Motor replacement
• Cord-reel replacement or terminal reconnection
• Reconnect wire
• Connector connection
Hose Part
Suction control on handle does not operate.
Power cord does not wind
Power cord rewinds by itself
• When encountering abnormal use (like continuous operation while the dust bag is full) the protection device operates so as to protect the motor
• If the protection device is actuated, the cleaner does not operat
• Circuit
• Bad connection or contact of terminal plug
• Wire disconnected
• Circuit
• Power cord gathered to one side or twisted
• Preliminary winding of cord-reel is insufficlent
• Grease on the roller brake
• Roller brake abrasions
• Exchange the dust-bag & clean the auxiliary filter
• Remove any dust or alien substances that might clog the hose, extension tube or inlet port.
• After waiting about 20 minutes (with the power plug disconnected), the vacuum cleaner is ready for re-use
• Exchange or repair the hose
• Wire reconnection
• Hose exchange or circuit exchange
• Hose exchange or circuit exchange
• Wind again after pulling 1-2m
• Re-do the preliminary winding
• Remove any grease (use alcohol).
• Dust bag is filled Dust Indicator
• Make the inlet port airtight (at maximum power), check if the dust
indicator is red. If so, exchange the dust bag. Suction power is weak
SAMSUNG ELECTRONICS CO., LTD.
• If the suction power is not restored by replacing the dust bag, confirm that dust
or other alien substances are not clogging the hose, extension tube or inlet port.
• Dust indicator is separated from the
main body
• The seal is broken
• Exchange dust bag
• Reassemble the dust indicator securely
• Reassemble each sealing (rubber gasket)
5-1
PROBLEM CHECK REMEDY
Rotation of motor is weak
• Defective bearings
• Circuit trouble inside the Main Body
• Motor replacement
• Replace circuit
Sparks are unusually big
• Commutator surface is rough
• Carbon brush abrasions
• Motor replacement
• Motor replacement
5-2
SAMSUNG ELECTRONICS CO., LTD.
Loading...